Loading...
HomeMy WebLinkAbout0825.96.16Z rn m 6i Q R L R L m a J U- m w CC a a t cc N J U i IN AN "Aft PARTIAL PLAN -- MECHANICAL EQUIPMENT PAD SCALE: 1/,( - 1' -17' ON SAME SIDE OF "T" BEAMS \ 1° 1" OVERLAP OF BOARDS ON OPPOSITE SIDES OF "T" BEAMS 2" x 4" "T" BEAM. 3 READ. BETWEEN EACH 4" x 4" POST O- METAL JOIST - HANGERS (TYP.) BOTTOM FIRST "T" BEAM N 1/ TOP FOOTER GRADE ROOF PLAN 1" x 8' x 6' -0" LONG BOARDS. SPACE AS SHOWN. BOTTOM TO BE FLUSH WITH BOTTOM OF BOTTOM "T" BEAM II I II II I II 4' x 4" x 10' -0" LONG II I II POSTS 0 8' -0" 0/C II I II II I II II I II II II SET ALL POSTS IN CONCRETE II II 8" DIA. 0 8' -O" 0/C SCALE: 1/4! = 1' -17 BOTTOM FOOTER TYPICAL CONSTRUCTION -- WOOD SCREENING FENCE NOTE: ALL LUMBER TO BE WOLMANIZED rol GENERAL NOTES: O CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE AND WATERTIGHT ROOFING SYSTEM O CONTRACTOR IS REPPONSIBLE FOR INSTALLATION OF ROOF EDGE AND RIDGE FLASHING, ALL COUNTER FLASHING, ROOF PENETRATION BOOTS, GUTTERS, ETC. O CONTRACTOR IS RESPONSIBLE FOR PROPER INSTALLATION OF ROOF SHINGLES NAILED IN PLACE BY QUALIFIED TRADESMAN, STRICTLY ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. O ALL FLASHING TO BE PREnNISHED OR JOB PAINTED TO MATCH TRIM COLOR. INSTALL PREFINISHED GUTTERS AND DOWNSPOUTS. CONSTRUCTION NOTES: o-,, 1. ROOF FINISH SHALL BE SHINGLE ROOFING SYSTEM. CONTRACTOR TO PROVIDE do INSTALL DECK, FELTS, SHINGLES, FLASHINGS, GUTTERS, DOWNSPOUTS do ALL RELATED MATERIALS TO COMPLETE THIS ROOF AREA SLOPE TO GUTTERS AS INDICATED. 2 ROOF SHEATHING TO BE 5/8" CDX PLYWOOD SHEATHING WITH CLIPS AT ABUTTING FREE EDGES 0 2' -O" OC. STAGGER JOINTS 0 4' -0" MINIMUM. 3. INSTALL 5 "x6" GUTTER USING SPACERS 0 30"0.C. MAXIMUM, ATTACHED TO FASCIA FRAMING. 4. INSTALL 3 "x4" DOWNSPOUTS WHERE SHOWN. SECURE TO WALL WITH MINIMUM OF 2 HANGERS. SEE PLOT PLAN FOR POSSIBLE UNDERGROUND PIPING. 5. 4" FLUE FROM GAS WATER HEATER - -- PROVIDE THIMBLES AT PENETRATIONS. ANY LATERAL RUN SHALL OCCUR IN TRUSS SPACE, MAINTAINING REQUIRED SLOPE. DO NOT RUN LATERALS IN CAVITY BETWEEN SUSPENDED CEILING AND UNDERSIDE OF TRUSSES. PROVIDE SUPPORT AS NEEDED. 6. VENT THROUGH ROOF. SEE PLUMBING DRAWINGS FOR SIZE do CONTINUATION. I APPROVED ROOFING SYSTEMS: I SHINGLE ROOFING AREAS: OWENS- CORNING - 40 YR. OAKRIDGE SHADOW COLOR: HARBOR BLUE - 350# SEAL -TITE PREPARED FOR: _ A Springfield, y of Mwatoon 01 Company PREPARED BY: mmm2 on 009 convony Mad ed & Transportdon Engineering Dept. Findlay, 45840 REVISIONS Q 1996 EMRO MARKETING COMPANY 17486 a STD. ROOF PLAN (GROUND -MTD HVAC EQUIP.) REAR ISLAND STORE 44' —f' x 64 ' —T LEFT HAND BUILDING SCALE t - 1' DATE FILE 45 —RL DRFTR RCMA 2 -19-96 NO. CHKR Run_ RVWR FILMD 'fL AM 1 A -3