HomeMy WebLinkAboutS6i
SEE PLAN FOR CONTROL
CONTINUOUS SAWED OR JOINT LOCATIONS
HAND - TOOLED JOINT, '/4" MAX
SEAL JOINT PER
SPECIFICATIONS EDGE RADIUS =
SLAB REINFORCING I V.- MINIMUM °/3
'/4" MAXIMUM
i
WELL COMPACTED
7" (:I FAR I 7" N FAR GRANULAR FILL
I
NOTE:
1. SAWCUT JOINT AS SOON AS POSSIBLE WITHOUT RAVELING THE
EDGE OF CONCRETE.
TYPICAL CONTROL JOINT (C.J).
CONSTRUCTION JOINT SHALL BE
LOCATED AT A CONTROL JOINT
SEE NOTE 1 I °/3 SLAB REINFORCING
COMPACTED
GRANULAR PAINT JOINT w/ 4" THICKENED SLAB
FILL (TYP.) BOND BREAKER I FOR D S 8"
11 -4" 8" 8' 1' -4"
I
NOTE:
1. 3/4 "0 SMOOTH, GREASED DOWELS (NO BURRS) 1' -4" LONG AT 16 "o.c.
IN PLACE OF 2" x 4" KEYWAY.
TYPICAL CONSTRUCTION JOINT
I
I I
II
I I
I I
n
EL 848' -4"
2" NON- SHRINK
GROUT
SEE DETAIL D /S4
FOR ANCHOR
04 SEE PIER SCHEDULE
BOLT INFO. ON SHEET S4 FOR
TYP. TIE SPACING PIER AND REINFORCING
INFORMATION
EL. 846' -4" 1
SEE FOOTING SCHEDULE I `J LAA•
ON SHEET S4 FOR FOOTING
SIZE AND REINFORCING
TYPICAL PIER DETAIL
LOCATE AT
JOIST PANEL
C1 C1 POINT (TYP.)
TYP. '/4"
MECHANICAL
UNIT
n i n n 1r
O Q i O U O
HANGER (IYP.) -- -�
W
2" CLEAR U
(TYP.)
'/2 PREMOLDED JOINT
MATERIAL ALL AROUND.
(SEAL) (TYPICAL)
C.J.
11 -0"
PROVIDE 2 - #5
(1 -TOP AND 1- BOTTOM)
AT EACH CORNER OF
PENETRATION (TYPICAL)
CONTROL OR CONSTRUCTION
JOINT (TYPICAL)
J
J '9.P C.J.
I �
imm
�� NE
CONCRETE COLUMN OR PIER
PENETRATING SLAB ON GRADE
(TYPICAL)
2 - #5 IN TOP OF
SLAB (TYPICAL)-
SLAB ON GRADE
(SEE PLAN)
2' -0'
(TYPICAL)
PREMOLDED
JOINT MATERIAL
EDGE OF SLAB
(TYPICAL)
N
2" CLEAR
(TYP-)
J ^
U
TYPICAL SLAB -ON -GRADE PIER AND COLUMN PENETRATIONS
STEEL COLUMN
JOINT FILLER
SLAB ON GRADE WITH SEALANT (TYP.)
(TYPICAL)
EL = 849' -0"
CONCRETE INFILL
L r1•
-- - T/P = 848' -4"
CONCRETE PIER
I
TYPICAL EXTERIOR COLUMNM WRAP DETAIL
CONCRETE BLOCK
CONCRETE PIER
r--- DOVETAIL ANCHOR SLOT
PROVIDE ANCHOR
AT EVERY COURSE
TYPICAL PIER TO MASONRY CONNECTION
C1
NOTE:
EACH WELD
CAPACITY TO
BE 1.Ok
BY MECHANICAL C1
CONTRACTOR C1 C1 JOIST PER JOIST PER
PLAN HANGER ROD PLAN
AS REQUIRED
FL (BY MECH.
1.Ok MAX. HANGER CONTRACTOR)
T�IC� PLAN _OAD (PER HANGER)
OF HANGING UNIT -i I LABEL.• C1 = C5 x 6.7
TYPICAL DETAIL FOR MECHANICAL UNIT
JOINT FILLER
EL. 849' -0"
EL. 848 -2"
EL. 848' -0"
LSEE FOOTING SCHEDULE
ON SHEET S4 FOR FOOTING
SIZE AND REINFORCING
TYPICAL INTERIOR ISOLATION JOINT
2' -6"
SEE PLAN FOR FINISH
2" CLR. FLOOR ELEVATION
J
I
2 - #5 BY 4' -0"
(TYPICAL 4 SIDES
OF FLOOR DRAIN)
TYPICAL FLOOR DRAIN DETAIL
GENERAL NOTES
FOUNDATIONS
1. PREPARE ALL AREAS OF THE SITE SUPPORTING STRUCTURE BY REMOVING ALL
TOPSOIL, EXISTING FILL, ORGANIC MATERIAL, OR FROZEN, WET, SOFT,
LOOSE OR OTHERWISE UNSUITABLE MATERIALS.
2. PROOFROLL THE EXPOSED SUBGRADE WITH A MEDIUM - WEIGHT ROLLER TO
DETERMINE IF ANY POCKETS OF SOFT, UNSUITABLE MATERIAL EXIST BENEATH
THE EXPOSED SUBGRADE. REMOVE ANY UNSUITABLE MATERIAL ENCOUNTERED
AND REPLACE WITH A PROPERLY COMPACTED GRANULAR MATERIAL
3. COMPACT ALL GRANULAR FILL SUPPORTING FOOTINGS TO 100 PERCENT STANDARD
MAXIMUM DRY DENSITY AND BENEATH INTERIOR SLABS ON GRADE TO 95 PERCENT
STANDARD MAXIMUM DRY DENSITY, ASTM D -698. COMPACT ALL BACKALL NOT
SUPPORTING SLABS, PAVEMENT OR FOOTINGS TO 90 PERCENT MODIFIED MAXIMUM
DRY DENSITY, ASTM D -1557. PLACEMENT, COMPACTION AND MATERIAL USED FOR
FILL SHALL BE OVERSEEN BY THE TESTING AGENCY.
4. PLACE ALL GRANULAR FILL MATERIAL IN LAYERS NOT EXCEEDING 8 INCHES
IN LOOSE THICKNESS. MECHANICALLY COMPACT EACH LAYER TO AT LEAST
THE REQUIRED MINIMUM DRY DENSITY. SEE SEC11ON 02200, EARTHWORK OF THE
PROJECT MANUAL FOR COMPACTION METHODS AND FIELD QUALITY CONTROL
REQUIREMENTS.
5. FOOTINGS NOT SUPPORTED BY ENGINEERED FILL SHOULD BEAR ON FIRM,
UNDISTURBED MATERIAL. IF UNSUITABLE MATERIAL IS ENCOUNTERED,
REESTABLISH THE BEARING ELEVATION OF THE FOOTING BY LOCALIZED
UNDERCUTTING AND FILLING WITH SUITABLE ENGINEERED FILL OR CONCRETE
AS RECOMMENDED BY THE TESTING AGENCY.
6. THE OWNER SHALL EMPLOY A TESTING AGENCY WHICH SHALL VERIFY THAT THE
SOIL BEARING CAPACITY IS ACCEPTABLE AT EACH COLUMN FOOTING AND AT
8' -0" INTERVALS ALONG WALL FOOTINGS AT THE INDICATED BEARING ELEVATIONS.
MINIMUM REQUIRED BEARING CAPACITY IS 3000 PSF.
7. PLACE FOOTINGS THE SAME DAY EXCAVATIONS ARE OPENED. IF THIS IS NOT
POSSIBLE, ADEQUATELY PROTECT THE EXPOSED MATERIAL IN THE BASES OF
THE FOOTING EXCAVATIONS FROM ANY DETRIMENTAL CHANGE IN CONDITION
SUCH AS FROM DISTURBANCE, RAIN OR FREEZING. SURFACE RUNOFF SHALL
NOT BE ALLOWED TO ENTER THE EXCAVATIONS.
8. PLACE ALL FOOTINGS IN WOOD FORMS.
9. CENTER ALL COLUMN AND WALL FOOTINGS UNDER THE COLUMN OR WALL ABOVE
UNLESS OTHERWISE INDICATED.
10. ALL BACKFILL PLACED AGAINST WALLS SHALL BE A WELL- GRADED GRANULAR
MATERIAL APPROVED BY THE TESTING AGENCY.
11. PLACE SLABS ON GRADE ON 6 INCHES OF PROPERLY COMPACTED, FREE
DRAINING GRANULAR MATERIAL APPROVED BY THE TESTING AGENCY.
12. FOR DETAILS OF SUBSURFACE CONDITIONS, REFER TO SOILS REPORT
PREPARED BY ATEC ASSOCIATES, INC., DATED NOVEMBER 30, 1992.
13. THE OWNER SHALL EMPLOY A QUALIFIED INDEPENDENT SOIL TESTING AGENCY
TO VERIFY THAT ALL EXCAVATION AND BACKFILL OPERATIONS MEET THE
CRITERIA OF THESE NOTES, THE SPECIFICATIONS AND THE SOILS REPORT.
14. ENGINEERED FILL SHALL BE CLEAN, WELL GRADED AND FREE DRAINING IN
ITS COMPACTED STATE. THE MATERIAL SHALL CONFORM TO THE GRADATION
REQUIREMENTS OF "B" BORROW SIZE LISTED IN THE IDOH STANDARD
SPECIFICATIONS.
15. GRANULAR FILL MATERIAL SHALL BE A "PIT RUN GRAVEL" AS IT OCCURS IN
THE NATURAL STATE WITH NO LUMPS OF CLAY OR ROCKS LARGER THAN 2
INCHES IN DIAMETER. IT MUST CONFORM TO THE FOLLOWING GRADATIONS:
10 TO 40 PERCENT SAND, 40 TO 80 PERCENT GRAVEL AND 0 TO 15 PERCENT
CLAY. OBTAIN FROM BORROW PIT APPROVED BY THE OWNER AND THE TESTING
AGENCY.
CONCRETE
1. UNLESS NOTED OTHERWISE ON THE DRAWINGS, PROVIDE 3/4 INCH CHAMFERS
ON ALL EXPOSED CORNERS OF CONCRETE EXCEPT THOSE ABUTTING MASONRY.
2. FINISH CONCRETE SLABS ON STEEL DECK TO THE TOLERANCE SPECIFIED IN
SECTION 03300, CAST -IN -PLACE CONCRETE, OF THE PROJECT MANUAL.
MAINTAIN THE REQUIRED MINIMUM SLAB THICKNESS AT ALL LOCATIONS
INCREASING THE THICKNESS AS REQUIRED FOR STEEL DECK DEFLECTION,
BEAM DEFLECTION AND RESIDUAL BEAM CAMBER.
CONCRETE SCHEDULE
CLASS
28 DAY
COMPRESSIVE STRENGTH
AIR CONTENT
CONCRETE
PLACEMENT
i
M
CONCRETE PIER
r--- DOVETAIL ANCHOR SLOT
PROVIDE ANCHOR
AT EVERY COURSE
TYPICAL PIER TO MASONRY CONNECTION
C1
NOTE:
EACH WELD
CAPACITY TO
BE 1.Ok
BY MECHANICAL C1
CONTRACTOR C1 C1 JOIST PER JOIST PER
PLAN HANGER ROD PLAN
AS REQUIRED
FL (BY MECH.
1.Ok MAX. HANGER CONTRACTOR)
T�IC� PLAN _OAD (PER HANGER)
OF HANGING UNIT -i I LABEL.• C1 = C5 x 6.7
TYPICAL DETAIL FOR MECHANICAL UNIT
JOINT FILLER
EL. 849' -0"
EL. 848 -2"
EL. 848' -0"
LSEE FOOTING SCHEDULE
ON SHEET S4 FOR FOOTING
SIZE AND REINFORCING
TYPICAL INTERIOR ISOLATION JOINT
2' -6"
SEE PLAN FOR FINISH
2" CLR. FLOOR ELEVATION
J
I
2 - #5 BY 4' -0"
(TYPICAL 4 SIDES
OF FLOOR DRAIN)
TYPICAL FLOOR DRAIN DETAIL
GENERAL NOTES
FOUNDATIONS
1. PREPARE ALL AREAS OF THE SITE SUPPORTING STRUCTURE BY REMOVING ALL
TOPSOIL, EXISTING FILL, ORGANIC MATERIAL, OR FROZEN, WET, SOFT,
LOOSE OR OTHERWISE UNSUITABLE MATERIALS.
2. PROOFROLL THE EXPOSED SUBGRADE WITH A MEDIUM - WEIGHT ROLLER TO
DETERMINE IF ANY POCKETS OF SOFT, UNSUITABLE MATERIAL EXIST BENEATH
THE EXPOSED SUBGRADE. REMOVE ANY UNSUITABLE MATERIAL ENCOUNTERED
AND REPLACE WITH A PROPERLY COMPACTED GRANULAR MATERIAL
3. COMPACT ALL GRANULAR FILL SUPPORTING FOOTINGS TO 100 PERCENT STANDARD
MAXIMUM DRY DENSITY AND BENEATH INTERIOR SLABS ON GRADE TO 95 PERCENT
STANDARD MAXIMUM DRY DENSITY, ASTM D -698. COMPACT ALL BACKALL NOT
SUPPORTING SLABS, PAVEMENT OR FOOTINGS TO 90 PERCENT MODIFIED MAXIMUM
DRY DENSITY, ASTM D -1557. PLACEMENT, COMPACTION AND MATERIAL USED FOR
FILL SHALL BE OVERSEEN BY THE TESTING AGENCY.
4. PLACE ALL GRANULAR FILL MATERIAL IN LAYERS NOT EXCEEDING 8 INCHES
IN LOOSE THICKNESS. MECHANICALLY COMPACT EACH LAYER TO AT LEAST
THE REQUIRED MINIMUM DRY DENSITY. SEE SEC11ON 02200, EARTHWORK OF THE
PROJECT MANUAL FOR COMPACTION METHODS AND FIELD QUALITY CONTROL
REQUIREMENTS.
5. FOOTINGS NOT SUPPORTED BY ENGINEERED FILL SHOULD BEAR ON FIRM,
UNDISTURBED MATERIAL. IF UNSUITABLE MATERIAL IS ENCOUNTERED,
REESTABLISH THE BEARING ELEVATION OF THE FOOTING BY LOCALIZED
UNDERCUTTING AND FILLING WITH SUITABLE ENGINEERED FILL OR CONCRETE
AS RECOMMENDED BY THE TESTING AGENCY.
6. THE OWNER SHALL EMPLOY A TESTING AGENCY WHICH SHALL VERIFY THAT THE
SOIL BEARING CAPACITY IS ACCEPTABLE AT EACH COLUMN FOOTING AND AT
8' -0" INTERVALS ALONG WALL FOOTINGS AT THE INDICATED BEARING ELEVATIONS.
MINIMUM REQUIRED BEARING CAPACITY IS 3000 PSF.
7. PLACE FOOTINGS THE SAME DAY EXCAVATIONS ARE OPENED. IF THIS IS NOT
POSSIBLE, ADEQUATELY PROTECT THE EXPOSED MATERIAL IN THE BASES OF
THE FOOTING EXCAVATIONS FROM ANY DETRIMENTAL CHANGE IN CONDITION
SUCH AS FROM DISTURBANCE, RAIN OR FREEZING. SURFACE RUNOFF SHALL
NOT BE ALLOWED TO ENTER THE EXCAVATIONS.
8. PLACE ALL FOOTINGS IN WOOD FORMS.
9. CENTER ALL COLUMN AND WALL FOOTINGS UNDER THE COLUMN OR WALL ABOVE
UNLESS OTHERWISE INDICATED.
10. ALL BACKFILL PLACED AGAINST WALLS SHALL BE A WELL- GRADED GRANULAR
MATERIAL APPROVED BY THE TESTING AGENCY.
11. PLACE SLABS ON GRADE ON 6 INCHES OF PROPERLY COMPACTED, FREE
DRAINING GRANULAR MATERIAL APPROVED BY THE TESTING AGENCY.
12. FOR DETAILS OF SUBSURFACE CONDITIONS, REFER TO SOILS REPORT
PREPARED BY ATEC ASSOCIATES, INC., DATED NOVEMBER 30, 1992.
13. THE OWNER SHALL EMPLOY A QUALIFIED INDEPENDENT SOIL TESTING AGENCY
TO VERIFY THAT ALL EXCAVATION AND BACKFILL OPERATIONS MEET THE
CRITERIA OF THESE NOTES, THE SPECIFICATIONS AND THE SOILS REPORT.
14. ENGINEERED FILL SHALL BE CLEAN, WELL GRADED AND FREE DRAINING IN
ITS COMPACTED STATE. THE MATERIAL SHALL CONFORM TO THE GRADATION
REQUIREMENTS OF "B" BORROW SIZE LISTED IN THE IDOH STANDARD
SPECIFICATIONS.
15. GRANULAR FILL MATERIAL SHALL BE A "PIT RUN GRAVEL" AS IT OCCURS IN
THE NATURAL STATE WITH NO LUMPS OF CLAY OR ROCKS LARGER THAN 2
INCHES IN DIAMETER. IT MUST CONFORM TO THE FOLLOWING GRADATIONS:
10 TO 40 PERCENT SAND, 40 TO 80 PERCENT GRAVEL AND 0 TO 15 PERCENT
CLAY. OBTAIN FROM BORROW PIT APPROVED BY THE OWNER AND THE TESTING
AGENCY.
CONCRETE
1. UNLESS NOTED OTHERWISE ON THE DRAWINGS, PROVIDE 3/4 INCH CHAMFERS
ON ALL EXPOSED CORNERS OF CONCRETE EXCEPT THOSE ABUTTING MASONRY.
2. FINISH CONCRETE SLABS ON STEEL DECK TO THE TOLERANCE SPECIFIED IN
SECTION 03300, CAST -IN -PLACE CONCRETE, OF THE PROJECT MANUAL.
MAINTAIN THE REQUIRED MINIMUM SLAB THICKNESS AT ALL LOCATIONS
INCREASING THE THICKNESS AS REQUIRED FOR STEEL DECK DEFLECTION,
BEAM DEFLECTION AND RESIDUAL BEAM CAMBER.
CONCRETE SCHEDULE
CLASS
28 DAY
COMPRESSIVE STRENGTH
AIR CONTENT
CONCRETE
PLACEMENT
REMARKS
A
4.000 PSI
OPTIONAL
Al
4000 PSI
OPTIONAL
Tn O
WITH SYNTHETIC
FIBERS
B
4000 PSI
6 ±1%
SEE NOTE 3
91
4000 PSI
6 f 1%
SEE NOTE 3
WITH SYNTHETIC
�
a
FIBERS
1. ANY CONCRETE NOT INDICATED IN THE SCHEDULE SHALL BE CLASS B.
2. FOR ADDITIONAL INFORMATION SEE SECTION 03300, CAST -IN -PLACE
CONCRETE, OF THE PROJECT MANUAL.
3. SUBSTITUTE CLASS "B" OR "B1" CONCRETE FOR ALL CONCRETE THAT WILL BE EXPOSED
TO FREEZE - THAW CONDITIONS DURING CONSTRUCTION AND /OR SERVICE.
REINFORCING STEEL
1. FOR SMALL OPENINGS AND SLEEVES IN CONCRETE SLABS SPREAD THE
REINFORCING STEEL SO THAT THE BAR SPACING DOES NOT EXCEED 1.5 TIMES
THE NORMAL SPACING.
2. PROVIDE CLASS "A" TENSION LAP SPLICES FOR ALL HORIZONTAL WALL REINFORCEMENT
UNLESS NOTED OTHERWISE ON THE DRAWINGS.
3. CORNERS OF ALL OPENINGS AND REENTRANT CORNERS IN THE SLAB ON GRADE WILL BE
REINFORCED WITH (2) - 15 BARS BY 4' -0" LONG PLACED DIAGONALLY WITH THE CORNER
AND LOCATED AT MID -DEPTH OF THE SLAB. BEND BARS IF REQUIRED TO AVOID CROSSING
CONTROL JOINT (C.J.) LOCATIONS.
4. FOR ADDITIONAL INFORMATION SEE SECTION 03200, CONCRETE REINFORCEMENT, OF THE
PROJECT MANUAL
l
1
AAf
ot .e
($a `
STRUCTURAL STEEL !`
1. ALL FIELD CONNECTIONS SHALL BE BOLTED UNLESS OTHERWISE DETAILED ON
THE STRUCTURAL DRAWINGS.
2. CONNECTION ANGLES SHALL BE DOUBLE WEB ANGLES, 5/16 INCH MINIMUM
THICKNESS.
3. FOR ALL BEAMS FRAMING OVER THE TOP OF A COLUMN, PROVIDE 1/4 INCH
STIFFENER PLATES EACH SIDE OF THE BEAM WEB UNLESS OTHERWISE NOTED
ON THE DRAWINGS.
4. BURNING OF HOLES IN STRUCTURAL STEEL SHALL NOT BE ALLOWED WITHOUT
APPROVAL OF THE ARCHITECT /ENGINEER.
5. FABRICATE SIMPLE SPAN BEAMS WITH NATURAL CAMBER UPWARD.
6.. SUB -BASE (LEVELING) PLATES WILL NOT BE ALLOWED UNDER COLUMN BASE
PLATES.
7. GROUT UNDER COLUMN BASE PLATES SHALL BE HIGH - STRENGTH, NON-
METALLIC, NON- SHRINK.
8. VERIFY LINES, LEVELS, ANCHOR BOLT SETTINGS AND GENERAL FIELD
CONDITIONS BEFORE MAKING SHOP DRAWINGS. REPORT DISCREPANCIES TO
THE ENGINEER.
9. ALL SHELF ANGLES AND RELIEVING ANGLES WHICH SUPPORT MASONRY AND ARE
CONNECTED TO THE STRUCTURE SHALL HAVE PROVISION FOR VERTICAL AND
LATERIAL ADJUSTMENT. NUTS FOR SUCH ANGLES SHALL BE DRAWN UP TIGHT
AFTER THE ANGLES ARE POSITIONED BY THE MASON. (THIS IS EXTREMELY IMPORTANT).
10. FOR ADDITIONAL INFORMATION SEE SECTION 05100, STRUCTURAL STEEL, OF
THE PROJECT MANUAL
WOOD CARPENTRY AND FABRICATED WOOD TRUSSES
1. SEE PROJECT MANUAL, SECTION 06192.
2. WOOD TRUSSES SHALL BE DESIGNED FOR THE BUILDING LIVE LOADS AS SHOWN
BELOW. IN ADDITION TO THE LIVE LOADS SPECIFIED, THE TRUSS MANUFACTURER
SHALL DESIGN THE TRUSSES FOR THE ADDITIONAL LOADS SPECIFIED IN
SPECIFICATION SECTION 06192, ARTICLE 1.4.C.3.
COORDINATION WITH OTHER TRADES
1. THE GENERAL CONTRACTOR SHALL COORDINATE AND CHECK ALL DIMENSIONS
RELATING TO ARCHITECTURAL FINISHES, MECHANICAL OPENINGS, EQUIPMENT,
ETC. THE ARCHITECT/ ENGINEER SHALL BE NOTIFIED OF ANY
DISCREPANCIES BEFORE PROCEEDING WITH WORK IN THE AREA UNDER
QUESTION.
2. THE MECHANICAL CONTRACTOR SHALL VERIFY THAT ALL MECHANICAL UNITS
SUPPORTED BY THE STRUCTURAL FRAMING ARE CAPABLE OF SPANNING THE
DISTANCE BETWEEN THE SUPPORT FRAMING PROVIDED FOR BY THE STRUCTURAL
DRAWINGS. THE MECHANICAL CONTRACTOR SHALL PROVIDE ADDITIONAL
SUPPORT FRAMING AS REQUIRED.
3. THERE SHALL BE NO VERTICAL OR HORIZONTAL SLEEVES SET, OR HOLES CUT
OR DRILLED IN ANY JOIST, BEAM OR COLUMN UNLESS IT IS SHOWN ON THE
STRUCTURAL DRAWINGS OR APPROVED BY THE ARCHITECT/ENGINEER IN
WRITING.
4. MECHANICAL OPENINGS THROUGH CONCRETE SLABS LARGER THAN 8 INCHES IN
DIAMETER, NOT SHOWN ON THE STRUCTURAL DRAWINGS, MUST BE APPROVED BY
THE ARCHITECT/ENGINEER. ALL OPENINGS 8 INCHES IN DIAMETER OR
LESS SHALL HAVE AT LEAST 1' -0" CLEAR BETWEEN OPENINGS UNLESS
APPROVED BY THE ARCHITECT /ENGINEER.
EXISTING CONSTRUCTION
1. VERIFY ALL EXISTING DIMENSIONS, ELEVATIONS AND CONDITIONS BEFORE
PROCEEDING WITH NEW CONSTRUCTION. NOTIFY THE ARCHITECT /ENGINEER OF
ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK IN THE AREA UNDER
QUESTION.
2. PREVENT UNDERMINING OF THE FOUNDATIONS OF EXISTING STRUCTURES.
TAKE PROTECTIVE MEASURES SUCH AS SHORING, BRACING OR UNDERPINNING
AS REQUIRED TO PREVENT DAMAGE TO THE EXISTING STRUCTURES.
3. FOR ADDITIONAL INFORMATION SEE SECTION 02400, SHORING, BRACING AND
UNDERPINNING, OF THE PROJECT MANUAL.
DESIGN DATA
1. SOIL INFORMATION
ALLOWABLE NET BEARING PRESSURE, COLUMN FOOTINGS... 3000 PSF
WALL FOOTINGS ........... ............................... ...................,.......2500 PSF
2. CONCRETE
COMPRESSIVE STRENGTH ............................. ............................SEE CONCRETE SCHEDULE
3. REINFORCING STEEL
MAIN REINFORCEMENT ................................... ..........................A615, GRADE 60
WELDED WIRE FABRIC ................................... ...........................ASTM A -185
4. STRUCTURAL STEEL
STRUCTURAL TUBING MEMBERS .................... ..........................A500, FY = 46 KS
STEEL PIPE ......... ............:................. ...........................ASTM A53 GRADE B OR A501
ALL OTHER MEMBERS .................................. ............................A36
CONNEC11ON BOLTS ...................................... ...........................3 /4" DIAMETER, A325N BEARING
TYPE WITH STD. 13/16' DIAMETER
HOLES (U.O.N.)
ANCHOR BOLTS ................................ ............................... A36
5. BUILDING LIVE LOADS:
OFFICES AND RESTROOMS ........................... .............................50 PSF
CORRIDORS ................... ............................... ............................100 PSF
MECHANICAL ROOMS .... ............................... ............................100 PSF
ROOF (SNOW) .............................................. .............................20 PSF
BOTTOM CHORD OF ROOF TRUSSES ........... .............................10 PSF
6. WIND LOADS:
BASIC WAND SPEED ..................................... .............................75 MPH
IMPORTANCE FACTOR ........................ _...: .... ....... ..................... 1.0
EXPOSURE.................................................. ..............................B
7. SEISMIC:
SEISMIC ZONE ............................................ ..............................1
I.................................................................. ............................1.0
Z..................................... ............................... ..........................0.075
S.................................................................. ............................1.0
Rw............................................................ ............................... 6�`''
71
CONSULTING ENEEFt
Ter Norst, Lamson & Fisk, Inc.
2629 Waterfront Parkway
East Drive Suite 100
Indianapolis, IN 46214
Phone: 317- 328 - I SN
Fax: 317- 328 -9383~
Cj'�Q�d \STEgF�
- t
'z
#870332
A . STATE OF
Certified�i,`fn?
N
O Z
0
0�
> Cie
W H
� o
p r,3 m m
Z N M
co .,, �-
0 N N N c v x
e 6 1 - 3 m
•o o •� c L
d 0 0 0 U
E4
rr4
Tn O
U
Wo
�
a
Z
I�
U)
i�i
W
J
LLI
a
W �
I!°-W
r4
e"--I
Title:
GENERAL NOTES
AND
TMCAL DETAILS,j
Sheet No..:
MIT-'
+• �� �� - fit`.
Wf
e