Loading...
HomeMy WebLinkAbout0495.93.63FA s 0 107 E 0 0 rn O 0 0 w i N_ 0 N rn A 7 4" n(TA(nm PnY TYPICAL E306, E501 4C 18G FIREWIRE TO SPLICE 7 BOX m I C 4C 18G FIREWIRE � BLK 6 0 5 If 0 0 , BLK 1 GRN TO SPLICE BOX I , 4C 22G WIRE DO NOT MOUNT SMOKE SHORT ON ALARM vl o RED DUPLEX OUTLET ABOVE CEILING P.I.V. SWITCH WIRING DELAY BETWEEN i 2" EMT STUBBED 5000 I. TO SPLICE BOX 120 VAC EM. CKT . F B DETECTOR ON BOTTOM OFI RED I AT CEILING W/ 11 I /-2C IN BACKROOM AREAS MOUNT CEILING JOIST. I RISER #3 BUSHING. j '1 a SMOKE DETECTOR n + PLUG IN TRANSFORMER RISER NC H m 120 VAC EM CKT. CEILING STEEL JOIST. 0 ! RISER #5 0 3/4" EMT REQUIRED I + F FIRE PUMP RUNNING 6 FINISHED OR DROP CEILING. F c\ �\ 1/2" EMT STUBBED OUT ABOVE IN OFFICE AREA MOUNT SMOKE o Ln CIN r- s ELECTRICAL ROOM SMOKE FINISHED CEILING W /BUSHING. DETECTOR ON FINISHED CEILING 0 c • • A. A • A B `,;tttttt1111�1���,'''4 IF IT EXISTS. I iw C w im ,�j,nLL0 sZa: :� 000 (�B6 SMOKE DETECTOR MOUNTING I B5 P.I.V. GARDRN CENTER WIRING E501 E502 NO SCALE + E502, E503 No SCALE 503 _CANOPY F.P. PANEL F F (TYPICAL) F 16 ZONE FURNISHED AND O OS &Y RISER #1 PANEL OS &Y RISER #2 BY - ,INSTALLED SPRY NKLER CONTR. OS &Y RISER #4 I C4 503J SPLICE BOX'. O qq OS &Y RISER #5 ' ; jDET. CHECK OS &Y'S COLD ' FIRE PUMP OS &Y'S 4" SQUARE BOX WITH WATER = I I SINGLE GANG PLASTER GROUND L_ RING. T G LOCATE NEAR - 0 BY -PASS OS &Y'S ROOM THERMOSTAT. MAIN P.I.V. FIRE PUMP TROUBLE ` o GENERATOR RUNNING I � I I � . I RTS I ROOM TEMPERATURE SWITCH 1 I ' A6 DATA RM. TEMPERATURE MONITORING PANEL A5 CABINET MOUNTING 4" n(TA(nm PnY TYPICAL E306, E501 4C 18G FIREWIRE TO SPLICE 7 BOX 12 AWG COLD WATER PIPE GROUND. o , + + +� ALL WIRING + TO GRAPHIC ;, 11 ALL WIRING TO MSB - -_� + ' ANNUNCIATOR 0 Q + PANEL - I AN -16 , FLUSH MOUNTED C6 CABINET MOUNTING E501/ NO SCALE m I C 4C 18G FIREWIRE � BLK NC 0 ❑ 45 • If 0 0 GRN BLK F B GRN TO SPLICE BOX I TO SPLICE BOX DO NOT MOUNT SMOKE SHORT ON ALARM NO o RED O.S. & Y AND P.I.V. SWITCH WIRING DELAY BETWEEN 4C 18G FIREWIRE GUEST SERVICES. 5000 FLOW AND SWITCH SWITCH WIRED N.O. SHORT ON ALARM. F B DETECTOR ON BOTTOM OFI RED #2 YEL I /-2C IN BACKROOM AREAS MOUNT CEILING JOIST. I RISER #3 YEL CONTROL a SMOKE DETECTOR ON TOP OF RISER NC H m B CEILING STEEL JOIST. 0 WATERFLOW RISER #5 0 4" OCTAGON BOX TYPICAL F. F FIRE PUMP RUNNING 6 FINISHED OR DROP CEILING. F c\ IN OFFICE AREA MOUNT SMOKE o Ln CIN r- s ELECTRICAL ROOM SMOKE DETECTOR DETECTOR ON FINISHED CEILING 0 c • • A. A • A B `,;tttttt1111�1���,'''4 IF IT EXISTS. I iw C w im ,�j,nLL0 sZa: :� 000 (�B6 SMOKE DETECTOR MOUNTING I B5 P.I.V. AND O.S. &Y WIRING E501 E502 NO SCALE E501, E502, E503 No SCALE 12 AWG COLD WATER PIPE GROUND. o , + + +� ALL WIRING + TO GRAPHIC ;, 11 ALL WIRING TO MSB - -_� + ' ANNUNCIATOR 0 Q + PANEL - I AN -16 , FLUSH MOUNTED C6 CABINET MOUNTING E501/ NO SCALE PARALLEL WITH OTHER SWITCHES FOR BELL. C5 WATER FLOW SWITCH WIRING E501 E502, E503 No SCALE 4 3 12 AWG COLD WATER 12 AWG COLD WATER PIPE GROUND. PIPE GROUND I I i I I I 120 VAC EM CIRCUIT 5 - 2" EMT STUBBED AT I I REQUIRED. I CEILING W.TH BUSHINGS. 110V 11 ! i I 16" MAX. III I I I 1 1 1 1 ,I I I II II I I I I 1 1 1 1 1 1 II II I I I ! i I I I I II A I I II co , I , GROUND LUG I ' I I I w ' N I w 2" EMT I cn I N 1 Iw L_ ANG -16 NOTIFIER 5000 O LL_ o SERVICE DESK O FIRE CONTROL O i = Q M _ REMOTE ANNUNCIATOR i in Q I CO Ln ( I I j CONNECT TO POWER SUPPLY I i 24.25'' 24.25 _ " 22.88" HOLE SIZE 22.88" HOLE SIZE BOXES ARE 5.0" DEEP, FLUSH OAK TRIM EXACT LOCATION BY MEIJER 134 GUEST SERVICES CABINET MOUNTING E302, E501 12 AWG COLD WATER PIPE GROUND. 2" EMT STUBBED 2 -120 VAC EM CIRCUIT AT CEILING WITH DUPLEX OUTLETS REQUIRED. ®�� 1- 2 -2" EMT STUBBED BUSHING AT CEILING W /BUSHING RTS LOCATED INSIDE METER ROOM NOT AT ❑ ° ❑ WATERFMOWT� WITCHES. ! S I PLICE BOX #2 O + ' I RTS I 3" O.C. MIN. (SECURITY) I I-1/2" EMT 4" X 4" X 5'-0" WIREWAY ROMEX CONNECTOR GROUND LUG 1 1/2" EMT w Q 16 ZONE SPLICE BOX #3 O SUPERVISORY ANNUNCIATOR 1 1/2" EMT TO RISER PANEL OS &Y VALVES (FIRE ALARM) C4 METER ROOM CABINET MOUNTING E502 m NC BLK 4C 18G FIREWIRE � TO SPLICE BOX NC 0 ❑ 45 • BLK GRN BLK F B WATERFLOW TO SPLICE BOX I TO SPLICE BOX SWITCH WIRED N.O. SHORT ON ALARM NO o O SPLICE 45 TO 60 SECOND DELAY BETWEEN 4C 18G FIREWIRE GUEST SERVICES. 5000 FLOW AND SWITCH ACTIVATION. BOX * 3 F B RED RED #2 YEL I /-2C YEL, 16C w C I RISER #3 PARALLEL WITH OTHER SWITCHES FOR BELL. C5 WATER FLOW SWITCH WIRING E501 E502, E503 No SCALE 4 3 12 AWG COLD WATER 12 AWG COLD WATER PIPE GROUND. PIPE GROUND I I i I I I 120 VAC EM CIRCUIT 5 - 2" EMT STUBBED AT I I REQUIRED. I CEILING W.TH BUSHINGS. 110V 11 ! i I 16" MAX. III I I I 1 1 1 1 ,I I I II II I I I I 1 1 1 1 1 1 II II I I I ! i I I I I II A I I II co , I , GROUND LUG I ' I I I w ' N I w 2" EMT I cn I N 1 Iw L_ ANG -16 NOTIFIER 5000 O LL_ o SERVICE DESK O FIRE CONTROL O i = Q M _ REMOTE ANNUNCIATOR i in Q I CO Ln ( I I j CONNECT TO POWER SUPPLY I i 24.25'' 24.25 _ " 22.88" HOLE SIZE 22.88" HOLE SIZE BOXES ARE 5.0" DEEP, FLUSH OAK TRIM EXACT LOCATION BY MEIJER 134 GUEST SERVICES CABINET MOUNTING E302, E501 12 AWG COLD WATER PIPE GROUND. 2" EMT STUBBED 2 -120 VAC EM CIRCUIT AT CEILING WITH DUPLEX OUTLETS REQUIRED. ®�� 1- 2 -2" EMT STUBBED BUSHING AT CEILING W /BUSHING RTS LOCATED INSIDE METER ROOM NOT AT ❑ ° ❑ WATERFMOWT� WITCHES. ! S I PLICE BOX #2 O + ' I RTS I 3" O.C. MIN. (SECURITY) I I-1/2" EMT 4" X 4" X 5'-0" WIREWAY ROMEX CONNECTOR GROUND LUG 1 1/2" EMT w Q 16 ZONE SPLICE BOX #3 O SUPERVISORY ANNUNCIATOR 1 1/2" EMT TO RISER PANEL OS &Y VALVES (FIRE ALARM) C4 METER ROOM CABINET MOUNTING E502 ROOM TEMPERATURE SENSOR WIRING E502 NO SCALE I EXISTING RTU CONTROL TRANSFORMER - - - - - TYPICAL WIRING FOR EACHR COF TOP UNIT. � + FU ROOF TOP LINE + i 48OV -10 120V -10 +- - - - TO RTU CONTROL VOLTAGE + 3.1 + + 2 __NOTE 7 Fu 1N NORMALLY OPEN CONTACTS HELD CLOSED + 1 A FU = +SR -1 CONTACTS OPEN ON ALARM CONDITION. + - I 12ov -1 + _ _ _ SQUARE "D" 8501 KP -12 RELAY W/8501 480V -1q NOTE TO RTU SAME WIRING AS SHOWN TO RTU SAME WIRING AS SHOWN TO RTU SAME WIRING AS SHOWN NR -51 BASE NOTE 4. ON "FIRST DETECTOR" NOTE 5 ON "FIRST DETECTOR" NOTE 5 ON "FIRST DETECTOR" NOTE 5 JEFFERSON 480/120 RELAY NORMALLY ENERGIZED AS SHOWN. 1 I' 'TRANSFORMER C. 4 - #14 NOTE 5 I ! A I I WIRING ABOVE DASHED LINE TO BE - - - TO PROVIDE. WIRED AT THE ROOF TOP UNIT. -- - - - - - - - - - - -- -- --- - - - - -- ------ - - - - -I - - - - - - -- ------- - - - - -- - - - - - - - - - - - - ' -L--------------- - ! i I 4` 22G WIRE ! TO GUEST SERVICES r `+ ANNUNC!A OR. ALI WIRING BELOW DASHED LINE ! Y BLU I i . , 4C 18G FIREWIRE TO BE WIRED AT THE DUCT ! �Iw it i I BLU BLU BLU BLU I I BLU B�U CtAnt�� n�T�rTnp BRN ~ J W � S RED m Q� 0 BLK RN RED m SET TEMPERATURE I BRN m � RED AT 45 DEGREES j Z Q ❑ 45 • BLK ! BLK F B WATERFLOW TO SPLICE BOX I TO SPLICE BOX •IO+o+AloO OR NOTIFIER 5000 o BLK SPLICE FIRE PANEL AT 2 4C 18G FIREWIRE GUEST SERVICES. 5000 GRN j BOX * 3 F B RED I #2 YEL I FIRE 1 � w C I RISER ROOM TEMPERATURE SENSOR WIRING E502 NO SCALE I EXISTING RTU CONTROL TRANSFORMER - - - - - TYPICAL WIRING FOR EACHR COF TOP UNIT. � + FU ROOF TOP LINE + i 48OV -10 120V -10 +- - - - TO RTU CONTROL VOLTAGE + 3.1 + + 2 __NOTE 7 Fu 1N NORMALLY OPEN CONTACTS HELD CLOSED + 1 A FU = +SR -1 CONTACTS OPEN ON ALARM CONDITION. + - I 12ov -1 + _ _ _ SQUARE "D" 8501 KP -12 RELAY W/8501 480V -1q NOTE TO RTU SAME WIRING AS SHOWN TO RTU SAME WIRING AS SHOWN TO RTU SAME WIRING AS SHOWN NR -51 BASE NOTE 4. ON "FIRST DETECTOR" NOTE 5 ON "FIRST DETECTOR" NOTE 5 ON "FIRST DETECTOR" NOTE 5 JEFFERSON 480/120 RELAY NORMALLY ENERGIZED AS SHOWN. 1 I' 'TRANSFORMER C. 4 - #14 NOTE 5 I ! A I I WIRING ABOVE DASHED LINE TO BE - - - TO PROVIDE. WIRED AT THE ROOF TOP UNIT. -- - - - - - - - - - - -- -- --- - - - - -- ------ - - - - -I - - - - - - -- ------- - - - - -- - - - - - - - - - - - - ' -L--------------- - ! i I 4` 22G WIRE ! TO GUEST SERVICES r `+ ANNUNC!A OR. ALI WIRING BELOW DASHED LINE ! Y BLU I i . , 4C 18G FIREWIRE TO BE WIRED AT THE DUCT ! �Iw it i I BLU BLU BLU BLU I I BLU B�U CtAnt�� n�T�rTnp BRN ~ J W � S RED m Q� 0 BLK RN RED m E502 BRN m � RED BLK Z Q C7 Z BLK :2 O BLK BRN RED m E502 BRN m � + RED BLK Z Q C7 Z BLK TO NOTIFIER 5000 m m FIRE PANEL AT GUEST SERVICES. I ' 1 1 2 3 4 5 6 7 8 q 1 0 111 1 2 1 3 i I 2 4 5 I 6 7 b q 1 0 1 1 1 2 1 3 1 2 3 4 5 6 7 b 9 10 11 12 13 1 1 2 3 4 5 6 7 8 9 1'01111 12 13 I I I; a i!I i 1 l I III `� �- I L ! I N I l j j i ffvO NOT CUT W3 i j FK-1 i TRANSFORMER K1 - - -iK2 --- +K2 - - -!K2 120/24 - - - -!K2 . T l �� �� i --- N O T E 3 D C B A ____ D C B A I - - -- D C B A D C B A NOTE W1 & W2 CONNECTIONS FENWAL DH -22 AIR FENWAL DH - -22 AIR FENWAL DH -22 AIR FENWAL DH -22 AIR DUCT DETECTOR HOUSING. DUCT DETECTOR HOUSING. DUCT DETECTOR HOUSING. DUCT DETECTOR HOUSING. LAST DETECTOR ON LOOP FIRST DETECTOR ON LOOP E7 DUCT DETECTOR & RTU SHUTDOWN ��01E502 No SCALE A • • 7 6 5 4 SMOKE DETECTORS SMOKE DETECTORS SMOKE DETECTORS SMOKE DETECTORS! i LAST SMOKE DET.ON LOOP I I l D4 SMOKE DETECTOR WIRING E501 E502 No SCALE NOTES: 1. K2 RELAY PROVIDED TO SHUT AIR HANDLER DOWN IN THE EVENT OF ALARM.CONTACTS RATED AT 1 AMP AT 120 VAC OR 2 AMPS AT 24 VDC RESISTIVE. 2. SEE SPECIFICATIONS FOR REQUIREMENTS FOR DETECTORS. 3. 120/24V TRANSFORMERS FOR DUCT DETECTORS FURNISHED WITH DETECTOR. 4. E.C. SHALL FURNISH AND INSTALL RELAY AND BASE INSIDE ROOF TOP UNIT CONTROL BOX AND CONNECT AS SHOWN. TYPICAL FOR ALL ROOF TOP UNITS. 5. FURNISH AND INSTALL 4 - #14 WITH %2" CONDUIT FROM DUCT DETECTOR FOR SHUTDOWN OF RTU AND POWER TO DUCT DETECTORS. 6. PROVIDE PRIMARY 114 AMP TIME DELAY FUSES. USE SAME 120V CIRCUIT THAT POWERS DUCT DETECTOR FOR SMOKE RELAY CONTROL. 7, CONNECT 48OV/120V TRANSFORMER TO LOAD SIDE OF RTU DISCONNECT. SEE SPEC, SECTION 16721 -2.02, E.5 FOR LABELING INFORMATION. ALL RELAYS ARE SHOWN IN NORMAL STANDBY CONDITION. K1 NORMALLY ENERGIZED UNDER POWER ON CONDITION. CONTACTS TRANSFER UPON REMOVAL OF DETECTOR FROM HOUSING OR FAILURE OF AC INPUT. K2 NORMALLY DE- ENERGIZED. TERMINALS 11 -13 TRANSFER UPON ALARM FOR AIR HANDLER SHUTDOWN. CONTACTS ARE RATED 1 AMP AT 120 VAC OR 2 AMP AT 24 VDC RESISTIVE. K2 GRAY PIGTAIL PROVIDE FOR MONITORING NORMALLY OPEN ALARM CONTACTS. SR1 NORMALLY ENERGIZED. ® e 3 4 RJ31X JA( F & S CON T INSTALLED. I Li LL Q 0 2 1 • 12 AWG COLD WATER GROUND B2 1 MONITOR ROOM CABINET LAYOUT E306,� E501 , All V All CI Cr TOIr'AI DnV Tv O,n Al I LuVI IJ..J. a I V ML V C WITH TAMPER SWITCH B5 WIRED BY E.C. 503 FIRE PROTECTION RISER DETAIL " EMT TO WAY. D THROUGH SING. ORMER VIDED. /2" ROMEX - ONNECTOR EMT H SPLICE F CANOPY RISER WATERFLOW H BOX #1 F B CANOPY RISER OS &Y P HI -LOW PRESSURE SWITCH F A5 �— GARDEN CENTER CANOPY IF r F.P. PANEL. 503 A5 NOTE: WIRE TO FIRE ALARM CONTACT. 503 120 VAC EM. CKT. WIRE TO TROUBLE CONTACT. B FIRE DOOR CLOSE RELAYS B CONVEYOR. SHUTDOWN RELAY F s s s s FIRE DOOR SMOKE DETECTORS (SEE PLANS FOR QUANITY) F m BAKERY HOOD ALARM CONTACT (B26A) F m DELI HOOD ALARM CONTACT (D26B) F T AMERICAN GRILL HOOD ALARM CONTACT (S26B #U F m CHINESE CAFE HOOD ALARM CONTACT (S26B #3) F m CHINESE CAFE HOOD ALARM CONTACT (S26B #2) F n n DATA TELEPHONE SMOKE DETECTORS F - Ts FRONT DUCT SMOKE DETECTOR (SEE PLANS FOR QUANTITY) F l s s s CENTER DUCT SMOKE DETECTOR (SEE PLANS FOR QUANTITY) s s s F s s s s s s s s REAR DUCT SMOKE DETECTOR (SEE PLANS FOR QUANTITY) T 5 T� T i T� T T� i (E2 FIRE SYSTEM ONE LINE DIAGRAM 'NE 503 • 2 1 P• • O O A a A I • mi �I m E502 o m � o+ o Z Q C7 Z Y w :2 O F B WATERFLOW RISER #1 •IO+o+AloO NOTIFIER o o SPLICE F B z 3 5000 H BOX * 3 F B WATERFLOW RISER #2 H FIRE o Q w C WATRFLOW RISER #3 CONTROL a B WATERFLOW RISER #4 H m B A o 0 WATERFLOW RISER #5 0 F FIRE PUMP RUNNING 6 F c\ o Ln CIN r- s ELECTRICAL ROOM SMOKE DETECTOR 0 c • • A. A • A B `,;tttttt1111�1���,'''4 U. iw C w im ,�j,nLL0 sZa: :� 000 , °•• SRO `\��• 4,,� 03RISER BELL hr /1111111 B4 C4 503 503 F F (TYPICAL) F 16 ZONE OS &Y RISER #1 PANEL OS &Y RISER #2 OS &Y RISER #3 OS &Y RISER #4 C4 503J qq OS &Y RISER #5 jDET. CHECK OS &Y'S COLD FIRE PUMP OS &Y'S WATER = GROUND TYPICAL BY -PASS OS &Y'S MAIN P.I.V. FIRE PUMP TROUBLE GENERATOR RUNNING RTS I ROOM TEMPERATURE SWITCH H SPLICE F CANOPY RISER WATERFLOW H BOX #1 F B CANOPY RISER OS &Y P HI -LOW PRESSURE SWITCH F A5 �— GARDEN CENTER CANOPY IF r F.P. PANEL. 503 A5 NOTE: WIRE TO FIRE ALARM CONTACT. 503 120 VAC EM. CKT. WIRE TO TROUBLE CONTACT. B FIRE DOOR CLOSE RELAYS B CONVEYOR. SHUTDOWN RELAY F s s s s FIRE DOOR SMOKE DETECTORS (SEE PLANS FOR QUANITY) F m BAKERY HOOD ALARM CONTACT (B26A) F m DELI HOOD ALARM CONTACT (D26B) F T AMERICAN GRILL HOOD ALARM CONTACT (S26B #U F m CHINESE CAFE HOOD ALARM CONTACT (S26B #3) F m CHINESE CAFE HOOD ALARM CONTACT (S26B #2) F n n DATA TELEPHONE SMOKE DETECTORS F - Ts FRONT DUCT SMOKE DETECTOR (SEE PLANS FOR QUANTITY) F l s s s CENTER DUCT SMOKE DETECTOR (SEE PLANS FOR QUANTITY) s s s F s s s s s s s s REAR DUCT SMOKE DETECTOR (SEE PLANS FOR QUANTITY) T 5 T� T i T� T T� i (E2 FIRE SYSTEM ONE LINE DIAGRAM 'NE 503 • 2 1 P• • O O A a A I • mi �I • m A o m � o+ o Z Q C7 Z Y w :2 O O •IO+o+AloO o o •) • o A O A o+ o O z 3 0 v w > o Q w C a ; m o A o 0 o A o 0 c) 6 c\ o Ln CIN r- 0 c • • A. A • A • `,;tttttt1111�1���,'''4 U. iw C w im ,�j,nLL0 sZa: :� 000 , °•• SRO `\��• 4,,� hr /1111111 • 0 00 N rn 0 z w J LL- • L� 0 wZ w C:) z 6w _j W LLJ Q z v A A O A • i 0 W ♦� .-1 nU � W W O��! Uw • • • • • O O w J LL_ 00 w N-). w z CV 0) 0 -� Z o o V) r— 0 w 0 w L 0 w of 0 cn J Q LiJ 0 >_ LJ U Lo • A • • Lo 0 4 LL r` qT CR gM CD cn o N cm CD c co o c U (D c co O uj Y � S '0 L J W I1 • C I C 1� I• � • • E