HomeMy WebLinkAbout05060062-site Plan~lote:
Contractor should verify site
specific Infermati0n depicted
hereon with the approved
construction clans for this
developmenl
Note:
Minimum Front ya~ I - 25'
Minimum Side Yah - 3
Minimum Aggregal ~ * 6'
(Between He~ses)
Minimum Rear Yar I-N/A
SAN MH
TC=768.6(
I 1st Fir FFE = 769.8
I B~t FFE = 760.0
I Gard Window = 764.01 3 CAR
Note: Retainthg~
system for grading may ~ 1,0 f~et above cu~
be necessa~ for
garden basements,
SAN SEWER
TA,,NANA DRIVE
50R/W (3o' Bc-.c
SAN MH
TC=767.00
HYD
I'~1
5' WALK
LOT ¢/: t 10
Flood Hazard Note:
Lot Number 110 lies within that Special Flood Hazard 29ne
MANCHESTER 4C
THREE CAR
GAR
"X" per the sealed location on the Flood insurance Ral, Maps
for Hamilton County, Indiana (Commun~J Panel
#180§7C0227F, dated February 19, 2003).
Note:
This drawing is based upon construction plans and/or i ~cord
drawings prepared by others ane is not bacee upon a ~ aid suwey.
COOn Consulting & Land Ssrv cea. Corp~ does no wa rant the
correctness or ntegdty ofthla information. The contrac,[or/owner
should ratify existing conditions pdor to construction ,~,~y vary ng
fie d condlt oas or any dlacrapancy with the Information ccotalnec~
hereon shou d be lmmed ately reported to COOn Cons Jlting & Land
Services, Corp.; failure to do so woud result in the conlractodowners
assumption of Ilab [tv.
20,71'
15' D.U.&S.E,
62.85'
43
/
TC--766,90
/
//
STREET
593-2667 (7651 345-5943 FAX#:
JOB #2003-100.110
STMINLET
TC=760.00
------ = Drainage Flow
[ XX,X = Existing Grade
I P,blic Walk Sq Ft = +687
Sod Sq Yds = ;507__ __
LSeeding Sq Ft = +59_55
The proposed construction greees depicted hereon are based upon
information, proposad grades a~d/or contours, taken from t~e
approved coostructlon plans prepared for this subdivision. Un,ess
s~ated hereon, no Information pertaining [o but not limited to,
fluctuating wate~ teale elevations, soil types or conditions within the
building area of said lot. has been provided or referenced on said
plans, With the construction of a basement, it is recommended that
the lowest floor elevation be constructed at least two (2) feet above
any adjoining bodies of waler unless a study of facts reveals
otherwise. Should any ground water be wlthesseddurtng the
excavation of said structure, the lowest floor elevation should be
ra sod at least two (2 feet above the ground wa(er level and
additional conslruotion techniques shou d be ncorporated to
alleviate f~ture problems
INSTR. #200400061680
PC 3. SLIDE 452
C,O,C, INSTR. #200400076921
LOT# 110
6087 TANANA DRIVE
CARMEL, IN 46033
PLOT PLAN
Pulte Homes of Indiana