HomeMy WebLinkAboutD101-Demo PlanI I --ii DEMO FLOOR PLAN SCALE: 1 /8" = V -0" DEMO CEILING PLAN SCALE: 1/8" = V -0" SPECIFIC DEMOLITION NOTES ! i i OREMOVE EXISTING DOOR, FRAME, AND RELATED ITEMS. SALVAGE FOR RELOCATION OREMOVE EXISTING DUPLEX RECEPTACLE BACK TO SOURCE O3 REMOVE AND RELOCATE EXISTING THERMOSTAT AS REQUIRED, TYP. REMOVE COUNTER TOP AND BACKSPLASH I � -- - 5 REMOVE EXISTING WALL CONSTRUCTION AS INDICATED BY DASHED LINES 12 I I REPAIR REMAINING WALLS TYP. I 6 REWORK EXISTING SUSPENDED CEILING GRID AS REQUIRED FOR NEW O 2'X 4' LAY -IN TILES. SHOWN AS DASHED LINES REMOVE AND RELOCATE EXISTING LIGHT FIXTURE AS REQUIRED. / 13 �O 9 SHOWN AS DASHED LINES. SALVAGE FOR RELOCATION DEMO AND PREP FOR NEW WINDOW g0 PATCH REPAIR AND SALVAGE EXISTING CEILING GRID FIXTURES, DIFFUSERS AND RETURNS AS NEEDED. NOT USED I� ! 8 REMOVE AND RELOCATE EXISTING SHOWER \ \ I 1 t 2 12 12 DEMO AND PREP FOR NEW DOOR �, o EXISTING THERMOSTAT TO REMAIN II 5 - - - -- z II q I�!I' 1 5 LL 9 \ - '' - - -- 9 5 0 2 II 5 II I II 8 ! ! LL 2 1 II 5 �f II u II !� T "f —I — t- -t Lzo f -1 -r I I I I I I I All I I I I IF- - - - - -_ L 1 I I _ill -I a- a j.- III -F I LJ_ -i J_L1J u i I I I j',I I I I I rn 'I I I I I I III I I I I I I Ir I - r�rT_T�I I I 1 — 1 _1_ L 1 I I —1 I I I I I �I— I I —I— I I -1-F 1 —I— —_ _= 7 I��T -1—r I t- -t I t--1 =CIS_ � I ���I I I I I I I! 1 1 1 1 1 1 1 —I— I I- - 1 L 1 J— L J�' 1 III I h1 1 1 1 1 1 1I I I I I I IIJi I I I I! 1= 1- LZy— F - +� —F- 7 —T7 I I I I I I I =CIS_ 1 I IL1J_L _T- 1y�- rt —I —r� I— t'rt- 1— t-4 —I- 1 1 1 1 1 n 1 I I I I I I I I I I I I I I I II I� 1 1 1 I I I I I I 1 I n I -,'� -- — 1 1 I I I I I I— T -T —1-1 Fi— +- i I I I I III I �� I I I �I I I I I I In1 I I I I J -! -! - J4- r+``T�� -� 1- J- -4 - 1- �1- 1�`l -FT-1 �1� '� I- I-r -I- fi rt -1�' Iu I— ( I I I I I I I -.1-4 I - 1I T 1 -1— r I —I— �1— L1 -1 —II I_4 GENERAL DEMOLITION NOTES 1. PRIOR TO STARTING DEMOLITION, DUST CONTROL BARRIERS SHALL BE CONSTRUCTED TO PREVENT SPREAD OF DUST INTO SURROUNDING AREAS. 2. EXITING FROM STRUCTURE, IF REQUIRED TO PASS THROUGH DEMOLITION AREA, SHALL HAVE APPROVED BARRIERS, ETC. TO ENSURE SAFETY OF PUBLIC AND OFFICE EMPLOYEES. 3. SAVE ALL REMOVED LIGHTING FIXTURES, CEILING TILE & SUSPENSION SYSTEM FOR REUSE IN NEW OFFICE AREA. CONTRACTOR TO REUSE LIGHTING FIXTURES, CEILING TILE & SUSPENSION SYSTEM AS MUCH AS POSSIBLE. VERIFY ANY ITEMS WHICH ARE QUESTIONABLE WITH ARCHITECT. SEE MECHANICAL & ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 4. RELOCATED ITEMS SHALL CLEANED AND PLACED IN STORAGE UNTIL ITEMS ARE READY TO BE REINSTALLED. IF ITEM IS DAMAGED, IT SHALL BE REPAIRED OR REPLACE WITH NEW ITEM AS APPROVED. 5. DEMOLITION SHALL BE PERFORMED WITHOUT DAMAGE TO ADJACENT RETAINED WORK. WHERE SUCH DAMAGE OCCURS, PATCH, REPAIR OR OTHERWISE RESTORE TO ITS ORIGINAL CONDITION. 6. WHERE DEMOLITION WORK LEAVES HOLES AND DAMAGED SURFACES THAT WILL BE EXPOSED IN FINISHED WORK, THESE HOLES AND DAMAGED SURFACES SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT FINISH SURFACE. 7. PATCH AND /OR REPAIR CEILING GRID SYSTEM WHERE WALLS OR PARTITIONS HAVE BEEN REMOVED. 8, PATCH AND /OR REPAIR FLOOR IN PREPARATION FOR NEW FLOORING WHERE PARTITIONS HAVE BEEN REMOVED 9, REMOVE ELECTRICAL WIRING IN WALLS THAT ARE TO BE REMOVED. SEE ELECTRICAL PLAN FOR ADDITIONAL INFORMATION. 10. SOLID LINES INDICATE STRUCTURE AND /OR EQUIPMENT TO REMAIN. 11. DASHED LINES INDICATE STRUCTURE AND /OR EQUIPMENT TO BE REMOVED. 12. THE PREFIX "E" ON ROOM NUMBERS INDICATES EXISTING ROOM. 13. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONSTRUCTION MATERIALS. 14. THE MECHANICAL AND ELECTRICAL CONTRACTORS ARE TO FIELD VERIFY ALL EXISTING CONDITIONS TO COORDINATE POINTS OF TERMINATION, ANY RELOCATION OF EXISTING EQUIPMENT, RECONNECTION AND /OR REPLACEMENT OF COMPONENTS NEEDED TO MAINTAIN EXISTING AREAS NOT INCLUDED IN THE DEMOLITION SCOPE OF THE WORK. ALL ELECTRICAL DEMOLITION IS TO BE COMPLETED BACK TO MAIN SOURCE. 15. THE MECHANICAL AND ELECTRICAL CONTRACTORS ARE TO COORDINATE THE CUTTING AND CAPPING OF ALL EXISTING UTILITY SERVICE LINES. HOWEVER THE GENERAL DEMOLITION CONTRACTOR WILL BE RESPONSIBLE FOR THE REMOVAL OF ALL MECHANICAL AND ELECTRICAL EQUIPMENT THAT WILL NOT BE REQUIRED ONCE THE UTILITY SERVICES HAVE BEEN CUT AND CAPPED. 16. THE DEMOLITION CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE THE CUTTING AND CAPPING OF ALL EXISTING UTILITY SERVICE LINES WITH THE MECHANICAL AND ELECTRICAL CONTRACTORS IN UNISON WITH THE GENERAL DEMOLITION WORK. 17. CONTRACTOR TO REPORT ANY DISCREPANCIES WITH EXISTING CONDITIONS TO ARCHITECT FOR ADDITIONAL INFORMATION. DEMO PLAN LEGEND SYMBOL DESCRIPTION 2' -0" X 4' -0" SUSPENDED CEILING GRID & LAY -IN TROFFER CEILING GRID /LIGHT FIXTURE TO BE DEMOLISHED EXISTING WALL CONSTRUCTION TO BE REMOVED. EXISTING WALL CONSTRUCTION TO REMAIN DESIGNATES SPECIFIC ITEM TO BE REMOVED EXISTING DOOR TO REMAIN I10\ go , EXISTING DOOR TO REMOVED J DRWG START DATE: 04/08/08 W BW SHEET: D101 O x W �o �kD WLU� z wg x z �~ w O �WW X w� No 0 LLJ 0� J �U U W m a U W� aQ 3� .W Q J DRWG START DATE: 04/08/08 W BW SHEET: D101 O W �o �kD WLU� z wg z �~ w O �WW X w� No 0 LLJ 0� J �U W m a DRWG FILE NAME: DEMO PLAN DRWG START DATE: 04/08/08 DRAWN BY: BW SHEET: D101 FBi PROJECT #: ASPEN INDY