PARTIAL PLAN -- MECHANICAL EQUIPMENT PAD
SCALE: 1/,( - 1' -17'
ON SAME SIDE OF "T" BEAMS \ 1°
1" OVERLAP OF BOARDS ON
OPPOSITE SIDES OF "T" BEAMS
2" x 4" "T" BEAM. 3 READ.
BETWEEN EACH 4" x 4" POST
O-
METAL JOIST -
HANGERS (TYP.)
BOTTOM FIRST
"T" BEAM
N
1/
TOP FOOTER
GRADE
ROOF PLAN
1" x 8' x 6' -0" LONG BOARDS.
SPACE AS SHOWN. BOTTOM TO
BE FLUSH WITH BOTTOM OF
BOTTOM "T" BEAM
II I II
II I II 4' x 4" x 10' -0" LONG
II I II POSTS 0 8' -0" 0/C
II I II
II I II
II I II
II II SET ALL POSTS IN CONCRETE
II II 8" DIA. 0 8' -O" 0/C
SCALE: 1/4! = 1' -17
BOTTOM FOOTER TYPICAL CONSTRUCTION --
WOOD SCREENING FENCE
NOTE: ALL LUMBER TO BE WOLMANIZED
rol
GENERAL NOTES:
O CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE AND WATERTIGHT ROOFING SYSTEM
O CONTRACTOR IS REPPONSIBLE FOR INSTALLATION OF ROOF EDGE AND RIDGE FLASHING, ALL COUNTER FLASHING,
ROOF PENETRATION BOOTS, GUTTERS, ETC.
O CONTRACTOR IS RESPONSIBLE FOR PROPER INSTALLATION OF ROOF SHINGLES NAILED IN PLACE BY
QUALIFIED TRADESMAN, STRICTLY ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.
O ALL FLASHING TO BE PREnNISHED OR JOB PAINTED TO MATCH TRIM COLOR.
INSTALL PREFINISHED GUTTERS AND DOWNSPOUTS.
CONSTRUCTION NOTES: o-,,
1. ROOF FINISH SHALL BE SHINGLE ROOFING SYSTEM. CONTRACTOR TO PROVIDE do INSTALL DECK, FELTS,
SHINGLES, FLASHINGS, GUTTERS, DOWNSPOUTS do ALL RELATED MATERIALS TO COMPLETE THIS ROOF AREA
SLOPE TO GUTTERS AS INDICATED.
2 ROOF SHEATHING TO BE 5/8" CDX PLYWOOD SHEATHING WITH CLIPS AT ABUTTING FREE EDGES 0 2' -O" OC.
STAGGER JOINTS 0 4' -0" MINIMUM.
3. INSTALL 5 "x6" GUTTER USING SPACERS 0 30"0.C. MAXIMUM, ATTACHED TO FASCIA FRAMING.
4. INSTALL 3 "x4" DOWNSPOUTS WHERE SHOWN. SECURE TO WALL WITH MINIMUM OF 2 HANGERS. SEE PLOT PLAN
FOR POSSIBLE UNDERGROUND PIPING.
5. 4" FLUE FROM GAS WATER HEATER - -- PROVIDE THIMBLES AT PENETRATIONS. ANY LATERAL RUN SHALL OCCUR
IN TRUSS SPACE, MAINTAINING REQUIRED SLOPE. DO NOT RUN LATERALS IN CAVITY BETWEEN SUSPENDED
CEILING AND UNDERSIDE OF TRUSSES. PROVIDE SUPPORT AS NEEDED.
6. VENT THROUGH ROOF. SEE PLUMBING DRAWINGS FOR SIZE do CONTINUATION.
I APPROVED ROOFING SYSTEMS: I
SHINGLE ROOFING AREAS:
OWENS- CORNING - 40 YR. OAKRIDGE SHADOW
COLOR: HARBOR BLUE - 350# SEAL -TITE
PREPARED FOR: _
A
Springfield, y of Mwatoon 01 Company
PREPARED BY:
mmm2 on 009 convony
Mad ed & Transportdon Engineering Dept.
Findlay, 45840
REVISIONS
Q 1996 EMRO MARKETING COMPANY
17486 a
STD. ROOF PLAN
(GROUND -MTD HVAC EQUIP.)
REAR ISLAND STORE
44' —f' x 64 ' —T
LEFT HAND BUILDING
SCALE t - 1' DATE FILE 45 —RL
DRFTR RCMA 2 -19-96 NO.
CHKR Run_
RVWR
FILMD
'fL
AM 1 A -3