Loading...
HomeMy WebLinkAboutF2.2 - add 1.pdfGENERAL FOUNDATION / CONGRETE NOTES MISCELLANEOUS: The structure and its severol purts hove been designed for the in-service loods only. The methods, means, procedures, and sequences of construction are the responsibility of the Contractor. The Contractor shall take all necessary precautions to insure safe working conditions and maintain the integrity of the structure during all stages of construction. The adequacy of the design of temporary bracing, shoring, etc. is the contractor's responsibility. FWNDA710NS: Foundation excavations shall be made to plan elevations. Foundations are to bear on firm, undisturbed soil. The soil conditions beneath foundations shall then be inspected by a qualified Geotechnical Engineer. Where unacceptable soils occur, excavate and replace with an acceptable engineered fill or lower the bottom of the footing to an accepable elevation. Foundations and soils related work shall be performed in accordance with the geotechnical report and inspected by a qualified Geotechnical Engineer. Geotechnical Report prepared by PSI dated August 6, 2012. Report No. 0016-596. Design Net Soil Pressures: Spread Footings: 2,000 psf Continuous Wall Footings: 2,000 psf Assumed net soil pressures are as noted above. It is the contractor's responsibility to verify existing conditions and allowable pressures prior to casting foundations. Foundation conditions noted during construction, which differ from those described in the geotechnical report shall be reported to the Architect, Structural Engineer and Geotechnicol Engineer before construction is continued. CONCRETE: Reinforced concrete has been designed in accordance with the current "Building Code Requirements for Structural Concrete" (ACI 318). Mixing, transporting, and placing of concrete shall conform to the latest edition of the "Specifications for Structural Concrete for Buildings" (ACI 301). Concrete in the following areas shall consist of natural sand fine aggregate and normal weight coarse aggregates conform(ng to AS7M C33, Type 1 Portland Cement conforming to ASTM C150, and shall have the following compressive strength (F'c) at 28 days: Footings and Mats: 3,000 psi Slabs-on-Grade: 3,500 psi Retoining Wolls, Curbs, Sidewolks ond Slobs Exposed to De-icers: 4,000 psi (6% +/- 19> entrained air by volume) Concrete (flowable fill or lean concrete) used as fill under footings or as backfill behind walls shall consist of natural sand fine aggregate, Type 1 Portland Cement conforming ASTM C150 (50 pounds minimum), and type C or F Fly Ash, and have a compressive strength (F'c) at 28 days of 75 psi. Concrete compressive strength tests shall be performed in accordance with AS7M C39. Copies of the test results shall be forwarded directly to the Structural Engineer. One set of specimens shall be taken for each day's pour of appreciable size and for each 100 cubic yards in accordance with the latest edition of ASTM C31. Each set shall include one specimen tested at 7 days, 2 specimens tested at 28 days and one specimen retained in reserve. This set of test cyfinders shall be protected against freezing. Slump tests shall be made prior to the addition of plasticizers. Where concrete is placed by pumping methods, concrete for test cylinders and slump tests shall be taken at the point of final placement. Adjustment of slump by adding water to the mix at the job site shall occur as follows. Adjustment shall be made one time only with a maximum of 2 gallons of water per cubic yard such that the specified slumps and water / cement ratios are not exceeded. The concrete shall be mixed after the addition of water one minute per cubic yard to a maximum of 5 minutes. Protect the concrete surface between finishing operations on hot, dry days or any time plastic shrinkage cracks could develop by using wet burlap, plastic membranes or fogging. Protect concrete deck at all times from rain, hail or other injurious effects. Use of construction joints at locations other than those indicated on the drawings shall be submitted to the Structural Engineer for approval. The Contractar shall submit for review by the Structural Engineer a mix design for each proposed class of concrete. Mix designs shall show weight proportions for components of the mix. The Contractor shall not vary from the mix design without the approval of the Structural Engineer. CONCRETE SLABS-ON-GRADE: Slabs-on-grade shall be constructed in accordance with the latest edition of the "Guide for Concrete Floor and Slab Construction" (ACI 302.1R). In addition to the specifications noted elsewhere, the normal weight concrete for flatwork shall conform to the following: Minimum Cement Content: 5 sacks / cyd Maximum Water To Cement Ratio by Weight: 0.48 Maximum Slump Prior to Addition of Plasticizers: 3 inches Maximum Slump if Plasticizers are not used: 4 inches Minimum cement content shall be 6 sacks/cyd and max w/c ratio shall be 0.43 for Curbs, Sidewalks and Slabs exposed to de-icers. Slabs-on-grade shall be placed to achieve the following minimum tolerances: Overall Values: Ff = 25 FI = 20 Local Values: Ff = 17 FI = 15 Place concrete in a manner so as to prevent segregation of the mix. Floating and troweling operations shall not occur until the concrete has lost surface water sheen or all free water. Do not sprinkle free cement on the slab surface. Provide curing of concrete slabs immediately after finishing using a sprayed on liquid curing compound. Other methods may be used with the Structural Engineer's approval. Subgrade modulus for slab on grade design: 100 p.c.i. CONCRETE REINFORCEMENT: Reinforcing bar detailing, fabricating, and placing shall conform to the latest edition of the following standards: "Specificotians for Structural Concrete Buildings" (ACI 301) ond "ACI Detuiling Munuol" (SP66). Reinforcing steel shall be deformed bars of new billet steel conforming to ASiM A615 and shall have a minimum yield strength of 60,000 psi. Provide standard bar chairs and spacers as required to maintain concrete protection specified. Welded wire fabric shall be smooth wire fabric conforming to AS7M A185 unless otherwise noted. Fabric shall be supplied in flat sheets and lapped a minimum of 14 inches. Welded wire fabric in slabs-on-grade shall be placed 2" down from the top of the slob unless otherwise noted. Slab on metal deck shall be reinforced with 6x6 - W1.4 x W7.4 WWF placed 3/4" down from the top of the slob. Unless otherwise shown or noted, splicing of reinforcing bars shall conform to the current ACI 318. Where the length of lap is not shown or noted, provide a Class "B" lap at splices. The Concrete Contractor shall prepare detailed working or shop drawings to enable fabrication, erection and construction of the work in accordance with the drawings and specifications and shall submit one electronic copy to the Structural Engineer for approval. These shop drawings will be reviewed for design concepts expressed in the contruct documents only. The Controctor shall be responsible for all dimensions, accuracy, and fit of work. NON-SHRINK GRWT: Grout shall be a non-metallic, shrinkage resistant (when tested in accordance with the lotest edition af ASTh1 C827 or CRD-C621�, premixed, non-corrosive, non-staining product containing Portland Cement, silica sands, shrinkage compensating agents and fluidity improving compounds. Grout shall have a minimum compressive strength (F�c) of 5,000 psi in 28 days. Grout compressive strength tests shall be performed in accordance with the latest edition of ASTM C709. MASONRY: Engineered concrete masonry has been designed in accordance with the latest edition of the "Building Code Requirements for Concrete Masonry Structures" (ACI 531) by the American Concrete Institute (ACI). Concrete masonry construction shall conform to the latest edition of the "Specification for Concrete Masonry Construction" (ACI531.1). Provide special inspections of all masonry construction. Concrete masonry construction shall have a minimum compressive strength (F'm) of 1,500 psi at 28 days. Mortar shall be Type M below grade and Type M or S above grade proportioned in accordance with the latest edition of ASTM C 270 or C 476. Reinforcing steel for bond beams and vertical block cores shall be deformed bars of new billet steel complying with AS7M A 615 and having a minimum yield strength of 60,000 psi. Unless otherwise noted, masonry cores (where specified on drawings) and bond beams shall be filled with concrete meeting the following requirements. Minimum 2,500 psi 28-day compressive strength with 3/4-inch maximum aggregate and 7 inch maximum slump. Unless otherwise noted, provide a steel bear(ng plate with two 3/8-inch x 6" stud anchors at beam bearings. Bearings for beams, lintels, joists, etc. shall be bond beams or hollow masonry units with cores filled solid with concrete. See drawings for minimum bearing requirements. DESIGN DATA: The building structure has been designed in accordance with the 2006 International Building Code with Indiana Amendments. Roof Loads: Live Load 25 psf Snow Load 20 psf Dead Load 25 psf (Ground Snaw Load= 20 psf, Ce= 1.0, Ct= 1.0, I= 1.0) VYfnd DesPgn Data: * Basic Wind Speed - 90 mph, Exposure C • Main Wind Force Resisting System (P) - ASCE 7 * Base Design Pressure - 15.9 psf * Components and Cladding (P) - ASCE 7 * wnd Importance Factor (I) - 1.0 Componenta and Cladding: Area (Walls) 10 SFT 100 SFT 500 SFT In field of Wall: -18.6, +17.2 -16.1, +14.6 -14.3; +12.9 wthin 8'_0" of _22.9, +17.2 -17.8, +14.6 -14.3, +12.9 Corners: Areo (Roaf) 10 SFT 100 SFT 500 SFT In field -18.8 -17.2 -17.2 Perimeter -31.5 -20.3 -20.3 Corner -31.5 -20.3 -20.3 * Perimeter strip is 8'-0" � Roof Seiamic Deaign Data: + Seismic Use Group = I, (Ie=1.0) SCALE� SAW CUT OR USE SPECIAL BLACK SLOTS FOR CORNER BLOGK � DOWELS SEE STRUGTURAL SECTIONS BUTTER FACE SNELL RAKE AT GONTROL JOINT ONLY. LEGEND: A � 16" LONG BLOGK B � S" LONG BLOCK CANTROL JOINT KEY AS SPECIFIED O� A B A 00 A B A I1 � JCANTROL JOINT -SEALANT EXTERIOR FACE OF WALL � EXTERIOR FAGE NorE: SASN BLOCK SASN BLOGK AS SNOWN ABOVE IS APPLICABLE TO THE CONSTRUCTION OF ALL CONTROL JOINTS EXGEPT WNERE STEEL AND CANCRETE COLUMNS OCGUR AND SFIALL BE USED AT EACFI LOCATION WFIERE C.J. IS INDICA?ED ON ARCNITECTURAL FLOOR PLANS OR ELEVATION DR4WING. SAS I C CONTROL JOI NT (CJ � SGALE: NONE ---� --` v� G I/2" DCPANSION- �JOINT MATERIAL FILL WITH ��CANCRE?E� -� - -o ' a e. COLUMN � PER PLAN LINE OF BASEPLATE � BELIXN -EDGE OF SLAB EXTERIOR OR �� � ��� I_�� ► G •C SEE PLAN AS REQ'D AS REQ'D (TYP.) (TYP.) I/2" DCPANSION G`�� JOINT MATERIAL h FILL WIT --- -- ° i GONGRETE i `?-6 � �a �' a PER PLAN . INE OF BASEPLATE BELOW EDGE OF SLAB EXTERIOR AS REQ'D (TYP.) G"� ry 0 � � -=-�, � N � � Q � i i i 0 ;i p � <� J � N� . - •- � S'`e °'°SS -° TYp I CAL COLUMN I SOLAT I ON JOI NTS • s.(.z seo)= i�.s�,, s�(i.a seo)= �.s� * Spectral Response Coefficients Sos & Sa = 0.191, 0.126 * Seismic Design Category (1616.3) = B NO SGALE * Basic Seismic-Force-Resisting System = Structural Steel Systems not spec(flcally detailed for seismic resistance; R=3.00, Cd=3.00 * Design Base Shear (Cs= 0.064) + Analysis Procedure - ELFP � H� u - LL ~ �p �w w � I/8" 5 a s JOINT ... w �. K r rp r° � � SLAB REINFORCING PER PLAN N� o� .. .,. . ; v FORMED KEYWAY CONSTRUCTION JOINT r� � V �� GONTROL JOINT GONSTRUGTION JOINT TYPICAL SLAB ON GRADF JOINTS SCALE� NIXJE DIAMOND DOWELS E� 24" O.C. >o v. . v .���� N W N � ALTERNATE CANSTRUGTION JOINT ;_ � � � � 0 rc a � � � Q � O � a � rW. Uz � � O � H C� x Va 6 � : _ __ �� � _=a° € �am ^- �sm=., V rt�+ � C C � � V M W �� � *+ :� d= � Q .� d � rt+ � C Z � V 'd d O i � ov � C � U C z° �r o � a �� r ui C Y- .. � m� E .°, o V � ' v n ° �� � � � � I- _ .-I ri M K m "' � 9 � m C W � C m W OI � C C �- N C � W � W �; U N L r+ T r Scope Draringc� m::e ara ���e���me m< rm : oi me en xm95 9en p�o� � �« ma.a�.oi a.: . i m. a�m 9n nc p �ultlin . g � molor o e �ype �slmtluml, macM1Onlwl antl�eletl��lwl ayatems�� � �.�e a.��� ao �o� �,w, a�„ ��� .orv e�i.,a o, mu erto�a,a a�e �romri,u� oi u<�� 2aw2�m: m m< co�wa. p On 0e boA.c ol I�e ge�eml ° oll i�¢m¢ leJ or tlav te6 ��. e,ae. o.�oa�ao9 .oe�� ,.a.,�.d e, �.. „oP, � mwe�o�'o��� . Revicbns� OWNERREVIEW OB/22/12 BID SET OS/29/12 leaus Dsts DnWn By Checked By 08/27/12 D.T.C. T.G.S. GENERAL NOTES AND FOUNDATION DETAILS Dnwln9 Numben ONB-F2.2 Pro�eet NumDen 12-116