Loading...
HomeMy WebLinkAbout0495.93.22N I rn O I z 0 Q) Q3 D c:v �J STAKING COORDINATES ( `I to UTILITY EASEMENT POINT NORTHING EASTING POINT NORTHING EASTING TELEPHONE VAULT FOR PSI PRIMARY CABLE PSI PRIMARY 1295.04' 1 3605.00 5063.69 23 2703.60 5470,65 I �BY I_B.T. CABLE >, /� N 88'4517 E IV - - - - - - - - - - 2 3606.50 5176.35 24 2634.19 5390.98 II _ - -- - - -- 3 3617.94 . 25 2618.05 5443.37 - - - 4 3653.83 5356.60 26 3148.81 5656.01 T _1`___ --�PCSED rASEMENT - - - - - - I 5 3552.43 5063.85 27 3015.84 5658.90 �� TO INDIANA BELL TELEPHONE 4 ,I 60' 6 3456.37 5179.61 28 2882.88 5661.79 1 5' CON (CA) 45' BLDG. SETBACK 44 - -- 7 3459.47 5322.08 29 2715.60 5665.43 _ 8 3261.42 5183.85 30 3153.05 5850.97 II I -- 9 3264.51 5326.32 31 3020.08 5853.86 I I i 2 3 - ,ter - SB (CA} - - - - - I 10 3189-20 5050,66 32 2887.11 5856.75 li {�F (CA) i -- I 11 3136.05 5050.75 33 2767.40 5859,35 SB (CA} I Q 12 3135.99 5066.15 34 2818.1$ 5992.49 2N #6, 1 ti #10 GND, 1 "C Lo 13 - 3003-02 5 069.04 35 2859.75 6022.03 i I + SB (CA) - -- - 14 2870.05 .77 5071-93 36 3157.29 6045.92 15 2742.77 5111.91 37 3005.32 6049.23 TO BE = I 2- #6, 1 - #10 GND, 1 "C SA j 16 3140.34 5266.11 38 3153.09 6230.46 RELOCAT -UY 43 (CA} 17 3007, 37 5269.00 39 3199.01 6263.08 1 l/ ° U 18 2874.40 5271.89 40 3218.24 6176.35 ` 4" EMPTY o SII 2 0 19 2746.52 5274.67 41 3343.27 6188.65 (CA) I PVC SEE NOTE #4 - - -� 20 3144.57 5461. 06 42 3466.74 6185.96 5 21 3011.61 5463.95 43 3580.72 6183.49 rX- -X - -X 22 2878.64 5466.84 44 3644.13 6063.18 W II x IU I i 2 - #6, 1 - #10 GND, 1 "C x i x x 10' w00D FENCE I x v 42 I - - - - - -- 7 W 6 A S O cA , I I c% N ( ) x ; -- � ° 2-#6, 1-#10 GND, 1"C SA(CA) SA ' ° O { i j (CA) ! _ c C I X W ° t f ! D.S. #3 _ - -- m U ; x LLJ i ow Y w x 00 J � I �Z 2 - #4 PVC FOR Ix Dw - 0 TELEPHONE SERVICE I ow o f i SEE NOTE #11 x 0 o 0 w a x 2- #6, 1- #10 GND, 1 "C j PSI PRIMARY CABLE 41 � SA(CA) __-10' WOOD � n -X-,� FENCE C4 x PRIMARY ELECTRICAL TRANSFORMER PAD SERVICE. SEE NOTE #5 I o x f j 0 c, x 8 U) I w d ° - , 2, #6, 1, #10 GND, 1 "C SA CA (CA) ° PKG LOT LIGHTING -CKT NO.1 / C) ( ) i PKG LOT LIGHTING -CKT NO.2 ' Q ENTRANCE m x SEE NOTES s % � 6 AND #7 ENTRANCE � \ 40 2- #6, 1- #10 GND, 1' C # to x ° ° SC F PAD MOUNTED M TERING CA S TELEPHONE SVC t ( ) (CA ENCLOSURE BY P I SFi 0 - Lx--x x ° -x -X� - ., 39 PC) m 2-4 EMPTY ^� K�IVH METER ON �>o W o 2-4" PVC SEE NOTE #4 JUNISTRUT SUPPORT PVC SEE NOTE 4 2� #4, 3� #6, 1N #8 GND, 1 1/4 "C 2N #4, 3N #6, 1� #8 CND, 1 1/4 "C 2N #4, 2N #6, 1- #8 GND, 1 1/4 "C - 2N #6, 1 ti #10 GND 1 „C # -- ' 2 - #4, 2- #6, 1, #8 GND, 1 1/4"C 7- 11 1 SF (CA A 38 SD AB (AB) 36 SC) (BC) I ) 2 N # r #6, 1 10 /GND, 1"C ' � r BCJ 16 SA(AB) I 20 SD(AB) ( ) , , � 12 / 1 Q I Z w I o I 2-#6, 1- #10 GND,11 "C % 2- #6, 1,#1C GND, 1"C-/ Li 2-0, 1- #10 GND, 1 "C ,/ j /ELECTRICAL LEGEND W „ 2 7 LIGHT POLE __\ j FINSHED PAVEMENT OR UNDERGROUND UTILITY GRADE LEVEL MARKING TAPE 12° MAX_ (FUSE PER BALLAST � /l^ MANUFACTURE) I - #6 BARE COPPER, - UNDISTURBED j 1" CHAMFER GROUND WIRE IN 1/2° PVC CONDUIT ANCHOR BOLTS 4 REQ'D) EACH. 36" MIN_ (616)- 459 -8327 FOR NATIONAL ACCOUNT PRICING. �} SOIL 3" MIN. - GRANULAR BACKFILL o Ir co y VOLTS. HOUSING COLOR: WHITE PAINT. POLE: 27' -6 ", NOTE 13 O WIDELITE #XLS- 1000 -2 -480 -S -WHITE 12 " 6• MIN. CONDUIT AS - PARKING LOT. SPECIFIED OL #125- 29 -F -1- 480- 1000HPS WHITE \ - FINE GRANULAR 400 WATT, HIGH PRESSURE SODIUM, SIDE MOUNTED, BACKFILL TYPICAL TRENCH DETAIL ' N TS LIGHT POLE __\ /-GROUND LUG INSIDE POLE "BUSS" 600V,WATERTIGHT \ i OPPOSITE HANDHOLE INLINE FUSE HOLDERS. / PROVIDE BUSHINGS / ON CONDUITS (FUSE PER BALLAST � /l^ MANUFACTURE) % i BASE PLATE COVER #6 BARE COPPER, PAINT, POLE: 24' -0" WITH 4" O.D. X 6" TENON, NOTE 13. j 1" CHAMFER GROUND WIRE IN 1/2° PVC CONDUIT ANCHOR BOLTS 4 REQ'D) EACH. rn (616)- 459 -8327 FOR NATIONAL ACCOUNT PRICING. SB / WITH TWO NUTS CUTOFF TYPE LUMINAIRE WITH HORIZONTAL LAMP, AND o Ir co y VOLTS. HOUSING COLOR: WHITE PAINT. POLE: 27' -6 ", NOTE 13 INSTALL SQUARE WITH WIDELITE #XLS- 1000 -2 -480 -S -WHITE LITHONIA #KAS31000S -R4- 480- SP12 -DWH Z MCGRAW #GLA91225 -FT WHITE PARKING LOT. OL #125- 29 -F -1- 480- 1000HPS WHITE 0 400 WATT, HIGH PRESSURE SODIUM, SIDE MOUNTED, 0 SEAMLESS SONOTUBE TYPE FORM ' z COLOR: WHITE PAINT. POLE: 27' -6 ", NOTE 13 000 FOR CONCRETE BASE.(REMOVE SONOTUBE a i GRADE LEVEL EMCO #PAED- 3H -40OS -480 WHITE W AFTER CONCRETE SETS, RUBFINISH) 1000 WATT METAL HALIDE, SIDE MOUNTING, (2) FIXTURES PER � o wM _ VOLTAGE: 480 VOLTS. HOUSING COLOR: WHITE PAINT. POLE: > w j CADWELD OR C) Lo J o0 ! -- n3 TIES @16" O,C.* N DOUBLE LUG CONNECTION � � z Q_ SP REINF. (4 REQ'D) ,��, SPACE EVENLY SF Q x f� w CONDUITS (PVC) SCH 40 WITH I - Z o LONG SWEEP ELBOWS 10' -On X 3/4" Q a' o ;COPPER CLAD Uy 0 �- �� GROUND ROD MIN. Of o * ALL RESTEEL GRADE 60, ASTM A615 Lij o- m DIMENSION SCHEDULE TYPE 'SA'; SB`X =8' -0 Z & 'so' Y =2' -6 " DDIA- Z =2' -6° NOTE: TYPE -x- X =8' -0° BASE TO BE SACK -RUB FINISHED, NOT PAINTED LIGHT POLE BASE DETAIL N TS 1 2- #4, 2-0, 1- #8 GN , 1 1/4 C SA ,/ SYMBOL DESCRIPTION o xQ ~ SA SA (AB) (BC) 37 / / ,�/ - ❑�❑ z I SE (g) 17 SA - - ` Q 21 (AB) A(BC ,' ;% ,� ��'` SA (AB) TWIN MOUNT LIGHT FIXTURE GRADE � T z- INDICATES PHASE EARTH / DENOTES FIXTURE TYPE N i / -- BACKFILL I I ' W Z I' � j � %� SC (Age SIDE MOUNT LIGHT FIXTURE RED OR YELLOW Q'✓ INDICATES PHASE WARNING TAPEI_ 2-#6, 1-#10 CND, 1 "C DENOTES FIXTURE TYPE - p -\ -2 # 6 1N 10 GND,1 "C / 3 j so DECORATIVE ENTRANCE LIGHT Z I ( �/ �;� / SA (&B POST MOUNT LIGHT FIXTURE. 14 22 28 32 , ,�� INDICATES PHASE W 18 " SA DENOTES FIXTURE TYPE 5 r✓ w O q BC DE 0 ES U E E - .•. S SA(BC) (AB) (AB) i I 2 EMPTY SF rp� F9 L I �C) / � r C � ( ) CONDUIT CONCEALED OR BURIED .. • PV T 4 SEE E C � CO N DU IT C APP ED . OF 35 � tu 4 SCHEDULE .. � I 1 I I ( \_ _ / 0 CONDUIT TURNING UP 40 PVC �� �i�i 2,#6, 1-#10 GND 1"C x L I I I ut 1-#10 I C)' 16 \ CO N R T E SF (� POLE NUMBE R ENCASEMENT - 2� # CND, 1 "C , � % co 2-#4, 2^, #6, 1 N #8 GND, 1 1 /4 "C 33 ,l BLDG. SETBACK � 19 SA(BC) I I I �� C F SC (BC) -_� _ '� �' EN ( �- T o Iry ON B » _'-� 2 4 EMPTY 23 � I � (AB) _�� v q v � TO BE RELOCATED ASSN A„ SEE NOTE 4 / `� � � i - -�\ -� SEE NOTE #14 UWN _ (CN 4 CONC.' WALKA - - -- PROPOSED _ - - - c� A �\ (SIGNAL I i - - �- � / _ (A B) �" 24 ' - - -- __ __ __ _- _ - ----- - - - - -- 2 # 4-1-0 GND, 1 C 5 T£NTjOM '. h I - ' - - -- 1 t= /4,,C - - _ 2,r #4, 2, #6, 1 - #8 GND, / - a 4' C -- ONC. WALK Lu T a � I ` � r II tic V , DETENTION BASIN "C" 0 BE RELOCATED r . L 7 ca I � TO BE RELOCATED / A! 0 EXISTING z / �-d SIGNAL 624.92' S 88 40 41 W % LLJ I i i i � z LUMINAIRE WITH (1) 1000 WATT LAMP AND TYPE 5 OPTICS, BALLAST VOLTAGE: 480 VOLTS. HOUSING COLOR: WHITE PAINT, POLE: 24' -0" WITH 4" O.D. X 6" TENON, NOTE 13. WIDELITE #SLS- 8585 -DLMW- 480 -MOD o rn (616)- 459 -8327 FOR NATIONAL ACCOUNT PRICING. SB Li CUTOFF TYPE LUMINAIRE WITH HORIZONTAL LAMP, AND o Ir co y VOLTS. HOUSING COLOR: WHITE PAINT. POLE: 27' -6 ", NOTE 13 WIDELITE #XLS- 1000 -2 -480 -S -WHITE LITHONIA #KAS31000S -R4- 480- SP12 -DWH Z MCGRAW #GLA91225 -FT WHITE 0 OL #125- 29 -F -1- 480- 1000HPS WHITE 0 400 WATT, HIGH PRESSURE SODIUM, SIDE MOUNTED, 0 TYPE 3 OPTICS. BALLAST VOLTAGE: 480 VOLTS. HOUSING z COLOR: WHITE PAINT. POLE: 27' -6 ", NOTE 13 000 Q a MCGRAW #CS7262(DES.30) -480 WHITE EMCO #PAED- 3H -40OS -480 WHITE W W 1000 WATT METAL HALIDE, SIDE MOUNTING, (2) FIXTURES PER � o wM _ VOLTAGE: 480 VOLTS. HOUSING COLOR: WHITE PAINT. POLE: > w > W C) Lo J o0 L N � � z Q_ ORIENTED TOWARD PARKING LOT, SF Q N f� w Q I - Z o w z Lj Q a' o Q i Uy 0 a m O Of o Lij o- m w W 0 0 0 0 a 0 w w° U 0 0 0 0 0 w w w c 0 cn cn rY) Go 0; y J Q N r � d C-4 • • I �- ------- Z A -= 1 2- #4, 2-0, 1- #8 GN , 1 1/4 C SA ,/ SYMBOL DESCRIPTION o xQ ~ SA SA (AB) (BC) 37 / / ,�/ - ❑�❑ z I SE (g) 17 SA - - ` Q 21 (AB) A(BC ,' ;% ,� ��'` SA (AB) TWIN MOUNT LIGHT FIXTURE GRADE � T z- INDICATES PHASE EARTH / DENOTES FIXTURE TYPE N i / -- BACKFILL I I ' W Z I' � j � %� SC (Age SIDE MOUNT LIGHT FIXTURE RED OR YELLOW Q'✓ INDICATES PHASE WARNING TAPEI_ 2-#6, 1-#10 CND, 1 "C DENOTES FIXTURE TYPE - p -\ -2 # 6 1N 10 GND,1 "C / 3 j so DECORATIVE ENTRANCE LIGHT Z I ( �/ �;� / SA (&B POST MOUNT LIGHT FIXTURE. 14 22 28 32 , ,�� INDICATES PHASE W 18 " SA DENOTES FIXTURE TYPE 5 r✓ w O q BC DE 0 ES U E E - .•. S SA(BC) (AB) (AB) i I 2 EMPTY SF rp� F9 L I �C) / � r C � ( ) CONDUIT CONCEALED OR BURIED .. • PV T 4 SEE E C � CO N DU IT C APP ED . OF 35 � tu 4 SCHEDULE .. � I 1 I I ( \_ _ / 0 CONDUIT TURNING UP 40 PVC �� �i�i 2,#6, 1-#10 GND 1"C x L I I I ut 1-#10 I C)' 16 \ CO N R T E SF (� POLE NUMBE R ENCASEMENT - 2� # CND, 1 "C , � % co 2-#4, 2^, #6, 1 N #8 GND, 1 1 /4 "C 33 ,l BLDG. SETBACK � 19 SA(BC) I I I �� C F SC (BC) -_� _ '� �' EN ( �- T o Iry ON B » _'-� 2 4 EMPTY 23 � I � (AB) _�� v q v � TO BE RELOCATED ASSN A„ SEE NOTE 4 / `� � � i - -�\ -� SEE NOTE #14 UWN _ (CN 4 CONC.' WALKA - - -- PROPOSED _ - - - c� A �\ (SIGNAL I i - - �- � / _ (A B) �" 24 ' - - -- __ __ __ _- _ - ----- - - - - -- 2 # 4-1-0 GND, 1 C 5 T£NTjOM '. h I - ' - - -- 1 t= /4,,C - - _ 2,r #4, 2, #6, 1 - #8 GND, / - a 4' C -- ONC. WALK Lu T a � I ` � r II tic V , DETENTION BASIN "C" 0 BE RELOCATED r . L 7 ca I � TO BE RELOCATED / A! 0 EXISTING z / �-d SIGNAL 624.92' S 88 40 41 W % LLJ M i i SA � z LUMINAIRE WITH (1) 1000 WATT LAMP AND TYPE 5 OPTICS, BALLAST VOLTAGE: 480 VOLTS. HOUSING COLOR: WHITE PAINT, POLE: 24' -0" WITH 4" O.D. X 6" TENON, NOTE 13. WIDELITE #SLS- 8585 -DLMW- 480 -MOD o rn (616)- 459 -8327 FOR NATIONAL ACCOUNT PRICING. SB 1000 WATT, HIGH PRESSURE SODIUM, SIDE MOUNTED CUTOFF TYPE LUMINAIRE WITH HORIZONTAL LAMP, AND o Ir co y VOLTS. HOUSING COLOR: WHITE PAINT. POLE: 27' -6 ", NOTE 13 WIDELITE #XLS- 1000 -2 -480 -S -WHITE LITHONIA #KAS31000S -R4- 480- SP12 -DWH Z MCGRAW #GLA91225 -FT WHITE 0 OL #125- 29 -F -1- 480- 1000HPS WHITE 0 400 WATT, HIGH PRESSURE SODIUM, SIDE MOUNTED, 0 TYPE 3 OPTICS. BALLAST VOLTAGE: 480 VOLTS. HOUSING z COLOR: WHITE PAINT. POLE: 27' -6 ", NOTE 13 000 Q a MCGRAW #CS7262(DES.30) -480 WHITE EMCO #PAED- 3H -40OS -480 WHITE OL #125 -23- III -1- 480 -40HPS WHITE SD 1000 WATT METAL HALIDE, SIDE MOUNTING, (2) FIXTURES PER � o wM _ VOLTAGE: 480 VOLTS. HOUSING COLOR: WHITE PAINT. POLE: O 26' -0" WITH 4" O.D.x7" TENON AND SPB14DM2180 -W POLE w Lo J o0 L N (616)- 459 -8327 FOR NATIONAL ACCOUNT PRICING, SE SAME AS FIXTURE TYPE SA EXCEPT ASYMMETRIC DISTRIBUTION Q_ ORIENTED TOWARD PARKING LOT, SF Q N f� Q I - lL r U O o Q i N O Of o Lij 0 a 0 w w° U 0 0 0 0 0 c 0 rY) y J C-4 • • �- ------- - - - - A -= 1 2- #4, 2-0, 1- #8 GN , 1 1/4 C SA ,/ SYMBOL DESCRIPTION o xQ ~ SA SA (AB) (BC) 37 / / ,�/ - ❑�❑ z I SE (g) 17 SA - - ` Q 21 (AB) A(BC ,' ;% ,� ��'` SA (AB) TWIN MOUNT LIGHT FIXTURE GRADE � T z- INDICATES PHASE EARTH / DENOTES FIXTURE TYPE N i / -- BACKFILL I I ' W Z I' � j � %� SC (Age SIDE MOUNT LIGHT FIXTURE RED OR YELLOW Q'✓ INDICATES PHASE WARNING TAPEI_ 2-#6, 1-#10 CND, 1 "C DENOTES FIXTURE TYPE - p -\ -2 # 6 1N 10 GND,1 "C / 3 j so DECORATIVE ENTRANCE LIGHT Z I ( �/ �;� / SA (&B POST MOUNT LIGHT FIXTURE. 14 22 28 32 , ,�� INDICATES PHASE W 18 " SA DENOTES FIXTURE TYPE 5 r✓ w O q BC DE 0 ES U E E - .•. S SA(BC) (AB) (AB) i I 2 EMPTY SF rp� F9 L I �C) / � r C � ( ) CONDUIT CONCEALED OR BURIED .. • PV T 4 SEE E C � CO N DU IT C APP ED . OF 35 � tu 4 SCHEDULE .. � I 1 I I ( \_ _ / 0 CONDUIT TURNING UP 40 PVC �� �i�i 2,#6, 1-#10 GND 1"C x L I I I ut 1-#10 I C)' 16 \ CO N R T E SF (� POLE NUMBE R ENCASEMENT - 2� # CND, 1 "C , � % co 2-#4, 2^, #6, 1 N #8 GND, 1 1 /4 "C 33 ,l BLDG. SETBACK � 19 SA(BC) I I I �� C F SC (BC) -_� _ '� �' EN ( �- T o Iry ON B » _'-� 2 4 EMPTY 23 � I � (AB) _�� v q v � TO BE RELOCATED ASSN A„ SEE NOTE 4 / `� � � i - -�\ -� SEE NOTE #14 UWN _ (CN 4 CONC.' WALKA - - -- PROPOSED _ - - - c� A �\ (SIGNAL I i - - �- � / _ (A B) �" 24 ' - - -- __ __ __ _- _ - ----- - - - - -- 2 # 4-1-0 GND, 1 C 5 T£NTjOM '. h I - ' - - -- 1 t= /4,,C - - _ 2,r #4, 2, #6, 1 - #8 GND, / - a 4' C -- ONC. WALK Lu T a � I ` � r II tic V , DETENTION BASIN "C" 0 BE RELOCATED r . L 7 ca I � TO BE RELOCATED / A! 0 EXISTING z / �-d SIGNAL 624.92' S 88 40 41 W % LLJ // TYPE DESCRIPTION SA � z LUMINAIRE WITH (1) 1000 WATT LAMP AND TYPE 5 OPTICS, BALLAST VOLTAGE: 480 VOLTS. HOUSING COLOR: WHITE PAINT, POLE: 24' -0" WITH 4" O.D. X 6" TENON, NOTE 13. WIDELITE #SLS- 8585 -DLMW- 480 -MOD CONTACT MARVIN VENEKLASEN, ACKERMAN ELECTRICAL SUPPLY CO. (616)- 459 -8327 FOR NATIONAL ACCOUNT PRICING. SB 1000 WATT, HIGH PRESSURE SODIUM, SIDE MOUNTED CUTOFF TYPE LUMINAIRE WITH HORIZONTAL LAMP, AND TYPE 4 FORWARD THROW OPTICS. BALLAST VOLTAGE: 480 Q VOLTS. HOUSING COLOR: WHITE PAINT. POLE: 27' -6 ", NOTE 13 WIDELITE #XLS- 1000 -2 -480 -S -WHITE LITHONIA #KAS31000S -R4- 480- SP12 -DWH MCGRAW #GLA91225 -FT WHITE 0 OL #125- 29 -F -1- 480- 1000HPS WHITE 0 400 WATT, HIGH PRESSURE SODIUM, SIDE MOUNTED, CUTOFF TYPE LUMINAIRE WITH HORIZONTAL LAMP, AND TYPE 3 OPTICS. BALLAST VOLTAGE: 480 VOLTS. HOUSING z COLOR: WHITE PAINT. POLE: 27' -6 ", NOTE 13 000 Q - MCGRAW #CS7262(DES.30) -480 WHITE EMCO #PAED- 3H -40OS -480 WHITE OL #125 -23- III -1- 480 -40HPS WHITE SD 1000 WATT METAL HALIDE, SIDE MOUNTING, (2) FIXTURES PER O POLE AT 180' APART, CUTOFF TYPE LUMINAIRE WITH (1) 1000 wM _ VOLTAGE: 480 VOLTS. HOUSING COLOR: WHITE PAINT. POLE: O 26' -0" WITH 4" O.D.x7" TENON AND SPB14DM2180 -W POLE O J o0 L N (616)- 459 -8327 FOR NATIONAL ACCOUNT PRICING, SE SAME AS FIXTURE TYPE SA EXCEPT ASYMMETRIC DISTRIBUTION ORIENTED TOWARD PARKING LOT, SF Q N f� Q I - o N O Q CO 1 2- #4, 2-0, 1- #8 GN , 1 1/4 C SA ,/ SYMBOL DESCRIPTION o xQ ~ SA SA (AB) (BC) 37 / / ,�/ - ❑�❑ z I SE (g) 17 SA - - ` Q 21 (AB) A(BC ,' ;% ,� ��'` SA (AB) TWIN MOUNT LIGHT FIXTURE GRADE � T z- INDICATES PHASE EARTH / DENOTES FIXTURE TYPE N i / -- BACKFILL I I ' W Z I' � j � %� SC (Age SIDE MOUNT LIGHT FIXTURE RED OR YELLOW Q'✓ INDICATES PHASE WARNING TAPEI_ 2-#6, 1-#10 CND, 1 "C DENOTES FIXTURE TYPE - p -\ -2 # 6 1N 10 GND,1 "C / 3 j so DECORATIVE ENTRANCE LIGHT Z I ( �/ �;� / SA (&B POST MOUNT LIGHT FIXTURE. 14 22 28 32 , ,�� INDICATES PHASE W 18 " SA DENOTES FIXTURE TYPE 5 r✓ w O q BC DE 0 ES U E E - .•. S SA(BC) (AB) (AB) i I 2 EMPTY SF rp� F9 L I �C) / � r C � ( ) CONDUIT CONCEALED OR BURIED .. • PV T 4 SEE E C � CO N DU IT C APP ED . OF 35 � tu 4 SCHEDULE .. � I 1 I I ( \_ _ / 0 CONDUIT TURNING UP 40 PVC �� �i�i 2,#6, 1-#10 GND 1"C x L I I I ut 1-#10 I C)' 16 \ CO N R T E SF (� POLE NUMBE R ENCASEMENT - 2� # CND, 1 "C , � % co 2-#4, 2^, #6, 1 N #8 GND, 1 1 /4 "C 33 ,l BLDG. SETBACK � 19 SA(BC) I I I �� C F SC (BC) -_� _ '� �' EN ( �- T o Iry ON B » _'-� 2 4 EMPTY 23 � I � (AB) _�� v q v � TO BE RELOCATED ASSN A„ SEE NOTE 4 / `� � � i - -�\ -� SEE NOTE #14 UWN _ (CN 4 CONC.' WALKA - - -- PROPOSED _ - - - c� A �\ (SIGNAL I i - - �- � / _ (A B) �" 24 ' - - -- __ __ __ _- _ - ----- - - - - -- 2 # 4-1-0 GND, 1 C 5 T£NTjOM '. h I - ' - - -- 1 t= /4,,C - - _ 2,r #4, 2, #6, 1 - #8 GND, / - a 4' C -- ONC. WALK Lu T a � I ` � r II tic V , DETENTION BASIN "C" 0 BE RELOCATED r . L 7 ca I � TO BE RELOCATED / A! 0 EXISTING z / �-d SIGNAL 624.92' S 88 40 41 W % SITE LIGHTING FIXTURE SCHEDULE // TYPE DESCRIPTION SA HIGH PRESSURE SODIUM, POST TOP, CUTOFF TYPE LUMINAIRE WITH (1) 1000 WATT LAMP AND TYPE 5 OPTICS, BALLAST VOLTAGE: 480 VOLTS. HOUSING COLOR: WHITE PAINT, POLE: 24' -0" WITH 4" O.D. X 6" TENON, NOTE 13. WIDELITE #SLS- 8585 -DLMW- 480 -MOD CONTACT MARVIN VENEKLASEN, ACKERMAN ELECTRICAL SUPPLY CO. (616)- 459 -8327 FOR NATIONAL ACCOUNT PRICING. SB 1000 WATT, HIGH PRESSURE SODIUM, SIDE MOUNTED CUTOFF TYPE LUMINAIRE WITH HORIZONTAL LAMP, AND TYPE 4 FORWARD THROW OPTICS. BALLAST VOLTAGE: 480 VOLTS. HOUSING COLOR: WHITE PAINT. POLE: 27' -6 ", NOTE 13 WIDELITE #XLS- 1000 -2 -480 -S -WHITE LITHONIA #KAS31000S -R4- 480- SP12 -DWH MCGRAW #GLA91225 -FT WHITE EMCO #PAED- F -10OS -480 WHITE OL #125- 29 -F -1- 480- 1000HPS WHITE SC 400 WATT, HIGH PRESSURE SODIUM, SIDE MOUNTED, CUTOFF TYPE LUMINAIRE WITH HORIZONTAL LAMP, AND TYPE 3 OPTICS. BALLAST VOLTAGE: 480 VOLTS. HOUSING COLOR: WHITE PAINT. POLE: 27' -6 ", NOTE 13 WIDELITE #XLS - 400 -480 -S -WHITE LITHONIA #KAS240OS -R3- 480- SP12 -DMB MCGRAW #CS7262(DES.30) -480 WHITE EMCO #PAED- 3H -40OS -480 WHITE OL #125 -23- III -1- 480 -40HPS WHITE SD 1000 WATT METAL HALIDE, SIDE MOUNTING, (2) FIXTURES PER POLE AT 180' APART, CUTOFF TYPE LUMINAIRE WITH (1) 1000 WATT LAMP PER FIXTURE AND TYPE 5 OPTICS. BALLAST VOLTAGE: 480 VOLTS. HOUSING COLOR: WHITE PAINT. POLE: 26' -0" WITH 4" O.D.x7" TENON AND SPB14DM2180 -W POLE MOUNT ADAPTER BRACKET, NOTE #13 WIDELITE *SLM- 10585 -DLWM- 480 -MOD CONTACT MARVIN VENEKLASEN, ACKERMAN ELECTRICAL SUPPLY CO. (616)- 459 -8327 FOR NATIONAL ACCOUNT PRICING, SE SAME AS FIXTURE TYPE SA EXCEPT ASYMMETRIC DISTRIBUTION ORIENTED TOWARD PARKING LOT, SF 100 WATT HIGH PRESSURE SODIUM_ ONE LAMP PER FIXTURE. BEGA CATALOG #9365S. POLE: 24'^ -0 ", POLE AND FIXTURE TO BE PAINTED WHITE, Q NOTES: Q Q 1. DIMENSIONS SHOWN ARE MINIMUMS. W p 2. USE FORMS TO HOLD CONDUITS IN PLACE M _Z AS SHOWN TO ENSURE COMPLETE ENCASEMENT. O Q W Z 3. FOR RIGID GALVANIZED STEEL CONDUIT, TOP OF m C' CONDUIT SHALL BE 36" BELOW FINISHED GRADE. T z< Z ELECTRICAL SERVICE CONDUIT 0 a. N TS � Z Q j O � �Z Q GENERAL NOTES O _ o o 1. UNLESS NOTED, WIRING SHALL BE THWN #6 AWG WITH #10 AWG GROUNDING I'm Z _j CONDUCTOR_ ALL CONDUIT SHALL BE SCHEDULE 40 PVC OF A TYPE V 0c) SUITABLE FOR UNDERGROUND USE WITHOUT CONCRETE ENCASEMENT, 1" MINIMUM_ Q V 2. CONDUIT SHALL BE BURIED MINIMUM 3' -0" BELOW FINISHED SUBGRADE. Z = W I COORDINATE POLE LOCATIONS WITH PAVING, CURBS AND UTILITIES. � J W W Ow 4. CAP ENDS OF EMPTY CONDUIT, PROVIDE PULL WIRE, MEASURED TAPE TYPE F- PULL PULL STRING INDICATING EXACT LENGTH, AND STAKE LOCATION WITH A 12 "x12 "x2,, Q uj PRECAST CONCRETE BLOCK WITH "ELECTRIC" EMBOSSED ON THE TOP SIDE. W Z N V 5. PRIMARY ELECTRICAL SERVICE CONDUITS, WITH PULL WIRE, SHALL BE RIGID 0 Z co GALVANIZED STEEL WITH LONG SWEEP ELBOWS, OR PVC ENCASED IN CONCRETE WITH O 0 GALVANIZED STEEL LONG SWEEP ELBOWS. SEE ELECTRICAL SERVICE DETAIL FOR BURIAL DEPTH, REFER ALSO TO "UTILITY COORDINATION NOTE ", AND STANDARD DETAIL. V 1- Lu 6. TERMINATE PARKING LOT LIGHTING CONDUITS WITH PULL WIRE AT POINT NOTED. (Ld U 7. STUB UP CONDUITS 6" ABOVE FINISHED FLOOR ELEVATION ALONG WALL, SEE BUILDING ELECTRICAL DRAWINGS FOR EXACT ENTRY LOCATION_ 55 8. FOR LIGHT POLES ALONG DRIVEWAYS LOCATE CENTER LINE OF BASE 5' -0" FROM BACK OF CURB. (SEE COORDINATE CHART) 9. SUBSCRIPTS ON FIXTURE SYMBOLS ARE PHASE DESIGNATIONS AND REFER TO 480V, 10, 2 -WIRE CIRCUITS, SEE LIGHTING CONTROL DIAGRAM ON STORE ELECTRICAL DRAWINGS FOR TERMINATION. 10, PYLON SIGNS ARE TO UTILIZE ONE 480 V. SINGLE PHASE CIRCUIT. REFER TO LIGHTING CONTROL DIAGRAM ON STORE ELECTRICAL DRAWINGS FOR TERMINATION. 11_ CONTRACTOR SHALL INSTALL (2) -4" SCHEDULE 40 PVC CONDUITS WITH #8 PULL WIRE AND MEASURED TAPE TYPE STRING INDICATING EXACT PULL LENGTH FOR TELEPHONE SERVICE. REFER ALSO TO UTILITY COORDINATION NOTE, 12. ROUTE CONDUITS TO AVOID PLANTINGS, COORDINATE WITH LANDSCAPE DRAWINGS. 13_ POLES SHALL BE ROUND TAPERED WHITE FIBERGLASS. FILE NO. POLES SHALL BE PRICED PER NATIONAL ACCOUNT, 14. STUB UP & CONNECT TO SIGN DISCONNECT SWITCH PROVIDED WITH SIGN F ON SIGN SUPPORT POST. NOTE: LIGHT FIXTURE MOUNTING HEIGHT SHALL NOT EXCEED 30' -0" 0 50 100 150 200 ; �<; SCALE: 1 " =50' z b1 -� w C10 GRAPHIC SCALE IN FEET V)