HomeMy WebLinkAbout08030167.3DESIGN /BUILD NOTES: 1. FIRE PROTECTION CONTRACTOR TO BE RESPONSIBLE FOR LOCATING SMOKE DETECTOR DEVICES. 2. MECHANICAL DESIGN /BUILD CONTRACTOR TO BE RESPONSIBLE FOR FIGURING CFM NUMBERS ON SUPPLY DIFFUSERS, AND FOR LOCATING RETURN AIR OUTLETS. 3. MECHANICAL DESIGN /BUILD CONTRACTOR TO BE RESPONSIBLE FOR LOCATING THERMOSTATS AND COORDINATING LOCATION WITH OWNER AND TENANT'S FURNITURE. 4. ELECTRICAL DESIGN /BUILD CONTRACTOR TO BE RESPONSIBLE FOR PROVIDING LIFE - SAFETY DEVICES WHERE REQUIRED BY CODE. SUCH AS EXIT SIGNS, HORNS, STROBES AND SPEAKERS. 5. ELECTRICAL DESIGN /BUILD CONTRACTOR TO BE RESPONSIBLE FOR ALL CIRCUITING OF OUTLETS AND LIGHT FIXTURES. 6. ELECTRICAL DESIGN /BUILD CONTRACTOR TO BE RESPONSIBLE FOR EMERGENCY LIGHTING IN SPACE: EMERGENCY BATTERY PACKS OR NIGHT LIGHTS CONNECTED TO EMERGENCY POWER SOURCE IS REQUIRED IF SPACE CONTAINS 100 PERSONS OR MORE. 7. WHERE MULTIPLE SWITCHES ARE REQUIRED, PROVIDE ONE COVER PLATE. GENERAL NOTES 1. ALL CITY & LOCAL PERMITS TO BE OBTAINED BY CONTRACTOR. 2. ALL WALLS TO BE 3 5/8" METAL STUDS W/ 5/8" GYP BD EITHER SIDE UNLESS NOTED OTHERWISE. 3. ALL DOOR ROUGH OPENINGS SHALL BE FRAMED 4" FROM ADJACENT WALL CORNER UNLESS OTHERWISE NOTED. 4. PROVIDE PLYWOOD BLOCKING IN NEW WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALLSTOPS, CABINETRY, ETC. ALL WOOD BLOCKING MUST BE FIRE TREATED. ALL WALL HUNG ITEMS THAT ARE TO BE HUNG ON EXISTING WALLS WILL ALSO REQUIRE PLYWOOD BLOCKING. 5. ALL PLAN DIMENSIONS ARE TAKEN FROM FACE OF NEW GYPSUM PARTITION OR FACE OF EXISTING CONSTRUCTION UNLESS OTHERWISE NOTED. 6. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD CHECKING ALL DIMENSIONS AND MEASUREMENTS. IF JOB CONDITIONS PREVENT OBTAINING DIMENSIONS OR RESULTS AS SHOWN OR SPECIFIED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR INFORMING DESIGN /APPLICATIONS, INC. BEFORE ANY CONSTRUCTION IS STARTED. 7. EACH CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THAT MAY OCCUR TO THE GENERAL CONTRACTOR. ANY IRREGULARITIES SHALL BE REPORTED TO DESIGN /APPLICATIONS, INC., FROM THE GENERAL CONTRACTOR. 8. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO DESIGN /APPLICATIONS, INC. FOR APPROVAL, ON ALL MATERIALS OR ITEMS IF THE CONTRACTOR CHOOSES TO DEVIATE FROM THAT SHOWN ON THE DRAWINGS OR IF THE DRAWING DOES NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. 9. GENERAL CONTRACTOR SHALL EXPEDIATE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR FOR CHECKING, FABRICATION, AND /OR ORDERING AND DELIVERY OF MATERIALS & EQUIPMENT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OVERSEEING THAT ALL MATERIALS AND LABOR SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE RESPECTED TRADE. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OVERSEEING THAT ALL WORK SHALL BE IN ACCORDANCE WITH THE STATE UNIFORM BUILDING CODES AND STANDARDS FOR ALL GENERAL CONSTRUCTION, MECHANICAL, AND ELECTRICAL WORK AND LOCAL AND FEDERAL CODES AND STANDARDS. 11. ALL DETAILS, MATERIALS, AND INSTALLATIONS OF SAME ARE SUBJECT TO APPROVAL BY DESIGN /APPLICATIONS, INC. AND FINAL APPROVAL BY THE OWNER. \A/- 1 3 5/8" METAL STUD FRAMING ® 16" 0. C. 5/8" GYPSUM WALLBOARD EACH SIDE WALL TO EXTEND TO DECK ABOVE & SEAL. INSULATION TO BE INSTALLED ABOVE FINISHED CEILING 3' OUT EITHER SIDE. Ind WALL TYPES NO SCALE NOTE: ALL WALLS TO BE W -3 UNLESS NOTED OTERWISE. 3 5/8" METAL STUD FRAMING 0 16" 0. C. 5/8" GYPSUM WALLBOARD EACH SIDE 3 1/2" INSULATION WALL TO EXTEND TO UNDER SIDE OF FINISHED CEILING. ALL WALLS TO BE W2 UNLESS NOTED OTHERWISE. \A/ - ._� 3 5/8" METAL STUD FRAMING ® 16" 0. C. 5/8" GYPSUM WALLBOARD EACH SIDE WALL TO EXTEND TO UNDER SIDE OF FINISHED CEILING. OVERALL PLAN FIRST FLOOR G2 NO SCALE ARCHITECTURAL PLAN Gz SCALE: 1/8" = 1' -0- H&R BLOCK FINANCIAL ADVISORS GENERAL NOTES: 1. CONTRACTOR TO NOTIFY /SUBMIT TO CC /DESIGNER ANY BUILDING STANDARD SPECIFICATIONS. 2. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS. NOTIFY CC /DESIGNER OF ANY DISCREPANCIES FOUND DURING SITE SURVEY. 3. ELECTRICAL DEVICES HAVE NOT BEEN FIELD VERIFIED; RECEPTACLES AND SWITCHES SHOWN ARE FOR REFERENCE ONLY. CONTRACTOR TO PROVIDE NEW ELECTRICAL DEVICES AS INDICATED ON PLAN IF AN EXISTING ELECTRICAL DEVICE IS NOT WITHIN 12" OF DEVICE INDICATED. 4. ALL CHANGES AND REVISIONS MUST BE DIRECTED AND APPROVED BY HR BLOCK CC /DESIGNER. 5. CONTRACTOR TO PROVIDE FOR SEPARATE HVAC CONTROLS FOR HR BLOCK SPACE, PROVIDING A SUPPLY AND RETURN IN EACH ROOM IF REQUIRED FOR NEW CONSTRUCTION. IF ADDITIONAL UNITS ARE REQUIRED TO ACCOMPLISH SEPARATE CONTROLS, CONTACT CC /DESIGNER. 6. A SWITCH SHALL BE INSTALLED AT EACH MEANS OF EGRESS FROM DEMISED SPACE AND EACH INDIVIDUAL ENCLOSED AREA AS INDICATED ON PLAN. CONTRACTOR TO INSTALL NEW SWITCH CORRESPONDING WITH EXISTING SWITCHES. 7. PRIMER - 1 COAT OF SW PREPRITE 400 INTERIOR LATEX, B28W400 EGGSHELL FINISH -2 COATS OF SW PROMAR 400 INTERIOR LATEX EGGSHELL, B30W451. COLORS AS NOTED IN SPECIFICATIONS. CONTACT JERRY SCHULL AT 800.217.0871 WITH ANY QUESTIONS. 8. FORMULA FOR CUSTOM COLOR "DARK CLARY SAGE" BI -2y10; G2 -29; Y3 -4y16 9. DOOR /SIDELIGHT FRAMES: " BRONZETONE" (FROM SHERWIN WILLIAMS "ALL SURFACE ENAMEL BRONZETONE CUSTOM COLOR" SELECTION), UNLESS BUILDING STANDARD FRAME COLOR IS REQUIRED. 10. ALL DOORS TO BE SOLID CORE BIRCH, UNLESS BUILDING STANDARD. 11. U.O.N. HARDWARE SPECIFICATIONS FOR DOOR: SCHLAGE AL SERIES- DESIGN: SATURN FINISH: #626 "SATIN CHROMIUM PLATED" PASSAGE LATCH: AL10S; LOCKSET: AL53PD, UNLESS BUILDING STANDARD. 12. ALL FLOORING MATERIAL TO BE ORDERED FROM FLOOR SCOUTS INC. (314) 997 -3436. 13. ALL VCT FLOORING TO BE CLEANED AND WAXED UPON COMPLETION OF INSTALL. 14. DATA ROOM REQUIREMENTS: THE ROOM MUST HAVE AIR CONDITION VENTS WITH ADJUSTABLE DIFFUSERS AND BE WELL VENTILATED. INCLUDE EXHAUST FAN AND CONSULT CC FOR ALTERNATE VENTILATION METHODS. 15. CONTRACTOR TO PROVIDE BLINDS FOR ALL EXISTING EXTERIOR WINDOWS TO MATCH EXISTING OR TO MATCH BUILDING STANDARD. IF BLINDS EXIST IN THE SPACE, CONTRACTOR TO PROVIDE AND INSTALL NEW BLINDS TO MATCH EXISTING WINDOW COVERINGS WHERE BLINDS ARE DAMAGED OR REMOVED. IF BLINDS DO NOT EXIST, CONTRACTOR TO PROVIDE COST TO SUPPLY AND INSTALL BLINDS IN ALL EXTERIOR WINDOWS. LEGEND: EXISTING WALL TO BE REMOVED EXISTING WALL TO REMAIN f \ NEW FULL HT WALL CONSTRUCTION SEE WALL TYPES FOR DETAILS. = =W EXISTING DOOR AND FRAME TO BE REMOVED EXISTING DOOR AND FRAME TO REMAIN 170 NEW DOOR AND FRAME MATCH EXISTING ARCHITECTURAL NOTES: OCONTRACTOR TO PROVIDE AND INSTALL 6' -0" MANUAL CEILING MOUNT PROJECTION SCREEN ® 12" AWAY FROM FINISH WALL. CONFIRM EXACT LOCATION W/ TENANT. OPROVIDE BLOCKING FOR A 30LB 3'x3' LOGO. LOGO TO BE CENTERED BEHIND THE RECEPTION DESK. REFER TO PAGE 5 FOR BLOCKING DETAIL. OCONTRACTOR TO PROVIDE ALTERNATE COST TO DEMO DOOR, SIDELIGHT, AND PARTITION AS SHOWN. REUSE DOOR AND SIDELIGHT IF ABLE. OLOCKSET: SEE GENERAL NOTE #11. KEY SEPARATELY W/ MASTER KEY OCONTRACTOR TO PROVIDE APPROPRIATE HARDWARE FOR THE MOUNT OF CEILING MOUNTED PROJECTOR, FIELD STAFF TO DETERMINE EXACT LOCATION, SIZE & HEIGHT, TENANT SUPPLIED PROJECTOR. OCONTRACTOR TO CREATE 3' -0" CASED OPENING TO MATCH HEIGHT OF EXISTING DOOR FRAMES. INSTALL FULL HEIGHT SIDE LIGHTS TO MATCH DOOR HEIGHT IN 3 EQUAL SECTIONS. FRAME TO MATCH EXISTING WOOD FRAME OF DOORS, START 4 "AFF. O C� r- r7 T CV v CO n a CO c .� cp 00 rn Of N CO o cy) .U� cn o r-- C) ° o O L X P4 O O ED N w � w �F-4z CO a L) E- O � W A Co Z m z Revisions: W W E-+ W t, ,lJ a LLi � 3 r- U Al Issue: STATE SUBMITTAL Date: 26 FEBRUARY 2008 Sheet: Al -01