Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0825.96.27
co rn _rn rn N v bi 0 m L ra c 0 Z a J m w i z 0 a Q _ F_ Im Q N J cn cD a 0 0 A 2" PVC SLEEVE THRU WALL FOR WATER LINES 12" AFF VENT FWH -1 EXTEND TO WIDTH OF WALL SAN - 3• F 1 IF - -- - i - 4' RUN FILTERED WATER - - - THRU WALL POST MIX DISPENSER • & ICE CUBER al 6' -0" - -- -_ - FROZEN CARBONATED BEVERAGE FREEZER FD-2 Fn_q _ - -- - 4" CONTINUED ON ICE CUBER & 3• TE DRAWING STORAGE BIN G 5' -0 t (MIN.) REMOTE WATER METER READER 2 1' DCW �-2SUPPLY FD -1 TO ICE �LW. -3 o \ MAKER �� - - - \ 6" PVC LONG SWEEP ELBOWS 1 4" FROM WATER FILTER TO - COFFEE /COCOA DISPENSERS FD -1 S_1 HS- 1 - F TO COFFEE & COCOA -. } Li nz. �' -� TO POST -MIX _ — — _ & CARBONATED FROZEN BEVERAGE VENT VENT VENT 105'F P -1 GREASE INTER C ---PTOR A P -1 4" FWH -1 3/4" DCW UP TO .. VENT CEILING SPACE - j - r FD-2 WC-1 a _ FD-2 L 2 Z o ABOVE CEILING o TO SANITARY SEWER La. FOR CONTINUATION 3' -7" 6' -2" SEE SITE DRAWING SSS2 . a SAN SAN 4" 4" CO AT GRADE _/ 140' �-s- 314" TO KITCHEN SINK S -2 & SS -1 3/4" THERMOSTATIC MIXING VALVE 10 GPM AT 10 PSI PRESSURE LOSS. CONCENTRIC REDUCERS (TYP.) r 3/4" DIELECTRIC 3/4" N. G. UNION (TYP.) (AS REQ'D) �— CONNECT TO GAS MAIN GAS COCK Z WH -1 III UNION 1" ROD HANG FROM ROOF TRUSSES TEMP.& PRESSURE RELIEF VALVE. DRAIN VALVE SUPPLIED WITH TANK WATER HEATER NO SCALE (VERIFY IF NATURAL GAS, P -1 PROPANE OR ELECTRIC) THERMOMETER (TYP.) (RANGE 30° -24CP ) UNION (TYP.) r BALL VALVE (TYP.) 3/4" DHW i 105° � 4 3/4" DCW � 1" DCW — SAN E 1/ 14 . /FT. FLOOR PLAN - PLUMBING SCALE: 1/4!i =1' -0 1' DCW TO REMOTE METER BUILDING SYSTEM READER PRESSURE GAUGE (RANGE 0 -160 LBS� O UNION (TYPICAL) A "'�f I 3/4' DRAIN N.O. N.O. WITH VACUUM WATER BREAKER METER N.C. DCW BACK -FLOW PREVENTER STATION FLOOR DRAIN -- REQUIRED WITH BACKFLOW CHECK VALVE INSTALL PER LOCAL UTILITY REQUIREMENTS LF` INSIDE WATER METER PIPING DIP-71 AIL NO SCALE SAN COOLER EVAP. COIL 3/4" CD - HIGH AS POSSIBLE -SLOPE 1 /4" /FT. COOLER EVAP. COIL i i A i 0 TRAP OUTSIDE COOLER FD -1 VENT FWH -1 13' -5" M NOTE: PROVIDE SHUT -OFF VALVE TO EACH PIECE OF EQUIPMENT WATER FILTER DETAIL NO SCALE P -1 GENERAL NOTES: PLUMBING RDMS NOT IDEN70 ON THIS SHEET WILL BE FOUND ON THE DELI EQUIPMENT PLAN SHEET ALL INDIRECT WASTE, SANITARY & VENT DRAINAGE PIPING WILL BE PVC -DWV PLASTIC SCHEDULE 40 ASTM D2665. ALL WATER PIPING ABOVE GROUND SHALL BE TYPE 'L' COPPER -LEAD FREE SOLDER. CONDENSATE DRAINAGE (CD) SHALL BE COPPER TYPE 'L' - LEAD FREE SOLDER. PIPE BELOW GROUND SHALL BE TYPE 'K' COPPER WITH NO JOINTS. ALL LINES INSULATED WITH FLEXIBLE ELASTOMERIC PIPE INSULATION 25 FLAME SPREAD, AND 50 SMOKE DEVELOPMENT - ARMSTRONG CAP ARMAFLEX, OR EQUIVALENT. WATER HAMMER ARRESTOR SIZE PER PLUMBING AND DRAINAGE INSTITUTE STANDARD WH -201, ASSE STANDARD 1010, PURN -1700. INSTALL BALL TYPE SHUT OFF VALVES (WATER -NIBCO # S- 590 -Y) PRIOR TO CONNECTING TO ANY PIECE OF EQUIPMENT - TYPICAL. - - - - -- ALL DRAIN CONNECTIONS IDENTIFIED AS "OPEN CONNECTION" AND INDIRECT WASTE SHALL HAVE A MINIMUM 2" AIR GAP BETWEEN DRAIN DISCHARGE AND SANITARY PIPING. ALL DRAIN LINES ARE TO BE TRAPPED AT THE EQUIPMENT BEING CONNECTED, UNLESS NOTED OTHERWISE. TOP OF WIER OF TRAP OF ALL FLOOR DRAINS TO BE NO HIGHER THAN TOP OF 4" MAIN LINE TO WHICH THE DRAINS ARE CONNECTED. ALL EXPOSED PLUMBING PIPE AND VALVES SHALL BE WRAPPED WITH "BROCAR" TRAP WRAP AND FLIP TOP COVER ACCESS. PLUMBING EQUIPMENT LIST do NOTES: OWATER FILTER SYSTEM - 1/2" DIA. WATER LINE TO BE ROUGHED IN ® 65" A.F.F. PROVIDE SHUTOFF VALVE & UNION ON INLET SIDE. OCONNECT TO EVAPORATOR CONDENSATE COILS OF WALK -IN COOLER WITH 3/4" CONDENSATE DRAIN (CD). RUN 3/4" DRAIN ALONG WALL OF COOLER TO FLOOR DRAIN. INSULATE 3/4" DRAIN FOR FREEZE PPROTECTION - AT FLOOR DRAIN INSTALL A 3" DEEP TRAP. OGREASE INTERCEPTOR: FURNISH AND INSTALL (FLUSH WITH FLOOR) 'ZURN #1170 SIZE 700, 4" INLET /OUTLET OR APPROVED EQUAL, 35 GPM /70# GREASE TRAP. INSTALL AS SHOWN. FIELD LOCATE GREASE TRAP. SIZING: VOLUME OF NEW SINK = (19%16%12")0 = 10944 CU.IN. VOLUME = 10944 CU.IN./ 231 CU.IN. /GAL = 47.4 GAL. ACT. DRAIN LOAD = 75%x47.4 GAL. = 35.3 GAL, REO'D FLOW RATE = 35.0 GPM GAS WATER HEATER SCHEDULE NO. DIA HWff i SMWE FLUE BTUH EWWT LWT RECOVERY REMARKS GN.LONS SIZE INPUT 'F 'F GPH WH -1 20' 50 114' 40 IT 1 34,000 40 140 32.2 LOCHINVAR MODEL #ESN040 NOTE: PROVIDE 4" INSULATED VENT STACK IF GAS IS USED. (CONTRACTOR SUPPLIED & INSTALLED) E "A" TO POST MIX DISPENSER )ZEN CARBONATED BEVERAGE DISPENSER LINE "B" TO COFFEE MAKERS, COCOA DISPENSER AND ICE MAKERS N DRAIN LINE TO RAIN (OPEN CONNECTION) ELECTRIC WATER HEATER SCHEDULE NO. a HEK;t(T STORAGE NO. OF KW PER TOTAL EV IV RECOVERY REMARKS G&LONS ELEMENTS ELEMENT KW 'F •F GPH •WH -1 24' 37' 47 2 4.5 9 40 140 48 FIELD VERIFY ELECTRICAL 25 AMPS, 208V, THREE PHASE, LACHINWAR MODEL fESKO5OKK PLUMBING FIXTURE LIST 0 = OWNER C = CONTRACTOR DESCRIPTION WATER CLOSET - 'AMERICAN STANDARD' CADET ELONGATED 17" HEL 1 6 P MODEL 2168 100 COMPLETr 0 WITH SUPPLY & TANK FITTINGS, ACCESSORIES & OLSENITE OPEN FRONT SEAT 195 (N6 LID) OR WC -1 1/2" - -- 4" 2" C C DOMESTIC HOT WATER 105'F APPROVED EQUIVALENT (ADA WHITE). PRESSURE GAUGE w/VALVE & RANGE PG /-\ DOMESTIC HOT WATER 149E DHW WATER HAMMER ARRESTOR w /PDI SIZE WHA HAND SINK, 'METAL MASTERS' HSA -10 -FA STAINLESS STEEL WALL MOUNTED HAND SINK THERMOMETER w /RANGE GW GREASE WASTE GW — WALL HYDRANT FWH C C WITH FAUCET, SUPPLIES, TRAP AND MOUNTING BRACKETS. S -1 112- 1/2- 1 1/2- 1 1/2" IW VTR VENT THRU ROOF VTR 3- COMPARTMENT SINK - METAL MASTERS MODEL 412- 16- 3 -18RL WITH METAL MASTERS CD o-- CLEANOUT CO BALL VALVE BV FFE FINISHED FLOOR ELEVATION FFE GAS PLUG COCK MODEL #301002 14', 1 112" WASTE FITTING w /LR HANDLE, 1 1/2" CONTINUOUS WASTE, TRAP: 'P' S -2 3/4" 3/4" 2" r 0 C GR 1 1/2, 17 GAUGE TRAP. - FURNISH WITH 8' S SPLASH GUARD, LEFT SIDE MOP SERVICE BASIN - "FLORESTONE PRODUCTS" MODEL JMSR -2424, 24 7x24 "x10" CENTER DRAIN, © 1996 EMRO MARKETING COMPANY Q► /� . 's ? I' _. 17 c PREPARED FOR: C bkwew /wb14t.r WITH MR -370 HOSE END CLAMP, MR -371 FAUCET, VACUUM BREAKER, BUCKET HOOK, MR -372 SS -1 112" 1/2" 3" 1 1/2" C C MOP HANGER, MR -373 RIM GUARDS, AND M -374 WEDGE -LOH SEAL �t zit' of aZNmu PREPARED BY: mmmt II on ON �mTO ll� Mwkeflrg 5 Transportdon Engineering Dept. ° Findlay, OH 45840 LAVATORY - 'AMERICAN STANDARD" LUCERNE, MODEL 10356.015 20 112" x 18 1/4" COMPLETE WITH 0. FtEVISKM FITTINGS, STRAINER, TRAP AND HANGER (WHITE). FAUCET - 'CHICAGO' MODEL J404A -317 WITH BLADE L -1 1/2" 112- 1 1/2- 1 112- C C HANDLES. FREEZELESS WALL HYDRANT "ZURN' MODEL #Z- 1321,3/4" CONNECTION (OR APPROVED EQUIVALENT.) 3/4^ ___ ___ ___ C C WITH INTERGRAL VACUUM BREAKER AND AUTOMATIC DRAINING. FWH -1 FLOOR DRAIN w./FUNNEL (ZURN Z -415 & Z -414) (FUNNEL) FD -1 - -- - -- 3" 2" C C FLOOR DRAIN (ZURN Z -415) FD -2 - -- - -- 3" 2" C C FLOOR DRAIN (HUB) - 'JOSAM' 149530 -3 8" TOP - 6" DEEP - 112" GRATE - 4" OUTLET, NO FLANGE FD -3 C.O - -- - -- 4" 2" C C CLEANOUTS, 'ZURN" IZ- 1400 -Z (INSIDE USE) "ZURN' j'Z -1455 (OUTSIDE USE) - -- - -- 4" - -- C i C GREASE INTERCEPTOR, "ZURN" MODEL #1170, SIZE 700 WITH FLOW CONTROL O - -- - -- 4" 2" C C THERMAL EXPANSION TANK - "AMTROC MODEL j ST -12 TST 3/4" DRFTR RCMA C C i PLUMBING LEGEND DOMESTIC COLD WATER DCW DOMESTIC HOT WATER 105'F DHW PRESSURE GAUGE w/VALVE & RANGE PG /-\ DOMESTIC HOT WATER 149E DHW WATER HAMMER ARRESTOR w /PDI SIZE WHA THERMOMETER w /RANGE GW GREASE WASTE GW — WALL HYDRANT FWH SAN SANITARY ABOVE FLOOR SAN FLOOR DRAIN FD V VENT SANITARY V FLOW DIRECTION IW INDIRECT WASTE IW VTR VENT THRU ROOF VTR CD CONDENSATE DRAIN CD o-- CLEANOUT CO BALL VALVE BV FFE FINISHED FLOOR ELEVATION FFE GAS PLUG COCK GPC PLUMBING CONTRACTOR P.C. NG NATURAL GAS PIPING NG NORMALLY OPEN N.O. GAS REGULATOR GR © 1996 EMRO MARKETING COMPANY Q► /� . 's ? I' _. 17 c PREPARED FOR: C bkwew /wb14t.r Songfielcl, OH 45601 V •, a� y o NAnithon � 01 Company �t zit' of aZNmu PREPARED BY: mmmt II on ON �mTO ll� Mwkeflrg 5 Transportdon Engineering Dept. ° Findlay, OH 45840 0. FtEVISKM PLUMBING PLAN REAR ISLAND STORE 44' -19r x 64 ' -Ir LEFT HIND BUILDING SCALE 1/4!'= l' - O" DATE FILE 45 —RL DRFTR RCMA 2 -19 -96 NO. CHKR BUD. YR. DGNR AdA...'otgo g Al,rrt RVWR v K. T P_ FILMD N0.