HomeMy WebLinkAboutT1.3 Life Safety Plan.pdfProject Number: Revisions: Drawn By Checked ByIssue Date Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: A F O R M A L A F F A I R Ca r m e l , In d i a n a 4 6 0 3 2 CA R M E L C I T Y C E N T E R - B L D G B 73 6 H a n o v e r P l a c e Su i t e 1 0 0 C COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: MC MC 1/28/13 State Release Set SUITE 100C Mo n d a y , J a n u a r y 2 8 , 2 0 1 3 ; a l l d a t a : M S : D E S I G N : P R O J E C T S : C A R M E L C I T Y C E N T E R : C C C D r a w i n g s : C C C C o n s t r u c t i o n D o c : B u i l d i n g A : A . G e n e r a l : B L D G A I N T E R I O R S : T E N A N T S : F O R M A L A F F A I R : D R A W I N G S : I B A S E - F o r m a l A f f a i r . p l n PEDCOR DESIGN GROUP llc T1.3 Life Safety Plan CONSTRUCTION DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2013 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA. XX/XX/10 E R 28 22 16 H 11 SCALE:
NTS PLAN
NORTH KEY
PLAN N A FORMAL AFFAIR LIFE SAFETY & CODE SUMMARY PROJECT SUMMARY This change of occupancy project is known as A Formal Affair and occupies 243 square feet of the ground floor of an existing Shell and Core project known as Carmel City Center. The A Formal Affair project occupies approximately three percent (3%) of the ground floor area of a three (3) story building. Beneath the ground floor and separated with a 3-hour fire resistive assembly, is an unheated parking garage. The A Formal Affair project is currently a Group B occupancy being changed to a Group M occupancy, and the construction type of this project and the shell and core is II-A. The entire facility is fully protected by an automatic sprinkler system, and is surrounded by at least 30 feet of yard depth. The A Formal Affair tenant is a formal wear rental showroom with display space and changing room space. APPLICABLE CODES & STANDARDS Indiana General Administrative Rules (675 IAC 12) 2006 Indiana
Building
Code
(IBC
2006)




2008 Accessibility‐Indiana
Building
Code
(ANSI
A117.1‐2003)
2008 Minimum
Design
Loads
for
Buildings
(ASCE
7‐2005)
2008 Indiana
Plumbing
Code
(UPC
1997)

1999 Indiana
Mechanical
Code
(IMC
2006)




2008 Indiana
Electrical
Code
(NFPA
70‐2008)
2009 Indiana
Fuel
Gas
Code
(IFGC
2006)




2008 Indiana
Fire
Code
(IFC
2006)

























































































2008 Indiana
Energy
Conservation
Code
(ASHRAE
90.1
2007) 2010 NFPA
10-2002
Portable
Fire
Extinguishers 2006 NFPA
13‐1999
Installation
of
Fire
Sprinkler
Systems




2002 NFPA
72‐2002
National
Fire
Alarm
Code 2006 NFPA
90A‐
Installation
of
Air
Conditioning
&
Ventilating

Systems
1999 NFPA
90B
—
Installation
of
Warm
Air
Heating
&
Air
Conditioning
Systems



1999 Americans
with
Disabilities
Act
(2010
Standards
for
Accessible
Design)
2010 OCCUPANCY CLASSIFICATIONS: A Formal Affair: Group M Building Shell & Core: Group A-2, A-3, B, M, R-2 Parking Garage: Group S-2 OCCUPANT LOAD A Formal Affair Total Gross Area 243 sq ft M Occupancy @ 15 sf/person 16 persons CONSTRUCTION TYPES: Building B Office Suites Tenant: Type II-A Building Shell & Core: Type II-A Parking Garage: Type I-A BUILDING AREAS: A Formal Affair Tenant: 243 sf Gross Floor Area - First Floor 9,349 sf Gross Floor Area - Second Floor 9,414 sf Gross Floor Area - Third Floor 9,414 sf Total Building Shell & Core 28,177 sf FIRE RESISTANCE A Formal Affair Tenant & Shell & Core (Ground Floor): Non Load Bearing Walls: All construction to be non-combustible Exit Passageways: 1 hour Exit Access Corridors: 0 hours Ceiling: 0 hours (Separating B and B) Floor: 3 hours (Separating B and S-2) INTERIOR FINISHES A Formal Affair Tenant & Shell & Core (Ground Floor): Vertical Exits & Passageways: Class B Exit Access Corridors Class C All Others Class C FIRE PROTECTION 100% protection by an automatic sprinkler system per NFPA 13-1999 100% protection by a fire alarm & enunciator system meeting NFPA 72-2002 Sprinkler fire pump and backup power meeting NFPA 20-1999 ACCESSIBILITY REQUIREMENTS All tenant restrooms comply with ICC/ANSI A117.1-2003; Section 604.5.1 PREVIOUS IDHS APPROVALS Project No. 317769 CDR Letter Foundation Release 04.25.06 Project No. 317796 CDR Letter Standard Release - Architectural & Structural 06.19.07 F SUITE 100C CL. 112 20 ' - 1 " 59'-4" 20 ' - 4 " 16'-4" R L M N N.1M.5 M.9L.1 L.5 L.9 22 21.9 21.5 21.4 20 19.9 21 SCALE: 1/4" = 1'-0" 1 LIFE SAFETY PLAN T1.3