06120009.49
a co 0 N 0 0 m 0 0 N `o 3 0 0 rn w 0 0 (7) F- U w 0 ii PANELBOARD SCHEDULE NOTES.• 1. EACH DOUBLE OR MULTIPLE SEC77ON PANELBOARD SHALL HAVE SEC77ONS OF EQUAL HEIGHT MOUN7FD SIDE —BY —SIDE. EACH SEC77ON (EXCEPT LAST) SHALL HAVE SUBFEED LUGS FOR CABLE CONNEC77ON TO NEXT SECRON. 2 PROVIDE THE FOLLOWING CIRCUIT BREAKERS WHERE INDICATED. ST= CB WITH SHUNT 77?IP COIL, GFI= GROUND FAULT CIRCUIT IN7FRRUP7FR FOR PERSONNEL PRO TEC77ON, GFP= GROUND FAULT PRO 7FC77ON FOR EQUIPMENT, SFCB= CB MOUNTED IN SUBFEED POS177ON AND CONNECTED AHEAD OF THE MAIN CIRCUIT BREAKER, FR= PANELBOARD WITH FEED- 7HROUGH LUGS 3. MINIMUM AIC FAULT CURRENT SHALL BE 10,000 AMPS FOR 208YI120 AND 1201240 VOLT PANELBOARDS AND 14,000 AMPS FOR 480 Y12 77 VOLT PANELBOARDS WHEN NOT SPECIFICALLY NOTED OTHERWISE ABOVE. 4. FOR SERIES RA7FD PANELBOARDS PROVIDE CLEARLY MARKED LABEL INDICATING THE DEVICE IS INSTALLED PER PRESCRIBED SERIES CONNECTED UPS77?E4M FEEDER BREAKERS. 5. TYPICAL VOLTAGES: 120124OV, 1 -3; 240V, 3 -3; 208/120V, 3 -4; 4801277V, 3 -4; 480V, 3 -3. EQUIPMENT, MOTOR & CONTROL SCHEDULE PLAN N0. MA • LOAD BREAKER MANUAL STARTER it �o m Q QW , PHASE- WIRES ' 1 REMARKS °w o s 12m W o � U --j Ii \ u- w o s =>— a-m t2 cn o � O U = v _* mcn U O � Q 0 W o s �� Izm Lu N (n \ LL cn O Z W 1 FCU -1 112 HP 20811 — — — — — E 0 �o 3U ®oomo — — — — ©a — © ©ooaoa — — 2 ACCU -1 4.8 KW ©0000000aoao — — — — — — — — — — — ®mo E 30A ,: �o 3R TWO SECRON ., — 0000000a00000aooaooaaooaaaoaao 3 EF -1A,1B 118 HP 12011 E 1 S Y F — — — — — — — — — — — — — — TYPICAL OF TWO 4 EF -2 1 HP 208/3 — — 00 — — E 0000000a000a000aooaa0000aaooao HOA 30 6 AF — — — — — — — — — — 5 EF -3 1 HP 20813 — — — — — E 0 HOA 30 6 AF — — — 00 — — — 0000a0000a000000aooa000000000a — — 6 IR -1 1.8 A 12011 E 1 S Y S — — — — — — — — — — — — — — — 7 IR -2 1.8 A 12011 o0 1 S Y 000000vooa0000000000aooaaa000a — — — — — — — — — — — — — — — 8 IR -3 1.8 A 120 11 E 1 S Y S — — — — — — ao — — — ooaaa�a�oos�00000aa0000aaa00000 — — — — 9 IR -4 1.8 A 12011 E 1 S Y S — — — — — — — — — — — — — — — 10 MUAU -1 ■ao 208/3 — ono — ■�0000a�A���0000000000a000a000 — E 1 HOA 30 30AF — — E 30A NF 3 1 — — — 11 90001 LIFT 2 HP 20811 — — — — — — — — — oa — — E 000aooeooaoa�ooaooa0000000a000 NF 2 1 INT — TYPICAL OF TWO 1 12 MOTORIZED DOORS 112 HP 12011 — — — — — — — — — — — — E 30A NF 1 1 INT — TYPICAL OF FOUR 2 00 MOTORIZED GA IF 314 HP 20813 000aooa0000000aaoo — — — — — — — — — — — E 30A NF 3 3R INT — a000000aaoo 14 EDH -1 10 KW 208/3 — — — — — — — 00 — —. — 000000aooaoa000000 E 60A NF 3 1 INT — — 15 DAMPER 116 HP 12011 E 1 S Y S — 0 oa�000000o — — — — — — — — — — a 0 16 CF -1 000000vooa0000000a000a00000aoo 12011 E 1 S Y F — — — — — — — E 30A NF 1 1 — — TYPICAL OF THREE 17 COILING DOOR 114 HP 120 11 E 1 S Y S 00 — — — 0000a000000aoa000a000000000aoa — — — — — — — INT — — 3 o0 000000d00000000000000000000aaa o0 000000000000000000aaa0000aa0000 00 000a00000aoo 000000a000a000a000 00 00000aaoaoo oaoa0000000000000a o0 0000000aa00000000aoa000000000ao 00 ��ooa000ao�000a000aoa0000aoaa000 00 00000ao�00000 00000000�0000aoao Asa 000000a0000a 000a00000aoovaooe ■tea PANELBOARD SCHEDULE NOTES.• 1. EACH DOUBLE OR MULTIPLE SEC77ON PANELBOARD SHALL HAVE SEC77ONS OF EQUAL HEIGHT MOUN7FD SIDE —BY —SIDE. EACH SEC77ON (EXCEPT LAST) SHALL HAVE SUBFEED LUGS FOR CABLE CONNEC77ON TO NEXT SECRON. 2 PROVIDE THE FOLLOWING CIRCUIT BREAKERS WHERE INDICATED. ST= CB WITH SHUNT 77?IP COIL, GFI= GROUND FAULT CIRCUIT IN7FRRUP7FR FOR PERSONNEL PRO TEC77ON, GFP= GROUND FAULT PRO 7FC77ON FOR EQUIPMENT, SFCB= CB MOUNTED IN SUBFEED POS177ON AND CONNECTED AHEAD OF THE MAIN CIRCUIT BREAKER, FR= PANELBOARD WITH FEED- 7HROUGH LUGS 3. MINIMUM AIC FAULT CURRENT SHALL BE 10,000 AMPS FOR 208YI120 AND 1201240 VOLT PANELBOARDS AND 14,000 AMPS FOR 480 Y12 77 VOLT PANELBOARDS WHEN NOT SPECIFICALLY NOTED OTHERWISE ABOVE. 4. FOR SERIES RA7FD PANELBOARDS PROVIDE CLEARLY MARKED LABEL INDICATING THE DEVICE IS INSTALLED PER PRESCRIBED SERIES CONNECTED UPS77?E4M FEEDER BREAKERS. 5. TYPICAL VOLTAGES: 120124OV, 1 -3; 240V, 3 -3; 208/120V, 3 -4; 4801277V, 3 -4; 480V, 3 -3. EQUIPMENT, MOTOR & CONTROL SCHEDULE PLAN N0. EQUIPMENT OR MOTOR DESIGNATION LOAD VOLTAGE -PHASE MANUAL STARTER MAGNETIC STARTER �o m Q QW DISCONNECT AT MOTOR z cm ck- 0 w0O IZ U 0 L'—> cl: Y REMARKS °w o s 12m W o � U --j Ii \ u- w o s =>— a-m t2 cn o � O U = v _* mcn U O � Q 0 W o s �� Izm Lu N (n \ LL cn O Z W 1 FCU -1 112 HP 20811 — — — — — E 0 HOA 3U 10 AF — — — — — — — — — — 2 ACCU -1 4.8 KW 20813 — — — — — — — — — — — — E 30A NF 3 3R — — — 3 EF -1A,1B 118 HP 12011 E 1 S Y F — — — — — — — — — — — — — — TYPICAL OF TWO 4 EF -2 1 HP 208/3 — — — — — E 0 HOA 30 6 AF — — — — — — — — — — 5 EF -3 1 HP 20813 — — — — — E 0 HOA 30 6 AF — — — — — — — — — — 6 IR -1 1.8 A 12011 E 1 S Y S — — — — — — — — — — — — — — — 7 IR -2 1.8 A 12011 E 1 S Y S — — — — — — — — — — — — — — — 8 IR -3 1.8 A 120 11 E 1 S Y S — — — — — — — — — — — — — — — 9 IR -4 1.8 A 12011 E 1 S Y S — — — — — — — — — — — — — — — 10 MUAU -1 5 HP 208/3 — — — — — E 1 HOA 30 30AF — — E 30A NF 3 1 — — — 11 90001 LIFT 2 HP 20811 — — — — — — — — — — — — E 30A NF 2 1 INT — TYPICAL OF TWO 1 12 MOTORIZED DOORS 112 HP 12011 — — — — — — — — — — — — E 30A NF 1 1 INT — TYPICAL OF FOUR 2 13 MOTORIZED GA IF 314 HP 20813 — — — — — — — — — — — — E 30A NF 3 3R INT — AL TERNA TE BID 14 EDH -1 10 KW 208/3 — — — — — — — — — —. — — E 60A NF 3 1 INT — — 15 DAMPER 116 HP 12011 E 1 S Y S — — — — — — — — — — — — — — TYPICAL OF TWO 16 CF -1 FHP 12011 E 1 S Y F — — — — — — — E 30A NF 1 1 — — TYPICAL OF THREE 17 COILING DOOR 114 HP 120 11 E 1 S Y S — — — — — — — — — — — — INT — — 3 EQUIPMENT, M0 TOR & CONTROL SCHEDULE NOTES. 1. LOAD: A= AMPERES, FHP= FRAC77ONAL HORSEPOWER, HP= HORSEPOWER, KVA= KILOVOLT — AMPERES, KW= KILOWATTS, W= WATTS 2. OVERCURRENT PR07EC77ON (OCP): 3P -60A= 3 POLE, 60 AMPERE CIRCUIT BREAKER, 60AF= SWITCH WITH 60 AMPERE FUSE(S). 3. RESPONSIBILITY E= ELEC77?ICAL CONTRACTOR, EX= EXISTING, G= GENERAL CON7RACTOR, INT= INTEGRAL WITH EQUIPMENT, M= MECHANICAL CON77?ACTOR, 0= OWNER. FURNISH AND INSTALL: XF INDICATES FURNISHED BY X AND W INDICA7FS INSTALLED BY Y (EXAMPLE- MFEI= MECHANICAL CONTRACTOR TO FURNISH AND ELEC7RICAL CON7RACTOR TO INSTALL). SINGLE RESPONSIBILITY INDICATES BOTH FURNISH AND INSTALL. 4. CONTROLS. • HOA= HAND — OFF— AUTOMA77C SWITCH, S= ON —OFf SWITCH, HL= HIGH —LOW SWITCH, HLO= HIGH — LOW —OFF SWITCH, M= MOMENTARY ON —OFF SWITCH, ML= MOMENTARY HIGH —LOW SWITCH, MLO= MOMENTARY HIGH — LOW —OFF SWITCH, LOR= LOCAL — OFF— REM07E SWITCH. REMARKS NOTES.- Ol UP /DOWN PUSHBUTTON STA77ONS BY DOOR OPERATOR SUPPLIER INSTALLED AND WIRED BY EC. 2O LIFT BY OWNER WIRED BY EC, O3 KEY OPERATED STA77ON BY DOOR SUPPLIER INSTALLED AND WIRED BY E.C. CONTACTOR SCHEDULE PLAN POLES POLE AMPS COIL CIRCUIT COIL VOLTAGE DESCRIPTION OF LOAD LOAD CIRCUITS LOAD VOLTS C15 MH 3 30 MLPI -1 120V MAINTENANCE BUILDING INTERIOR LIGH77NG MLP1 -1,3 120V CONSULTANTS oz n 8y o o"o o a 1 z "" M w� 00 0) rl- o� L N ! cn 00 d' N W W Q z .-. 0Zr �- z Q L �L v) U l Z um) C( Q Z x �ZWZ _ — Q Q- >F- Q LL L o — 0 lx cr O I� = SJpGpZ N d n C a � gzzza a >1 Hz<cn cn Q N 0 0 0 0 0 0 0 —� coo z a� c c w a� U Q O ON LLi CONTACTOR SCHEDULE NOTES_ 1. TYPE- EH= ELEC7PICALL Y HELD, MH= MECHANICALLY HELD. 2. PROVIDE NEMA 1 ENCLOSURE. 3. BASED ON SQUARE D L /LX AND S SERIES FOR LIGHTING CONTACTORS 4. REFER TO CON7POL DIAGRAMS FOR AD61770NAL REQUIREMENTS CONSULTANTS oz n 8y o o"o o a 1 z "" M w� 00 0) rl- o� L N ! cn 00 d' N W W Q z .-. 0Zr �- z Q L �L v) U l Z um) C( Q Z x �ZWZ _ — Q Q- >F- Q LL L o — 0 lx cr O I� = SJpGpZ N d n C a � gzzza a >1 Hz<cn cn Q N 0 0 0 0 0 0 0 —� coo z a� c c w a� U Q O ON LLi LL Z_ d- � JQ W °w WZ U W Qo = Z wz c) X Z ,� X w O OQ Z _U Q O O sr: V `STf RF N0. ° 13815 STALE OF "ND IAN* 10.06.06 Dma TRL OmckW W. TO Q asy TO scft N.T.S. Shoot E900 D 10/06/06 PIC 0990488 -10101 06040