Loading...
HomeMy WebLinkAbout0495.93.60C E 0 t 0 >\ 0 N / rn CV 7 -LIGHT POLE -4 - - - - - - - - --- 407 ;j I (TYP.)II /MAIN -SASH CONVEYOR j STAND 7 i' III � I I -- — - — - — - — — -- - 7 1/4" 4" CASH STAND FINISHED FLOOR BASE LINE (TILE LINE) LIGHT POLE BRACKETS DETAIL NOT USED NOT USED 7 NO SCALE 6 5 3/4" ELECTRO- PLATED ® ° GALV. HINGED EXTENSION -� SPLIT CLAMP WITH 3/8" i BOLT CONNECTION. BEE -LINE #B3198H -3/4 OR EQUAL COMPLYING 11/2'' 10" NOTE: WITH MANUFACTURERS I FINISH TO BE CHROME SOCIETY SP -69 TYPE 12. 3/4 PLATED HIGH GLOSS 3/8'' 3/8" -16x6" ROUND HEAD FULLY THREADED MACHINE SCREW I I I DRILL FOR I MACHINE HOLE W &DPROV DE 6 -1/4" POLE T.�3/8 " -16 N.C. NUT. WELD ! TAND -0 PLATE. 8 /2" BAR ; 66" i !11 MB NUT 1 1/4" H.R.S. BAR STOCK. (2) BRACKETS REQUIRED 1 ! ! FOR EACH LIGHT LOCATION, 148E i PAINT BLACK. I i I 9/32'' I I DIA. HOLES ! ! ! . 3/4" RIGID STEEL CONDUIT I ! + I ° CHROME PLATED AND 6x6" ROUND i =LILLY THREADED ! THREADED ON BOTH ENDS FOR BUSHINGS BY E.C. mr �nuJE SCREW TREAT GALVANIZED CONDUIT A6 LIGHT POLE DETAILS I BEFORE CHROME PLATING. E407 NO SCALE NOTE: PRIOR TO FLOOR POUR, INSTALLTRENCH C6 TRENCH EXIT COVER COVER W/ TILE TRIM DOWN FLUSH W/ COVER. I 407 PRIOR TO TILE INSTALLATION, INVERT TRIM SO - _ _ _ _ _ _ _ _ IT IS RAISED ABOVE COVER. - - - - - - - - - - ELEVATION TO TOP OF ROUGH LEVELING SLAB TRENCH PER MANUF. RECOMMENDATIONS. FOUR COMPARTMENT TRENCH ALUMINUM _ _ _ _ _ _ _ _ _ _ _ _ HEADER SYSTEM. SEE SPECS. TILE TRIM (TYP) Y - SEE NOTE BELOW. TRENCH FINISH FLOOR 12" COVER WIDTH FLINE (TILE LINE) COMP. #2 — H/ - -- - D6 X407 1 1 2 I 3 1 4 I TREN -,-1 L �-LEVELING _ - - -- COMP. #3 - -- - -- �- - - - - - - - - - SCREW - i COORDINATE ELEVATION L E.C. SHALL GROUT TRENCH _ T _ E . . SHALL PROVIDE 3/4' WITH CONCRETE UNDER TRENCH COMP. � E A LE IN CO E4 $M COMPARTMENT *4 CONTRACTOR 0 IL I' 1 --- 1--- C6 _ - - - - -- ENCH COMPARTMENTS SHALL BE UTILIZED AS FOLLOWS: COM- TRENCH ,RTMENT #1 FOR CHECKOUT TELEPHONE CABLES, COMPARTMENT FACTORY PRE - DRILLED ' � COVER FOR CASH REGISTER STANDBY POWER WIRING; COMPART- 3/4" HOLE (TYP. FOR 4) (TYPICAL) NT # 3 FOR ST ANDARD POWER WIRING: COMPARTMENT #4 I 1R CASH REGISTER CONTROLLER CABLES AND CATALINA 407 'INTER CABLES. II i B6 CHE =CKOUT TRENCH DETAIL B5 TRENCH EXIT COVER DETAIL NOTE PROVIDE SMALLER DIAMI -TER GROMMET FOR TELEPHONE CABLE. 3/4" RIGID CONDUIT - COUPLING PROVIDED BY E.C. 3/4" STRAIN RELIEF CORD CONNECTOR. ''PYLE NATIONAL ' (OR EQUAL) DO NOT OVERTIGHTEN AND CRUSH CABLES. TRENCH DUCT EXIT COVER 3/4" INSULATED CHASE NIPPLE "RACO" (OR EQUAL) FURN. AND INSTALLED BY E.C. __NCH CABLE EXIT DETAIL C'EAI TITC CI CV >, PROVIDED TRENCH POWER EXIT DETAIL +07 NOT USED 6 T / �I r NOTE AL' FU SU LIG 2. BU TO NCR MAGNETIC STRIP READER NOTE 11 SCANNER /SCALE NOTE 13 4 3 2 '17053' TERMINAL RECEPTACLE CHANGE MAKER RECEPTACLE LABEL OUTLET - " TERMINAL' LABEL OUTLET - ''CHANGER'' - CATALINA PRINTER RECEPTACLE \, \ LABEL OUTLET: "PRINTER ". "NCR" SCANNER /SCALE SWITCHED RECEPT, QUAD PLEX. LABEL I V I CUTLET - "SCANNER/ SCALE'' I i i ! EXTRA SWITCHED OUTLET I i III r ! p u I ! Q i SCANNER BLOWER MOTOR �l I CONDUIT I j l 1 1 SCAN /SCALE SWITCH 115V AC CHECKSTAND FRAME TANDEM CHECKOUT 'ISOMETRIC °! AN NO SCALE (TYPICAL FOR 12 - SEE NOTE 9, 19 & 20) 5 4 CHECKLANE LIGHT FIXTURE. FURNISHED & INSTALLED BY E.C. SEE DETAIL C7/E406. TRIANGULAR CHECKLANE NUMBER INDICATOR FURNISHED & INSTALLED B) GRAPHICS CONTRACTOR TELEPHONE LOCATION NOTE 10. CHANGE MAKER BY N.C.R. AND 3- POSITION ROCKER SWITCH FURNISHED BY OWNER, INSTALLED BY E.C., NOTE 7. TE 3. SPEND �A LAY CATALINA PRINTEP POWER AND DATA CABL ..NOTE 27. -IONS T.O' CHANGE MAKER AND GISTLE BY N.C.R. REPRE'SENTATiVE. -CHANGE MAKER INTERFACE ii JUNCTION BOX' FURN. WITH i�— CONVEYOR,TO REMAIN �i -U 17 ALINA PRII TtR CABLE i� CO NNECTiQPdS BY OWNERS _REP . NOY 26. r i f ` U i NOTE 14 & 18 NOTE 15 & 18 I NOTE 22 & DETAIL C6/E407 NOTE 24 & DETAIL D6/E407 LIGHT POLE BRACKET NOTE 3 & DETAIL A7/E407. NOTE 16 & DETAIL D6/E407 3/4" ELBOW BY E.C. SEE DETAIL #B4/E406. ACCESS HOLE AT LOWER BACK OF CASH STAND NOTE 25 & DETAIL B4/E406 TELEPHONE CABLE BY TELEPHONE CONTR. ATTACH TO EXTERIOR OF LIGHT POLE WITH CABLE TIES. NOTE 23 & DETAIL C6/E407 • 1 NOTES: �J ELECTRICAL CONTRACTOR TO PROVIDE 120V. CONNECTION VIA FLEXIBLE CONDUi I FROM CONVEYOR MOTOR CIRCUIT TO POLE MOUNTED LIGHT FIXTURE THROUGH ROCKER SWITCH ON THE CONVEYOR. SEE NOTE 7 & DETAIL B4/E407. U2 WRAP ALL EXPOSED CABLES FROM CASH REGISTER TO CHECKOUT WITH "PANDUIT SPIRAL WRAP" (BLACK) OR EQUAL. E.C. TO FURNISH & INSTALL LIGHT POLE (WITH LIGHT FIXTURE) & BRACKETS ON CASH STANDS. MOUNT BRACKETS VERTICALLY (2 PER CASH STAND) ON INSIDE OF CASH STAND (SEE DETAIL A7/E407). LIGHT POLE SHALL BE MOUNTED TO THE BACK OF THE CASH STAND IN THE CORNER WHERE THE CASH STAND & THE MAIN CONVEYOR UNIT MEET. C PRE -WIRED CONVEYOR MOTOR JUNCTION BOX. ® ELEM CTRICAL CONTRACTOR TO PROVIDE 120V CONNECTION FRO STANDARD DISTRIBUTION PANEL TO CONVEYOR MOTOR JUNCTION BOX PREWIRED BY EQUIPMENT SUPPLIER. ROUTE WIRING VIA UNDERFLOOR TRENCH. CONVEYOR MOTOR "ON /OFF" SWITCH. O 3- POSITION ROCKER SWITCH FURNISHED BY OWNER, ! NSTALLED BY E.C. PROVIDE CONDUIT & WIRING AND CONNECT SWITCH TO OWNER FURNISHED, E.C. INSTALLED SOLID STATE FLASHER MOUNTED IN JUNCTION BOX LOCATED UNDER TRANSPORT. SEE DETAIL A3/E406. ® SCANNER CONTROL SWITCH. �9 THE ENTIRE CHECKLANE, INCLUDING CHECKWRITING STAND & BAGGING SHELF SHALL BE INSTALLED & LEVELED BY THE "STORE FIXTURE INSTALLER" NOT BY THE ELECTRICAL CON- TRACTOR. ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH THE FIXTURE INSTALLER. (TYPICAL FOR 12 CHECKL ANES). 10 TELEPHONE HANDSET BY OWNER, INSTALLED BY TELEPHONE CONTRACTOR. TELEPHONE CONTRACTOR SHALL PROVIDE MODULAR JACK AND MOUNT TO LIGHT POLE. TELEPHONE TO HAVE 6' COILED HANDSET. SEE DRAWING E402. CHECKWRITER STAND TO BE MOUNTED BY CHECKLANE INSTALLER. 12 CONVEYOR MOTOR ELECTRIC EYE. 13 PROVIDE 10' OF CONTROLLER CABLE COILED FOR CONNECTION TO REGISTER BY NCR REPRESENTATIVE. SEE ECR CABLE -AYOUT ON DRAWING E401. 114 CASH REGISTER AND COUPON PRINTER RECEPTACLE, i FURNISHED WITH CHECKOUT, WIRED BY E.C. 15 CHANGE MAKER /SCANNER SCALE RECEPTACLE, FURNISHED WITH CHECKOUT, WIRED BY E.C. 16 E.C. TO PROVIDE 3/4" CONDUIT STUB FROM TRENCH COM- PARTMENT #3 W/ 3/4" FLEX CONNECTOR & CONDUIT FROM STUB TO CHECKOUT FOR CONVEYOR STANDARD POWER & j 1 FLASHING LIGHT WIRING. 1� SCANNER BLOWER FAN. 18 E.C. TO PROVIDE 120V CONNECTION, IN FLEXIBLE CONDUIT, TO EACH OF TWO (2) "QUADPLEX" RECEPTACLES. RECEPTACLES TO BE ON CIRCUIT FROM STAND BY DISTRIBUTION PANEL. SEE DRAWING E302 FOR CIRCUITING. 1 19 SEE CHECKLANE WIRING DIAGRAM THIS SHEET. 20 ELECTRICAL CONTRACTOR SHALL COMPLETELY WIRE (1) CHECKOUT & OBTAIN ENGINEERS APPROVAL PRIOR TO PROCEEDING ON BALANCE OF CHECKOUTS. 21 CONVEYOR MOTOR INTERRUPTING FOOT PAD INSTALLED & CONNECTED BY EQUIPMENT SUPPLIER. 22 ELECTRICAL CONTRACTOR TO PROVIDE 3/4" CONDUIT STUB FROM TRENCH COMPARTMENT #1, PROVIDE STRAIN RELIEF CORD CONNECTOR ON END OF CONDUIT TO SECURE TELEPHONE CABLE FROM TRENCH. 23 ELECTRICAL CONTRACTOR TO PROVIDE (2) 3/4" CONDUIT i STUB FROM TRENCH COMPARTMENT -4, PROVIDE STRAIN RELIEF CORD CONNECTOR ON END OF CONDUIT TO SECURE NCR CONTROLLER CABLES FROM TRENCH. 24 E.C. TO PROVIDE 3/4" CONDUIT STUB FROM TRENCH COMPARTMENT #2 W/ 3/4" FLEX CONNECTOR & CONDUIT FROM STUB TO CHECKOUT FOR NCR POWER & STAND BY POWER. 25 E.C. SHALL PROVIDE "FLEX CONDUIT" TYPE CONNECTOR WHERE LIGHT FIXTURE FLEX CONDUIT EXITS BACK OF CASH STAND FOR RETAINING EXCESS FLEX CONDUIT IN CHECKOUT. "FLEX CONDUIT SHALL NOT DRAPE ON FLOOR!" 26 PROVIDE 10' LOOP OF CATALINA PRINTER CABLE IN MAIN CONVEYOR UNIT FOR FINAL CONNECTION BY COMMUNICATIONS CONTRACTOR. SEE CABLE LAYOUT ON DRAWING E401. 27 EXTEND (1) POWER CABLE TO RECEPTACLE BELOW TRANS- PORT (SEE NOTE 14 & DETAIL B4/E407). (1) DATA EXTENSION CABLE (BY MEIJER) ASSEMBLY WILL BE QUALITY CABLE, 7' -4" EXTENSION PRINTER CABLE. CABLE RUNS FROM TERMINAL STRIP BELOW TRANSPORT TO CONNECTOR ON BACK OF PRINTER. DESCRIPTION OF OPERATION OPERATOR TURNS ON MAIN CONVEYOR SWITCH. MAIN CONVEYOR .WILL RUN UNTIL PHOTO CONTROL IS BLOCKED, WHEN PHOTO CONTROL IS CLEARED, MAIN CONVEYOR WILL RUN 10OX OF THE TIME. LIGHT SWITCHES: THE ROCKER SWITCH HAS 3 POSITIONS "OFF" "ON" AND "FLASH ". MAIN CONVEYOR CAN BE OPERATED MANUALLY THROUGH THE MAIN CONVEYOR FOOT SWITCH. THE ABOVE ISOMETRIC PLAN FACILITATES THE UNDERFLOOR RACEWAY SYSTEM AT THE LOCATION OF THE "MULT -A -ZONE" TRENCH HEADER SYSTEM (OR EQUAL PER SPECS.). SEE DWG. E302 & E307. E.C. SHALL PROVIDE TWO (2) CONDUIT STUBS W/ FLEX CONDUIT AT EACH CHECKOUT FOR STANDARD POWER & ISOLATED GROUND POWER AND TWO (2) CONDUIT STUBS WITH STRAIN RELIEF CONNECTORS FOR CASH REGISTER CONTROLLER CABLE & ONE (1) CONDUIT STUB W /STRAIN RELIEF CONNECTOR FOR TELEPHONE CABLE. DETAIL KEY Al DETAIL NUMBER A101 SHEET WHERE DETAIL IS CUT OR SHOWN 3 2 1 i i +i I i m r ± i� i mj o1 LLj Iz Yid 3: W U+ Q w 0 12� U = ( 0 U a- I I ! ! I A WMooEMEELMELMIELM I I !i I i I 1 I . s� �..o U-) `• :w o •� O L0 x ....... I Co P Zo a I � N rn 0 z w J LL_ U) L 0 c W �--+ 4-1 U� �co i i ^ l W a) O� c • • • O O w 1`0 J 0) U- oo w ui z N O --D • • 0 Z w o O F— V • • O LL 0 Li 7) U) 0 • w Q 0 • 0 w V) w Q 0 Q U E-- Lli 0 Y U W U 0 Q r` 0 M LL S co n o6 lqr S N M n O N ' C W cc$ o U � C- 0 ui Y � 870 C • • s • is B C D E { 0 i Li I 0 0 C9 w Q z 10- � Li 0:� Q 0 Z w° �J �w w Q ® ® A • • • • • • • • • I � N rn 0 z w J LL_ U) L 0 c W �--+ 4-1 U� �co i i ^ l W a) O� c • • • O O w 1`0 J 0) U- oo w ui z N O --D • • 0 Z w o O F— V • • O LL 0 Li 7) U) 0 • w Q 0 • 0 w V) w Q 0 Q U E-- Lli 0 Y U W U 0 Q r` 0 M LL S co n o6 lqr S N M n O N ' C W cc$ o U � C- 0 ui Y � 870 C • • s • is B C D E { 0 i Li I