ABBREVIATIONS LIST
AR ANCHOR RODS
ABV ABOVE
ACI AMERICAN CONCRETE INSTITUTE
ADD'L ADDITIONAL
ADH ADHESIVE
ADJ ADJACENT
AESS ARCHITECTURALLY EXPOSED
STRUCTURAL STEEL
AFF ABOVE FINISHED FLOOR
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
AISI AMERICAN IRON AND
STEEL INSTITUTE
ALUM ALUMINUM
ALT ALTERNATE
APA AMERICAN PLYWOOD ASSOCIATION
APPROX APPROXIMATE
ARCH ARCHITECT
ARCH'L ARCHITECTURAL
ASTM AMERICAN SOCIETY OF
TESTING MATERIALS
AWS AMERICAN WELDING SOCIETY
L ANGLE
BAL BALANCE
BB BOND BEAM
B/B BACK TO BACK
BC BOTTOM CHORD
BD BOARD
BLDG BUILDING
BLK BLOC(
BLW BELOW
BM BEAM
BOTT BOTTOM
BP BEARING PLATE
BRDG BRIDGING
BRG BEARING
BRK BRICK
BS BOTH SIDES
BSMT BASEMENT
BTWN BETWEEN
BUC BUILT UP COLUMN
c CAMBER
C/C CENTER TO CENTER
CANT CANTILEVER
CAIS CAISSON
CFS COLD FORMED STEEL
CJ CONTROL AND OR
CONSTRUCTION JOINT
CL CENTERLINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
COORD COORDINATE
COMP COMPACTED
CONC CONCRETE
CONN CONNECTION
CONTT CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CTR CENTER
CTR'D CENTERED
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DL DEAD LOAD
DLT DEEP LEG TRACK
DO DITTO
DN DOWN
DTL DETAIL
DWG DRAWING
DWL DOWEL
EA EACH
EE EA04 END
EF EACH FACE
EJ EXPANSION JOINT
ENG ENGINEER
ELEV ELEVATION
ELECT ELECTRICAL
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL
EQUIV EQUIVALENT
ES EACH SIDE
EW EACH WAY
EXIST -EX EXISTING
EXP EXPANSION
EXT EXTER I OXR
F/ FACE OF
FO FLOOR DRAIN
FDN FOUNDATION
FIN FINISH
FLR FLOOR
FLG FLANGE
FS FARSIDE
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GB GRADE BEAM
GC GENERAL CONTRACTOR
GL GLULAM
Gait GRADE
HC HOLLOW CORE
HD HOLD DOWN
HGT HEIGHT
HI HIGH
HK HOOK
HORIZ HORIZONTAL
HP HIGH POINT
HS HEADED STUD
HSS HOLLOW STRUCTURAL SECTION
ID INSIDE DIAMETER
IF INSIDE FACE
INFO INFORMATION
INT INTERIOR
INV INVERT
JST JOIST
JT JOINT
K KIP
KO KNOCK OUT
LB POUND
LDG LEDGE
LG LONG
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LNTL LINTEL
LSL LONG SLOTTED HOLES
LONG LONGITUDINAL
LP LOW POINT
LVL LAMINATED VENEER LUMBER
MAS MASONRY
MAT'L MATERIAL
MAX MAXIMUM
MBM METAL BUILDING MFR
MICJ MASONRY CONTROL JT
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOM MOMENT
MISW MASONRY SHEAR WALL
MSL MEAN SEA LEVEL
MTL METAL
MIN MASONRY WALL
NIC NOT IN CONTRACT
NO NUMBER
NS NEAR SIDE
NTS NOT TO SCALE
0/0 OUT TO OUT
OA OVERALL
OC ON CENTER
OD OUTSIDE D I METER
OF OUTSIDE FACE
OH OVER HEAD
OPNG OPENING
OPP OPPOSITE
OPP HD OPPOSITE HAND
OSB ORIENTED STRAND BOARD
OSL OUTSTANDING LEG
OVS OVERSIZE HOLE
PAF PONDER ACTUATED FASTENER
PC PRECAST
PL PLATE
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PNL PANEL
PROD PROJECTION
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLEL STRAND LUMBER
PT PRESSURE TREATED
PTN PARTITION
PVMT PAVEMENT
R RADIUS
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCE(D) (ING) (MENT)
REQ'D REQUIRED
REV REVISION/REVISED
RO ROUGH OPENING
RRD ROOF RELIEF DRAIN
RTN RETURN
RTU ROOF TOP UNIT
RW RETAINING WALL
SCHED SCHEDULE
SECT SECTION
SHT SHEET
SIM SIMILAR
Si SAWCUT JOINT
SJI STEEL JOIST INSTITUTE
SL SLOPED
SPA SPACE(S)
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
SSL SHORT SLOTTED HOLES
STD STANDARD
STIFF STIFFENERS
STL STEEL
STRUCT STRUCTURAL
SYM M SYMtrETR I CAL
TAB TOP AND BOTTOM
T&G TONGUE AND GROOVE
TB TIE BEAM
TC TOP CHORD
TEMP TEMPERATURE
TF TRENCH FOOTING
THK THICK
THKS THICKENED SLAB
THR'D THREADED
TL TOTAL LOAD
TOP'G TOPPING
TRANS TRANSVERSE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
W/ WITH
WD WOOD
WO WINDOW OPENING (MASONRY)
WP WORKING POINT
WT WEIGHT
WWF WELDED WIRE FABRIC
ELEVATION TOP AND
BOTTOM OF LIST
T/ ELEVATION, TOP OF
B/ ELEVATION, BOTTOM OF
T/BB TOP OF BOND BEAM
T/8M TOP OF BEAM
T /CONC TOP OF CONCRETE
T/F TOP OF FOOTING
T /LDG TOP OF LEDGE
T/MAS TOP OF MASONRY
T/P TOP OF PIER
T /SLAB TOP OF SLAB
T /STL TOP OF STEEL
T/W TOP OF WALL
T /GB TOP OF GRADE BEAM
T /CATS TOP OF CAISSON
B/PL BOTTOM OF PLATE
B/F BOTTOM OF FOOTING
SYMBOLS
0 DIAMETER
DEGREE
n VA110N
f PLUS OR MINUS
COLUMN FOOTING SCHEDULE
MARK
SIZE
REINFORCEMENT
F5.0
5' -0' x 5-00 x it
(5) #5 EW
F100
SEE PLAN
SEE DETAIL
COLUMIN FO01M SCHEDULE NOTES:
1. Provide 3' concrete cover on bors.
2. Use concrete brick or CRSI Class 3, CHCP wire bar supports at 3' -0•.
PIER SCHEDULE
MARK
SIZE
REINFORCEMENT
P20
20• x 20'
(4) #7 VERT
P32
32' x 32'
1 (8) #8 VERT
PIER SCHEDULE NOTES:
1. Provide 1V concrete cover over ties.
2. See typical pier elevation for tie and vertical bar placement.
3. Provide CRSI Typ Bar Bend No T5 ties for all veritcal face bars, if there are
more than four vertical bars In the pier.
COLUMN SCHEDULE
MARK
SIZE
BASEPLATE
(TXWXL)
ANCHOR RODS
W8x31
WBx31
-XV x 14' x 14'
(4) X4• A36
COLUMN SCHEDULE NOTES:
1. See typical detalls for column base construction.
MASONRY SHEAR WALL
SCHEDULE
MARK TYPE REINFORCEMENT
YERIICAL I BOND BEAY
MW8 18' CMU 1 #5 0 48' (2) #5 0 8' -0' MAX
OR QUICK
BRICK
MASONRY SHfJ1R WALL SCHEDULE NOTES:
1. (;rout all cares with rebor solid, unless noted otherwise.
2. Reinforcing steel in bond beams shall be continuous across control joints
unless noted otherwise.
BLOCK LINTEL SCHEDULE
FOR ALL LINTELS NOT INDICATED ON PLANS
ONTERIOR WALLS ONLY)
OPENING
CONCRETE LINTEL
Up to 6' -89
Precast Concrete (3000 psi, 145 pcf), (1)#5 Ti1B 80 Deep x
• x 7' Batt
e Wide, multiples to match wall thickness. Scored to match
L2
wall bond pattern.
6' -9' TO 10' -0'
Concrete Bond Beam Lintel Block, filled with concrete or
L3
gout (3000 psi), w/ (2) #5 TdB 8' Deep x Wall thickness.
TYPICAL BLOCK LNTEL SCHEDULE NOTES:
1. Precast lintels shill have 8• bearing on each end of opening.
2. Bond beam lintels shall extend 16• into wall on each side of opening.
3. Precast lintels shall be shored in center for 3 days. 3. Band beam lintels shall
be shored in center for 28 days.
STEEL LINTEL SCHEDULE
MARK
SIZE
PLATE
REMARKS
Li
WBx21
• x 7' Batt
Thermal Factor:
L2
L6x3hA
1
73630
L3
L6x*0j
(2) #5 TOP
(3) #5 BOTTOM
Analysis Procedure:
STEEL LNTEL SCHEDULE NOTES:
1. Provide 8' of bearing at each end, uno
2. Provide soap block on each side of lintels with bottom plates.
3. All exterior lintels shall be galvanized.
4. All interior lintels shall be shop primed with two coats of epoxy paint.
CONCRETE TRENCH FOOTING
SCHEDULE
MARK
SIZE (W x D)
REINFORCING
REMAKS
VERT TIES
HORIZ
1
Thermal Factor:
1
Basic Building System:
1
73630
36' x 30'
#4 0 48"
(2) #5 TOP
(3) #5 BOTTOM
Analysis Procedure:
Static
1. Provide 1JIF concrete cover over ties.
2. Provide Y concrete cover on bars.
BEARING PLATE SCHEDULE
MARK
SIZE (TxWxL)
REMARKS
BP1
y7 x4'x8•
Snow Importance Factor:
1
Thermal Factor:
1
BEARING PLATE SCHEDULE NOTES:
1. Hold bearing plate back )f from face of wall.
2. Provide (2) ) x60 headed anchors for masonry bearing, uno
3. Provide (2) Y4'x8' headed anchors for concrete bearing, uno
MASONRY AND REINFORCED MASONRY NOTES
M1. Minimum 28 day compressive strength of concrete masonry units shall be 2800 p.s.i. based on net area
of the unit. Specified design compressive strength of masonry shall be f'm = 2000 p.s.i. All units for
exterior walls, load- bearing walls and shear walls shall be normal weight block.
M2. All mortar shall be Type S. No admixtures may used unless approved by architect/engineer. Mortar shall
not be used for grouting cores or filling bond beams.
M3. All block shall be laid in a running bond pattern.
M4. Course grout shall be used were grouting is required. Slump shall be 8" +/- 1 ". Minimum grout
compressive strength shall be 3000 p.s.i.
M5. All reinforcing shall be ASTM A615 Grade 60 (Fy =60 ksi). Lap all reinforcing a minimum of 48 bar
diameters.
M6. See architectural and specifications for all control joint locations. Reinforcing in bond beams shall be
discontinuous at control joints.
M7. Provide ladder type horizontal joint reinforcement at 16" o.c. Side rods and cross rods shall be #9 wire,
galvanized, see specifications. Cut joint reinforcement at control joints.
M8. Provide "L" bars at all bond beam corners as required.
M9. Fill cores of block solid with grout two full courses below the bearing of all beams or lintels supported on
masonry.
M10. All attachments to block shall be made with Hilti HX 1/2" diameter x 3" sleeve anchors, unless noted
otherwise. Anchors shall be installed per manufacturer's recommendations,
M11. See typical schedules for masonry and steel lintels not indicated on plans.
M12. All masonry units below grade to be grouted solid.
M13. Provide ties to all structural steel.
M14. All interior, non -load bearing masonry walls over 12' -0" high, shall be supported on thickened slab as per
typical detail. Wall vertical reinforcing shall be #5 @ 48" OC full height. Unless noted otherwise.
M15. All cores with reinforcing steel shall be grouted solid, full height of wall.
STRUCTURAL STEEL NOTES
SS1. All structural steel shall conform to the following:
W Shapes ASTM A992, Gracie 50.
Angles, Channels, Plates, Bars ASTM A36 (Fy =36 ksi)
HSS Tubes ASTM A500, Gracie B (Fy =46 ksi)
HSS Pipes ASTM A500, Gracie B (Fy =42 ksi)
Anchor Rods ASTM F1554, Grade 36
SS2. All steel shall be detailed, fabricated and erected in accordance with AISC "LOAD & RESISTANCE
FACTOR DESIGN FOR STRUCTURAL STEEL BUILDINGS" and the "CODE OF STANDARD
PRACTICE ", Third Edition.
SS3. All bolted connections shall be made with 3/4" diameter, A325 bolts with nuts and washers, unless
otherwise noted. All connections shall be shear bearing connections tightened to snug -tight condition,
unless otherwise noted. All connections shall conform to the LRFD SPECIFICATION FOR STRUCTURAL
JOINTS USING ASTM A325 OR A490 BOLTS.
SS4. All shop and field welds shall be made using E70 electrodes or equivalent.
SS5. All headed concrete anchors shall be ASTM A108 (Fy =50 ksi), 3/4" diameter x 4" after welding, unless
noted otherwise.
SS6. Steel fabricator shall obtain the size and location of all openings for grilles, louvers, etc. before proceeding
with the fabrication and erection of any required frames.
SS7. Provide Heckman #129 and #130 channel slot and channel slot anchors at all columns that abut masonry
walls, unless noted.
SS8. Provide temporary bracing of the structure until all permanent lateral support is in place.
SS9. Structure Stability: The entire roof and/or floor decking materials must be fully erected and connected to
the supporting steel before temporary, erection bracing is removed.
SAWN LUMBER NOTES
W1. All wood shall be as follows:
2x4,2x6,2x8 - Spruce, Pine, Fir (SPF), #2, Kiln -Dried or Southern Pine, #2. All other sizes -
Southern Pine, #2, Kiln -Dried
W2. All wood, connections and erection shall be in conformance with the current edition of NFPA National
Design Specification.
W3. All connectors shall be Simpson Strong -Tie, galvanized, unless otherwise approved by McComas
Engineering.
W4. All bolts, washers and nuts shall be carbon steel, unless noted.
W5. All nails to be common type or building department approved equal.
W6. All sill plates shall be treated with preservative treatment.
W7. Attach all top plates and sill plates to studs with (2) 16d nails.
MANUFACTURED WOOD 1- JOISTS NOTES
WJ1. Manufactured Wood I- joists designated as TJI have been designed using product data from Trus Joist
MacMillan. Wood I- joists supplied by other manufacturer's shall meet or exceed the criteria for the
designated Trus Joist MacMillan product for the span, spacing, and loads indicated in the construction
documents.
WJ2. All connectors shall be manufactured be Simpson Strong -Tie Company, unless otherwise approved by
McComas Engineering.
WJ3. Contractor shall provide a complete installation of Manufactured Wood I joists, including b ut not limited to,
all blocking, stiffeners, and similar items.
WJ4. Manufactured Wood I- joists shall be designed by the supplier to meet the project requirements indicated
in the construction documents. Layout and design of Wood I- joists shall be signed and sealed by an
Engineer licensed to practice in the state of Indiana, and submitted to McComas Engineering, Inc. for
review.
WOOD SHEATHING NOTES
WS1. All plywood shall be 5/8" min. thickness APA rated 24/16, Exposure 1. Plywood shall conform to the latest
revision product standard PS 1.
WS2. Wall sheathing shall have long dimension perpendicular to supports. Roof sheathing shall have long
dimension perpendicular to supports, staggered joints. Provide 1/8" gap for all sheathing joints. Provide
panel clips for all roof sheathing.
WS3. Space all nails 3/8" minimum from panel or supporting member edge. Nails to penetrate supporting
members by 1 -5/8" minimum.
WS4. Edge of openings through roofs or walls shall be nailed per boundary nailing requirements indicated in
typical detail.
WS5. See architectural roof plan to establish all elevations, openings, equipment and other requirements not
indicated on structural drawings.
WS6. All nails to be common type or building department approved equal.
MANUFACTURED WOOD TRUSSES NOTES
WT1. Manufactured wood roof trusses or roof I- joists shall be designed for the following loads, in addition to
wind loading:
Bottom Chord Dead 10 psf
WT2. All connectors shall be manufactured be Simpson Strong -Tie Company, unless otherwise
approved by McComas Engineering. Use Simpson H1 Hurricane anchors on each end of trusses, for
double top plate. Simpson H3 Hurricane anchors on each end of trusses, for single top plate.
WT3. All bolts, washers and nuts shall be carbon steel.
WT4. All trusses connector plates shall be galvanized.
WT4. All trusses shall be spaced at 24" o.c., unless noted otherwise.
WT5. All standard, hip, valley, scissor, girder and other misc. trusses and supplemental roof framing not shown,
shall be designed and provided by the truss manufacturer and contractor. Truss manufacturer and
contractor shall be responsible for the final truss layout.
GENERAL NOTIES
G1. BUILDING CODES:
Model: International Building Code 2000
Local: Indiana Building Code 2003
Steel: American Institute of Steel Construction, LRFD 2nd Edition
Concrete: American Concrete Institute, 318 -99.
G2. DESIGN LOADS:
Roof
Dead Load: 15 psf
Live Load: 25 psf
Floor
Dead Load: 15 psf
Live Load: 100 psf
SNOW
Flat Roof Snow Load:
20 psf
Snow Exposure! Category:
P
Snow Exposure Factor:
1
Snow Importance Factor:
1
Thermal Factor:
1
►n l?FIC
Basic Wind Speed: 90 mph
Wind Importance Factor: 1
Building Classification: II
Wind Exposure Category: B
SEISMIC
Seismic Use Group:
1
Seismic Design Category:
A
Spectral Response, Sds:
0.086
Spectral Response, Sd1:
0.056
Site Class:
C
Basic Building System:
1
Basic Resisting System:
H
Design Base Shear:
0.0259 W
Analysis Procedure:
Static
G3. Reactions and forces indicated are Load and Resistance Factor Design (LRFD) loads.
G4. If Drawings ano specifications are in conflict, the most stringent restrictions and requirements shall
govern. Contractor shall bring all discrepancies to the attention of the engineer immediately.
G5. Verify all existing conditions prior to any construction or fabrication. If different than shown, notify
engineer /architect immediately for modification of drawings.
G6. All contractors are required to coordinate their work with all disciplines to avoid conflicts. The architectural,
mechanical, electrical and plumbing aspects are not in the scope of these drawings. Therefore, all
required materials and work may not be indicated. It is the contractor's responsibility to coordinate these
drawings with all other construction documents. Refer to architectural drawings for all dimensions not
shown on these drawings. Locations, sizes and numbers of all openings may not be completely indicated
in the structural drawings, the respective contractor shall verify their work with all other disciplines.
G7. The contract documents represent the structure only. They do not indicate the method of construction.
The contractor shall provide all measures necessary to protect the structure during construction. Such
measures shall include, but not limited to, bracing, shoring, underpinning, etc. McComas Engineering is
not responsible for the contractor's means, methods, techniques, sequences or safety procedures during
construction.
G8. Notes and details shall take precedence over general structural notes. Where no details or sections are
shown, construction shall conform to similar work on the project. Typical sections and details may not be
cut on the plans, but apply unless noted otherwise.
G9. Provisions for fixture expansion:
Vertical: None
Horizontal: None
REINFORCED CONCRETE NOTES (Foundations, Slabs & Walls)
RC1. All concrete shall have the following 28 day compressive strengths:
LOCATION STRENGTH AIR ENTRAIN.
Wall Footings, Spread Footings: 3000 psi 2%
All concrete below frost line, exterior
slabs, piers, walls, columns, grade beams,
concrete exposed to freeze /thaw: 4000 psi 6%
Interior slabs on grade,
fill for metal deck: 4000 psi Non AE
RC2. All reinforcing steel shall be detailed, supplied and placed in accordance with ACI 315 -99, ACI 318 -99
and CRSI MSP -1 -01.
RC3. All reinforcing steel shall be shop fabricated and, where applicable, shall be wired together and conform
to ASTM A -615, Grade 60.
RC4. Chamfer edges of exposed concrete 3/4 ", unless noted otherwise.
RC5. Contractor shall make four, 6"x12" test cylinders for each 50 cubic yards of concrete poured for each days
operation. Break 1 at 7 days, 2 at 28 days and retain spare.
RC6. All welded wire fabric shall conform to ASTM At 85, Fy(min) of 65 ksi. All welded wire fabric laps shall be
RC7. All finished concrete, concrete formwork and falsework shall be in accordance with ACI 301 -99.
Contractor is solely responsible for the design and construction of all formwork, falsework and shoring.
RC8. Provide the following coverages over reinforcing:
Footings:
Bottom and Unformed edges 3"
Formed ridges and top 2"
Slab on grade:
Welded wire fabric Upper Third
Reinforcing Steel 2"
RC9. Provide sleeves for all openings in grade beams or walls to totally separate pipe from concrete.
SHALLOW FOUNDATION AND SLAB ON GRADE NOTES
SF1. Design Soil Bearing Pressure:
Spread Footings 2000 psf
Wall Footings 2000 psf
(Based on Chapter 18 Table 1804.2 "Allowable Foundations and Lateral Pressure ").
SF2. Soil to be stripped, compacted and tested in accordance with the recommendations of the soils engineer
and project specifications.
SF3. Footings shall be placed on firm, undisturbed soil or on engineered fill. Engineered Fill: Naturally or
artificially graded mixture of natural or crushed gravel, crushed stone, and natural or crushed sand; ASTM
D 2940; with at least 90 percent passing a 1 -1/2 -inch sieve and not more than 12 percent passing a No.
200 sieve.
SF4. Slabs shall be placed on compacted, free - draining, frost -free drainage course. Drainage Course:
Narrowly graded mixture of washed crushed stone, or crushed or uncrushed gravel; ASTM D 448;
coarse- aggregette grading Size 57; with 100 percent passing a 1 -1/2 -inch sieve and 0 to 5 percent
passing a No. E; sieve. All fill shall be compacted to a minimum dry density of 95% of the modified Proctor
maximum dry density (ASTM- D1557), placed in 6" to 8" lifts. Pea gravel may not be used as fill. Utility
trenches and excavations under the foundations or slabs shall meet the same requirements. See soils
investigation report for further recommendations.
SF5. Undercutting of the soil for foundation and /or slab placement may be required. These drawings do not
indicate the entire scope of undercutting, fill or bad soil removal that may be required to attain the design
soil bearing pressures. It is the responsibility of the contractor to obtain a soils investigation report, before
bidding, to assess the extent of excavation and compaction that may be required to meet the design
criteria. The contractor shall retain the services of a soils engineer to monitor all backfilling operations and
to inspect footing bearing material. A report certified by the soils engineer shall be furnished to the
architect/engineer verifying that all foundations were placed on a material capable of sustaining the
design bearing pressures.
SF6. If dewatering is required, sumps shall not be placed within the foundation excavation.
SF7. Maintain a maximum slope between adjacent footing bearing elevations of 2 horizontal to 1 vertical.
Maintain a 2 horizontal to 1 vertical slope next to existing foundations to avoid undermining foundations.
SF8. No horizontal joints are permitted in any foundation. Vertical joints are permitted only in wall footings.
SF9. Sanallow foundations may be earth - formed where the excavation permits. If earth - forming is used, add 2"
to the width and length of all foundations.
SF10. The bottom of all foundations shall be a minimum of 36" below final grade.
i
CONSULTANTS
Ni
L
us
usSg
O
I1
�a
�o
Ce w w
Z w
FMWW
�vcoo w�wQ?°rF
ZLL, �Z< :D0
on
S _J 05zzza0 F M QUJ J<_JK
►� Z 0 W 0090000
F3 ao
Z�
n
M
(2)
CD
C
C
w
06
U)
2
Q
0
LLI
J
w J
N
U U
M
Q
O
'�I
o
X d0-
q =Q
W
CYZ
Q
�o
WT
co
UZ
U / w
Z
,� U w
O
Z
M�
C Q
U
_
Q
U_
T�
V
Q�.•�41STEQ
No.
860325
STATE OF
AMt
NAL
1
Oam erc
RCL, KLS
aMa.a �
MPP
CRM
fore
AS NOTED
awc
S401
°dY 10/06/06
A*d mow
MEI26125
i