HomeMy WebLinkAboutE3MATCHLINE
New 200A LP3
Panel "LP3"
waft
Dimmer 6DR
Rack 'n
'i
i LP3 -I K
°
Existing Panel
....... ..... ..................... . . . . .. ...------- ....._...... - -
- - - - - -- -------- - - - - -- - - - - - - - - - - - - - - - - - - - - - -
i
DFC
�t
7xi_LP3 -11,13 i
- K
- - -- _
R,- LP3 -5
- -- - - - - - -- - - --
ii I
it tall K �+-
:
:
I^ i
I
:
F
......... -------- - -- --- - - - - -- -- - - - - -- - - - -- .... --- _:.: _ -- a .w __--- - -.:.. : ::_:- - -- - - - - -- �- -------- ._ _ _._...._ _- -____. - - - - -- - - - - -- -. ...._ -.. -
- _i
TA'R
+err
Emergency Egress Light
®
4 Tube Surface Fluorescent Fixture
Exit Fixture (Wall Mounted)
-= = ----- ---------------------
LP3-
—''- - -- -
Remove All Surface Mounted
_ -
Fixtures and Gondult in
®4
- _ - _ - -__
QF
Room 201 - Amphitheatre
-
-
- - - --
Single Pole Switch
C = =:3
Wall Mounted Fluorescent Fixture
I'.
......
_.
-- - - - --
- ----- ----- -- --- - -
- - - - -- -
- - -- - - - - - -- -- - . - -- . .- __ -....- - ...:
---- - - - - -- ------------ ( =
. �,.__ To Dimmer Pack °
i {
t _ I DR- 11 - - - - -- - - -- - - --
,» i r
r--
- F - - -- - - - - -- -- ----- .. ........ .. ...... ......... ............ . . .. - -- - - - - - -- --------- -------------- ............... - - -- ....
t� .�.. ------------ .. . . . . .. - ........ -- - ._...- - - -... - - - - - -- - - - - --
.-
itew�rr
1 -- •------- - - - - -- ----- ._._.. _ .
Lighting Conduits to Terminate at Dimmer
Pack, by A.V. Lighting Contractor - Coordinate
wi A.V. Contractor
iman�'milimilill'i 11' 11 1111111111111M I
C, =='fit _C
NA`/
5="L0^
Unless Noted Otherwise
Existing Lighting to Remain
Repair as Required.
L 16HT1 N6
d SECOND FLOOR PLAN -C
SCALE: 118" = 1' -0"
I
».. ---
lt�f? Panel "SP -t" w/
4olated Ground
SA
---- - - - - --
!
KI•YPLAN
--------------------------------- -- - - - - -- - - - - -- :-------------- -- -- - - - t - - - -- - - -- - - -- - - - - - - - — - - - - - -- -
I ,
f- -�
SYiuBOL LSD
2 Tube Strip Fluorescent Fixture
Emergency Egress Light
®
4 Tube Surface Fluorescent Fixture
Exit Fixture (Wall Mounted)
®
Exit Fixture (Gelling Mounted)
Tube Surface Fluorescent Fixture
i
®4
Night Lite Circuit (Inner Lamps Only)
QF
Exhaust Fan
-
-
-0-
Single Pole Switch
C = =:3
Wall Mounted Fluorescent Fixture
I'.
!
I-
! ...
�i
Dimmer Switch
O
Recessed Incandescent Downlight
Jh-
Three -Way Switch
�
Track Fixture
Three -Way Dimmer Switch
�t
Wall Mounted Incandescent
Existing Lighting (Surface d
aSurface
Mounted Downllght
Recessed )
"3
Wall Mounted Up/Down Sconce
`.."psi �•�w+M ina. ,' 1
-.
102 - 6holr is to be Removed, Runs to be Re -used or
Gapped, and Circuits Utilized as Needed.
To Dimmer Rack
See 2: E3
- - - -- ------ - - - - --
° DR -0I
DR -OS
\-
r.........
r. t - - - - -- - - - - -- - LI
w4 : X
Ll
r
l
--
Existing Light/Fan Combinations
Relocated As Shown'
l:
------------------
,---------- - - - -.- !
7 «� ..
r
°
DR12 -DR23 (24) #10 in 114 "c. -
AV Plug Strip d Mounting
Pipe by AV Contractor
M -06 Connection by E.G. (Typ)
J J
A A ; " ° T
DR24-DR40 r�� Locate Fixture at Location
of Existing Hanging Fixture
(36) #10 in IV2"c. Typical Fixtures A d G
>R -0? °
J J
T
! I ®
3_11
r�
!�i'�c to AV Outlet In X
Ba' ony .5e 2.EI
i y -( °
N. C. "nt on Beam 3_ R.
--- - - -. ----- - - - - -. - -- - - - - - ._
Y -
IR42 -DR45� '
......._ - -
- --
_-oa -------- - -- -- - = =r
DR -10 fir•
i
L L ' L L L L L -- -- __
-�
X..-
,.
L L L L "L L L L L
�.,
I!
3_11\
LL L L L L L L v L _ ..._........ .................... ........ ............................ . .- ;- - --
- -- - - - - --
_ \
Unless Noted Otherwise
Existing Lightin to Remain
L16HTIN6
/ FIRST FLOOR PLAN - A
5GALE: 1/8" 1' -0"
KEYPLAN
C A L L A H A N
A S S O C I A T_ E S
A R C H I T E C T U RE/PLAN N I N G
KEVIN CALLAHAN, A.I.A.
Circle Tower Suite 1400
55 Monument Circle
Indianapolis, Indiana 46204
_ 317- 637 -1570
A Professional Corporation
PARTIAL o
- - - - - - -- I-- - - - - -- PLAN M
B N
_ l
mot•
PARTIAL a
PLAN
A
N a
t�, W
�o V)
Z
Ix
�C O
q 7
'r W
N
w
O
V W
a
a
E-.
W W
Er
L a
Con
Iva
`O
try
W
Re- UseAke- Locate Fixtures
This Room As Required
Repair as Required. N
"r
ISSUE DATE:
AUGUST 26, 1993
REVISION • DATE
°�s••.itio,�Nr,.:�R PROJECT 93- 0016 -00
it It SHEET NO.
M — IN
�Q
or st TNJC.&J-
Q 1993 UNDER PENALTY OF LAW
L16HTIN6 FLOOR PLANS (A and
i
-
-
- - -;
rut
---------------- - --
I'.
!
I-
! ...
I
It
`.."psi �•�w+M ina. ,' 1
-.
102 - 6holr is to be Removed, Runs to be Re -used or
Gapped, and Circuits Utilized as Needed.
To Dimmer Rack
See 2: E3
- - - -- ------ - - - - --
° DR -0I
DR -OS
\-
r.........
r. t - - - - -- - - - - -- - LI
w4 : X
Ll
r
l
--
Existing Light/Fan Combinations
Relocated As Shown'
l:
------------------
,---------- - - - -.- !
7 «� ..
r
°
DR12 -DR23 (24) #10 in 114 "c. -
AV Plug Strip d Mounting
Pipe by AV Contractor
M -06 Connection by E.G. (Typ)
J J
A A ; " ° T
DR24-DR40 r�� Locate Fixture at Location
of Existing Hanging Fixture
(36) #10 in IV2"c. Typical Fixtures A d G
>R -0? °
J J
T
! I ®
3_11
r�
!�i'�c to AV Outlet In X
Ba' ony .5e 2.EI
i y -( °
N. C. "nt on Beam 3_ R.
--- - - -. ----- - - - - -. - -- - - - - - ._
Y -
IR42 -DR45� '
......._ - -
- --
_-oa -------- - -- -- - = =r
DR -10 fir•
i
L L ' L L L L L -- -- __
-�
X..-
,.
L L L L "L L L L L
�.,
I!
3_11\
LL L L L L L L v L _ ..._........ .................... ........ ............................ . .- ;- - --
- -- - - - - --
_ \
Unless Noted Otherwise
Existing Lightin to Remain
L16HTIN6
/ FIRST FLOOR PLAN - A
5GALE: 1/8" 1' -0"
KEYPLAN
C A L L A H A N
A S S O C I A T_ E S
A R C H I T E C T U RE/PLAN N I N G
KEVIN CALLAHAN, A.I.A.
Circle Tower Suite 1400
55 Monument Circle
Indianapolis, Indiana 46204
_ 317- 637 -1570
A Professional Corporation
PARTIAL o
- - - - - - -- I-- - - - - -- PLAN M
B N
_ l
mot•
PARTIAL a
PLAN
A
N a
t�, W
�o V)
Z
Ix
�C O
q 7
'r W
N
w
O
V W
a
a
E-.
W W
Er
L a
Con
Iva
`O
try
W
Re- UseAke- Locate Fixtures
This Room As Required
Repair as Required. N
"r
ISSUE DATE:
AUGUST 26, 1993
REVISION • DATE
°�s••.itio,�Nr,.:�R PROJECT 93- 0016 -00
it It SHEET NO.
M — IN
�Q
or st TNJC.&J-
Q 1993 UNDER PENALTY OF LAW
L16HTIN6 FLOOR PLANS (A and