Loading...
HomeMy WebLinkAbout06120009.21A55REV I AT 1 ONS ACT ACOUSTICAL GLG TILE EA. EACH ID IN51DE DIMEN51ON AD AREA DRAIN EL ELEVATION IN INCH ADA AMERICAN WITH 015ABILITIE5 ACT ELEC. ELECTRIC, INGL INCLUDING ADJ ADJUSTABLE ELEV ELEVATOR INFO INFORMATION AFF ABOVE FINISHED FLOOR EP EPDXY PAINT IN5UL INSULATION AL ALUMINUM EQ EQUAL ANOD ANODIZED EQUIP EQUIPMENT JT JOINT APPROX. APPROXIMATELY EAC ELECTRIC WATER COOLER LAM LAMINATE EXI5T EXISTING LIN LINEAR BD BOARD EJ EXPAN5ION JOINT L. LOWER LEVEL BTWN BETWEEN LP LOW POINT BLDG BUILDING FD FLOOR DRAIN BLK BLOCK, BLOCKING FDN FOUNDATION MAX MAXIMUM BM BENCHMARK FE FIRE EXTINGUISHER MG MINERAL GORE 55MT BASEMENT FEG FIRE EXTINGUISHER CABINET MEGH MECHANICAL BUR BUILT -UP ROOFING FF FIN15HED FLOOR MEJ MA50NRY EXPANSION JOINT FHG FIRE H05E CABINET MFR MANUFACTURER GAB CABINET FLR FLOOR MH MANHOLE OPT CARPET FTC FOOTING MIN MINIMUM GB CATCH BA51N FT FEET MISC. MISCELLANEOUS CJ CONTROL JOINT GA GAUGE, GAGE MO MA50NRY OPENING GL CENTER LINE GALV GALVANIZED MT MOUNTING GLG CEILING GB GYPSUM BOARD GMU CONCRETE MASONRY UNIT GL 6LAS5 NIG NOT IN CONTRACT CO GLEAN OUT GMU GLAZED MA50NRY UNIT NO NUMBER GOL COLUMN 65T GLAZED STRUCTURAL TILE NOM NOMINAL GONG. CONCRETE GP GYPSUM PLASTER GONT CONTINUOUS GR GRADE OG ON CENTER GP CEMENT PLASTER PR PAIR CT CERAMIC TILE HG HOLLOW GORE PL PLATE GU CUBIC HOW HARDWOOD PL,AM PLASTIC LAMINATE HM HOLLOW METAL PLYWD PLYWOOD DEMO DEMOLITION HORZ HORIZONTAL PT PAINT VIA DIAMETER HP HIGH POINT DIM DIMEN51ON HR HOUR QT QUARRY TILE OF DRINKING FOUNTAIN HT HEIGHT R RADIUS ON DOWN HTG HEATING REINF. REINFORCED, REINFORCING OR DRYER HVAG HEATING / VENTILATION / AIR REQ'D REQUIRED CONDITIONING 05 DOWN SPOUT RD ROOF DRAIN DWG DRAWING HAY HIGHWAY RM ROOM RO ROUGH OPENING 50 SOLID GORE 50HED SCHEDULE SEC SECTION 5HT SHEET 51M 51MILAR 5M SHEET METAL 5P STARTING POINT SPEC SPECIFICATIONS 50. SQUARE 55 5TAINLE55 STEEL 5TO STANDARD 5TL STEEL 5TRUC STRUCTURAL 5T4V STAIN d VARNI5H 505P SUSPENDED THK THICK TYP TYPICAL UNO UNLE55 NOTED OTHERWISE UL UNDERWRITER5 LABORATORY VGT VINYL COMPOSITION TILE VENT VENTILATION VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD VOL VOLUME VT VINYL TILE VAF VINYL WALL FABRIC WA WASHER W/ WITH AC WALL COVERING AD WOOD AH WATER HEATER NO WITHOUT WWF WELDED WIRE FABRIC INTERIOR WALL TYPES LEGEND : VARIES_ 4EZZANINE SEE SECTION LAY IN CEILING WHERE APPLICABLE VARIE5,4 SEE CEILING PLAN 5" GMU WITH HORIZONTAL JOINT REINFORCING ® lb" O.G. VERTICALLY FIN15H FLOOR [A] SAMFL.E YNAL-L_ A T`rFE TAG WALL TYPE CONSTRUCTION 5EE WALL TYPE LEGEND ABOVE mm V -II 1/4" AFFA '.ZANINE SEE 5ECTION Y IN CEILING ERE APPLICABLE 6" GMU WITH HORIZONTAL JOINT REINFORCING ® 16" O.G. VERTICALLY FINISH FLOOR UL ASSEMBL. I ES I. NOTE: SEE UNDERWRITERS LABORATORIES ING DIRECTORY 19x6 EDITION FOR APPROVED MANUFACTURES OF EACH COMPONENT. WALL T)"FE GENERAL NOTES: I. ALL WALL TYPES TO BE "A" UNLE55 NOTED OTHERWISE. 2. WHERE GYPSUM BOARD OR PLA5TER ABUTS MASONRY CONSTRUCTION, PROVIDE CONTINUOUS "J" -MOLD AND SEALANT AT JOINT. 3. PROVIDE CONTROL JOINTS IN MA50NRY AALL5 AS PER INDUSTRY PRACTICE AND/OR AS INDICATED. COORDINATE WITH ARCHITECT. 4. SEE WALL SECTIONS AND DETAILS FOR ALL EXTERIOR WALL ASSEMBLIES. 5. THE INTERIOR 51DE LAYER OF GYPSUM BOARD CAN BE ELIMINATED ON ALL RE5TROOM CHASE AND OTHER SHAFT WALL5, UNLE55 NOTED OTHERWISE, IF A FIRE RATING 15 NOT COMPROMISED. b. 5EE LIFE SAFETY PLANS FOR FIRE RATED WALL LOCATIONS. 1. WHERE WALL5 ARE USED AS A FIRE RATED WALL ASSEMBLY, VERIFY AVAILABLE FIRE RATINGS WITH MANUFACTURER. MATERIALS LEGEND 5%rM50LS LEGEND SECTION /DETAIL NOTATION POURED CONCRETE BATT INSULATION PRE CAST CONCRETE q RIGID INSULATION BLOCK EIFS BRICK GRAVEL/FILL EARTH GUT STONE GYPSUM BOARD — _ PLASTER ROUGH WOOD PARTICAL BOARD PLYWOOD FINISHED WOOD SECTION REFERENCE ON SHEET 5HEET WHERE 5ECTION 15 DRAWN ELEVATION SYMBOLS DETAIL REFERENGE ON 5HEET 5HEET WHERE ELEVATION 15 DRAWN �MCTURAL STEEL FLOOR ELEVATION SYMBOL (2i_oo TOP OF BEAM DOOR SYMBOL WINDOW SYMBOL 001 D < 10 ROOM NAME/NUMBER SYMBOL OFF I GE -- ROOM NAME 001 ROOM NUMBER 0:1 1999\ 990 4881101011cadWrchW001 _0990488_10101.dwg, 1016r2006 427:15 PM, cschaem 1:1 ARC,HITEGTURAL GENERAL NOTES: I. GENERAL NOTES TO PERTAIN TO ALL DRAWINGS. 2. ALL INTERIOR DIMEN51ON5 ARE TO FACE OF FINISHED WALL OR CENTERLINE OF COLUMN, UNLE55 OTHERA15E NOTED. 3. PROVIDE ALL WOOD BLOCKING AS REQUIRED FOR THE ATTACHMENT OF MISCELLANEOUS EQUIPMENT INCLUDING BUT NOT LIMITED TO, TOILET ACCESSORIES, DOOR HARDWARE, ELECTRICAL DEVICES, EQUIPMENT INDICATED, GRAB BAITS, HANDRAILS, AND CASEWORK. 16 GA. GALVANIZED SHEET METAL CAN BE USED AS BLOCKING. 4. TRANSITION OF DIFFERENT FLOORING MATERIALS AT DOORWAYS SHALL OCCUR AT CENTERLINE OF 5. ALL NEW DOOR FRAMES ARE TO BE 4" FROM ADJACENT FINISHED WALL 5URFACE AT DOOR HINGE U.N.O. DIMEN51ON FOR OPENINGS WITH DOOR5 ARE TO FACE OF DOOR JAMB. DIMENSION FOR OPENINC75 WITHOUT DOORS ARE TO FACIE OF WALL. 6. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD AS RECOMMENDED BY WAI.LBOAFU MANUFACTURER AND COORDINATE LOCATION WITH ARCHITECT. (APPROX. 30' O.C) 1. EXTERIOR WAL.L.5 WITH INTERIOR GYPSUM WALL- BOARD FINISH SHALL HAVE WALLBOARD, VAPOR- RETARDER AND INSULATION FULL HEIGHT. S. PAINT ALL WALL SURFACES, DOOR FRAMES, BULKHEADS 4 CEILINGS IN AREAS INDICATED ON ROOM FINISH SCHEDULE. PAINT BEHIND ALL MOVEABLE ITEMS ADJACENT TO SURFACES RECEIVING PAINT AND RELOCATE ITEMS. Q. ALL PRODUCTS UTILIZED IN THI5 CONSTRUCTION SHALL BE ASBESTOS FREE. 10. THE CONTRACTOR SHALL REFER TO THE 5PEGIFICATION5 FOR GLEANING AND DISPOSAL REQUIREMENTS. 11. THE CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH ALL ASPECTS OF THE WORK, EVEN TH05E AREAS DE5I6NATED TO BE PROVIDED BY OTHERS. THE FAMILIARIZATION INCLUDES FULL AND COMPLETE: UNDERSTANDING OF THE WORK DESCRIBED ON ALL 5HEET5 OF THE DRAWINGS AND ALL SECTIONS OF THE SPECIFICATIONS. FAILURE BY THE CONTRACTOR TO BECOME COMPLETELY FAMILIAR AND COGIqIZANT OF ALL ASPECTS OF THE WORK SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO PROVIDE MATERIALS, ASSEMBLIES, OR SERVICE INDICATED IN THE CONTRACT VOCUMENT. 12. NOTHING 5ET FORTH IN THESE DRAAING5 SHALL RELEASE THE CONTRACTOR FROM RESPONSIBILITY TO PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS, DIMEN51ONAL STABILITY, INSTALLATION, ANCHORAGE, AND COORDINATION WITH OTHER TRADES, OR WAIVE THE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY AND RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, OR WAIVE:: THE CONTRACTOR'S RESPONSIBILITY TD ALERT THE PROJECT MANAGER/ DESIGNER TO DISCREPANCIES CONTAINED THEREIN. 13. THE CONTRACTOR SHALL REVIEW IN ADVANCE ALL PORTIONS OF THE WORK TO VERIFY THAT THE WORK: WILL NOT PROHIBIT COMPLETION OF THE PROJECT AS INTENDED IN THESE CONTRACT DOCUMENTS. ANY QUE5TION5 HALL BE PROMPTLY REFERRED TO THE DESIGNER FOR RESOLUTION. 14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL SURFACES AND FIN15HE5 AT INTERIOR AND EXTERIOR OF BUILDING. DAMAGED 5URFACE5 AND FINISHES RESULTING FROM THE PERFORMANCE OF THE WORK SHALL BE REPAIRED AT NO COST TO THE OWNER BY THE CONTRACTOR TO MATCH EXISTING ADJACENT. 15. THE CONTRACTORS) SHALL BE RESPONSIBLE FOR COORDINATION WITH ALL TRADES. *rHE CONTRACTOR SHALL REFER TD ALL ASPECTS OF THE PRA 41NC75 AND 5PECIFIGATION5 INCLUDING BUT NOT LIMITED TO ARCHITECTURAL DRAW065, STRUCTURAL ORAWIN655, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS AS WELL AS RELATED SPECIFICATIONS FOR COORDINATION ISSUES. COORDINATE ALL DIAGRAMMATIC, ORAWIN65 WITH ALL TRADES TO ENSURE FIT AND COMPATIBILITY. A CONSULTANTS 00 N a rn pto 00:r w w 0 ai 0 w z — a. z � w 0 0 _ — a d zwz�►a- vi •(� �ZQSS1 J n - w ) cn x�000z N 1- O 05zzz<w N 4c 40 m <85551Y5 QC4 W 0*00000 o OD z n M v m m c rn c m a Z I— O Li Z V � N M O to Q LL �� � V q �z w W a wV � � Z 0? Q Lu �`'� M CK O Q � � U Q U W F_ U (� n V' G Kt r No. ,,. 1 900001; z k\ STATE OF 7 G ' Drm W. TAB MAG a m FJG sewc AS NOTED sheet A001 D4W 10/06/06 feed Nmtw PIC 0990488 -10102