Loading...
HomeMy WebLinkAboutS4I SEE 3' -0' SITE SLAB, ARCH. #4 AT 12 "o.c. F— SEE SITE PLAN DW �— FIN. FLR. EL. 849' -0" s 1 —#4 12' CONCRETE cl, BLOCK 6" 14 AT 4'- 0'o.c. 0 3 — #5 _I 2' -0' M SECTION 4 3/4' = 1' -0' S1 A 5s /s" SEE as 3' -0' SITE SLAB, ARCH. #4 Al 12 o.c. I- I SEE SITE PLAN DWG. I FIN. FLR. EL 849' -0' �_ FIN. FLR. EL. 849' -0" 6 CONCRETE :.. a •:.. ° ...:....... a. :: BLOCK - - --�� ANCHOR BOLTS, 1 _ #4--> SEE ARCH. DWGS.. 12" CONCRETE FOR SIZE AND i BLOCK t SPACING 00 4' CONCRETE oO 12" CONCRETE N BLOCK "' BLOCK 6" 6" #4 AT 4'- 0'o.c. #4 AT 4'- 0 "o.c. 0 0 3 — #5 3 -5 d 2' -0' C.> 2' -4" n SECTION 3 SECTION 2 3/4" = 1' -0" S1 3/4' = 1' -0" S1 j 14 AT 12 "o.c. (TYP.) 1' /z" CLR. 1 — #4 CONT. (TYP.) �—T/SLAB EL. = 849' -0" li r " PROVIDE #5 CORNER BARS 4 CLR. FOR THE HORIZONTALS N 2'-0 6 °O #5 AT 12" (TYP.) M EL = 845' -0" CONTINUOUS :: NOTE NO. 1 WATERSTOP 6 8 #5 AT 12" (TYP.) (TYPICAL) o I— 3" CLR. KEY WAY (TYP.) Ir NOTE: 1. BLOCKOUT REQUIRED FOR ELEVATOR CYLINDER INSTALLATION. VERIFY BLOCKOUT SIZE AND LOCATION WITH ELEVATOR SUPPLIER. SECTION 5 3/4' = 1' -0" S1 0 I a 1 "0 A36 ANCHOR BOLT ' . st w/ DOUBLE NUTS AND a• °' WASHERS FOR LEVELING 5" ANCHOR BOLT DETAIL D 1 1/2" = 1' -0" S4, S6 A PIER DETAIL H 1 1/2" = 1' -0" S4 1'/2" CLR. IT ) 0 9s /8" /—SIZE ANCHOR BOLTS, SEE ARCH. DWGS. FOR AND SPACING FIN. FLR. EL. 849' -0" 10" CONCRETE BLOCK 4" CONCRETE 12" CONCRETE BLOCK BLOCK 00 N 6" #4 AT 4'- 0 "o.c. 0 3 — #5 2' -4" L) i� SECTION 1 3/4' = 1' -0' S1 11/2" CLR. ILO t j ' t � 'O• PIER DETAIL 'C- 1/2" = 1' -0" S4 in 1" - 4" .. 11' —ID" BASE PLATE DETAIL G 1 1/2" = 1' -0" S4 I I 1'/2" CLR. (TYP.) t c PIER DETAIL e 1/2" = 1' -0" S4 n V m1,/ "- 17 ".,1' -0" BASE PLATE DETAIL F 1 1/2" = 1' -0" S4 COLUMN SCHEDULE A -2, A -3, A -4, A -5, A -6, C -4, D -2.2 B -5, B -3, B -4 C -1, A -7, B.2 .7, B -2, C -7, C -2, C -5, E -3 B -6, D.5 -1 D.5 -2, F -2, E -2, E -4 D -4 C -6 C -3, F -2.9, F -4 D -3 T F -+ AdkENI& CONSULTING ENGINEERS Ter Horst, Lamson & Fisk, Inc. 2629 Waterfront Parkway East Drive Suite 100 Indianapolis, IN 46214 t t t o 0 0 0.• Phone: 317 -328 -1500 alo Fax: 317- 328 -9383 co JL W10 x 33 W10 x 39 W10 x 45 W10 x 49 W10 x 33 W10 x 39 W10 x 45 W10 x 49 W8 x 24 5G�S EqF�.• ':� F1' "x10 "XV -0' R1' /z'x10'xt' -0" P1' /z "x10'x1' -0. 1�1'/z x12'x1' -0" 1'/2'x10 "x1' -0' R1' /2'x100x1' -0' z "x10'x1' -0' t1' /i x12'xV -0' It1 "x8 "x0' -10" = � NO' /2 - #870332: , E E E F E E E F G STATE OF D-. 4 — 1 "4 D: '4 — 1 "0 D: 4 — 1 "0 D: 4 — 1 "0 D: 4 — 1 "0 D: 4 — 1 "4 D: 4 — 1'0 D: 4 — 1 "0 D: 2 — 1 "0 Certified By* ''s' aNA0 848' -6 848'-6" 84-8'-6m 848' -6 848'-2" 848'-2* 848 —2 848'-2* 848' -6 / o I i / T;1z �o 1'/2" CLR. (TYP-) i l s/s" 8Y." PIER DETAIL A 1/2" = 1' -0" S4 0 Ad BASE PLATE DETAIL E 1 1/20 = 1' -0" S4 A PIER SCHEDULE COLUMN MARK z 0 z J O U T /STEEL EL. = 874 -3" 2nd FLOOR EL. = 862 -4" FIRST FLOOR EL. = 849' -0" P1 20" x 20" COLUMN SIZE 14 AT 12" BASE PLATE SIZE BASE PLATE DETAIL P2 ANCHOR BOLTS 4 — #7 B /BASE PLATE EL. REMARKS PIER DETAIL e 1/2" = 1' -0" S4 n V m1,/ "- 17 ".,1' -0" BASE PLATE DETAIL F 1 1/2" = 1' -0" S4 COLUMN SCHEDULE A -2, A -3, A -4, A -5, A -6, C -4, D -2.2 B -5, B -3, B -4 C -1, A -7, B.2 .7, B -2, C -7, C -2, C -5, E -3 B -6, D.5 -1 D.5 -2, F -2, E -2, E -4 D -4 C -6 C -3, F -2.9, F -4 D -3 T F -+ AdkENI& CONSULTING ENGINEERS Ter Horst, Lamson & Fisk, Inc. 2629 Waterfront Parkway East Drive Suite 100 Indianapolis, IN 46214 t t t o 0 0 0.• Phone: 317 -328 -1500 alo Fax: 317- 328 -9383 co JL W10 x 33 W10 x 39 W10 x 45 W10 x 49 W10 x 33 W10 x 39 W10 x 45 W10 x 49 W8 x 24 5G�S EqF�.• ':� F1' "x10 "XV -0' R1' /z'x10'xt' -0" P1' /z "x10'x1' -0. 1�1'/z x12'x1' -0" 1'/2'x10 "x1' -0' R1' /2'x100x1' -0' z "x10'x1' -0' t1' /i x12'xV -0' It1 "x8 "x0' -10" = � NO' /2 - #870332: , E E E F E E E F G STATE OF D-. 4 — 1 "4 D: '4 — 1 "0 D: 4 — 1 "0 D: 4 — 1 "0 D: 4 — 1 "0 D: 4 — 1 "4 D: 4 — 1'0 D: 4 — 1 "0 D: 2 — 1 "0 Certified By* ''s' aNA0 848' -6 848'-6" 84-8'-6m 848' -6 848'-2" 848'-2* 848 —2 848'-2* 848' -6 / o I i / T;1z �o 1'/2" CLR. (TYP-) i l s/s" 8Y." PIER DETAIL A 1/2" = 1' -0" S4 0 Ad BASE PLATE DETAIL E 1 1/20 = 1' -0" S4 A PIER SCHEDULE MARK SIZE VERTICAL REINFORCEMENT TIES DETAIL REMARKS P1 20" x 20" 4 — #7 14 AT 12" A P2 18' x 24' 4 — #7 #4 AT 12" B F3 P3 18" x 20" 4— #7 #4 AT 12 C 5' -6" x 5' -6" x 1' -2" P4 12" x 12" 4— #7 #4 AT 12" H #5 ® 11" E.W. NOTES: 1. SEE TYPICAL PIER & FOOTING DETAIL, AND GENERAL NOTES ON DRAWING S6. FOOTING SCHEDULE MARK SIZE REINFORCING STEEL REMARKS BOTTOM TOP F1 4' -0" x 4' -0" x 1' -0" #5 ® 12" E.W. — F2 4' -6" x 4' -6" x 1' -0" #5 ® 12" E.W. — F3 5' -0" x 5' -0" x 1' -0" #5 0 12" E.W. — F4 5' -6" x 5' -6" x 1' -2" #5 ® 12" E.W. — F5 6' -0' x 6' -0" x 1' -2" #5 ® 11" E.W. — F6 6' -6' x 6' -6" x 1' -4" #5 ® 10" E.W. — F7 7' -0" x 7' -0" x 1' -6" #6 ® 15" E.W. — F8 8' -0" x 8' -0" x 1' -8" #7 ® 18' E.W. — aW F9 8' -0" x 5' -0" x 1' -0" #5 ® 12' E.W. F10 9' -0" x 7' -0" x 1' -6" #6 ® 15" E.W. — F11 L 2' -0" x 2' -0" x 1' -0" #5 ® 12" E.W. — NOTES: -v 1. ALL COLUMNS HAVE BEEN DESIGNED FOR A MAXIMUM NET ALLOWABLE SOIL BEARING PRESSURE OF 3000 psf. AN APPROVED TESTING LABORATORY SHALL VERIFY THAT THE SOIL BEARING CAPACITY IS ACCEPTABLE AT EACH COLUMN FOOTING. 2. SEE TYPICAL PIER do FOOTING DETAIL AND GENERAL NOTES ON DRAWING S6. M W � }- I o . N z O z 0 N > IQ- CK D� Z Q 0 w 0 0 a J aW O m m v m V oN N C y rn ai ' v) ° V) ; v r- v m (L U W T n O E"1 WO � Q Z Q W W ^ Q W � U W 0=0-4 Q0 v—•{ V--4 Title SCHEDULES, SECTIONS & DETAILS Sheet No.: .4, 4-4 D1\92QS2 \4 `_ 02/1749