HomeMy WebLinkAbout13020148.5PLUMBING SCHEDULE
Itu PLUM
NO QTY EQUIPMENT CATEGORY N0.
1 1 24X30 SHELVING UNIT
I
I
CW
IN
HW
IN
AFF 1N
z
W
1"t
o
z
o
Wes-
0 ¢
w
U
w
a
M o
GAS
N0.
GAS
SIZE
1'
MBTUH
AFF IN
ROOF
PLUMBING
REMARKS
SUPPLY FAN PROVIDES MAKE -UP AIR FOR BOTH EXHAUST HOODS
2 1 DUNNAGE RACK
�
W
LU
J
11
U
a
U)
Q
z
J
J
Q
3 1 3 COMP SINK W/PRE RINSE FAUCET
W
2:
3/eC*l/fHW
N
WAFF 11
1/2'
10'AFF
FS
Z
a
ADVANCED TABCO - FC- 3- 1515 -15K
4 1 COX30 S/S WORK TABLE
W
I..L
W
cj
5 1 CHEST FREEZER
N
CK
�o
W
?c
�
I
r
Q
6 1 REACH -IN FRIDGE
J
�[ I
mQ
r
en
M
N
LLL
7 1 PREP SINK
P11
1/2'CW[1/2HW,
WAFF
W
FS
ADVANCED TABCO - KMS- 11B -305L
8 1 3OX48 WORK TABLE
Z
/U
I..L�
9 2 MIXER
Vf
F-
u
W
H
_
10 1 WATER HEATER
1 /2 -CW
Q
WATER HEATER IS EXISTNIG TO REMAIN
11 3 TRASH RECEPTICAL
12 1 3OX60 CUTTING TABIE
13 1 2 WELL STEAM TABL`
14 1 EXHAUST SYSTEM W/ HEATED MAKE -UP AIR _
1 5 1 BLODGETT 1048 DOUBLE DECK PIZZA OWN
3/4'
170K BTU
18'AFF
BLODGETT MODEL NUMBER - 1048 (DOUBLE)
15 1 4 BURNER GAS RANGE
314'
112K BTU
18'AFF
SOUTHBEND S- SERENES RESTMANT RANGE - S24C
17 1 PIZZA PREP TABLE
-
18 1 3000 S/S WORKTABLE
19 1 REACH -IN FRIDGE
20 1 2060 WIRE SHELVING UNIT
21 1 SALAD /SANDWICHPRLP TABLE
22 1 ICE TEA MAKER
23 1 COKE MACHINE
1 /2 -CW
48'AFF
FD
24 1 GLASS DOOR MERCHENDISER
25 1 24X36 WIRE SHELVING UUNIT
26 1 HAND SINK
1/2- CW1
/2'
14 -AFF
1 1/2'
18 -AFF
27 1 2048 S/S WORK TABLE
2P 1 21 X 60 WIRE SHELVING UNIT
29 SPARE NUMBER
30 3 2OX25 TABLE WITH 2 C{iAIRS
31 2 36X36 TABLE WITH 4 3HAIRS
32 7 24X40 TABLE WITH 4 CHAIRS
33 1 CUSTOM CORNER TABLE FOR BOOTH
34 1 CUSTOM CORNER TABLE FOR BOOTH
_
35 1 SPARE NUMBER
36 1 CUSTOM CORNER BENCH SEAT
37 1 CUSTOM CORNER BD CH SEAT
38 1 PICK- UP/WAITING BOOTH
FIXTURE/EQUIPMENT P
SCALE - 1/4 11 = 1'
Legend
❑Junction boxes coordinate with tenant on wiring
requirements
Building standard 2x4 fluorescent light fixture existing to
remain
2x4 fluorescent light fixture with acrylic lens. (2) 32W78
lamps 73 Watts total
Denotes light fixture wired to 24 hour circuit ( "night light ")
o- Pendant hung light fixture to be selected
18W fluorescent can light with white trim ring 23 watts
total
OThermostat
Wall mounted light or other switch
3 = 3 way switch
4 = 4 way switch
D = electronic dimmer
Wall mounted emergency light w/ 90 min. backup. Equal
to navilite N1WH with (2) 5.4 watt lamps, 11 watts total
EXIT Wall mounted exit light w/ 90 min. backup equal to navilite
NXP3GWH. 2.7 watt total LED lamps
EXIT
Wall Mounted combo emergency light and exit light w/ 90
min. backup. Equal to navilite NXPC3GWH. 4.2 watts total
standby
Existing ceiling grid
® Gypsum board bulkhead
11-911 Diffuser - Supply
MR101
M }
W Y• W Diffuser - Return
maim
® Combination fluorescent light /fan ducted to exterior.
Equal to Boran QTXE- 1S0FLT with (2) 18 watt lamps, 48
watts total
Note: Supply and Return locations shown on plans for reference
only. Contractor is to provide new layout under design - build
contract
Mechianical contractor is to locate all roof mounted equipment
for structural stability and to provide any required bracing and
support needed for any roof top equipment.
Provide deduct alternate to re -lamp existing 2x4 fixtures and
re- install in rooms: Utility, Dry Storage, Kitchen, Prep and serving
areas
Final location and selection of all fixtures to be coordinated with
tenant and architect
N
N
OC
PROJECT NUMBER 2013.02
DATE= February 4th 2013
DRAWING NUMBER
MEP -1.1
OF DRAWINGS
N
N
CC
W
Z
Q
Z
Q
X
�
W
LU
J
11
U
a
U)
Q
z
J
J
Q
�
Q
W
2:
LI
N
�Q
U
Z
a
W
I..L
W
cj
X
N
CK
�o
W
?c
�
I
r
Q
W
W
J
�[ I
mQ
r
en
M
N
LLL
U
W
Z
/U
I..L�
Q
Vf
F-
u
W
H
u
Q
PROJECT NUMBER 2013.02
DATE= February 4th 2013
DRAWING NUMBER
MEP -1.1
OF DRAWINGS
N
Q
X
�
W
LU
M
cn
a
U)
Q
z
J
Q
�
Q
W
2:
N
�Q
a
PROJECT NUMBER 2013.02
DATE= February 4th 2013
DRAWING NUMBER
MEP -1.1
OF DRAWINGS