HomeMy WebLinkAbout05060038-05060039 Tree Preservation Plan Dated 7/26/2005------ - - - - -- SETBACK /EASEMENT LINE
SAN SANITARY LINE
__----------------- STORM SEWER LINE
--------- - - - - -- 10, 1 ....... _.. -- WATER LINE
LEGEND:
20 D.F. - DRAINAGE EASEMENT
`Y ; r
N WATER VALVE
WATER LINE TEE
PROPOSED FIRE HYDRANT
STORM MANHOLE
SANITARY MANHOLE
WATER BLOW OFF
1 STORM CATCH BASIN /INLET
FYSB FRONT YARD SETBACK
RYSB REAR YARD SETBACK
SYSB SIDEYARD SETBACK
ROW RIGHT -OF -WAY
TREE LEGEND:
4 t
"sl
�r
4" TREE
6" TREE
8" TREE
10" TREE
12" TREE
14" TREE
16" TREE
18" TREE
21 " TREE
24" TREE
27" TREE
30" TREE
42" TREE
TREE TO BE REMOVED
oq C) Co ba-L-1 PPAouuw �
osc�c� co3, p(aipu-1,
15' -0"
CONC. END SECTION
6" MINIMUM RIPRAP
FABRIC SECURING PINS
ENGINEERING FABRIC, 8oz /SYD. MIN. J
COMPACTED SUBGRADE
END SECTION
& RIPRAP DETAIL
NOT TO SCALE
TOE WALL
EXTERIOR CLEANOUT
W/ COUNTERSUNK HEAD
r-GRADE OR PAVEMENT
"X6"
E PAD
'E AND
0
0
SANITARY FLO
SANITARY
CLEANOUT &MANHOLE r2�_
NOT TO scuF 9
FOR DEBRIS /ANIMAL GUARD.
ANIMAL GUARD DETAIL
NOT TO scuE 9
A
tz
�tz
w
0
J
Q
0
J
3
PLAN
C B
GROOVE — OUTLET END)
TONGUE —INLET END)
OR T
SECTION A —A'
N
N
12"
J
J
A' DIAMETER
w
1 1/2" MD.
1/32 TAPER PER
Q
INCH PER SIDE
HORIZONTAL FLARE
ELEVATION
1
WALL
VERTICAL FLARE
SECTION B —B'
nlA1ir=13
SIZE SCHEDULE
DIA. I
WALL I
G or T
WE SEC
A
B
C
D
E
IA.+
R -1 I
R -2
SKIRT
12 1
2 1
2 -4
1 -8
2
530
740
4
6
24
27
48 -1
46
72 -1
73
24
30
13
16
10 -1
12 -8
9
11
3 -8
3 -8
15
18
2 -8
2 -w
3
2 -8
2 -4
2 -8
990
1280
1520
9
9
9 -8
1 27
1 35
43 -8
46
38
30
73
73
73 -8
36
42
48
19
1 22
25
15 -8
16 -2
16 -q
12
13
14
4
4
4 -8
21
24
NOTE: MANUFACTURER OF END SECTION IS IN ACCORDANCE WITH APPLICABLE
PORTIONS OF A.S.T.M. SPECIFICATION C76.
CONCRETE END SECTION / 4
Nor ro Scue 9
1 1/2" RAD.
ALL
R -37
INLET HOOD DETAIL 5
NOT TO SCALE 9
* A placard with the words " No dumping of waste, solvents or paint allowed"
needs to be added to all inlets.
Inlet casting or grate
and frame as specified
on structure chart.
3 33/4"
x x •
(2) #5 Rebors I�
■ 36" long
Precast concrete spacers;
or solid concrete block 21212 2'1212
& mortar per CO. specs.
M
U_1
iY
Q
>
NEENAH R -3700
N .
•. • .I w i
■
cc
42" Min.*
Notes:
1. Dimensions shown in conformance with Indiana
* Dimensions vary according to required Dept. of Transportation (INDOT) Specifications.
pipe sizes and casting specifications. 2. Poured benchwall and pipe connection vary with
* Structure 1103 will not have the hood box type specified.
due to the inaccessibility 3. Height dimensions may vary as required by
site conditions.
PRECAST C BOX INLET
TYPE E W/ROLL CURB 6
NOT TO SCALE 9
3
. '
'. '�.
Pipe connections
per Table 404 -1
of waste, solvents or paint allowed" needs
��.Y.A�- ,
.' ' •
of Specifications
M
42" Min.*
•
4" Sub - Surface
. .
0 1#
"
NOT TO SCALE
9
Drain Connection
•. •
"
(D
1'
'
See note 2
W
•
",
'
• " " *
• '.
S
2) BELL TO SPIGOT MAY BE ADJACENT
Max. P�ipps
>
' . •
Drain Connection
..
IF
• .
•
See note 2
'------
.••
Pipe
12" A0
•
V
- -- ----
(TYPICAL ALL LATERALS
NEENAH R -3700
N .
•. • .I w i
■
cc
42" Min.*
Notes:
1. Dimensions shown in conformance with Indiana
* Dimensions vary according to required Dept. of Transportation (INDOT) Specifications.
pipe sizes and casting specifications. 2. Poured benchwall and pipe connection vary with
* Structure 1103 will not have the hood box type specified.
due to the inaccessibility 3. Height dimensions may vary as required by
site conditions.
PRECAST C BOX INLET
TYPE E W/ROLL CURB 6
NOT TO SCALE 9
---------- ----- - --- - - - - -- Notes:
I 1. Dimensions shown in conformance with Indiana
• • •• • Dept. of Transportation (INDOT) Specifications.
• • • .: • 2. Poured benchwall and pipe connection vary with
j box type specified.
_V - - - - -. - ...._. -- � � 3. Height dimensions may vary as required by
site conditions.
* Dimensions vary according to required
pipe sizes and casting specifications.
r7
HOODED DITCH INLET DETAIL
NOT TO SCALE 9 7
ANHOLE CASTING SCI•
CAS nNG SHALL BE LITHER SELF SEALING OR WATEfiTIGFiT,
(SEE. PLAN & PROFILE SHEETS FOR CASTING TYPE). UDS
SHALL BE STAMPED *SANITARY SEWER" AND HAVE CLOSM
PICKHMES. FRAME SHALL BE SET ON IUBLE ROW OF 1/1
KENT SEAL, OR S1NCLE ROW OF 1" KENT" SEAL. -(SEE
IMANHOLE CAS'I1NG SC.H ED. ULE) .................................................................... ........
.......... ............. ...... .......... ...
INISH GRADE---.::..
NF'ISHIELD `UNIBAND "-•
WTYL RUBBER
N
ci
x
. --• PRECAST CONCIRM ADJUSTING RING
DC3UBLE ROW OF KENT SEAT.
-- tuIANHOLE STEPS PER SPECS
INTERIOR JOINTS AND UF"T HOLES
—SHALL BE SEALED WITH 14ON— SHRINK
GROUT .PER SPEC.'S. NO GROUT ABOVE
10P OF CONE SECTION
SET BARREL JOINTS TH RUBBER TYPE GASKET
EQUAL TO ASTM 0 --443 AND ON DOUBLE ROW OF
" KENT SEAT. OR SINGLE ROW OF 1" KENT SEAL.
■--• -• MANHOLE REINF. PER ASIM SPECS
e/—PIPE DIA. PER PLAN dG PROFILE
•••- 8£14CHWALL SHAM.. BE CLASS "B" CONC.
1-- SENCHWAIL HEIGHT SHALL 8E WZ OF PIPE DIA.
4'-0~ --" 6" MIN. COMPACTED #8 STONE
SANITARY MANHOLE -- TYPE "A"
NOT TO SCALE
TYP. PRECAST
CONCRETE MANHOLE DETAIL r8�
NOT TO SCALE 9
'3N l
l?KS Gf LA r�Ai VW'MACVR VO L tit' A St Or
FtR01! Y+�+t LSE SE1 R.
I ME 'M K SOIiAK, Ttlio R pop CMPU tiS SFi" BE MO, 00, AT
i rPfMF'EFfTY OR EACH 00 OF :kE OYF"t'41M W YK M*M tW- TW tk1N+Tf4 OF •A•
I .... l VA.SDANT U 43'f�tBE S�i(eA�t�l}� OR
MAIN t/2�tpN�S��i OF THAT OF V. riYE'3 iFAf K 11 LL
• DS..f.GY' 1/>l gDI L STRAKHT GP. .
..A"-
a•s LATc'T/�L
fMAIN I �
I COQ CONNECTM q
'
SECt121 A•-R
EASEMENT L9ME
MAN SS" L8c 1a.
A ., 13 �•� LAIE�tAL
I
i"�.. g �F4Ari 1fI r :»
CoLtpu4aj
l A a �•
E P sly.-
' _ �a
E; 1, G rW 3,A7'FAALS %W.L K 764E SAME AS FM LK SEVER.
E t. !"47RI & WAM FOR LAM MS %BALL W_ 9/0 T �?
i � M
3 ice: COOCC FOR LAn- AALS'.JFO" ai t/r OER FOOT. � n
4. XL mr cs VYAL Be XA M
I VHM 8ASEIM04M WTAn A BATA WM
4. MARK M OF;„AIVAL AT FM'Vttf LK WIH A WAL r POT,
j #0T to
EXISTING PIPE CONNECTION / s
NOT i0 SCALE 9
NOTE:
TO BE USED WHEN CLEAR DISTANCE (FROM EXTERIOR PIPE
DIAMETER TO EXTERIOR PIPE DIAMETER) BETWEEN SANITARY
SEWER PIPING (MAINS, LATERALS, FORCE MAINS, ETC.) AND
ALL OTHER PIPES IS 18" OR LESS, PER ENGINEER'S DIRECTION,
OR WHERE NOTED ON THE CONSTRUCTION PLANS. A MINIMUM
CLEAR DISTANCE OF 3" MUST BE PROVIDED TO MAINTAIN
STRUCTURAL INTEGRITY OF THE CONCRETE.
CONCRETE MUST NOT COME INTO CONTACT WITH FORCE MAIN.
AT LEAST 3" OF SAND MUST BE PLACED AS A CUSHION AROUND
THE FORCE MAIN.
IF THE CONFLICT IS BETWEEN A WATER MAIN AND ANY SANITARY
SEWER PIPING, 18" CLEARANCE MUST BE MAINTAINED OR NOTE
ABOVE APPLIES AND ONLY GRANULAR FILL MAYBE USED.
aN c•
•'GIST, C
NO.
910326
STATE OF
3500 PSI CONCRETE
BOTTOM OF TRENCH
EXTENSION SECURED
TO STEEL POST ---<
GRADE_
Perspective Yew -earth cut away
CRADLE SHALL BEAR ON
UNDISTURBED EARTH
CONCRETE CRADLE DETAIL / 10
NOT TO scup —9 /
WELL COMPACTED
SUBSOIL
MIN. 4" SSD
6' STEEL FENCE "T" POST
CAP & TAPE
00 18" 24„
2"
E-
=1il =ifs;
r•�
I
'.. A E{
{T__ 1:
>r11E
{:::: : :: (� .
FIN. PVMT. ELEV.
G.l
•`jam
NEENAH R -4342 * A placard with the words " No dumping
'
3
of waste, solvents or paint allowed" needs
��.Y.A�- ,
to be added to all inlets.
42" Min.*
• •
Czr
^
0 1#
"
NOT TO SCALE
9
#4 BARS
6„
"
(D
1'
A. OPPOSITE SIDE LATERALS
W
•
N
LL
• " " *
• '.
S
2) BELL TO SPIGOT MAY BE ADJACENT
4" Sub - Surface
>
' . •
Drain Connection
..
GREATER THAN 12'
• .
•
See note 2
"
`
.••
O
12" A0
•
-------- --- - - --
OUTFLOW
(TYPICAL ALL LATERALS
{
NEENAH R -3700
SHALLOWER THAN 12'
1' (TYPICAL ALL
RIGHT -OF -WAY
N
DEEP)
---------- ----- - --- - - - - -- Notes:
I 1. Dimensions shown in conformance with Indiana
• • •• • Dept. of Transportation (INDOT) Specifications.
• • • .: • 2. Poured benchwall and pipe connection vary with
j box type specified.
_V - - - - -. - ...._. -- � � 3. Height dimensions may vary as required by
site conditions.
* Dimensions vary according to required
pipe sizes and casting specifications.
r7
HOODED DITCH INLET DETAIL
NOT TO SCALE 9 7
ANHOLE CASTING SCI•
CAS nNG SHALL BE LITHER SELF SEALING OR WATEfiTIGFiT,
(SEE. PLAN & PROFILE SHEETS FOR CASTING TYPE). UDS
SHALL BE STAMPED *SANITARY SEWER" AND HAVE CLOSM
PICKHMES. FRAME SHALL BE SET ON IUBLE ROW OF 1/1
KENT SEAL, OR S1NCLE ROW OF 1" KENT" SEAL. -(SEE
IMANHOLE CAS'I1NG SC.H ED. ULE) .................................................................... ........
.......... ............. ...... .......... ...
INISH GRADE---.::..
NF'ISHIELD `UNIBAND "-•
WTYL RUBBER
N
ci
x
. --• PRECAST CONCIRM ADJUSTING RING
DC3UBLE ROW OF KENT SEAT.
-- tuIANHOLE STEPS PER SPECS
INTERIOR JOINTS AND UF"T HOLES
—SHALL BE SEALED WITH 14ON— SHRINK
GROUT .PER SPEC.'S. NO GROUT ABOVE
10P OF CONE SECTION
SET BARREL JOINTS TH RUBBER TYPE GASKET
EQUAL TO ASTM 0 --443 AND ON DOUBLE ROW OF
" KENT SEAT. OR SINGLE ROW OF 1" KENT SEAL.
■--• -• MANHOLE REINF. PER ASIM SPECS
e/—PIPE DIA. PER PLAN dG PROFILE
•••- 8£14CHWALL SHAM.. BE CLASS "B" CONC.
1-- SENCHWAIL HEIGHT SHALL 8E WZ OF PIPE DIA.
4'-0~ --" 6" MIN. COMPACTED #8 STONE
SANITARY MANHOLE -- TYPE "A"
NOT TO SCALE
TYP. PRECAST
CONCRETE MANHOLE DETAIL r8�
NOT TO SCALE 9
'3N l
l?KS Gf LA r�Ai VW'MACVR VO L tit' A St Or
FtR01! Y+�+t LSE SE1 R.
I ME 'M K SOIiAK, Ttlio R pop CMPU tiS SFi" BE MO, 00, AT
i rPfMF'EFfTY OR EACH 00 OF :kE OYF"t'41M W YK M*M tW- TW tk1N+Tf4 OF •A•
I .... l VA.SDANT U 43'f�tBE S�i(eA�t�l}� OR
MAIN t/2�tpN�S��i OF THAT OF V. riYE'3 iFAf K 11 LL
• DS..f.GY' 1/>l gDI L STRAKHT GP. .
..A"-
a•s LATc'T/�L
fMAIN I �
I COQ CONNECTM q
'
SECt121 A•-R
EASEMENT L9ME
MAN SS" L8c 1a.
A ., 13 �•� LAIE�tAL
I
i"�.. g �F4Ari 1fI r :»
CoLtpu4aj
l A a �•
E P sly.-
' _ �a
E; 1, G rW 3,A7'FAALS %W.L K 764E SAME AS FM LK SEVER.
E t. !"47RI & WAM FOR LAM MS %BALL W_ 9/0 T �?
i � M
3 ice: COOCC FOR LAn- AALS'.JFO" ai t/r OER FOOT. � n
4. XL mr cs VYAL Be XA M
I VHM 8ASEIM04M WTAn A BATA WM
4. MARK M OF;„AIVAL AT FM'Vttf LK WIH A WAL r POT,
j #0T to
EXISTING PIPE CONNECTION / s
NOT i0 SCALE 9
NOTE:
TO BE USED WHEN CLEAR DISTANCE (FROM EXTERIOR PIPE
DIAMETER TO EXTERIOR PIPE DIAMETER) BETWEEN SANITARY
SEWER PIPING (MAINS, LATERALS, FORCE MAINS, ETC.) AND
ALL OTHER PIPES IS 18" OR LESS, PER ENGINEER'S DIRECTION,
OR WHERE NOTED ON THE CONSTRUCTION PLANS. A MINIMUM
CLEAR DISTANCE OF 3" MUST BE PROVIDED TO MAINTAIN
STRUCTURAL INTEGRITY OF THE CONCRETE.
CONCRETE MUST NOT COME INTO CONTACT WITH FORCE MAIN.
AT LEAST 3" OF SAND MUST BE PLACED AS A CUSHION AROUND
THE FORCE MAIN.
IF THE CONFLICT IS BETWEEN A WATER MAIN AND ANY SANITARY
SEWER PIPING, 18" CLEARANCE MUST BE MAINTAINED OR NOTE
ABOVE APPLIES AND ONLY GRANULAR FILL MAYBE USED.
aN c•
•'GIST, C
NO.
910326
STATE OF
3500 PSI CONCRETE
BOTTOM OF TRENCH
EXTENSION SECURED
TO STEEL POST ---<
GRADE_
Perspective Yew -earth cut away
CRADLE SHALL BEAR ON
UNDISTURBED EARTH
CONCRETE CRADLE DETAIL / 10
NOT TO scup —9 /
WELL COMPACTED
SUBSOIL
MIN. 4" SSD
6' STEEL FENCE "T" POST
CAP & TAPE
00 18" 24„
2"
E-
=1il =ifs;
r•�
I
'.. A E{
{T__ 1:
>r11E
{:::: : :: (� .
FIN. PVMT. ELEV.
G.l
•`jam
'X PVMT. AGGREGATE
.... ��s._.l" .yF''`---`:y �-
-�-/s - FILTER FABRIC (TYPAR 4.0
OZ /SY OR AN APPROVED
W /FILTER FABRIC SLEEVE
3
��.Y.A�- ,
� .. rA EQUAL, LAP 6" & STAPLE
i ff min.
1 mi .
Czr
12" COURSE AGGREGATE
ROLL CURB W/UNDERDRAIN
NOT TO SCALE
9
€
MIN 6" DIA CORRUGATED PVC
MIN. SLOPE 0.30
+ ..
W /FILTER FABRIC SLEEVE
3
i ff min.
1 mi .
18 "max.
ROLL CURB W/UNDERDRAIN
NOT TO SCALE
9
NOTE:
SEPARATION BETWEEN WYE FITTING:
A. OPPOSITE SIDE LATERALS
1) 1' MINIMUM BELL TO BELL
2) BELL TO SPIGOT MAY BE ADJACENT
8' MINIMUM
(TYPICAL ALL LATERALS
B. SAME SIDE LATERALS
1) 5' MINIMUM SEPARATION
GREATER THAN 12'
DEEP)
6' MINIMUM
(TYPICAL ALL LATERALS
SHALLOWER THAN 12'
1' (TYPICAL ALL
RIGHT -OF -WAY
DEEP)
LATERALS)
OR EASEMENT LINE
FOR SEPARATION SEE NOTE
ONE PIECE TEE -WYE
REQUIRED
RIGHT -OF -WAY
NOTE:
` "
'
OR EASEMENT LINE
ALL WYES AND LATERAL PIPE FROM 12' -20' FEET DEEP
SHALL BE SDR 26 (MINIMUM PIPE STIFFNESS OF 115).
ALL LATERALS OVER 20' DEEP SHALL BE SDR 23.5
6" SDR 35 OR
(MINIMUM PIPE STIFFNES OF 153) AND WYES SHALL BE
SCH 40 PVC PIPE
SDR 26.
(ALL LATERALS SHALLOWER
MAIN SEWER LINE
THAN 12')
�c BEDDING TO BE PLACED ON UNDISTURBED
EARTH. COMPACTION OF 0 STONE
IS CRITICAL UNDER ALL JOINTS AND FITTINGS.
IF PROPER COMPACTION CANNOT BE ACHIEVED,
THEN PLACE A MINIMUM OF 6" OF 3500 PSI,
28 DAY COMPRESSIVE STRENGTH CONCRETE
PLAN
VIEW AROUND THE PIPE TO BEAR ON STABLE
GROUND (PER ENGINEER). PAINTED GREEN 2" X 4"
DEPTH TO LATERAL TO BE
SHOWN ON MARKER.
NOTE: SOLID PVC OR HDPE CAP OR S.S. BANDED RUBBER BOOT.
(TYPICAL ALL LATERALS)
PLACE A MINIMUM 8" DIAMETER HDPE
A MINIMUM OF 8" OF #8 STONE OVER
RIGHT -OF -WAY
PIPE AROUND LATERAL PRIOR TO
THE CONCRETE CAPPED WYE SHALL BE
OR EASEMENT LINE
BACKFIWNG. HDPE PIPE TO EXTEND
PLACED PRIOR TO BACKFlLLING. 4'
INTO CONCRETE.
FINISHED GRADE
22.5' OR 45'
rli, Ali,,
li, ,�I►
2' MINIMUM 4' MINIMUM
bey
22.5' OR 45'
F
5 MINIMUM - 8 MAXIMUM
(TYPICAL ALL LATERALS)
1 4' MINIMUM
75' OR LESS FOR SHORT SIDE c CAP FOR
LATERALS 45' OR LESS FOR LONG SIDE -; r FUTURE CONNECTION
LATERALS THIS ANGLE MUST BE 45' OR (TYPICAL ALL LATERALS)
LESS FOR ALL LATERALS
, = f T SHALLOWER THAN 12 FEET.
TO EXCEED BEYOND FIRST PIPE JOINT OF 6" MINIMUM MINIMUM FALL- 1/8" PER FOOT MAY NEED TO BE DEEPER FOR
WYE. IF A WYE IS 11' TO 12' DEEP, THEN (TYPICAL ALL LATERALS) LONG BUILDING LATERALS OR
CONCRETE CAP IS REQUIRED AT THE T FINISHED GRADES SLOPING AWAY
ENGINEER'S DISCRETION. MINIMUM FROM SEWER.
CONCRETE STRENGTH OF 3500 PSI, 28
DAY COMPRESSIVE STRENGTH.
NOT REQUIRED FOR DUCTILE IRON TEE. SECTION
FOR LATERALS GREATER THAN 12' NOTE:
DEEP, INSTALL ONE PIECE TEE -WYE. ALL LATERAL BEDDING SHALL BE
ALL FITTINGS SHALL BE OF ONE PIECE AGAINST UNDISTURBED TRENCH.
CONSTRUCTION.
MORE THAN 12' DEEP LESS THAN 12' DEEP
NOTE: DEPTH OF SERVICE LATERAL SHALL BE MEASURED FROM
FINISHED GRADE TO THE TOP OF MAIN SEWER LINE.
ALL PIPING FROM WYE TO 45'/22' FITTING AT 54 BELOW
GRADE SHALL BE SDR 26 TO 20' DEEP OR SDR 23.5 GREATER
THAN 20' DEEP.
MINIMUM 4" CONCRETE CAP REQUIRED, NOT
SERVICE LATERAL DETAIL 12
NOT TO SCALE 9
R.C.P. SIZED AS INDICATED ON
PLANS
#8 CRUSHED STONE OR APPROVED
EQUAL. CLASS I BEDDING MATERIAL,
HAND TAMPED OR WALK INTO PLACE
#8 CRUSHED STONE OR EQUAL.
CLASS I MATERIAL, HAND TAMPED
OR "WALKED" IN OR CLASS II
MATERIAL TO 95% STANDARD
PROCTOR DENSITY
Z � W
gOO�
w I!
'� m m
MIN. 6" TOPSOIL TO ENSURE
GRASS GROWTH
REGULAR BACKFlLL
MIN. 1.25 Bc + 12"
• + 12
WIDTH 1.25 (O.D.) IN.
n
.1�
1
.j. j N
m
PIPE SIZE
8 " -15"
18" AND OVER
BEDDING BELOW
THE PIPE BARREL
/•- =I-
B BORROW WHEN TRENCH
CASTING =822.40'
OPENING ENCROACHES WITHIN 5' -0"
SUBSURFACE TILE
OF AN EXISTING OR PROPOSED
I
STREET OR SIDEWALK. APPROVED
=-'
BACKFlLL MATERIAL OUTSIDE OF
BEDDING BELOW
STREET OR SIDEWALK BACKFILL
o
LIMITS. APPROVED BACKFlLL
o
MATERIAL MAY BE USED UNDER
..................
PROPOSED SIDEWALKS PROVIDED
........ : :...........
SIDEWALKS ARE CONSTRUCTED 6
BARS O 12' BOTH DIRECTIONS, IF
MONTHS AFTER BACKFILLNG OF
POURED IN PLACE CONNECT TO
TRENCH.
-
NOTES:
z J
• ALL BEDDING AND INITIAL BACKFlLL
-3
SHALL BE INSTALLED IN 6 —12
— m m
BALANCED LIFTS
PIPE SIZE
8 " -15"
18" AND OVER
BEDDING BELOW
THE PIPE BARREL
O.D. / 4
MIN. = 4"
O.D. / 4
MAX. = 8"
• Bc INDICATES OUTSIDE DIAMETER.
• A MIN. 9" CLEARANCE SHALL BE
PROVIDED ON EACH SIDE OF
THE INSTALLED PIPE.
R.C.P. PIPE TRENCH DETAIL-
NOT TO SCALE 15
"B" BORROW (INDOT SPEC.) OR
EQUIVALENT GRANULAR MATERIAL
COMPACTED TO 95% STANDARD
PROCTOR DENSITY
MIN. 6" TOPSOIL TO ENSURE
GRASS GROWTH WHERE
APPLICABLE
MIN. 1.25 Bc +12"
i__1
Inlet for Rol I Type Curb * A placard with the words " No dumping
of waste, solvents or paint allowed" needs
to be added to all inlets.
Heavy Duty
Illustrating 8-3501- (float right). If f1mi left !is required, Order as R- 3501 -TL.
r �
.8
I
Tj
_•
•
as
A NOW 29 •
-----------------------------••••------.........-------•----.........-•----...............---•-•••----.......••-•-•••-•-----.........----.....---••----------•--•..........-•-•••--•-----•---•-••--'•-------•._........-•---••--•----....----•--••--------.........----------------........--- •••...•••- •••.........-- - - -• -•
CURB INLET CASTING DETAIL %71
NOT TO SCALE jj
R-1642-A
Manhole Frame, Solid Lid
Heavy Duty
Lid is also available with 3/4" lift hole.
Frame is reversible for slab application.
[A.
�www� s�•r
SANITARY SEWER CASTING - R- 1642 -A
SANITARY1
STORM S WER CASTING s
NOT TO SCALE 15
* A placard with the words " No dumping
of waste, solvents or paint allowed" needs
to be added to all inlets.
R-25S4
Beehive Grate and Frame
S N
Designed to fit in bell of 24" sewer pipe. • �w �, � - ' �_ i *,�
Ftxnished standard with as -oast L�a�irsg suriacss,
..
........�,. r
Bc
DEPTH OF BEDDING NOTES:
MATERIAL BELOW PIPE LEGEND
D MIN.—SHALL ALL BEDDING k INITIAL BACKFlLL Bc = OUTSIDE DIAMETER
BE INSTALLED IN 6' TO p = INSIDE DIAMETER
27" do SMALLER 3" 12" BALANCED LIFTS.
d =DEPTH OF BEDDING
2. A MIN. 9' CLEARANCE SHALL BE MATERIAL BELOW PIPE
PROVIDED ON EACH SIDE OF
THE INSTALLED PIPE.
PIPE BEDDING r2
NOT TO SCALE 15
Us" 8,1761 frame.
CATCH BASIN CASTING DETAIL
FOR STORM SEWERS is
NOT TO SCALE 7
o z
A
:• ::
AND GRATE, OR APPROVED EQUAL. FOR STRj104.
18" AND OVER
..:• . � • :•: :
p; ° -_�- - N
CASTING =822.40'
FULL DEPTH PAVEMENT OVER STRUCTURE-
SUBSURFACE TILE
110 LBS/SYD HAC. SURFACE III
SHAPED BOTTOM OR 4"
330 LBS/SYD H.A.C. BINDER #8
I
2-4' LIFTS COUP. AGGR SIZE j53
BEDDING BELOW
:_:.':..'..' ....'.'.
... : :
.'....'.'..'� : ' ..'.'.'.'.'.'.
:'.'.' ..:.:.:.::.::....'. .
............:.
.:..'.:.: ..:....:.
..................
.. : :: : : :::......................
........ : :...........
. .......... :....................
N
L S I 4
PLAN
Earth or Sidewalk Surface
ELEVATION N
SIDEWALK RAMP
FOR HANDICAPPED 5�
NOT TO scuc 15 7-
24" Concrete Curb
40' RIGHT —OF —WAY
28' -0" ••' • • ." • • • '
• • • .x
24 pf 121_0, ROADWAY 12' -0" 24 x ' ' ' • x : •• x
.•x • • .
000
O o000
0
i' 4,_0» 1' 1' 6„ 0000
ROLL CURB (SEE DETAIL) 1 4' -0"
SIDEWALK Dodo'
SIDEWALK SIDEW 0, Installation Required:
-PROFILE GRADE C - Both Sides Of All
2 4% 2% 2% 4% --��-- #8 Washed Gravel or o� ° Pavement.
- Approved Equivalent 04
a
(INDOT Std. Specs.)
#53 COMPACTED NDERDRAIN °o`�OO°bo`b
AGGREGATE (TYP•) (SEE DETAIL) 1" H.A.C. BITUMINOUS SURFACE #11 0 o
3" H.A.C. BITUMINOUS BINDER #8 OR #9 Shaped Bottom
9" COMPACTED LIMESTONE BASE 4" 4"
Min. Min.
TYP. STREET CROSS SECTION 3 12"
NOT TO SCALE 15
PIPE UNDERDRAIN DETAIL 4
NOT TO SCALE 15 7-
F.
910326
�• STATE OF .jx.
=, F••• ••ND I 0
G,
.S,SIONAL i*% %% `
60�- -
NEENAH TYPE R- 6052 -F HEAVY DUTY FRAME -- ------
----1
AND GRATE, OR APPROVED EQUAL. FOR STRj104.
18" AND OVER
CAST INTO REDUCER CAP. TOP OF
p; ° -_�- - N
CASTING =822.40'
FULL DEPTH PAVEMENT OVER STRUCTURE-
SUBSURFACE TILE
110 LBS/SYD HAC. SURFACE III
SHAPED BOTTOM OR 4"
330 LBS/SYD H.A.C. BINDER #8
PAVEMENT ELEVATION -\
2-4' LIFTS COUP. AGGR SIZE j53
BEDDING BELOW
O.D. / 4
PRECAST REDUCER CAPASPHALT .........
�.
NOT TO
MASTIC OR BUM RUBEIER
SEAL EIEnVEEN JOINTS.
r W
SEE
FACE OF ORIFICE WALL., HAVING 14
MIN. = 6"
BARS O 12' BOTH DIRECTIONS, IF
o
POURED IN PLACE CONNECT TO
or no WM W
wa wAII. W/ KIM a" BOLT Ir
� -
RODS. (SHOP DRAIIANG MUIRED)
PREFORMED HOLE TO MAX•
�.
• `.
F'PE O.D. +B (11rP) w/ ..
� �
NON - SHRINK CEMENT GROUT.
J ♦�*,0' i
PRECAST SECTION WITH THE BASE —, ��,�
HAVING 14 BARS O 12. BOTH
DIRECTIONS OR APPROVED EQUAL
\
STEEL SET 3• MINIMUM FROM
OUTSIDE FACE.
��,.
STRUCTURE &4a TO BE SET � '• •
o
r a ; ti
UPON 6. OF COMPACTED 18
OR 12 STOIC = �- f =_. STR# 104
1. PRECAST BASIN OF APPROXIMATE DWOSIONS....ONE DEICE PRECAST CONCRETE
MAY BE USED UPON ENGINEER'S APPROVAL BASE AND CATCH EL&
Z. FOR LARGE DIAMETER PPE A PRECAST BOX
W/ A FLAT TOP AND CASW MUST BE USED.
ORIFICE DETAIL DETAIL FOR MH# 104 r15
DETAIL FOR MH# 104 rl 4 15
15
24 "x1/2 DIA. SMOOTH BAT AT 18" O.C.
GREASE AND DOWEL CAP w/ BAR STOP
AT BOTH ENDS
"B" BORROW WHEN TRENCH OPENING ENCROACHES WITHIN 1/2- SEALANT
5' -0" OF AN EXISTING OR PROPOSED STREET OR SIDEWALK.
NOTES: APPROVED BACKFlLL MATERIAL OUTSIDE OF STREET OR -
SIDEWALK BACKFlLL LIMITS. APPROVED BACKFlLL MATERIAL Aw'
• ALL BEDDING AND INITIAL BACKFlLL MAY BE USED UNDER PROPOSED SIDEWALKS PROVIDED o ' •� - �- L • 3 � �. L
SHALL BE INSTALLED IN 6 —12 SIDEWALKS ARE CONSTRUCTED 6 MONTHS AFTER BACKFILLING
r -
BALANCED LIFTS ° .. ° .: - - s � s • � � � -
/[O"VF ,l TRENCH. / .......... --------•--------=-------=----..... _ .......... _ ............... •..... - ...... =- n - - - -:: ......_---------------- .-------- = - - - --
-I \� \���� 1 2 EXP. JNT. FILLER
I. -_—
= 1I- 1IlMIN. WIDTH 1.25 (O.D. + 12 =
EXPANSION JOINT
#8 CRUSHED STONE OR #8 ^ I Z'.
FRACTURED FACE AGGREGATE, HAND = = z
- ��� �- � � ��a �� � = � - � \ 1/8- SAWED OR TOOLED
TAMPED OR WALKED INTO PLACE ' -�- { ;_ :• �<�;�'. {��_ .l N CONTROL JOINT
#8 CRUSHED STONE OR #8
__, ......... «.__- ....... _ ..... __ ......... ___RS_---- __- _.•_._• . .........
-
FRACTURED FACE AGGREGATE - . ° .'d
BELL HOLE EXCAVATED o 4. s
fl�� i J. �Jl I\ 1. { ji.^ `•� l _ / $ .
z I J CONTROL JOINT
J w
i� m m m m 24"x1/2" DIA. DEFORMED
`TIE BAR ® 18" O.C. I
PVC & HDPE PIPE LONGITUDINAL JOINT
FLEXIBLE PIPE NOTE:
TRENCH DETAIL CONSTRUCT EXPANSION JOINTS AT 40' MAX. AND CONTROL
JOINTS AT 6' MAX. UNLESS OTHERWISE NOTED.
NOT TO SCALE 15
CONCRETE JOINT DETAILS r13
GRADE
(NEW OR EXISTING)
/ '— I� —�:_; • Sao
I ! `
TOPSOIL BACKFlLL - I- - - - - --
R REPLACE TOP 6" w/ TOPSOIL
#8 WASHED GRAVEL-
PIPE SIZE
8 " -15"
18" AND OVER
CN
p; ° -_�- - N
6" PERFORATED
; a_
SUBSURFACE TILE
LBS /SYD
SHAPED BOTTOM OR 4"
M4'
'^'� Q • - •Q,
d
4" MIN.
BEDDING BELOW
O.D. / 4
O.D. / 4
NOT TO
SCALE
L
THE PIPE BARREL
MIN. = 6"
MAX. = 8"
o
�.
PVC & HDPE PIPE LONGITUDINAL JOINT
FLEXIBLE PIPE NOTE:
TRENCH DETAIL CONSTRUCT EXPANSION JOINTS AT 40' MAX. AND CONTROL
JOINTS AT 6' MAX. UNLESS OTHERWISE NOTED.
NOT TO SCALE 15
CONCRETE JOINT DETAILS r13
GRADE
(NEW OR EXISTING)
/ '— I� —�:_; • Sao
I ! `
TOPSOIL BACKFlLL - I- - - - - --
R REPLACE TOP 6" w/ TOPSOIL
#8 WASHED GRAVEL-
�`''�' =''
INDOT SPECS OR
( )
'
APPROVED EQUAL.
p; ° -_�- - N
6" PERFORATED
; a_
SUBSURFACE TILE
LBS /SYD
SHAPED BOTTOM OR 4"
BASE #5D
OF #8 WASHED GRAVEL
4" MIN.
BENEATH TILE
SWALE UNDERDRAIN DETAIL.
NOT TO
SCALE
VARIES (SEE PLAN SHEETS)
r
N
\ 6x6 — W2.f •Min n lit W r
- -4 6 a v
M..
4" 4" COMPACTED GRANULAR MATERIAL
COMPACTED SUBGRADE
NOTES:
1. CONTROL JOINTS, EXPANSION JOINTS AND EDGES OF SIDEWALKS
SHOULD BE HAND- TOOLED AFTER EACH FINISHING OPERATION.
2. PROVIDE A EXPANSION JOINT AT INTERSECTION WITH ANOTHER
SIDEWALK, BETWEEN WALKS AND BUILDINGS AND AT SUCH OTHER POINTS
AS INDICATED ON THE DRAWINGS.
3. SIDEWALKS SHALL HAVE 1/2" EXP. JOINTS AT 40' -0" MAX. AND CONTROL
JOINTS AT 6' -0" MAX.
CONCRETE SIDEWALK 8
1 1/2 it = 1' -0" 15
10
15
FINISH GRADE
110
LBS /SYD
BITUM.
SURFACE #11
330
LBS /SYD
BITUM.
BINDER #8
440
LBS /SYD
BITUM.
BASE #5D
COMPACTED AGGREGATE #53 2 LIFTS)
Ic
-_I I ;-- ---= =i I 1 - -1 I--- '__I•; -1 I �1 -1 I I- -1 ! - �.__I �-
- - - -- - - -= -
11• -1 - I I -1 I I- I_ 1EI I I -I I- 1 1' -:11 -
III — -- : —E...
COMPACTED SUBGRADE W/ LIME STABILIZATION
RIGHT—OF—WAY ASPHALT 11
1 1/2 " = 1' -0" 15
110
LBS / SYD.
BITUMINOUS
SURFACE X11
330
LBS / SYD.
BITUMINOUS
BINDER #9
COMPACTED AGGREGATE #53 (2 LIFTS)
I I =�I I - != III•; -! . - . I =I ! = .. - ..... -; I - -- III - =1 = ! I --
Iii I I II I � �_�.I � ` I .. - i =►11� 1 l -_E � -: ;
COMPACTED SUBGRADE W/ LIME STABILIZATION
ASPHALT SECTION 9
NOT TO SCALE 15
EROSION CONTROL
1. SUMMARY
A. Section includes provisions for temporary erosion controls
required throughout the Work to control erosion and water
pollution by using temporary construction entrances,
controlled discharge outlets, berms, sediment basins,
sediment dams, slit fences, brush barriers, baled hay and
straw, mulching, and temporary seeding.
B. Provisions are also included for riprap and geotextile fabrics
for permanent slope protection as part of the Work.
2. SUBMITTALS
A. At least 96 hours prior to breaking ground submit to the
Engineer all information required by the NPDES General
Permit for Storm Water pertaining to this project.
B. Submit for review and approval to the Engineer within 30
working days of receipt of the Notice to Proceed:
1. A list of materials necessary for and the
sequencing of activities to accomplish the work
encompassed by this Section along with
manufacturer's product data and specifications
demonstrating compliance with these
Specifications.
2. Installation instructions from applicable
manufacturers for products proposed to be
included in the installation.
C. Maintain on -site and keep current all required elements of
the NPDES General Permit for Storm Water pertaining to
this project.
3. QUALITY ASSURANCE
A. Detail qualified workmen that are experienced in executing
the activities specified in this Section.
B. Detail and maintain equipment capable of accomplishing
the activities specified in this Section while producing
sufficient progress on the Work.
C. Operate all equipment with due caution.
D. Instruct workmen in procedures specified in this Section.
4. SEQUENCING AND SCHEDULING
A. Install temporary construction entrances as part of the job
mobilization activities.
B. Install temporary perimeter dikes where shown on erosion
control plans and where needed to prevent erosion.
C. Install silt fencing prior to clearing and grubbing to prevent
sediment runoff.
D. Construct sediment traps as soon as practical to control
sediments.
E. Install straw bales and temporary sediment traps as work
progresses.
F. Utilize detention ponds into operations as storm drainage
detention facilities when the Work is nearing completion.
5. MAINTENANCE
A. Routinely inspect the site and clean out sediment traps at
least every seven days of within 24 hours after a rainfall of
0.5 inch or more.
B. Maintain sediment traps, silt fencing and dikes in good
working order.
C. Correct washouts and eroded areas by refurbishing and
temporarily seeding.
6. MATERIALS
A. Use only new materials conforming to the requirements of
these specifications and approved by the Engineer. All
materials proposed to be used may be tested and inspected
at any time during their preparation and use. If, after trial,
it is found that the source of supply has not been
approved, or does not furnish a uniform product, or if the
product becomes unacceptable at any time, the Contractor
shall furnish materials from another source. Approved
materials that become unfit for use shall net be used in the
Work and shall be removed from the job site.
. Materials indicated on the Drawings that are required in the
Work but are not covered in detail in the Specifications
shall be of the best quality available and shall conform to
the current specification of the American Society for
Testing and Materials (ASTM) or AASHTO, as approved by
the Engineer.
B. For sedimentation and erosion control use:
1. Baled straw and hay that complies with the
requirements contained in Section 02900.
2. Silt fences manufactured of fabric specifically
made for such purpose shall conform to the
requirements of AASHTO M 288 -90, and be
approved by the Engineer.
3. Temporary CMP drainage pipes chosen by the
Contractor that are adequate to perform under
subject field conditions.
4. Temporary seeding that complies with
requirements contained in Sections 02900.
5. Three inch maximum size coarse aggregate that
is free from deleterious materials and does not
contain more than 10 percent materials finer than
No. 4 sieve.
C. Slope protection shall be provided by:
1. Using stones that weigh no more than 150
pounds with at lease 20 percent weighing more
than 60 pounds while no more than 20 percent
weigh less than 20 pounds for hand placed
riprap.
2. Using geotextile fabric that is manufactured
engineering fabric conforming with AASHTO M
288 -90 for reducing soil erosion and that is
approved by the Engineer.
7. EXAMINATION
A. Examine all areas where slope protection and erosion
control are required.
B. Request underground utility location service to locate all
utilities within work areas.
8. INSTALLATION
A. Provide temporary construction entrances at all
Ingress/egress locations to reduce or eliminate transporting
soil or mud by vehicles to roadways and public rights of
way. Construct these entrances by installing a stone mat
using three inch maximum crushed stone. This mat shall be
a minimum of 50 feet long by 12 feet wide and at least 6
inches thick. Drain wash water to spray the underside of
vehicles and tires when parked in the stone mat. Provide
spent wash water drainage into a sediment basin or trap.
B. Install temporary perimeter, diversionary, and interceptor
dikes as shown on the Drawings and other places where
required in the field. Their purpose is to divert sediment
laden storm runoff to an on -site sedimentation trapping
facility or to direct storm water away from exposed slopes.
C. Provide temporary discharge controls that limit
concentrations of storm water flows by using level
spreaders, gravel outlets, and temporary drop piping shown
on the Drawings.
D. Provide sediment traps using silt fences, straw bales, or
sediment basins as shown on the Drawings. Utilize
detention pond facilities initially as sediment basins by
installing a temporary riser pipe as shown on the Drawings.
Install a marker to indicate the maximum level of sediment
accumulation to indicate when the facility requires cleaning.
Remove and replace the riser piping when nearing the
completion of the Work and when approved by the
Engineer. Remove accumulated residual sediment at that
time and treat the residue as waste. Place the facility into
a storm water detention mode of operation.
E. Hand place riprap a minimum of 12 inches thick on
designated slopes to comply with the Drawings. Begin
placement two feet below the tow of slope while firmly
imbedding each piece.
F. Install geotextile fabric for slope stability in accordance
with the manufacturers recommendations. Unless
otherwise directed, install the fabric with the long
dimension parallel to the toe of slope, and lay where a
smooth and wrinkle free surface is obtained that is not
under tension. Overlap subsequent fabric layers by at least
18 inches. Secure fabric using approved fasteners and
cover within 30 days using materials approved by the
Engineer.
B. PROTECTION
A. Repair damaged sediment control devices.
B. Insure exposed soil surfaces are not eroding.
C. Inspect and maintain the temporary construction entrances'
stone from accumulation of silt, mud, or other debris.
D. Prohibit vehicular traffic from crossing installed geotextile
fabrics.
EARTHWORK
1. SCOPE OF WORK
A. Extent: The work required under this section consists of all
excavating, filling, rough grading and related Items necessary to
complete the work indicated on the drawings and described in the
specifications. The Contractor shall notify in writing the owners and
the Engineer of any changes, errors, or omissions found on the plans
or in the field, before work is started or resumed.
1. In general, the items of work to be performed under this
section shall Include clearing and grubbing, removal of trees
and stumps (where required, protection of trees to remain,
stripping and storage of topsoil, fill compaction and rough
grading of entire site
2. Excavated material that is suitable may be used for fills. All
unsuitable material and all surplus excavated material not
required shall be removed from the site. The location of
dump and length of haul shall be the Contractors
responsibility
3. Provide and place any additional fill material from off the
site as may be necessary to produce the grades required.
Fill obtained from off -site shall be of kind and quality as
specified for fills herein and the source approved by the
Owner
4. The Contractor shall accept the site as he finds it and shall
remove all trash, rubbish and debris from the site before
excavation starts
B. Work not included: The following items of related work are
specified and included in other sections of these
specifications:
1. Excavation, grading and backfilling for utility lines
2. Storm drainage systems
3. Sanitary sewer systems
4. Streets and paving
5. Water supply system
2. BENCH MARKS
Maintain carefully as/ bench marks, monuments and other
reference points; If disturbed or destroyed, contractor shall
contact engineer and surveyor.
3. REMOVAL OF TREES
A. Remove all trees and stumps from area to be
occupied by road and surfaced areas. Removal of
trees outside these areas shall only be done as
noted on drawings or approved by the Owner.
B. All brush, stumps, wood and other refuse from the
trees shall be removed to disposal areas off -site.
Disposal by burning shall not be permitted unless
proper permits are obtained (where applicable).
4. PROTECTION OF TREES
A. General Protection: The Contractor shall be
responsible for the protection of tops, trunks and
roots of existing trees on the project site that are
to remain. Existing trees subject to construction
damage shall be boxed, fenced or otherwise
protected before any work is started; do not
stockpile within branch spread. Remove Interfering
branches without injury to trunks and cover scars
with tree paint.
5. HANDLING OF TOPSOIL
A. Remove all organic material from the areas to be
occupied by buildings, roads, walks and parking
areas. Pile and store topsoil at a location where it
will not interfere with construction operations.
Topsoil shall be reasonably free from subsoil,
debris. weeds, grass, stones, etc.
B. After completion of site grading and subsurface
utility installation, top soil shall be replaced in
areas designated on the erosion control plan for
seeding and /or sodding. Any remaining top soil
shall be used for finished grading around
structures and landscaping areas.
6. DISPOSITION OF UTILITIES
A. Rules and regulations governing the respective
utilities shall be observed in executing all work
under this section.
B. If active utilities are encountered but not shown
on the drawings, the Engineer shall be advised
before work Is continued.
C. Inactive and abandoned utilities encountered in
excavating and grading operations shall be
reported to the Engineer. They shall be removed,
plugged or capped as directed by the Utility
Company or the Engineer.
D. It shall be the responsibility of each contractor to
verify all existing utilities and conditions pertaining
to his phase of the work. It shall also be the
contractors responsibility to contact the owners of
the various utilities before work is started.
7. SITE GRADING
A. Grades: Contractor shall perform all cutting,
filling, compacting of fills and rough grading
required to bring entire project area to grade as
shown on the drawings.
B. Rough Grading: The tolerance for paved areas
shall not exceed 0.10 feet plus or minus above th
eestablished subgrade. All other areas shall not
exceed 0.10 feet plus or minus the established
grade. All banks and other breaks in grade shall be
rounded at top and bottom.
C. Compaction Requirements:
1. All engineered fill beneath floor slab -on-
grade floors and over footings should be
compacted o dry density of at least 90
percent of the Proctor maximum dry
density (ASTM D- 1557). This minimum
compaction requirement should be
increased to 95 percent for fill
supporting footings.
2. In cut areas, where pavement sections
are planned the upper 10 In. of subgrade
should be scarified and compacted to a
dry density of at least 95 percent of the
modified Proctor maximum dry density
(ASTM D- 1557). Any grade raised fill
placed within 1 ft of the base of the
pavement section should also
compacted to at least 95 percent of the
modified Proctor maximum dry density.
This can be reduced to 90 percent for
engineered fill placed more than 1 ft
below the base of the pavement section.
3. The compaction should be accomplished
by placing the fill in about 8 In. Loose
lifts and mechanically compacting each
lift too at least the specified minimum
dry density. Field density tests should be
performed on each lift as necessary to
Insure that adequate compaction is
being achieved.
4. As a minimum, all earthwork fill shall be
compact to 90 percent of standard
Proctor maximum dry density if not
specified specifically in these
specifications or In the soils report.
8. TESTING AND INSPECTION SERVICE
Contractor shall employ and pay for a qualified independent
geotectnical testing laboratory to perform soil testing and
Inspection service earthwork operation. Scope of testing and
inspection shall be approved by the engineer prior to
earthwork operations.
SANITARY SEWER SYSTEMS
1. Standard specifications of the District and Indiana Department of
Transportation shall apply for all work and materials. Pipe shall
be installed in accordance with Section 715.
2. Sanitary sewer pipe shall be PVC in accordance with ASTM D -3034
(S.D.R. 35) and ASTM 2321. PVC pipe shall have grooved bell
and gasket. The pipe shall be made of PVC plastic having a cell
classification of ASTM 124548.
3. PVC sewer fittings shall conform to the requirements of ASTM
D- 3034 -89 specification. Fittings in sizes through 8" shall be
molded in one place with elastomeric joints and minimum socket
depths as specified in sections 6.2 and 7.3.2. Fittings 10" and
larger shall be molded or fabricated in accordance with section
7.11 with manufacturers standard pipe bells and gaskets. Wall
thickness of fittings shall be SDR 26 as defined in section 7.4.1
of specifications. Gaskets for elastomeric joints shall be molded
with a minimum cross - sectional area of 0.20 square inches and
conform to ASTM F -477 specification.
4. All sanitary manholes shall be precast concrete manholes in
accordance with ASTM C -478 and Section 720. 0 -rings shall
conform to C -443. Kent Seal or equivalent shall also be applied
to all joints and between riser rings and castings. Manhole step
spacing shall be no more than 16- inches. Manholes shall be air
tested for leakage in accordance with ASTM C1244 -93, Standard
Test Method for Concrete Sewer Manholes by the Negative Air
Pressure (Vacuum) Test.
A. Installation and operation of vacuum equipment and indicating
devices must be in accordance with manufacturer's
recommendations and performance specifications which have
been provided by the manufacturer and accepted by the Engineer.
The vacuum equipment must be capable of testing the entire
manhole, including the casting and riser rings.
B. With the vacuum tester set to place:
1. Connect the vacuum pump to the outlet port with the valve
open.
2. Draw a vacuum of ten (10) inches of Hg. and close the valve.
C. Accepted standards for leakage will be established from the elapsed
time for a negative pressure change from ten (10) inches to nine
(9) Inches of mercury. The maximum allowable leakage rate for a
four (4) foot diameter manhole must be in accordance with
the following:
Minimum Elapsed Time for a
Manhole Depth Pressure Change of 1 Inch Ha
10 feet or less 60 seconds
>10 feet but <15 feet 75 seconds
>15 feet but <25 feet 90 seconds
For manholes five (5) feet in diameter, add an additional fifteen (15)
seconds and for manholes six (6) feet to diameter, add an additional
thirty (30) seconds to the time requirements for four (4) foot diameter
manholes. For all manholes deeper than twenty -five (25) feet, the
Engineer will determine the applicable minimum elapsed time.
D. If the manhole fails the test, necessary repairs must be made
and the vacuum test and repairs must be repeated until the
manhole passes the test.
E. If manhole joint sealants are pulled out during the vacuum test,
the manhole must be disassembled and the joint sealants replaced.
F. Manholes will be subject to visual inspection with all visual leaks
being repaired.
5. Butyl rubber coating shall be applied around each manhole joint from
6- inches above to 6- inches below each joint. The appropriate primer
shall be applied prior to applying the rubber coating. Inside joints to
be filled with precoat plug material.
6. The manhole chimneys, including all riser rings shall be sealed using
Infi- Shield Uniband or approved equal. Prior to placement, the top
4- inches of the manhole cone and casting frame shall be cleaned
and primed. The Uniband shall extend from 3- inches below the top
of the cone section to 2- inches over the flange of the manhole
casting frame.
7. The casting elevations are set by plan. However, the castings are to
be adjusted in the field by the Engineers representative should a
discrepancy occur between plan grade and existing grade. New manhole
ring and cover shall be installed to establish grade. Maximum height
of adjusting rings shall be 12- Inches.
8. Backfill around all structures and all cuts under paved areas with
granular material. Trenches opening within 5 -feet of paved roadways
shall be backfilled with granular material in accordance with Section
211. Backfill under sidewalks shall be granular, unless the walks are
constructed a minimum of 6 months after backfill has been in place.
9. The Contractor shall be responsible for verifying that all state highways,
city, and county permits have been obtained by the developer prior
to start of construction.
10. The Contractor shall be required to furnish the developer's Engineer
with a set of prints, marked in red pencil, showing actual sewer location
and invert, to include lateral location, depth and length. The sanitary
sewer laterals and stubs termination shall be indicated on the surface
with a metal fence post set immediately above the said termination point.
11. All sanitary sewer lines upon completion will be required to pass a low
pressure air test. Said test shall be conducted according to ASTM 1417 -92,
and shall be witnessed by an Engineer and a representative of the District.
12. Deflection tests shall be performed on all flexible* pipe after the final
backfill has been in place at least 30 days. No pipe shall exceed a vertical
deflection of 5% deflection test results. ( *The following are considered non -
flexible pipes: concrete pipe, ductile iron pipe, and cast iron pipe). The
deflection test shall be performed without the aid of a mechanical pulling
device. Proving rings shall be available.
13. A professional engineer representative for certification and a representative
of the District shall observe all mandrel testing.
14. The ends of laterals are to be plugged tight with a braced plastic disc or
cap capable of withstanding a low pressure air test without leakage.
15. Bedding for flexible pipe shall be No. 8 crushed stone from 6- inches
below the pipe to 12- inches above the pipe. Bedding for rigid pipe shall
be No. 8 crushed stone from 6- inches below the pipe to the spring line
of the pipe and from this point to 12- inches above shall be fill sand or
equivalent. Manholes shall be placed on no less than 6- inches of No. 8
crushed stone bedding.
16. Water and sewer line crossings and separations shall be in accordance
with 327 IAC 3 -6 -9.
17. Trench shall be opened sufficiently ahead of pipe laying to reveal
obstruction, and shall be properly protected and /or barricaded when left
unattended.
18. No water shall be permitted to flow into the sanitary sewer system
during construction. Contractor shall utilize a pump to keep the water
level below the pipe. Pump discharge shall be directed to a storm
outlet in accordance with state and federal laws and regulations
(327 IAC 3- 6 -20). Any pipe entering existing sewers shall be plugged
with screw type mechanical, braced plug until such time as all tests
on the sewers have been completed and the lines have passed all punch lists.
19. All sewer laterals installed by the mainline Contractor shall be bedded
the some as the main line sewer.
20. Forty -eight (48) hours notice shall be given to the District prior to
the start of sewer construction. Also, 48 hours notice shall be gliven
prior to doing any testing on the sewer.
21. Manhole castings shall be stamped SANITARY SEWER (Neenah Casting
R -1642A or equal) and be self - sealing type. The casting flange shall
be 34 inches and the clear opening shall be 24 inches. Waterproof
castings shall be Neenah R- 1916 -F1 and stamped SANITARY SEWER.
22. The minimum slope for sewer acceptance are:
Size of Pipe Minimum Constructed Slope
8 -inch 0.40%
10 -inch 0.28%
12 -inch 0.22%
15 -inch 0.15%
18 -inch 0.12%
23. The Contractor shall provide measurements of the slope of the sewer
for each manhole section as construction progresses. Such measurements
shall be certified by a Registered Land Surveyor or Engineer and be
available on -site for observation by the District's Inspector. No more
than three manhole sections can be constructed in advance of such
measurements.
24. In the event the Contractor does not most the minimum slopes, the
sewer section and any other ffected sewer sections shall be recionstructed
to meet such minimum slopes.
25. Laterals are to be traced with a minimum size of 14 gauge wire
from the wye to the terminus. The contractor for the building or home
will extend the wire from this terminus to the building cleanout adjacent
to the building.
26. Sanitary sewers shall not be located within ten (10) feet of any existing
or proposed water mains, when measured horizontally from the outside
edge of the sanitary sewer to the outside edge of any existing land
proposed water mains, unless the sanitary sewers and the water main
comply with the following:
(1) The sanitary sewer and water main must cross with the sanitary
sewer and water main separated by a minimum of eighteen (18)
inches measured vertically from the outside edge of the sanitary
sewer to the outside edge of the water main.
(2) The crossing specified In subdivision (1) must be at a minimum
angle of forty -five (45) degrees measured from the center lines
of the sanitary sewer and water main.
(3) The conditions specified in subdivisions (1) and (2) must be
maintained for a minimum distance of ten (10) feet from either
side of the sanitary sewer as measured from the outside edge of
the sanitary sewer to the outside edge of the water main.
STORM SEWER SYSTEMS
1. SCOPE OF WORK
The work under this section includes all storm sewers, storm
water inlets, and related items including excavating and
backfilling necessary to complete the work shown on the
drawings.
2. MATERIALS
A. Storm Sewers
Reinforced concrete sewer pipe shall conform to ASTM C -76
latest revision„ with joints conforming to ASTM C -443
latest revision..
B. Roof /Downspout Connections
All gravity plastic storm sewer pipe and fittings shall
conform to ASTM D -3034, SDR -35 and meet a cell
classification of 12454 -C. Flexible gasketed compression
joints shall be used for PVC. No solvent cement joints
shall be allowed.
C. Manholes
1. Precast reinforced concrete manhole sections and
steps shall conform to ASTM C -478 latest revision.
2. Casting shall be of uniform quality, free from blow
holes, porosity, hard spots, shrinkage distortion,
or other defects. They shall be smooth and well
cleaned by shot - blasting or by some other approved
method. They shall be coated with asphalt paint,
which shall result in a smooth coating, tough and
tenacious when cold, not tacky or brittle. They
shall be gray iron meeting ASTM A -48 latest
revision.
3. Joints - Manhole sections shall be jointed with
rubber type gaskets. The rubber type gaskets shall
meet ASTM C -443 latest revision. When manhole and
storm pipe are continuously in water.
D. Subdrains
Perforated plastic pipe subdrains shall conform to ASTM
F -405, AASHTO M -252 (4" to 10" pipe).
3. APPLICATION
A. Permits and Codes - The intent of this section of the
specifications is that the contractor's bid on the work
covered herin shall be based upon the drawings and
specifications, and that the work shall comply with all
applicable codes and regulations as amended by any
waivers. Contractor shall furnish all bonds necessary to
get permits for cuts and connections to existing sewers.
B. Local Standards - The term "Local Standards" as used
herin means the standards of design and construction of
the respective municipal department or utility company.
C. Existing Improvements - Maintain in operating condition
all active utilities, sewers, and other drains
encountered in the sewer installation. Repair to the
satisfaction of the owner any damage to existing active
improvements.
D. Workmanship - To conform to all local, state, and
national codes and to be approved by all local and state
agencies having jurisdiction.
E. Trenching - Lay all pipe in open trenches, except when
the local authority gives written permission for
tunneling. Open the trench sufficiently ahead of
pipelaying to reveal any obstructions. The width of the
trench shall be the inside pipe diameter plus 24 inches
for 12 inches above the pipe. Sheet and brace trench as
necessary to protect workmen and adjacent structures. All
trenching to comply with Occupational SAfety and Health
Administration Standards. Keep trencnes free from water
while construction is in progress. Under no circumstances
lay pipe or appurtenances in standing water. Conduct the
discharge from trench dewatering to drains or natural
drainage channels.
F. Special Supports - Whenever in the opinion of the
engineer the soil at or below the pipe grade is
unsuitable for supporting sewers and appurtenances
specified in this section, such speci:.i support, in
addition to those shown or specified, shall be provided
as the engineer may direct, and the contract will be
adjected.
G. Backfilling - For a depth of at least 12 inches above the
top of the pipe, backfill with earth or granular material
free from large stones, rock frogr^.::as, roots, or sod.
Tamp this backfill thoroughly, taking care not to disturb
the pipe. For the remaining trench depth, backfill with
earth or granular material containing stones or rocks not
larger than 4 inches. Backfill under Sd within 5' of
walks, parking areas, driveways, and street shall be
granular material only - thoroughly compacted by approved
methods.
H. Manhole Inverts - Construct manhole flow channels of
concrete sewer pipe or brick, smoothly finished and of
semi - circular section conforming to the inside diameter
of the connecting sewers. Make changes in size or grade
gradually and changes in direction by true curves.
Provide such channels for all connecting sewers at each
manhole.
I. Subdrains - All subdrains shall be of the size shown on
the pland and shall be constructed to the grades shown.
All drains constructed off -site as part of the outlet
drain will be located as shown.
J. Utilities - It shall be the responsibility of each
contractor to verify all existing utilities and
conditions pertaining to his phase of the work. It shall
also be the contractors responsibility to contact the
owners of the various utilities before work is started.
The contractor shall notify in writing the owners or the
engineer of any changes, errors, or omissions found on
these plans or in the field before work is started or
resumed.
SEEDING
1. Planting Time: Do not plant seed on frozen soil. Do not perform seeding when
wind exceeds 15 mph. Do not seed between calendar dated from November
15 to March 1 or from June 1 to September 1.
2. Protect seeded areas against erosion by spreading anti - erosion mulch after
completion of seeding operations. Spread uniformly to form a continuous
blanket not less than 1h" loose measurement over seeded areas.
3. Anchor mulch by spraying with asphalt emulsion at the rate of 10 to 13 gallons
per 1000 sq. ft. Take precautions to prevent damage or staining or
construction or other plantings adjacent to mulched areas.
4. SCHEDULE OF GRASS SEED MIXTURE
Mixture For sunny to partial shade areas:
Proportion
Min.%
By Weight Common Name
45%
Kentucky
Germ.
Bluegrass
30%
Chewings
85
Red Fescue
20%
Perennial
98
Ryegrass
5%
Redtop
5. Sowing Rate: Sow grass seed at the following rate - 200 Ibs /acre.
STREETS do PAVEMENT
1. SCOPE OF WORK
The work required under this section includes all concrete and
bituminous paving and related items necessary to complete the
work indicated on drawings and described in the
specifications, including, but not limited to:
All streets, parking areas in contract limits
Curbs and gutters
Sidewalks and concrete slabs, exterior steps
MATERIALS
3.
4.
5.
The following formula shall be used to determine the amount of
commercial seed required to provide in each kind of seed the specified
quantities of pure live seed.
Pure Live Seed x 100% x 100% = Pounds Commercial
Purity x Germination Seeds Required 6•
6. Commercial Fertilizer: Complete fertilizer of neutral character, with some
elements derived from organic sources and containing following percentages
of available plant nutrients. For lowns,provide fertilizer with percentage of
nitrogen required to provide not less than 1 lb. of actual nitrogen per 100 sq.ft.
of lawn area, and not less than 4% phosphoric acid and 2% potassium. Provide
nitrogen in a form that will be available to lawn during initial period of growth;
at least 50% of nitrogen to be organic form.
A. Concrete - Concrete shall be ready - -mixed concrete and
shall be a mix of proportioned fine and coarse aggregates
with Portland cement and water. Minimum cement content
shall be 6 bags per cubic yard of concrete and maximum
water content shall be 5.5 U.S. gallons per sack of cement,
Including moisture in the aggregate. Slump for normal
weight concrete shall be a maximum of 4 inches and a
minimum of 2 inches the slump of machine placed concrete
shall be no less than 1 -1/4 inches nor more than 3 inches
Standard test C -143 shall be used to measure slump.
Compressive strength of concrete at 28 days shall be 4000
psi. All exterior concrete shall have air entrainment of 5%
to 8% by volume per ASTM C -260. Retempering of
delivered concrete will not be allowed. Concrete shall be
composed of:
1. Portland cement - Conforming, to ASTM Type IA
or Type IIIA.
2. Aggregates Conforming to ASTM C -33
3. Water - Shall be clear and free from injurious
amounts of oils, acids, alkalizes, organic materials
or other deleterious substances.
B. Welded Steel Wire Fabric - Where required for concrete
reinforcement shall conform to ASTM A185.
C. Premoulded Joint Filler - Shall be of non - extruding type
meeting ASTM D -544 except premoulded pint filler used In
concrete walk construction may be either non - extruding or
resilient.
D. Bituminous Pavement Materials - All materials proposed for
the construction of bituminous pavements shall comply
with the Indiana Department of Transportation
specifications, per latest revision.
E. Compacted Aggregate Subbase: Shall be crushed stone or
gravel. Crushed gravel shall be a minimum of 35% crushed
material. Chert shall be limited to a maximum of 8% of the
total. Material shall be free from an excess of flat,
elongated thinly laminated, soft or disintegrated pieces; and
shall be free from fragments coated with dirt. Compacted
aggregate shall be graded as follows:
SIEVE SIZE % PASSING
1--1/2" 100
1" 80 -100
3/4" 70 -90
1/2" 55 -80
14 35 -60
#8 25 -50
130 12- 30
X1200 5 -0
APPLICATION
A. Grading - Do any necessary grading in addition to that
performed in accordance with Earthwork Section, to bring
subgrades, after final compaction, to the required grades
and sections for site improvement.
B. Preparation of Subgrade - Remove spongy and otherwise
unsuitable material and replace with stable material. No
traffic will be allowed on prepared subgrade prior to paving.
C. Utility Structures - Check for correct elevation of all
manhole covers, valve boxes and similar structures located
within areas to be paved, and make, or hove made, any
necessary adjustments in such structures.
D. Placing Concrete
1. Subgrade - Place concrete only on ganual material,
compacted subgrade or base free from loose
material. Place no concrete on a muddy or frozen
subgrade -
2. Forms - All forms shall be free from warp, tight
enough to prevent leakage and substantial
enough to maintain their shape and position
without springing or settling, when concrete is
placed Forms shall be clean and smooth
immediately before concreting
3. Placing Concrete - Concrete shall be deposited so
as to require as little rehandling, as practicable.
When concrete is to be placed at an atmospheric
temperature of 35 degrees F or less, paragraph
70210 of the Indiana Department of
Transportation Specifications latest revision shall
be followed.
E. Concrete Curb
1. Expansion joints - Shall be 1/2 inch thick
premoulded at ends of all returns and at a
maximum spacing of 40 feet.
2. Contraction Joints - Unless otherwise provided,
contraction joints shall be sawed joints spaced 10
feet on center.
3. Finish - Tamp and screed concrete as soon a
placed and fill any honey combed places. Finish
square comers to 1/4" radius and other corners
to radii shown.
F. Concrete Walks and Exterior Steps
1. Slopes - Provide 1/4 Inch per foot cross slope.
Make adjustments in slopes at walk intersections
as necessary to provide proper drainage.
2. Dimensions - Walks and steps shall be one course
construction and of widths and details shown on
the drawings
3. Finish - Screed concrete and trowel with a steel
trowel to a hard dense surface after Surface
water has disappeared. Apply medium broom
finish and scribe control joints at 5 foot spacing
Provide 1/2" expansion joints where sidewalks
intersect, and at a maximum spacing of 48 feet
between expansion pints.
G. Curing Concrete -- Except as otherwise specified, cure all
concrete by one of tho methods described in Section 501
17 of the Indiana Department of Transportation
Specifications, latest revision.
H. Concrete Curing Compound - All exterior concreto shall be
coated with curing compound complying with ASTM C
309, TYPE 1 -D, class A.
J. Concrete Testing - Concrete testing shall meet the
requirements established for structural concrete to be used
in building on this site
HERBICIDE TREATMENT
A. Provide and apply commercial chemical for weed control In
paved areas Chemical shall be registered by the
environmental protection agency and supplied In granular,
liquid or wettable powder form.
B. Apply according to manufactures specifications.
WHEEL STOPS
A. Wheel Stops - 2,500 -psi compressive strength precast, air -
entrained concrete, approximately 6 inches high a inches
wide, and 7 feet long. Provide chamfered corners and
drainage slots on underside.
PAVEMENT MARKING PAINT
A. Pavement Marking Paint - Alkyd -resin type, ready -mixed
complying with AASHTO M 248, TYPE 1.
B. Color shall be white unless noted otherwise, except for
handicapped spaces and access ways which shall be blue.
7. FIELD QUALITY CONTROL
A. General - Testing in -place hot -mixed asphalt courses for
compliance with requirements for thickness and surface
smoothness. Repair or remove and replace unacceptable
paving. Shall be done by an independent testing laboratory
with scope of testing and inspection approved by engineer.
B. Thickness - In -place compacted thickness tested In
accordance with ASTM D 3549 will not be acceptable If
exceeding following allowable variation: prepared subgrade
prior to paving.
1. Binder Course: Plus or minus 1/2 inch.
2. Surface Course: Plus or minus 1/4 inch.
C. Surface Smoothness - Test finished surface of each
hot -mixed asphalt course for smoothness, using 10-
foot straightedge applied parallel with and at right
angles to centerline of paved area. Surfaces will not
be acceptable if exceeding the following tolerances
for smoothness.
1. Binder Course Surface: 1/4 inch.
2. Wearing Course Surface: 3/16 inch.
WATER MAINS
1. SCOPE OF WORK
If not specified below, fire protection and watermains are to be
laid in accordance with the specifications of the Indianapolis
Water Company, or as directed by the Department of Public
Works for the City of Indianapolis. The work required under this
section includes all cold water distribution lines, valves, meter
pits, hydrants, and related items including excavating and
backfilling necessary to complete the work shown on the
drawings. The ends of water service lines shall be tightly
plugged or capped at the terminal points pending the
connecting to all such lines of the building piping as specified
In the plumbing specifications and architectural drawings.
2. IRON PIPE
Cast iron pipe shall meet A Specification C -106 with push -
on joints meeting A Specification C -111. Wall thickness
shall be determined from Table 6.4 in A C -106. Ductile iron
pipe shall meet A C -150 and C -151 Specifications. Pipe to
be cement lined and seal coated in accordance with A C-
104. Joints shall be pushed -on type, Teuton, Fasted, Super
Bell -Tete, or approved equal, except at fittings, valves and
special crossings. Joints shall comply with A C -111.
Fanged joints shall conform to ASA A21.10 or B16.1.
3. Polyethylene ( "PE ") Pipe
A. Materials
1. Materials used for the manufacture of PE pipe and
fittings must be extra high molecular weight, high
density PE 3408 polyethylene resin. The pipe must be
extruded from virgin resin meeting the specifications
of ASTM D 3350 with a minimum cell classification of
PE 345434C. Fittings must be manufactured from
the some resin type and cell classification as the
pipe itself.
2. The pipe and fittings must contain no recycled
compound except that generated in the
manufacturer's own plant from resin of the some
raw material.
3. The material must be listed by PPI ( "Plastics Pipe
Institute ", a division of the Society of the Plastics
Industry) in its pipe grade registry technical report
(TR4) with a seventy -three (73) degree Fahrenheit
hydrostatic design basis of one thousand six hundred
(1,600) psi and a one hundred forty (140) degree
Fahrenheit hydrostatic design basis of eight hundred
(800) psi.
4. The manufacturer must conform to ISO 9001.
B. Pipe and Fittings
1. Pipe supplied under this specification must have a
nominal iron pipe sire outside diameter.
2. Pipe having a diameter of three (3) inches and
larger must be made to the dimensions and
tolerances specified in ASTM F714 with a cell class of
PE 345434C. Pipe with diameters less than three (3)
inches must be made to the dimensions and
tolerances set forth in ASTM D 3035 with a cell class
of PE 3408
3. Fittings must be manufactured in accordance with
ASTMD 3261. Fittings must be manufactured by
injection molding, a combination of extrusion and
machining, or fabricated from PE pipe conforming to
this specification.
4. Fittings must be fully pressure rated and provide a
working pressure equal to that of the adjacent pipe
with an included two (2) to one (1) safety factor.
5. The pipe and fittings must be homogeneous
throughoutand free of visible cracks, holes, voids,
foreign inclusions, or other defects that may affect
the wall integrity.
6. The pipe and fittings for horizontal directional drilling
must be a minimum DR of 9. Pipe and fittings used
In open cut nstallations must be a minimum of DR
11.
C. Joints
1. No person may join PE pipe unless Engineer has
approved that person.
2. The butt fusion process should be used to join
sections of PE pipe into continuous lengths at the job
site. The joining method must be by the heat fusion
method and must be performed in strict accordance
with the pipe manufacturer's recommendations. The
heat fusion equipment used in the joining procedures
must be capable of meeting all conditions
recommended by the pipe manufacturer.
3. Properly executed electrofusion fittings may be used.
4. Extrusion welding, hot gas welding or threading and
gluing of PE pipe will not be accepted.
5. MJ adapters are required to mechanically connect PE
pipe tomain line valves three (3) inches or larger.
Two (2) inch valves and smaller must be connected
by compression fittings.
6. Refer to the manufacturer's recommendations for
proper installation procedures.
7. Fused segments of pipe must be handled so as to
avoid damage to the pipe. Chains or cable type
chokers must be avoided when lifting fused sections
of pipe. Nylon slings are preferred. Spreader bars are
recommended when lifting long fused sections.
D. Precautions
1. During the heat fusion process the equipment and
pipe product may reach temperatures in excess of
four hundred (400) degrees Fahrenheit. Caution
should be taken to prevent burns.
2. Static electricity charges are generated on PE pipe by
friction, particularly during the handling of pipe in
storage, shipping and installation. The flow of air or
gas containing dust or scale will also build up
significant static charges, as will the flow of dry
materials through the pipe. These charges are a
safety hazard, particularly in areas where there is
leaking gas or a flammable /explosive atmosphere.
3. Coiled PE pipe may contain energy as in a spring.
Uncontrolled release by cutting straps, etc. can result
in dangerous uncontrolled forces. Exercise appropriate
safety precautions and use proper equipment.
4. PE pipe is impact resistant. Any hitting of the pipe
with an instrument, such as a hammer, may result in
uncontrolled rebound.
E. All final connections to Lift Station /Force Main Manholes
must not be completed until all PE materials have reached
equilibrium conditions (average ground temperature, etc.).
4. FITTINGS
Fittings shall be cast iron of ductile iron conforming to ANSI
Specification ABBE.10 -1971 (A C110 -71). Fittings shall be
designed and manufactured for a pressure rating of 250
psi. Fittings shall be tar coated and shall be cement lined
in accordance with ANSI Specification ABBE.4 1974 (A C104 -
74). Fittings joints shall be mechanical joints conforming to
ANSI Specification ABBE.11 -1972 (A C11 -72).
5. COPPER TUBING
Shall be seamless, annealed copper tubing complying with
Federal Specification WW -T -799. Fittings shall be wrought
copper or cast bronze with solder joints. Solder shall be of
a composition recommended by the manufacturer of the
fittings.
6. FIRE HYDRANTS
Shall comply with A Specification C -502 and shall meet local
standards and requirements, particularly as to nozzle
diameters and threads, direction of opening and dimensions
of operating and cap nuts. Fire hydrants shall have one
pumper and two hose nozzles. A valve opening not less than
5 inches and a 6 inch inlet connection. The length of the
hydrant barrel shall be determined by the specified depth of
cover over the pipe. All private water hydrants are to be
painted a color other than that utilized by the Water
Company. Hydrants shall be located such that the direction of
opening is directed towards the street.
7. VALVES
All valves and stops shall have ends suited or adapters shall be
provided for the proper installation in the lines in which they
are located. Valves shall meet local standards or in the
absence of such standards, the following requirements:
A. Valves in cast iron pipe shall be iron body, bronze
mounted, disc gate valves conforming to A Specification C-
500. They shall open in the some direction as those used
In the local waterworks system. Valve stems shall
terminate in 2 inch wrench nuts. Furnish two (2) keys.
B. Valves in copper pipe shall be standard brass body,
round -way, ground -key stops, with T heads. Furnish two
(2) keys.
8. VALVE BOXES
Shall meet local standards or in the absence of such, shall
comply with the following requirements:
A. For iron body valves, boxes shall be approved standard
buffalo -type cast iron, adjustable shaft boxes, having a
minimum shaft diameter of !� inches.
B. For Brass body valves (stops) boxes shall be approved
standard cast iron extension service boxes, having a
minimum diameter of 2 1/2 inches and having lid held in
place by a brass or bronze bolt. The castings shall be
coated with two coats of coal -tar pitch varnish. Furnish
two (2) keys for bolt in lids.
9. STOPS
Stops shall be those manufactured by Ford or Mueller
Corporation with A taper thread, and with copper compression
type fitting on outlet, or approved equal.
10. BLOW -OFF VALVES
Blow -off valves shall be those manufactured by Mueller
Corporation (H10283 of H- 10291) or approved equal.
11. ANGLE VALVES
Angle valves at the end of water service stub are to be
copper compression type fitting, and are to be protected with
plastic bag over the valve.
12. TAPS
1 inch taps in lines smaller than 4 inches shall be only by
tapped tee or tapped saddle. Water service lines should be
marked on curbs with blue paint (sewer lateral locations -
red). Taps onto existing main shall be performed in
accordance with rules of the Water Company having
jurisdiction.
13. DEPTH
The Water Mains shall be laid to a depth not less then five
feet (5' -0 ") below ground cover.
14. METER PITS
The Contractor shall furnish the meter pit(s) and vault of the
type as shown on the construction plans (meter to be
furnished by Water Company) along with all necessary quick -
disconnects, valves and appurtenances. This cost shall be
included in the bid amount for water lines. Meter pits must
be equipped with storm sewer drain or sump connected to
storm structure.
15. TESTS
Test the piping for leakage for a period of at least two hours
at a pressure of 150 pounds per square inch. Inspect all
joints for leakage and remedy any leaks. Upon completion of
the water distribution mains, flush out the system until the
water runs clears. As soon as the system has been flushed
out, it shall be sterilized in accordance with the requirements
of the local water department.
``%ttJeiie1e01toI
. •'GISTE••� �•...�HOC
. I moo'••. c� ,
_ N0. 1.
910326
10 STATE OF • �
F^ . D I•A
ONAL
1ii11
� - - - ;04_L_.,
Min.%
Min.%
Max.%
Botanical Name
Germ.
Pure Sd. Weed Sd.
Poo protensis
80
85
0.50
Festuca rubro
85
98
0.50
Lolium Perenne
90
98
0.50
'Pennfine'
Agostis alba
85
92
1.00
5. Sowing Rate: Sow grass seed at the following rate - 200 Ibs /acre.
STREETS do PAVEMENT
1. SCOPE OF WORK
The work required under this section includes all concrete and
bituminous paving and related items necessary to complete the
work indicated on drawings and described in the
specifications, including, but not limited to:
All streets, parking areas in contract limits
Curbs and gutters
Sidewalks and concrete slabs, exterior steps
MATERIALS
3.
4.
5.
The following formula shall be used to determine the amount of
commercial seed required to provide in each kind of seed the specified
quantities of pure live seed.
Pure Live Seed x 100% x 100% = Pounds Commercial
Purity x Germination Seeds Required 6•
6. Commercial Fertilizer: Complete fertilizer of neutral character, with some
elements derived from organic sources and containing following percentages
of available plant nutrients. For lowns,provide fertilizer with percentage of
nitrogen required to provide not less than 1 lb. of actual nitrogen per 100 sq.ft.
of lawn area, and not less than 4% phosphoric acid and 2% potassium. Provide
nitrogen in a form that will be available to lawn during initial period of growth;
at least 50% of nitrogen to be organic form.
A. Concrete - Concrete shall be ready - -mixed concrete and
shall be a mix of proportioned fine and coarse aggregates
with Portland cement and water. Minimum cement content
shall be 6 bags per cubic yard of concrete and maximum
water content shall be 5.5 U.S. gallons per sack of cement,
Including moisture in the aggregate. Slump for normal
weight concrete shall be a maximum of 4 inches and a
minimum of 2 inches the slump of machine placed concrete
shall be no less than 1 -1/4 inches nor more than 3 inches
Standard test C -143 shall be used to measure slump.
Compressive strength of concrete at 28 days shall be 4000
psi. All exterior concrete shall have air entrainment of 5%
to 8% by volume per ASTM C -260. Retempering of
delivered concrete will not be allowed. Concrete shall be
composed of:
1. Portland cement - Conforming, to ASTM Type IA
or Type IIIA.
2. Aggregates Conforming to ASTM C -33
3. Water - Shall be clear and free from injurious
amounts of oils, acids, alkalizes, organic materials
or other deleterious substances.
B. Welded Steel Wire Fabric - Where required for concrete
reinforcement shall conform to ASTM A185.
C. Premoulded Joint Filler - Shall be of non - extruding type
meeting ASTM D -544 except premoulded pint filler used In
concrete walk construction may be either non - extruding or
resilient.
D. Bituminous Pavement Materials - All materials proposed for
the construction of bituminous pavements shall comply
with the Indiana Department of Transportation
specifications, per latest revision.
E. Compacted Aggregate Subbase: Shall be crushed stone or
gravel. Crushed gravel shall be a minimum of 35% crushed
material. Chert shall be limited to a maximum of 8% of the
total. Material shall be free from an excess of flat,
elongated thinly laminated, soft or disintegrated pieces; and
shall be free from fragments coated with dirt. Compacted
aggregate shall be graded as follows:
SIEVE SIZE % PASSING
1--1/2" 100
1" 80 -100
3/4" 70 -90
1/2" 55 -80
14 35 -60
#8 25 -50
130 12- 30
X1200 5 -0
APPLICATION
A. Grading - Do any necessary grading in addition to that
performed in accordance with Earthwork Section, to bring
subgrades, after final compaction, to the required grades
and sections for site improvement.
B. Preparation of Subgrade - Remove spongy and otherwise
unsuitable material and replace with stable material. No
traffic will be allowed on prepared subgrade prior to paving.
C. Utility Structures - Check for correct elevation of all
manhole covers, valve boxes and similar structures located
within areas to be paved, and make, or hove made, any
necessary adjustments in such structures.
D. Placing Concrete
1. Subgrade - Place concrete only on ganual material,
compacted subgrade or base free from loose
material. Place no concrete on a muddy or frozen
subgrade -
2. Forms - All forms shall be free from warp, tight
enough to prevent leakage and substantial
enough to maintain their shape and position
without springing or settling, when concrete is
placed Forms shall be clean and smooth
immediately before concreting
3. Placing Concrete - Concrete shall be deposited so
as to require as little rehandling, as practicable.
When concrete is to be placed at an atmospheric
temperature of 35 degrees F or less, paragraph
70210 of the Indiana Department of
Transportation Specifications latest revision shall
be followed.
E. Concrete Curb
1. Expansion joints - Shall be 1/2 inch thick
premoulded at ends of all returns and at a
maximum spacing of 40 feet.
2. Contraction Joints - Unless otherwise provided,
contraction joints shall be sawed joints spaced 10
feet on center.
3. Finish - Tamp and screed concrete as soon a
placed and fill any honey combed places. Finish
square comers to 1/4" radius and other corners
to radii shown.
F. Concrete Walks and Exterior Steps
1. Slopes - Provide 1/4 Inch per foot cross slope.
Make adjustments in slopes at walk intersections
as necessary to provide proper drainage.
2. Dimensions - Walks and steps shall be one course
construction and of widths and details shown on
the drawings
3. Finish - Screed concrete and trowel with a steel
trowel to a hard dense surface after Surface
water has disappeared. Apply medium broom
finish and scribe control joints at 5 foot spacing
Provide 1/2" expansion joints where sidewalks
intersect, and at a maximum spacing of 48 feet
between expansion pints.
G. Curing Concrete -- Except as otherwise specified, cure all
concrete by one of tho methods described in Section 501
17 of the Indiana Department of Transportation
Specifications, latest revision.
H. Concrete Curing Compound - All exterior concreto shall be
coated with curing compound complying with ASTM C
309, TYPE 1 -D, class A.
J. Concrete Testing - Concrete testing shall meet the
requirements established for structural concrete to be used
in building on this site
HERBICIDE TREATMENT
A. Provide and apply commercial chemical for weed control In
paved areas Chemical shall be registered by the
environmental protection agency and supplied In granular,
liquid or wettable powder form.
B. Apply according to manufactures specifications.
WHEEL STOPS
A. Wheel Stops - 2,500 -psi compressive strength precast, air -
entrained concrete, approximately 6 inches high a inches
wide, and 7 feet long. Provide chamfered corners and
drainage slots on underside.
PAVEMENT MARKING PAINT
A. Pavement Marking Paint - Alkyd -resin type, ready -mixed
complying with AASHTO M 248, TYPE 1.
B. Color shall be white unless noted otherwise, except for
handicapped spaces and access ways which shall be blue.
7. FIELD QUALITY CONTROL
A. General - Testing in -place hot -mixed asphalt courses for
compliance with requirements for thickness and surface
smoothness. Repair or remove and replace unacceptable
paving. Shall be done by an independent testing laboratory
with scope of testing and inspection approved by engineer.
B. Thickness - In -place compacted thickness tested In
accordance with ASTM D 3549 will not be acceptable If
exceeding following allowable variation: prepared subgrade
prior to paving.
1. Binder Course: Plus or minus 1/2 inch.
2. Surface Course: Plus or minus 1/4 inch.
C. Surface Smoothness - Test finished surface of each
hot -mixed asphalt course for smoothness, using 10-
foot straightedge applied parallel with and at right
angles to centerline of paved area. Surfaces will not
be acceptable if exceeding the following tolerances
for smoothness.
1. Binder Course Surface: 1/4 inch.
2. Wearing Course Surface: 3/16 inch.
WATER MAINS
1. SCOPE OF WORK
If not specified below, fire protection and watermains are to be
laid in accordance with the specifications of the Indianapolis
Water Company, or as directed by the Department of Public
Works for the City of Indianapolis. The work required under this
section includes all cold water distribution lines, valves, meter
pits, hydrants, and related items including excavating and
backfilling necessary to complete the work shown on the
drawings. The ends of water service lines shall be tightly
plugged or capped at the terminal points pending the
connecting to all such lines of the building piping as specified
In the plumbing specifications and architectural drawings.
2. IRON PIPE
Cast iron pipe shall meet A Specification C -106 with push -
on joints meeting A Specification C -111. Wall thickness
shall be determined from Table 6.4 in A C -106. Ductile iron
pipe shall meet A C -150 and C -151 Specifications. Pipe to
be cement lined and seal coated in accordance with A C-
104. Joints shall be pushed -on type, Teuton, Fasted, Super
Bell -Tete, or approved equal, except at fittings, valves and
special crossings. Joints shall comply with A C -111.
Fanged joints shall conform to ASA A21.10 or B16.1.
3. Polyethylene ( "PE ") Pipe
A. Materials
1. Materials used for the manufacture of PE pipe and
fittings must be extra high molecular weight, high
density PE 3408 polyethylene resin. The pipe must be
extruded from virgin resin meeting the specifications
of ASTM D 3350 with a minimum cell classification of
PE 345434C. Fittings must be manufactured from
the some resin type and cell classification as the
pipe itself.
2. The pipe and fittings must contain no recycled
compound except that generated in the
manufacturer's own plant from resin of the some
raw material.
3. The material must be listed by PPI ( "Plastics Pipe
Institute ", a division of the Society of the Plastics
Industry) in its pipe grade registry technical report
(TR4) with a seventy -three (73) degree Fahrenheit
hydrostatic design basis of one thousand six hundred
(1,600) psi and a one hundred forty (140) degree
Fahrenheit hydrostatic design basis of eight hundred
(800) psi.
4. The manufacturer must conform to ISO 9001.
B. Pipe and Fittings
1. Pipe supplied under this specification must have a
nominal iron pipe sire outside diameter.
2. Pipe having a diameter of three (3) inches and
larger must be made to the dimensions and
tolerances specified in ASTM F714 with a cell class of
PE 345434C. Pipe with diameters less than three (3)
inches must be made to the dimensions and
tolerances set forth in ASTM D 3035 with a cell class
of PE 3408
3. Fittings must be manufactured in accordance with
ASTMD 3261. Fittings must be manufactured by
injection molding, a combination of extrusion and
machining, or fabricated from PE pipe conforming to
this specification.
4. Fittings must be fully pressure rated and provide a
working pressure equal to that of the adjacent pipe
with an included two (2) to one (1) safety factor.
5. The pipe and fittings must be homogeneous
throughoutand free of visible cracks, holes, voids,
foreign inclusions, or other defects that may affect
the wall integrity.
6. The pipe and fittings for horizontal directional drilling
must be a minimum DR of 9. Pipe and fittings used
In open cut nstallations must be a minimum of DR
11.
C. Joints
1. No person may join PE pipe unless Engineer has
approved that person.
2. The butt fusion process should be used to join
sections of PE pipe into continuous lengths at the job
site. The joining method must be by the heat fusion
method and must be performed in strict accordance
with the pipe manufacturer's recommendations. The
heat fusion equipment used in the joining procedures
must be capable of meeting all conditions
recommended by the pipe manufacturer.
3. Properly executed electrofusion fittings may be used.
4. Extrusion welding, hot gas welding or threading and
gluing of PE pipe will not be accepted.
5. MJ adapters are required to mechanically connect PE
pipe tomain line valves three (3) inches or larger.
Two (2) inch valves and smaller must be connected
by compression fittings.
6. Refer to the manufacturer's recommendations for
proper installation procedures.
7. Fused segments of pipe must be handled so as to
avoid damage to the pipe. Chains or cable type
chokers must be avoided when lifting fused sections
of pipe. Nylon slings are preferred. Spreader bars are
recommended when lifting long fused sections.
D. Precautions
1. During the heat fusion process the equipment and
pipe product may reach temperatures in excess of
four hundred (400) degrees Fahrenheit. Caution
should be taken to prevent burns.
2. Static electricity charges are generated on PE pipe by
friction, particularly during the handling of pipe in
storage, shipping and installation. The flow of air or
gas containing dust or scale will also build up
significant static charges, as will the flow of dry
materials through the pipe. These charges are a
safety hazard, particularly in areas where there is
leaking gas or a flammable /explosive atmosphere.
3. Coiled PE pipe may contain energy as in a spring.
Uncontrolled release by cutting straps, etc. can result
in dangerous uncontrolled forces. Exercise appropriate
safety precautions and use proper equipment.
4. PE pipe is impact resistant. Any hitting of the pipe
with an instrument, such as a hammer, may result in
uncontrolled rebound.
E. All final connections to Lift Station /Force Main Manholes
must not be completed until all PE materials have reached
equilibrium conditions (average ground temperature, etc.).
4. FITTINGS
Fittings shall be cast iron of ductile iron conforming to ANSI
Specification ABBE.10 -1971 (A C110 -71). Fittings shall be
designed and manufactured for a pressure rating of 250
psi. Fittings shall be tar coated and shall be cement lined
in accordance with ANSI Specification ABBE.4 1974 (A C104 -
74). Fittings joints shall be mechanical joints conforming to
ANSI Specification ABBE.11 -1972 (A C11 -72).
5. COPPER TUBING
Shall be seamless, annealed copper tubing complying with
Federal Specification WW -T -799. Fittings shall be wrought
copper or cast bronze with solder joints. Solder shall be of
a composition recommended by the manufacturer of the
fittings.
6. FIRE HYDRANTS
Shall comply with A Specification C -502 and shall meet local
standards and requirements, particularly as to nozzle
diameters and threads, direction of opening and dimensions
of operating and cap nuts. Fire hydrants shall have one
pumper and two hose nozzles. A valve opening not less than
5 inches and a 6 inch inlet connection. The length of the
hydrant barrel shall be determined by the specified depth of
cover over the pipe. All private water hydrants are to be
painted a color other than that utilized by the Water
Company. Hydrants shall be located such that the direction of
opening is directed towards the street.
7. VALVES
All valves and stops shall have ends suited or adapters shall be
provided for the proper installation in the lines in which they
are located. Valves shall meet local standards or in the
absence of such standards, the following requirements:
A. Valves in cast iron pipe shall be iron body, bronze
mounted, disc gate valves conforming to A Specification C-
500. They shall open in the some direction as those used
In the local waterworks system. Valve stems shall
terminate in 2 inch wrench nuts. Furnish two (2) keys.
B. Valves in copper pipe shall be standard brass body,
round -way, ground -key stops, with T heads. Furnish two
(2) keys.
8. VALVE BOXES
Shall meet local standards or in the absence of such, shall
comply with the following requirements:
A. For iron body valves, boxes shall be approved standard
buffalo -type cast iron, adjustable shaft boxes, having a
minimum shaft diameter of !� inches.
B. For Brass body valves (stops) boxes shall be approved
standard cast iron extension service boxes, having a
minimum diameter of 2 1/2 inches and having lid held in
place by a brass or bronze bolt. The castings shall be
coated with two coats of coal -tar pitch varnish. Furnish
two (2) keys for bolt in lids.
9. STOPS
Stops shall be those manufactured by Ford or Mueller
Corporation with A taper thread, and with copper compression
type fitting on outlet, or approved equal.
10. BLOW -OFF VALVES
Blow -off valves shall be those manufactured by Mueller
Corporation (H10283 of H- 10291) or approved equal.
11. ANGLE VALVES
Angle valves at the end of water service stub are to be
copper compression type fitting, and are to be protected with
plastic bag over the valve.
12. TAPS
1 inch taps in lines smaller than 4 inches shall be only by
tapped tee or tapped saddle. Water service lines should be
marked on curbs with blue paint (sewer lateral locations -
red). Taps onto existing main shall be performed in
accordance with rules of the Water Company having
jurisdiction.
13. DEPTH
The Water Mains shall be laid to a depth not less then five
feet (5' -0 ") below ground cover.
14. METER PITS
The Contractor shall furnish the meter pit(s) and vault of the
type as shown on the construction plans (meter to be
furnished by Water Company) along with all necessary quick -
disconnects, valves and appurtenances. This cost shall be
included in the bid amount for water lines. Meter pits must
be equipped with storm sewer drain or sump connected to
storm structure.
15. TESTS
Test the piping for leakage for a period of at least two hours
at a pressure of 150 pounds per square inch. Inspect all
joints for leakage and remedy any leaks. Upon completion of
the water distribution mains, flush out the system until the
water runs clears. As soon as the system has been flushed
out, it shall be sterilized in accordance with the requirements
of the local water department.