HomeMy WebLinkAbout06120009.35L Q r N O CO co 0 O N O m 3 t- O O 0 d' O O OO �k F- U w O ce CL ABBREVIA TIONS_ ABBREVIA TIONS: ABBREV ABBREVIATIONS) HX HEAT EXCHANGER AC AIR COMPRESSOR HZ HER7Z (CYCLE PER SECOND) ACC AIR COOLED CONDENSER lE INVERT ELEVATION ACCU AIR COOLED CONDENSING UNIT IFB INTEGRAL FACE AND BYPASS ACD AIR COMPRESSOR DRYER IN INCH ACU AIR CURTAIN UNIT IN HG INCHES OF MERCURY (PRESSURE) AD ACCESS DOOR OR AREA DRAIN 1PLV INTEGRATED PART LOAD VALVE ADA AMERICANS WITH DISABIU77ES ACT IR INFRARED AFF ABOVE FINISHED FLOOR KEC KITCHEN EQUIPMENT CONTRACTOR AFG ABOVE FINISHED GRADE KEF KITCHEN EXHAUST FAN AFMS AIR FLOW MEASURING STATION KW KILOWATT AFUE ANNUAL FUEL UTILIZATION EFFICIENCY KOH KILOWATT HOUR AHU AIR HANDING UNIT L LONG OR LOUVER AMCA AIR MOVEMENT AND CONTROL ASSOCIATION /NTERNA77ONAL LA LEAVING AIR TEMPERATURE ANSI AMERICAN NATIONAL STANDARDS INS7I7UTE LBS POUNDS AP ACCESS PANEL LF LINEAL FEET APO AIR PRESSURE DROP (INCHES OF WC) LRA LOCKED ROTOR AMPS APPROX APPROXIMATELY LWT LEAVING WATER TEMPERATURE ARCH ARCH17ECT OR ARCH17EC7URAL MIA MIXED AIR ARI AIR - CONDITIONING AND REFRIGERATION INSTITUTE MAT MIXED AIR TEMPERATURE AS AIR SEPARATOR MUA MAKE -UP AIR UNIT ASHRAE AMERICAN SOCIETY OF HEA77NG, REFRIGERATING MAX MAXIMUM AND AIR - CONDITIONING ENGINEERS, INC. MBH THOUSAND BRITISH THERMAL UNIT PER HOUR ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS MC MECHANICAL CONTRACTOR ASTM AMERICAN SOCIETY FOR 7ES77NG AND MATERIALS MCA MINIMUM CIRCUIT AMPS AWT AVERAGE WATER TEMPERATURE MECH MECHANICAL B BOILER MFR MANUFAC7URER BCU BLOWER COIL UNIT MFS MAXIMUM FUSE SIZE BDD BACKDRAFT DAMPER MIN MINIMUM BFG BELOW FINISHED GRADE MOCP MAXIMUM OVERCURRENT PR07EC77ON BFP BACKFLOW PRESENTER MD MOTORIZED DAMPER BFS BOILER FEEDWATER SYSTEM MZU MUL77ZONE UNIT bHP BRAKE HORSEPOWER N NORTH BOD BOTTOM OF DUCT NA NOT APPLICABLE BOP BOTTOM OF PIPE NC NORMALLY CLOSED OR NOISE CRITERIA BOS BOTTOM OF S7EEL /S7RUC7VRE NEC NA71ONAL ELECTRICAL CODE BTUH BRI77SH THERMAL UNIT PER HOUR NFPA NATIONAL FIRE PR07EC77ON ASSOCIATION C COMMON (PORT TAG ON VALVE) NO NORMALLY OPEN OR NUMBER C DEGREES CELSIUS NOM NOMINAL CAF COMBUSTION AIR FAN NPT NOMINAL PIPE THREAD CAP CAPACITY NS NON SLAM CA CONSTANT AIR VOLUME NIS NOT TO SCALE CC COOLING COIL 01A OUTDOOR AIR CFH CUBIC FEET PER HOUR OAT OUTDOOR AIR TEMPERATURE CFM CUBIC FEET PER MINUTE ORD OPPOSED BLADE DAMPER CH CHILLER P PUMP CKT CIRCUIT P &T PRESSURE AND TEMPERA7URE CO CLEAN OUT OR CARBON MONOXIDE PBD PARALLEL BLADE DAMPER CO2 CARBON DIOXIDE PC PLUMBING CONTRACTOR CONT CONTINUATION OR CON77NUED PD PRESSURE DROP OR PRESSURE DIFFERENCE COP COEFFICIENT OF PERFORMANCE PDU POOL DEHUMIDIFICATION UNIT CP CONDENSER WATER PUMP PH PHASE CRAC COMPUTER ROOM AIR CONDITIONING UNIT PHC PREHEAT COIL CT COOLING TOWER PRESS PRESSURE C77 COOLING TECHNOLOGY INSTITUTE PRV PRESSURE REDUCING VALVE (HYDRONIC) CUH CABINET UNIT HEATER PSV PRESSURE SUSTAINING VALVE (HYDRONIC) CV CONVECTOR PSF POUNDS PER SQUARE FOOT CW CHILLED WATER PSI POUNDS PER SQUARE INCH CWP CHILLED WATER PUMP PSIA POUNDS PER SQUARE INCH ABSOLUTE D DEEP OR DEHUMIDIFIER PSIG POUNDS PER SQUARE INCH GAUGE DA DEA ERA TOR PTAC PACKAGED TERMINAL AIR CONDITIONER DACU DUCTLESS AIR CONDITIONING UNIT PVC POLYVINYL CHLORIDE DB DRY BULB QTY QUANTITY DO DUCT SMOKE DETECTOR R THERMAL RESISTANCE DDC DIRECT DIGITAL CONTROL R/A RETURN AIR DD78 DUAL DUCT TERMINAL BOX RCP RADIANT CEILING PANEL DEG C DEGREES CELSIUS RD ROOF DRAIN DEG F DEGREES FAHRENHEIT REFR/G REFRIGERANT DEMO DEMOLITION OR DEMOLISH RF /A RELIEF AIR DG DOOR GRILLE RF RETURN FAN DIA DIAMETER RH RELA77VE HUMIDITY DN DOWN RHC REHEAT COIL DOE U.S DEPARTMENT OF ENERGY RLA RUNNING LOAD AMPS DPT DIFFERENTIAL PRESSURE TRANSMITTER RPM REVOLUTIONS PER MINUTE D7F DOWN THROUGH FLOOR R7U ROOFTOP UNIT DTR DOWN THROUGH ROOF RV RELIEF VALVE (HYDRONIC) DWG DRAWING S SOUTH DX DIRECT EXPANSION S/A SUPPLY AIR E EAST SA SOUND ATTENUATOR E/A EXHAUST AIR SCP STEAM CONDENSATE PUMP EA EACH SCR STEAM CONDENSATE RECEIVER EAT ENTERING AIR TEMPERATURE SD SMOKE DAMPER EBB ELECTRIC BASEBOARD SEER SEASONAL ENERGY EFFICIENCY RA 710 EC ELECTRICAL CONTRACTOR OR COMBUSTION EFFICIENCY SEF SMOKE EXHAUST FAN ECH ELECTRIC CABINET HEATER OR ELECTRIC CEILING HEATER SENS SENSIBLE EDB ENTERING DRY BULB SF SQUARE FEET OR SUPPLY FAN EDH ELECTRIC DUCT HEATER SHGC SOLAR HEAT GAIN COEFFICIENT EER ENERGY EFFICIENCY RATIO SHT SHEET EF EXHAUST FAN OR ENERGY FACTOR SL STANDBY LOSS EFB EXTERNAL FACE AND BYPASS SM SECONDARY METER ELEV ELEVATION SMACNA SHEET METAL AND AIR CONDITIONING ENT ENTERING CONTRACTORS NATIONAL ASSOCIATION EOM END OF MAIN SMC SHEETMETAL CONTRACTOR ERU ENERGY RECOVERY UNIT SP STA77C PRESSURE ER ENERGY RECOVERY VENTILATOR SPEC(S) SPECIF7CATION(S) ESP EXTERNAL STATIC PRESSURE SPRS STEAM PRESSURE REDUCING STATION ET EXPANSION TANK OR THERMAL EFFICIENCY SPRV STEAM PRESSURE REDUCING VALVE EVH ELECTRIC UNIT HEATER SQ SQUARE EWB ENTERING WET BULB SRV SAFETY RELIEF VALVE (STEAM) EWH ELECTRIC WALL HEATER SS STAINLESS STEEL EWT ENTERING WATER 7EMPERA7URE SST SATURATED SUCTION TEMPERATURE F DEGREES FAHRENHEIT ST STORAGE TANK F FILTER OR FURNACE STAT THERMOSTAT FC FLUID COOLER T &P TEMPERATURE AND PRESSURE FCU FAN COIL UNIT T/A TRANSFER AIR FD FIRE DAMPER OR FLOOR DRAIN 7B TERMINAL BOX FSD COMBINATION FIRE AND SMOKE DAMPER TC TEMPERATURE CONTROL FFE FINISHED FLOOR ELEVATION TCC TEMPERATURE CONTROL CONTRACTOR FLA FULL LOAD AMPS TCP TEMPERATURE CON7ROL PANEL FLR FLOOR TEMP TEMPERATURE FM FACTORY MUTUAL TOD TOP OF DUCT FPC FIRE PROTECTION CONTRACTOR TOP TOP OF PIPE FPM FEET PER MINUTE TOS TOP OF S7EEL / SIRUC7URE FP78 FAN POWERED TERMINAL BOX TSP TOTAL STATIC PRESSURE FT FEET OR FLASH TANK TSU 774ERMAL STORAGE UNIT FIR FINNED TUBE RADIATION TYP TYPICAL GAL GALLON U THERMAL CONDUCTANCE GC GENERAL CONTRACTOR UH UNIT HEATER GEF GENERAL EXHAUST FAN UL UNDERAR17ERS LABORATORIES GPD GALLONS PER DAY UNO UNLESS N07ED OTHERWISE GPH GALLONS PER HOUR UTF UP THROUGH FLOOR GPM GALLONS PER MINUTE UTR UP THROUGH ROOF GV GRAVITY VENTILATOR UV UNIT VENTILATOR H HIGH OR HUMIDIFIER V VENT OR VOLTS HBS HEATING BOILER STANDARD VA VARIABLE AIR VOLUME HC HEATING COIL VB VACUUM BREAKER HO HOOD VD VOLUME DAMPER HEPA HIGH EFFICIENCY PARTICULATE AIR VFD VARIABLE FREQUENCY DRIVE HOA HAND-OFF-AUTOMA77C VTR VENT 771RU ROOF HP HORSEPOWER OR HEAT PUMP W WATT OR WEST OR WIDE HR HOUR WB WET BULB HSPF HEATING SEASON PERFORMANCE FACTOR WC WATER COLUMN (PRESSURE) HVU HEA77NG AND VENTILATING UNIT WPD WATER PRESSURE DROP (FEET OF WC) HW HEATING WATER WSA WIRE SIZE AMPS HAP HEATING WATER PUMP 0 DIAMETER OR PHASE POUND OR NUMBER a FLAT OVAL DUCT ? CENTERLINE SHEETMETAL SYMBOLS. NOTE. DIMENSIONS SHOWN ARE INSIDE CLEAR DIMENSIONS IF DUCT IS UNED, INCREASE DUCT SIZE TO ACCOMMODATE UNINGG, __+ GLOBE VALVE RECTANGULAR DUCT, DIMENSION IN INCHES BUTTERFLY VALVE CHI (SIDE SHOWN 1S FIRST DIMENSION) 12'0 ROUND DUCT, DIMENSION IN INCHES 12x6@ FLAT OVAL DUCT, DIMENSION IN INCHES f-- IN --fABV (SIDE SHOWN IS FIRST DIMENSION) Ell MANUAL VOLUME DAMPER r -r�r�' 4GV GAS VALVE RECTANGULAR S /A, 01A DUCT TURNED PRESSURE REDUCING VALVE CONSULTANTS WITH ACCESS DOOR f ---f UP PENETRATING STRUCTURE ABOVE h GRA NTY BACKDRAFT DAMPER W7771 ACCESS DOOR BDD DFIRE DAMPER W1771 ACCESS DOOR RECTANGULAR S /A, 01A DUCT DOWN SMOKE DAMPER WI7H ACCESS DOOR f -- -D� D VACUUM BREAKER VALVE f -�--�f THROUGH FLOOR OR DROP TO EQUIPMENT f- -D--d� CONCEN iRIC REDUCER OR INCREASER I-- 4 RECTANGULAR S /A, 01A DUCT f- -D75 --4 DTS DUAL TEMPERATURE SUPPLY DROP IN DIRECTION OF FLOW f - - - HPR- -f HPR HIGH PRESSURE CONDENSATE RE7URN f RECTANGULAR S /A, 01A DUCT f HPs --4 HPS HIGH PRESSURE STEAM (ABOVE 60 PSIG) Q RISE IN DIRECTION OF FLOW f--11 HPS-4 HPS HIGH PRESSURE ' TEAM (UNDERGROUND) � }-� -f PIPE CAP ON DE:MOU770N PLAN RECTANGULAR R /A, E /A, T /A, RF /A DUCT HEAT PUMP CONDENSER RETURN f- I ►---f PIPE DEMOLISH TO POINT ON DEMOL177ON PLAN f - -HS —f HS 7URNED UP PENE7RA77NG STRUCTURE ABOVE f -,,- -f PIPE CONNECT 1'0 EXISTING OV NEW PLAN f- -H*R -4 HWR HEA7NG WATER RETURN RECTANGULAR R /A, E /A, T /A, RF /A DUCT DOWN T 1 V 1 THROUGH FLOOR OR DROP TO EQUIPMENT f - - - LPR— - f LPR LOW PRESSURE CONDENSATE RETURN -� RECTANGULAR R /A, E /A, T /A, RF /A f - -LPS-4 LPS LOW PRESSURE STEAM (1 TO 15 PSIG) 0:�W DUCT DROP IN DIRECTION OF FLOW f -- -MPR --4 MPR MEDIUM PRESSURE CONDENSATE RETURN , v_ � J-' `�J RECTANGULAR R /A, E /A, T /A, RF /A f MPS --f MPS MEDIUM PRESSURE STEAM (16 TO 60 PS(G) DUCT RISE IN DIRECTION OF FLOW ROUND S /A, 01A DUCT TURNED UP PENETRATING STRUCTURE ABOVE f - -MU -4 MU MAKE -UP WATER ROUND S /A, 01A DUCT DOWN THROUGH f —PD --f PO FLOOR OR DROP TO EQUIPMENT �f� V D�G%STZ, ROUND S /A, 01A DUCT DROP f— / /PD-4 PD PUMP DISCHARGE (CONDENSATE) (UNDERGROUND) �►t�. AUTOMA77C AIR VENT RHG REFRIGERANT HOT GAS IN DIRECTION OF FLOW MANUAL AIR VENT f- -RL --f RL REFRIGERANT LIQUID ROUND S /A, 01A DUCT RISE sheet M001 f -- -RSA RS REFRIGERANT SUCTION IN DIRECTION OF FLOW PRESSURE GAUGE WITH VALVE" f — ws --4 SMS ROUND R /A, E /A, T /A, RF /A DUCT TURNED STEAM PRESSURE GAUGE Wl7H VALVE AND PIGTAIL UP PENETRATING STRUCTURE ABOVE SNOW MELT RETURN (GLYCOL) ROUND R /A, E /A, T /A, RF /A DUCT DOWN f - -sv -4 SV SAFETY RELIEF VENT LINE THROUGH FLOOR OR DROP TO EQUIPMENT THERMOMETER f- —v -_4 V VENT LINE ROUND R /A, E /A, T /A, RF /A DUCT PRESSURE/TEMFERA7URE PLUG SITE f— - Dcw-4 DCW DOMESTIC COLD RAW WATER DROP IN DIRECTION OF FLOW PRESSURE TAP !PORTABLE GAUGE) f— - scw -4 SCW DOMESTIC SOFT COLD WATER ROUND R /A, E /A, T A, RF /A DUCT -r RISE IN DIRECTION OF FLOW 7NERM0 WELL (PORTABLE GAUGE) G - G---f G NATURAL GAS FLAT OVAL S /A, 01A DUCT TURNED UP Q_j,�► COMPRESSED AIR PENETRARNG S7RUC7URE ABOVE IN LINE PUMP f— FOS —•f FOS FLAT OVAL S /A, 01A DUCT DOWN THROUGH Q��Q1 FLOW METER FLOOR OR DROP TO EQUIPMENT FUEL OIL RETURN rrs� f--f FLOW SWITCH FLAT OVAL S /A, 01A DUCT FUEL OIL VENT DROP IN DIRECTION OF FLOW FLOOR DRAIN f f PRESSURE SENSOR FLAT OVAL S /A, 01A DUCT AREA DRAIN f r PRESSURE SW1T(:H RISE IN DIRECTION OF FLOW FLOOR SINK FLAT OVAL R /A, E /A, T /A, RF /A DUCT © RD ROOF DRAIN TURNED UP PENETRATING STRUCTURE ABOVE FLAT OVAL R /A, E /A, T /A, RF /A DUCT DOWN THROUGH FLOOR OR DROP TO EQUIPMENT SI-a- J� TEMPERATURE SENSOR FLAT OVAL R /A, E /A, T /A, RF /A CLEANOUT J 4 TEMPERA SWITCH DUCT DROP IN DIRECTION OF FLOW STRAINER FLAT OVAL R /A, E /A, T /A, RF /A STRAINER WITH BLOW DOWN VALVE DUCT RISE IN DIRECTION OF FLOW DUCT RISE IN DIRECTION OF FLOW F-+-� DUCT DROP IN DIRECTION OF FLOW SHEETMETAL SYMBOLS• Liu 90' DUCT ELBOW WITHOUT TURNING VANES (RECTANGULAR LOW PRESSURE TRANSFER AIR DUCT ONLY) 90' DUCT ELBOW WITH 7URNING VANES ', (RECTANGULAR LOW PRESSURE DUCT ONLY) RADIUS DUCT ELBOW ( CEN7ERLINE RADIUS 1.5 x W) (ALL DUCT TYPES AND PRESSURE CLASSES) 45' FITTING FOR RECTANGULAR TO RECTANGULAR DUCT (ALL PRESSURE CLASSES - NO EXTRACTOR) CONICAL FI77ING FOR ROUND OR FLAT OVAL DUCT TO RECTANGULAR DUCT (ALL PRESSURE CLASSES) CONICAL FITTING FOR ROUND OR FLAT OVAL TO ROUND OR FLAT OVAL DUCT (ALL PRESSURE CLASSES) SPIN -IN FITTING FOR ROUND TO RECTANGULAR DUCT (LOW PRESSURE DUCT ONLY) ECCENTRIC DUCT 7RANS177ON (ALL DUCT TYPES AND PRESSURE CLASSES) CONCENTRIC DUCT 7RANSI7ION (ALL DUCT TYPES AND PRESSURE CLASSES) EDORECTANGULAR TO ROUND OR FLAT OVAL DUCT TRANSITION (ALL PRESSURE CLASSES) COMBINATION FIRE AND SMOKE DAMPER WITH ACCESS DOOR FSD DUCT SMOKE DETECTOR W1774 ACCESS DOOR DO AIR FLOW MEASURING STATION WI7H UAFUSI ACCESS DOOR DUCT MOU TED HYDRONIC REHEAT COIL WITH ACCESS DOOR DUCT MOUTED ELECTRIC DUCT HEATER WITH ACCESS DOOR 1 1 (DASHED LINES INDICATE 42" CLEARANCE) I 1 TERMINAL BOX 1 1 (DASHED LINES INDICATE 24' CLEARANCE) TERMINAL BOX WITH ELECTRIC REHEAT (DASHED LINES INDICATE 42' CLEARANCE) I 1 1 1 I I J mFLEXIBLE DUCT CONNECTION roffl SOUND ATTENUATOR �D ACCESS DOOR MOUNTED IN MOST ACCESSIBLE SIDE OF DUCT �® FLEXIBLE DUCT TO SQUARE S/A DIFFUSER =0-0 FLEXIBLE DUCT TO ROUND S/A DIFFUSER ® 2 -WAY OPPOSITE THROW S/A DIFFUSER 19 2 -WAY CORNER THROW S/A DIFFUSER ® 3 -WAY THROW S/A DIFFUSER ROUND S/A DIFFUSER ® 4 -WAY THROW SQUARE S/A DIFFUSER R /A, E /A, T /A, RF /A GRILLE/REGISTER FLEXIBLE DUCT TO PLENUM OF SLOT DIFFUSER OR LINEAR BAR GRILLE SIDEWALL MOUNTED R /A, E /A, T /A, RF /A GRILLE/REGISTER "A^-► SIDEWALL MOUNTED S/A GRILLE/REGISTER EQUIPMEN T DESIGNATIONS. . AHU-12 EQUIPMENT MARK NUMBER (REFER TO SCHEDULES) EQUIPMENT NUMBER EQUIPMENT ABBREVIATION AlO -350 DIFFUSER /GRILLE/REGISTER DESIGNATION (REFER TO SCHEDULES) CFM MARK LETTER AWu 12 0 MONITOR /CONTROL EQUIPMENT EQUIPMENT THAT IS BEING M O N I T O RED /C O N T R 0 L L ED PIPING SYMBOLS AND ABBREVIA TIONS• PIPING SYMBOLS AND ABBRE A TIONS• P-& -f GV GATE VALVE IN ROAD BOX DUCT CAP ON DEMOLITION PLAN GATE VALVE __+ GLOBE VALVE f- 1F{--f BFV BUTTERFLY VALVE DUCT DEMOLISH TO POINT ON DEMOLITION PLAN BALL VALVE f—N—f NON SLAM CHECK VALVE (FLOW TO RIGHT) f --tV -f DUCT CAP f-- IN --fABV DUCT CONNECT TO EXISTING ON NEW PLAN Ell MANUAL VOLUME DAMPER r -r�r�' 4GV GAS VALVE MOTORIZED DAMPER PRESSURE REDUCING VALVE CONSULTANTS WITH ACCESS DOOR f ---f STA77C PRESSURE SENSOR WI771 ACCESS DOOR h GRA NTY BACKDRAFT DAMPER W7771 ACCESS DOOR BDD DFIRE DAMPER W1771 ACCESS DOOR FD SO SMOKE DAMPER WI7H ACCESS DOOR Liu 90' DUCT ELBOW WITHOUT TURNING VANES (RECTANGULAR LOW PRESSURE TRANSFER AIR DUCT ONLY) 90' DUCT ELBOW WITH 7URNING VANES ', (RECTANGULAR LOW PRESSURE DUCT ONLY) RADIUS DUCT ELBOW ( CEN7ERLINE RADIUS 1.5 x W) (ALL DUCT TYPES AND PRESSURE CLASSES) 45' FITTING FOR RECTANGULAR TO RECTANGULAR DUCT (ALL PRESSURE CLASSES - NO EXTRACTOR) CONICAL FI77ING FOR ROUND OR FLAT OVAL DUCT TO RECTANGULAR DUCT (ALL PRESSURE CLASSES) CONICAL FITTING FOR ROUND OR FLAT OVAL TO ROUND OR FLAT OVAL DUCT (ALL PRESSURE CLASSES) SPIN -IN FITTING FOR ROUND TO RECTANGULAR DUCT (LOW PRESSURE DUCT ONLY) ECCENTRIC DUCT 7RANS177ON (ALL DUCT TYPES AND PRESSURE CLASSES) CONCENTRIC DUCT 7RANSI7ION (ALL DUCT TYPES AND PRESSURE CLASSES) EDORECTANGULAR TO ROUND OR FLAT OVAL DUCT TRANSITION (ALL PRESSURE CLASSES) COMBINATION FIRE AND SMOKE DAMPER WITH ACCESS DOOR FSD DUCT SMOKE DETECTOR W1774 ACCESS DOOR DO AIR FLOW MEASURING STATION WI7H UAFUSI ACCESS DOOR DUCT MOU TED HYDRONIC REHEAT COIL WITH ACCESS DOOR DUCT MOUTED ELECTRIC DUCT HEATER WITH ACCESS DOOR 1 1 (DASHED LINES INDICATE 42" CLEARANCE) I 1 TERMINAL BOX 1 1 (DASHED LINES INDICATE 24' CLEARANCE) TERMINAL BOX WITH ELECTRIC REHEAT (DASHED LINES INDICATE 42' CLEARANCE) I 1 1 1 I I J mFLEXIBLE DUCT CONNECTION roffl SOUND ATTENUATOR �D ACCESS DOOR MOUNTED IN MOST ACCESSIBLE SIDE OF DUCT �® FLEXIBLE DUCT TO SQUARE S/A DIFFUSER =0-0 FLEXIBLE DUCT TO ROUND S/A DIFFUSER ® 2 -WAY OPPOSITE THROW S/A DIFFUSER 19 2 -WAY CORNER THROW S/A DIFFUSER ® 3 -WAY THROW S/A DIFFUSER ROUND S/A DIFFUSER ® 4 -WAY THROW SQUARE S/A DIFFUSER R /A, E /A, T /A, RF /A GRILLE/REGISTER FLEXIBLE DUCT TO PLENUM OF SLOT DIFFUSER OR LINEAR BAR GRILLE SIDEWALL MOUNTED R /A, E /A, T /A, RF /A GRILLE/REGISTER "A^-► SIDEWALL MOUNTED S/A GRILLE/REGISTER EQUIPMEN T DESIGNATIONS. . AHU-12 EQUIPMENT MARK NUMBER (REFER TO SCHEDULES) EQUIPMENT NUMBER EQUIPMENT ABBREVIATION AlO -350 DIFFUSER /GRILLE/REGISTER DESIGNATION (REFER TO SCHEDULES) CFM MARK LETTER AWu 12 0 MONITOR /CONTROL EQUIPMENT EQUIPMENT THAT IS BEING M O N I T O RED /C O N T R 0 L L ED PIPING SYMBOLS AND ABBREVIA TIONS• PIPING SYMBOLS AND ABBRE A TIONS• P-& -f GV GATE VALVE IN ROAD BOX f -D4- -f GV GATE VALVE f- 00 -468V GLOBE VALVE f- 1F{--f BFV BUTTERFLY VALVE BV � BALL VALVE f—N—f NON SLAM CHECK VALVE (FLOW TO RIGHT) f --tV -f SWNG CHECK VALVE (FLOW )O RIGHT) f-- IN --fABV AUTOMA77C BALANCING VALVE" f­Ol MBV MANUAL BALANCING VALVE r -r�r�' 4GV GAS VALVE f__A_4PRV PRESSURE REDUCING VALVE CONSULTANTS SOLENOID V4LW7_ f ---f TWO -WAY TEMPERATURE CONTROL VALVE h THREE -WAY TEMPERATURE CONTROL VAL VE (MIXING) "+ RELIEF VALVE f -- -D� D VACUUM BREAKER VALVE f -�--�f ECCENTRIC REDUCER OR INCREASER f- -D--d� CONCEN iRIC REDUCER OR INCREASER t- -XVw 4 BFW BOILER FEED WATER PIPE UP THROUGH FLOOR f - -cR —f CR CONDENSER RETURN A PIPE DOWN THROUGH FLOOR OR DROP/RISE Cs —f CS CONDENSER SUPPLY �-0 TO EQUIPMENT - -cwr -f CWR CHILLED WATER RETURN PIPE RISE IN DIRECTION OF FLOW f- -// CM-4 CWR CHILLED WATER RETURN (UNDERGROUND) PIPE DROP IN DIRECTION OF j20W f - -CWS--4 CWS CHILLED WATER SUPPLY CONSULTANTS TEE CONNEC7701V OFF TOP OF PIPE f- 11 Cws-4 CWS CHILLED WATER SUPPLY (UNDERGROUND) h ff TEE CONNECTION OFF BOTTOM OF PIPE f -- -D� D DRAIN LINE Q ,-� WZ� n W w M L �} I D7R-4 DTR DUAL TEMPERATURE RETURN I-- 4 TEE CONNEC770AI OFF SIDE Of" PIPE f- -D75 --4 DTS DUAL TEMPERATURE SUPPLY UNION f - - - HPR- -f HPR HIGH PRESSURE CONDENSATE RE7URN f PIPE CAP f HPs --4 HPS HIGH PRESSURE STEAM (ABOVE 60 PSIG) Q f--11 HPS-4 HPS HIGH PRESSURE ' TEAM (UNDERGROUND) � }-� -f PIPE CAP ON DE:MOU770N PLAN f- -HRH HR HEAT PUMP CONDENSER RETURN f- I ►---f PIPE DEMOLISH TO POINT ON DEMOL177ON PLAN f - -HS —f HS HEAT PUMP CONDENSER SUPPLY f -,,- -f PIPE CONNECT 1'0 EXISTING OV NEW PLAN f- -H*R -4 HWR HEA7NG WATER RETURN DIRECTION OF FLOW f —HwS -f HWS HEATING WATER SUPPLY Z d- Q W f - - - LPR— - f LPR LOW PRESSURE CONDENSATE RETURN -� PITCH DOWN IN DIRECTION OF ARROW f - -LPS-4 LPS LOW PRESSURE STEAM (1 TO 15 PSIG) 0:�W ANCHOR POINT f -- -MPR --4 MPR MEDIUM PRESSURE CONDENSATE RETURN , v_ � J-' `�J EXPANSION LOOP (LxW) f MPS --f MPS MEDIUM PRESSURE STEAM (16 TO 60 PS(G) ALIGNMENT GUIDE' f - -MU -4 MU MAKE -UP WATER f —PD --f PO PUMP DISCHARGE' (CONDENSATE) �f� V D�G%STZ, FLEXIBLE PIPE CONNECTOR f— / /PD-4 PD PUMP DISCHARGE (CONDENSATE) (UNDERGROUND) �►t�. AUTOMA77C AIR VENT RHG REFRIGERANT HOT GAS � MANUAL AIR VENT f- -RL --f RL REFRIGERANT LIQUID NONE sheet M001 f -- -RSA RS REFRIGERANT SUCTION me " 06040 PRESSURE GAUGE WITH VALVE" f — ws --4 SMS SNOW MELT SUPPLY (GLYCOL) STEAM PRESSURE GAUGE Wl7H VALVE AND PIGTAIL f —AMR- f SMR SNOW MELT RETURN (GLYCOL) f - -sv -4 SV SAFETY RELIEF VENT LINE THERMOMETER f- —v -_4 V VENT LINE PRESSURE/TEMFERA7URE PLUG SITE f— - Dcw-4 DCW DOMESTIC COLD RAW WATER j L� PRESSURE TAP !PORTABLE GAUGE) f— - scw -4 SCW DOMESTIC SOFT COLD WATER 7NERM0 WELL (PORTABLE GAUGE) G - G---f G NATURAL GAS f A­4 A COMPRESSED AIR f-f(F+f IN LINE PUMP f— FOS —•f FOS FUEL OIL SUPPLY' c FLOW METER f FOR--f FOR FUEL OIL RETURN rrs� f--f FLOW SWITCH f --FOv----f FOV FUEL OIL VENT ® FD FLOOR DRAIN f f PRESSURE SENSOR ® AD AREA DRAIN f r PRESSURE SW1T(:H ® FS FLOOR SINK DIFFEREN77AL PRESSURE TRANSMITTER © RD ROOF DRAIN Qo ORD OVERFLOW ROOF DRAIN J� TEMPERATURE SENSOR CO CLEANOUT J 4 TEMPERA SWITCH STRAINER STRAINER WITH BLOW DOWN VALVE STEAM TRAP (FLOAT/7HERMOST477C) STEAM TRAP (BUCKET) STEAM TRAP (771ERMODYNAMI() f ---0-4 SIGHT GLASS (REFRIGERANT) f- *-4 AIR OR REFRIGERANT FILTER DRYER f-i -4 METER (W47ER /,AS) f-SZ-4 BACKFLOW PRESENTER ASSEMBLY 1-yf AQUASTAT MONITOR /,ONTROL SYMBOLS.• 0 THERMOSTAT OG 771ERA90STAT 4-771H CUARL• ON THERMOS TA T F•.7R NIGHT SETBACK �! ROOM SENSOR ®� ROOM SENSOR WITH GUARD HUMIDISTAT/HUMIDITY SENSOR O SENSOR ® STATIC PRESSURE SENSOR ® CARBON DIOXIDE SENSOR ® CARBON MONOXIDE SENSOR ® SPEED CONTROLLER SILICON CONTROLLER. REC71,FIER AlANUAL MOTOR STARi'ER/SWITCH SPECIAL TERMINOLOGY- UP ITEM PENETRATING STRUC7URAL PLANE ABOVE DOWN ITEM PENETRATING STRUCTURAL PLANE A BELOW. RISE 17EM INCREASES ELEVATION BUT DOES NOT C) PENETRATE STRUCTURAL PLANE ABOVE. DROP I7EM DECREASES ELEVATION BUT DOES NOT PENETRA7E STRUCTURAL PLANE BELOW. NOTE DESIGNA TIONS.• GENERAL NOTE GENERAL INFORMATION AS INDICATED ON A SHEET. APPLIES TO ENTIRE SHEET. PLAN NOE.• SPECIFIC INFORMATION AS INDICATED ON A SHEET. LEADER LINE OF PLAN N07F REFERENCED. DIRECTED TO ITEM OF PLAN N07E REFERENCED. 1 CIRCLE W17H NUMBER INDICATES A PLAN N07E REFERENCED W7774 771E NUMBER INDICATING THE ITEM NUMBER OF 771E PLAN N07E REFERENCED. DRAWING SYMBOLS- NORTH NORTH ARROW DIRECTION RISER /STACK NUMBER SHEET NUMBER WHERE RISER / STACK IS SHOWN DETAIL /SCHEMA77C/ENLARGED PLAN NUMBER r � SHEET NUMBER WHERE DETAIL /SCHEMA77CANLARGED PLAN IS SHOWN SEC71ONALEVA77ON DIRECTION SECTION/ELEVATION LETTER SHEET NUMBER WHERE SEC770NIELEVA77ON 15 SHOWN GENERAL NO TS: A. ALL SYMBOLS AND ABBREVIATIONS PRESENTED ON THIS SHEET MAY OR MAY NOT BE USED ON THE FOLLOWING SHEETS B. 7HESE S4IBOLS ON 771E MECHANICAL, E1�C7t7/CAL, PLUMBING , FIRE PROTFCT0N AND MEDICAL GAS SHEETS INDICATE ELECTRICAL EQUIPMENT PANELBOARDS, SWITCHBOARDS AND MOTOR CONTROL CENTERS. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 42' FRONT CLEAR WORKING SPACE AND, IN ADDITION, A CLEAR DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL CEILING ABOVE WI7H A WIDTH AND DEPTH OF THAT EQUIPMENT, IN ACCORDANCE WITH THE LATEST REVISION OF NFPA 70, NATIONAL ELECTRICAL CODE. REFERENCE SECTIONS 110 AND 384 OF THE NEC. NO PIPING, DUCT OR EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITEC7URAL APPURTENANCES, SHALL BE PERY177ED TO BE INSTALLED IN, ENTER OR PASS THROUGH, SUCH CLEAR SPACES OR ROOMS C. PIPES SHOWN ARE IN THE CEILING SPACE OF THE LEVEL/FLOOR ON WHICH THEY APPEAR, UNLESS 07HERWISE NOTED. D. EXISTING TO REMAIN WORK IS SHOWN WITH 7HIN112JGHT SOLID LINES E. EXISTING TO BE REMOVED OR RELOCATED WORK IS SHOWN WTH THICK/DARK DOTTED LINES. F: NEW OR RELOCATE' WORK IS SHOWN WTH 7RICK/DAP,K 5010 UN'ES: Cc?NNECT NEW TO EXISTING ELEVATION INDICATOR A PEVISION TRIANGLE L` C) REVISION CLOUD GENERAL NO TS: A. ALL SYMBOLS AND ABBREVIATIONS PRESENTED ON THIS SHEET MAY OR MAY NOT BE USED ON THE FOLLOWING SHEETS B. 7HESE S4IBOLS ON 771E MECHANICAL, E1�C7t7/CAL, PLUMBING , FIRE PROTFCT0N AND MEDICAL GAS SHEETS INDICATE ELECTRICAL EQUIPMENT PANELBOARDS, SWITCHBOARDS AND MOTOR CONTROL CENTERS. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 42' FRONT CLEAR WORKING SPACE AND, IN ADDITION, A CLEAR DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL CEILING ABOVE WI7H A WIDTH AND DEPTH OF THAT EQUIPMENT, IN ACCORDANCE WITH THE LATEST REVISION OF NFPA 70, NATIONAL ELECTRICAL CODE. REFERENCE SECTIONS 110 AND 384 OF THE NEC. NO PIPING, DUCT OR EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITEC7URAL APPURTENANCES, SHALL BE PERY177ED TO BE INSTALLED IN, ENTER OR PASS THROUGH, SUCH CLEAR SPACES OR ROOMS C. PIPES SHOWN ARE IN THE CEILING SPACE OF THE LEVEL/FLOOR ON WHICH THEY APPEAR, UNLESS 07HERWISE NOTED. D. EXISTING TO REMAIN WORK IS SHOWN WITH 7HIN112JGHT SOLID LINES E. EXISTING TO BE REMOVED OR RELOCATED WORK IS SHOWN WTH THICK/DARK DOTTED LINES. F: NEW OR RELOCATE' WORK IS SHOWN WTH 7RICK/DAP,K 5010 UN'ES: CONSULTANTS rTl Q W a� a. 0 8 W f h DO rn n O Lc) i cc;: 0 tt N w W z Q ,-� WZ� n W w M L �} Q Z X wW <Z F _ — Q �- pzw!0 Q L 0aag�o :3 r, Wzolfum =JDcCZ 04 r- 0 C.) zap r- a CrIM � Q 04 W 0 0 0 0 0 0 0 �00 Z ^ n aWi c c w 0�S w 2 Q z O C� Q_ > D L ON �1, m L O m �- Z d- Q W wQ 0Z 0 V Xz Q Z 0:�W J O OQ O Z `J m Q 0 0) V sr: �f� V D�G%STZ, No. ° 13815 STATE OF /HD 1 �►t�. 10.06.06 Dm"� CME Checked Bf KFY Cueajr Nwwm JDW sodw NONE sheet M001 Date 10/06/06 Pmject *MAW PVC 0990488 -10101 me " 06040