HomeMy WebLinkAboutC209 - add 1.pdf ENLARGED UTILITY PLAN C209 1" = 20' Job No. Date:July 6, 2012 Scale: Sheet: FO R CO N S T R U C T I O N P L A N S 11 6 t h S t r e e t RE V I S I O N S DA T E DE S C R I P T I O N MA R K Ca r m e l , I n d i a n a PR E P A R E D B Y : Title: TH E C E N T R E PR E P A R E D F O R : 12016L 83 6 5 K e y s t o n e C r o s s i n g , S u i t e 2 0 1 In d i a n a p o l i s , I N . 4 6 2 4 0 ( 3 1 7 ) 2 0 2 - 0 8 6 4 RE T A I L C E N T E R BENCHMARK INFORMATION ORIGINATING BENCHMARK - HAM G-55: A BRONZE PLATE ON A CONCRETE POST PROJECTING 1.3 FEET OUT OF THE GROUND ALONG US-31, 2.6 MILES NORTH OF I-465, 0.7 MILES SOUTH OF 131st STREET, 83 FEET WEST OF THE CENTERLINE SBL OF US-31 AND 19 FEET EAST OF THE R/W FENCE AT STATION 409+00. GREENFIELD DISTRICT ELEVATION: 866.76' (VERTICAL DATUM: NAVD88) TEMPORARY BENCHMARK - CUT "+" SET ON NORTH NORTHEAST BONNET BOLT OF FIRE HYDRANT APPROXIMATELY 120' SOUTH OF THE NORTHEAST CORNER OF THE SURVEYED TRACT. ELEVATION 838.76' (VERTICAL DATUM: NAVD88) 7/ 1 6 / 1 2 CI T Y R E V I E W C O M M E N T S 1 7/ 2 0 / 1 2 AD D E N D U M 1 8/ 1 4 / 1 2 FD C A N D F I R E H Y D R A N T R E L O C A T I O N 3 8/ 2 0 / 1 2 ON B S T A T E R E L E A S E S E T 4 8/ 2 7 / 1 2 ON B B I D S E T AP P R O V A L P E N D I N G NO T F O R CO N S T R U C T I O N 9/ 7 / 1 2 AD D R E S S C A R M E L E N G I N E E R I N G C O M M E N T S 9/ 1 5 / 1 2 AD D R E S S C A R M E L E N G I N E E R I N G , S W P P P & C R O S S R O A D C O M M E N T S 9/ 2 4 / 1 2 AD D R E S S C A R M E L E N G I N E E R I N G & S W P P P C O M M E N T S FLOOD ZONE STATEMENT UTILITY NOTES REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING PLANS FOR CONTINUATION OF UTILITIES WITHIN 5 FEET OF STRUCTURES. PRESSURE UTILITY MAINS AND SERVICE LINES MAY NEED TO BE INSTALLED AT A DEPTH GREATER THAN THAT SPECIFIED OR SHOWN ON THE DRAWINGS TO CLEAR EXISTING AND PROPOSED CROSSING UTILITIES. IN SUCH CASES, THE CONTRACTOR SHALL INSTALL VERTICAL BENDS AS REQUIRED TO ACHIEVE APPROPRIATE CLEARANCE BETWEEN THE CROSSING UTILITIES. A MINIMUM HORIZONTAL SEPARATION OF 10 FEET BETWEEN WATER LINES AND SEWERS SHALL BE MAINTAINED AT ALL TIMES. A MINIMUM VERTICAL SEPARATION OF 18 INCHES BETWEEN WATER LINES AND SEWERS SHALL BE MAINTAINED AT CROSSINGS. IN THE EVENT THAT MINIMUM SEPARATION REQUIREMENTS CANNOT BE MET, THE CONTRACTOR SHALL UTILIZE PRESSURE-TYPE WATER PIPE FOR THE SEWER PER DETAIL SA-9. WATER MAINS SHALL BE INSTALLED WITH A MINIMUM OF 54 INCHES OF COVER AS MEASURED FROM THE TOP OF THE PIPE TO THE FINAL FINISH GRADE ABOVE THE PIPE. THRUST BLOCKS OR JOINT RESTRAINTS SHALL BE INSTALLED ON ALL WATER LINES AT ALL BENDS, TEES AND HYDRANTS PER THE DETAILS. PIPE LENGTHS SHOWN ARE MEASURED FROM CENTER TO CENTER OF STRUCTURES ROUNDED TO THE NEAREST FOOT. PIPE LENGTHS SHOWN FOR STORM SEWERS ARE MEASURED TO THE DOWNSTREAM END OF END SECTIONS. WHERE GRADE MODIFICATIONS (CUT OR FILL) ARE SHOWN ADJACENT TO EXISTING VALVE BOX COVERS AND MANHOLE CASTINGS, THE VALVE BOX COVERS AND MANHOLE CASTINGS SHALL BE ADJUSTED FLUSH WITH THE PROPOSED GRADE. ADJUSTMENTS OF EXISTING MANHOLE CASTINGS TO GRADE TO A MAXIMUM OF 12 INCHES SHALL BE MADE USING PRECAST CONCRETE ADJUSTING RINGS PROVIDED THE TOTAL HEIGHT OF EXISTING AND NEW ADJUSTING RINGS DOES NOT EXCEED 12 INCHES. ADJUSTMENTS OF CASTINGS WHERE THE TOTAL HEIGHT OF ADJUSTING RINGS WOULD EXCEED 12 INCHES SHALL BE MADE BY REPLACING THE CONE AND/OR BARREL SECTION OF THE STRUCTURE. PAVEMENTS, WALKS, CURBS AND OTHER SURFACE IMPROVEMENTS REQUIRING REMOVAL FOR INSTALLATION OF UNDERGROUND UTILITIES SHALL BE RESTORED TO THEIR PRESENT CONDITION UNLESS OTHERWISE SHOWN. MANHOLE CASTINGS LOCATED WITHIN ASPHALT PAVEMENT AREAS SHALL INCLUDE A CONCRETE PAVED COLLAR EXTENDING A MINIMUM OF 12 INCHES IN ALL DIRECTIONS FROM THE EDGE OF THE CASTING PER THE DETAILS. SANITARY LATERAL PIPE MATERIAL SHALL BE PVC, ASTM D-3034, SDR-35. EXISTING BUSINESSES WILL REMAIN OPEN WHILE CONSTRUCTION IS UNDERWAY. UTILITY RELOCATIONS SHALL BE COORDINATED WITH THE OWNER AND THE UTILITY COMPANIES INVOLVED AND MAINTAIN UTILITY SERVICES TO THE EXISTING BUSINESSES TO REMAIN OPEN AS MUCH AS POSSIBLE. NO EARTH DISTUBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 12. 11. 10. 9. 8. 7. 6. 5. 4. 3. 2. 1. 13. 14. SD EME HCT G C.O. D.S. DESCRIPTIONDESCRIPTION LEGEND OF PROPOSED UTILITY IMPROVEMENTS S W 825.50 200 IE 821.50 SEE EXISTING CONDITIONS PLAN FOR EXISTING UTILITY FEATURES LEGEND. EXISTING UTILITY LINE TYPES ARE NOTED WITHIN BRACKETS [ ]. NOTES: 100 The utilities shown hereon have been located from field survey information and existing drawings. The surveyor makes no guarantee that the utilities shown comprise all such utilities in the area, either in service or abandoned. The surveyor further does not warrant that the utilities shown are in the exact location indicated although he does certify that they are located as accurately as possible from information available. UTILITY STATEMENT: THIS SITE LIES ENTIRELY WITHIN FLOOD HAZARD ZONE X PER FIRM MAP FOR THE CITY OF CARMEL, INDIANA COMMUNITY PANEL NO. 18057C0209F, DATED FEB. 19, 2003, THE ACCURACY OF THIS FLOOD HAZARD STATEMENT IS SUBJECT TO MAP SCALE UNCERTAINTY AND TO ANY OTHER UNCERTAINTY IN LOCATION OR ELEVATION ON THE REFERENCED FLOOD INSURANCE RATE MAP. NOTES: IF IT WILL BE NECESSARY TO RELOCATE EXISTING UTILITIES, THE EXPENSE OF SUCH RELOCATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. ALL UTILITY POLES SHALL BE LOCATED WITHIN ONE FOOT OF THE PROPOSED RIGHT-OF-WAY. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT NOTE: ALL PROPOSED STORM SEWERS, DETENTION STRUCTURES, AND STORMWATER QUALITY TREATMENT BMP'S ARE PRIVATE. 15. SW UNDERGROUND DETENTION SYSTEM EMERGENCY OVERFLOW ELEVATION SE UNDERGROUND DETENTION SYSTEM EMERGENCY OVERFLOW ELEVATION PLAN VIEW OF EMERGENCY OVERFLOW SECTION VIEW OF EMERGENCY OVERFLOW