HomeMy WebLinkAbout08030167.3DESIGN /BUILD NOTES:
1. FIRE PROTECTION CONTRACTOR TO BE RESPONSIBLE FOR LOCATING SMOKE
DETECTOR DEVICES.
2. MECHANICAL DESIGN /BUILD CONTRACTOR TO BE RESPONSIBLE FOR FIGURING
CFM NUMBERS ON SUPPLY DIFFUSERS, AND FOR LOCATING RETURN AIR OUTLETS.
3. MECHANICAL DESIGN /BUILD CONTRACTOR TO BE RESPONSIBLE FOR LOCATING
THERMOSTATS AND COORDINATING LOCATION WITH OWNER AND TENANT'S FURNITURE.
4. ELECTRICAL DESIGN /BUILD CONTRACTOR TO BE RESPONSIBLE FOR PROVIDING
LIFE - SAFETY DEVICES WHERE REQUIRED BY CODE. SUCH AS EXIT SIGNS, HORNS,
STROBES AND SPEAKERS.
5. ELECTRICAL DESIGN /BUILD CONTRACTOR TO BE RESPONSIBLE FOR ALL
CIRCUITING OF OUTLETS AND LIGHT FIXTURES.
6. ELECTRICAL DESIGN /BUILD CONTRACTOR TO BE RESPONSIBLE FOR EMERGENCY
LIGHTING IN SPACE: EMERGENCY BATTERY PACKS OR NIGHT LIGHTS CONNECTED TO
EMERGENCY POWER SOURCE IS REQUIRED IF SPACE CONTAINS 100 PERSONS OR
MORE.
7. WHERE MULTIPLE SWITCHES ARE REQUIRED, PROVIDE ONE COVER PLATE.
GENERAL NOTES
1. ALL CITY & LOCAL PERMITS TO BE OBTAINED BY CONTRACTOR.
2. ALL WALLS TO BE 3 5/8" METAL STUDS W/ 5/8" GYP BD EITHER SIDE UNLESS NOTED
OTHERWISE.
3. ALL DOOR ROUGH OPENINGS SHALL BE FRAMED 4" FROM ADJACENT WALL CORNER
UNLESS OTHERWISE NOTED.
4. PROVIDE PLYWOOD BLOCKING IN NEW WALLS FOR ALL WALL HUNG ITEMS INCLUDING
MILLWORK, WALLSTOPS, CABINETRY, ETC. ALL WOOD BLOCKING MUST BE FIRE
TREATED. ALL WALL HUNG ITEMS THAT ARE TO BE HUNG ON EXISTING WALLS
WILL ALSO REQUIRE PLYWOOD BLOCKING.
5. ALL PLAN DIMENSIONS ARE TAKEN FROM FACE OF NEW GYPSUM PARTITION
OR FACE OF EXISTING CONSTRUCTION UNLESS OTHERWISE NOTED.
6. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD CHECKING ALL
DIMENSIONS AND MEASUREMENTS. IF JOB CONDITIONS PREVENT OBTAINING
DIMENSIONS OR RESULTS AS SHOWN OR SPECIFIED, THE CONTRACTOR SHALL BE
RESPONSIBLE FOR INFORMING DESIGN /APPLICATIONS, INC. BEFORE ANY
CONSTRUCTION IS STARTED.
7. EACH CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AS INDICATED ON THE
DRAWINGS AND REPORT ANY DISCREPANCY THAT MAY OCCUR TO THE GENERAL
CONTRACTOR. ANY IRREGULARITIES SHALL BE REPORTED TO DESIGN /APPLICATIONS,
INC., FROM THE GENERAL CONTRACTOR.
8. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO DESIGN /APPLICATIONS,
INC. FOR APPROVAL, ON ALL MATERIALS OR ITEMS IF THE CONTRACTOR CHOOSES
TO DEVIATE FROM THAT SHOWN ON THE DRAWINGS OR IF THE DRAWING DOES
NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER.
9. GENERAL CONTRACTOR SHALL EXPEDIATE PREPARATION AND SUBMITTAL OF ALL
SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR FOR CHECKING, FABRICATION,
AND /OR ORDERING AND DELIVERY OF MATERIALS & EQUIPMENT.
10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OVERSEEING THAT ALL
MATERIALS AND LABOR SHALL BE IN ACCORDANCE WITH THE BEST QUALITY
STANDARDS OF THE RESPECTED TRADE. THE GENERAL CONTRACTOR SHALL BE
RESPONSIBLE FOR OVERSEEING THAT ALL WORK SHALL BE IN ACCORDANCE WITH
THE STATE UNIFORM BUILDING CODES AND STANDARDS FOR ALL GENERAL
CONSTRUCTION, MECHANICAL, AND ELECTRICAL WORK AND LOCAL AND FEDERAL
CODES AND STANDARDS.
11. ALL DETAILS, MATERIALS, AND INSTALLATIONS OF SAME ARE SUBJECT TO APPROVAL
BY DESIGN /APPLICATIONS, INC. AND FINAL APPROVAL BY THE OWNER.
\A/- 1
3 5/8" METAL
STUD FRAMING
® 16" 0. C.
5/8" GYPSUM
WALLBOARD
EACH SIDE
WALL TO EXTEND
TO DECK ABOVE
& SEAL.
INSULATION TO BE
INSTALLED ABOVE
FINISHED CEILING
3' OUT EITHER SIDE.
Ind
WALL TYPES
NO SCALE
NOTE: ALL WALLS TO BE W -3 UNLESS NOTED OTERWISE.
3 5/8" METAL
STUD FRAMING
0 16" 0. C.
5/8" GYPSUM
WALLBOARD
EACH SIDE
3 1/2" INSULATION
WALL TO EXTEND TO
UNDER SIDE OF
FINISHED CEILING.
ALL WALLS TO BE
W2 UNLESS NOTED
OTHERWISE.
\A/ - ._�
3 5/8" METAL
STUD FRAMING
® 16" 0. C.
5/8" GYPSUM
WALLBOARD
EACH SIDE
WALL TO EXTEND TO
UNDER SIDE OF
FINISHED CEILING.
OVERALL PLAN
FIRST FLOOR
G2
NO SCALE
ARCHITECTURAL PLAN Gz
SCALE: 1/8" = 1' -0-
H&R BLOCK FINANCIAL ADVISORS GENERAL NOTES:
1. CONTRACTOR TO NOTIFY /SUBMIT TO CC /DESIGNER ANY BUILDING STANDARD SPECIFICATIONS.
2. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS. NOTIFY CC /DESIGNER OF ANY DISCREPANCIES FOUND
DURING SITE SURVEY.
3. ELECTRICAL DEVICES HAVE NOT BEEN FIELD VERIFIED; RECEPTACLES AND SWITCHES SHOWN ARE FOR
REFERENCE ONLY. CONTRACTOR TO PROVIDE NEW ELECTRICAL DEVICES AS INDICATED ON PLAN IF AN EXISTING
ELECTRICAL DEVICE IS NOT WITHIN 12" OF DEVICE INDICATED.
4. ALL CHANGES AND REVISIONS MUST BE DIRECTED AND APPROVED BY HR BLOCK CC /DESIGNER.
5. CONTRACTOR TO PROVIDE FOR SEPARATE HVAC CONTROLS FOR HR BLOCK SPACE, PROVIDING A SUPPLY AND
RETURN IN EACH ROOM IF REQUIRED FOR NEW CONSTRUCTION. IF ADDITIONAL UNITS ARE REQUIRED TO
ACCOMPLISH SEPARATE CONTROLS, CONTACT CC /DESIGNER.
6. A SWITCH SHALL BE INSTALLED AT EACH MEANS OF EGRESS FROM DEMISED SPACE AND EACH INDIVIDUAL
ENCLOSED AREA AS INDICATED ON PLAN. CONTRACTOR TO INSTALL NEW SWITCH CORRESPONDING WITH EXISTING
SWITCHES.
7. PRIMER - 1 COAT OF SW PREPRITE 400 INTERIOR LATEX, B28W400 EGGSHELL FINISH -2 COATS OF SW
PROMAR 400 INTERIOR LATEX EGGSHELL, B30W451. COLORS AS NOTED IN SPECIFICATIONS. CONTACT JERRY
SCHULL AT 800.217.0871 WITH ANY QUESTIONS.
8. FORMULA FOR CUSTOM COLOR "DARK CLARY SAGE" BI -2y10; G2 -29; Y3 -4y16
9. DOOR /SIDELIGHT FRAMES: " BRONZETONE" (FROM SHERWIN WILLIAMS "ALL SURFACE ENAMEL BRONZETONE
CUSTOM COLOR" SELECTION), UNLESS BUILDING STANDARD FRAME COLOR IS REQUIRED.
10. ALL DOORS TO BE SOLID CORE BIRCH, UNLESS BUILDING STANDARD.
11. U.O.N. HARDWARE SPECIFICATIONS FOR DOOR: SCHLAGE AL SERIES- DESIGN: SATURN FINISH: #626 "SATIN
CHROMIUM PLATED" PASSAGE LATCH: AL10S; LOCKSET: AL53PD, UNLESS BUILDING STANDARD.
12. ALL FLOORING MATERIAL TO BE ORDERED FROM FLOOR SCOUTS INC. (314) 997 -3436.
13. ALL VCT FLOORING TO BE CLEANED AND WAXED UPON COMPLETION OF INSTALL.
14. DATA ROOM REQUIREMENTS: THE ROOM MUST HAVE AIR CONDITION VENTS WITH ADJUSTABLE DIFFUSERS AND BE
WELL VENTILATED. INCLUDE EXHAUST FAN AND CONSULT CC FOR ALTERNATE VENTILATION METHODS.
15. CONTRACTOR TO PROVIDE BLINDS FOR ALL EXISTING EXTERIOR WINDOWS TO MATCH EXISTING OR TO MATCH
BUILDING STANDARD. IF BLINDS EXIST IN THE SPACE, CONTRACTOR TO PROVIDE AND INSTALL NEW BLINDS TO
MATCH EXISTING WINDOW COVERINGS WHERE BLINDS ARE DAMAGED OR REMOVED. IF BLINDS DO NOT EXIST,
CONTRACTOR TO PROVIDE COST TO SUPPLY AND INSTALL BLINDS IN ALL EXTERIOR WINDOWS.
LEGEND:
EXISTING WALL TO BE REMOVED
EXISTING WALL TO REMAIN
f
\ NEW FULL HT WALL CONSTRUCTION
SEE WALL TYPES FOR DETAILS.
= =W
EXISTING DOOR AND FRAME TO BE REMOVED
EXISTING DOOR AND FRAME TO REMAIN
170 NEW DOOR AND FRAME
MATCH EXISTING
ARCHITECTURAL NOTES:
OCONTRACTOR TO PROVIDE AND INSTALL
6' -0" MANUAL CEILING MOUNT PROJECTION
SCREEN ® 12" AWAY FROM FINISH WALL.
CONFIRM EXACT LOCATION W/ TENANT.
OPROVIDE BLOCKING FOR A 30LB 3'x3'
LOGO. LOGO TO BE CENTERED BEHIND
THE RECEPTION DESK. REFER TO PAGE 5
FOR BLOCKING DETAIL.
OCONTRACTOR TO PROVIDE ALTERNATE
COST TO DEMO DOOR, SIDELIGHT, AND
PARTITION AS SHOWN. REUSE DOOR AND
SIDELIGHT IF ABLE.
OLOCKSET: SEE GENERAL NOTE #11. KEY
SEPARATELY W/ MASTER KEY
OCONTRACTOR TO PROVIDE APPROPRIATE
HARDWARE FOR THE MOUNT OF CEILING
MOUNTED PROJECTOR, FIELD STAFF TO
DETERMINE EXACT LOCATION, SIZE &
HEIGHT, TENANT SUPPLIED PROJECTOR.
OCONTRACTOR TO CREATE 3' -0" CASED
OPENING TO MATCH HEIGHT OF EXISTING
DOOR FRAMES.
INSTALL FULL HEIGHT SIDE LIGHTS TO
MATCH DOOR HEIGHT IN 3 EQUAL
SECTIONS. FRAME TO MATCH EXISTING
WOOD FRAME OF DOORS, START 4 "AFF.
O
C�
r-
r7
T CV
v CO n
a CO
c .� cp 00
rn
Of N
CO
o
cy) .U�
cn
o r--
C)
° o
O L X
P4
O
O
ED
N
w
� w
�F-4z
CO a
L) E-
O
� W A
Co Z
m
z
Revisions:
W
W
E-+
W
t,
,lJ
a LLi �
3 r- U
Al
Issue:
STATE SUBMITTAL
Date:
26 FEBRUARY 2008
Sheet:
Al -01