L0 rn rn dri 66 0 L_ C 0 J Li- m w z 0 a Q _ z 0 Q Q z N J c� 0 0 GAS METER BY GAS CO. SEE DETAIL SHEET M -2 NG - GAS LINE BELOW GRADE SEE SITE PLAN FOR CONTINUTION Fol EF -2 CE I ICE MACHINE CONDENSER WALK -IN COOLER CONDENSER !J 11 FLOOR PLAN - MECHANICAL HVAC EQUIPMENT LIST DESCRIPTION O PAD -MTD HVAC UNIT - (HV -1) TRANE jYCH09OC3LOA 208 VOLT /3 PH. WITH CONTROL PANEL, THERMOSTAT, 3,000 CFM S/A 0 .75 STAT. PRESS., 92,000 BTUH SEN. COOLING, 120,000 BTUH HEATING INPUT (NATURAL GAS). (ONE) 1 HP EVAPORATOR FAN, (ONE) 7.5HP COMPRESSOR 0 27.0 R.L.A., AND (ONE) 0.5 HP CONDENSER FAN 0 3.4 F.L.A. UNIT WEIGHT = 800 LBS, CURB WEIGHT = 82 LBS PROVIDE WITH 5 YEAR WARRANTY, CURB, CURB INSULATING KIT, SMOKE DETECTOR, SMOKE DETECTOR ANNUNCIATOR, AND SAMPLE TUBE TO BE FIELD INSTALLED. UNIT SHALL ALSO HAVE ECONOMIZER AND POTENTIOMETER KIT RLY123 FIELD INSTALLED AND INTERLOCKED WITH THERMAL RELIEF FAN. C PAD -MTD HVAC UNIT - (HV -1) TRANE JTCH090C300A 208 VOLT /3 PH. W/ CONTROL PANEL, THERMOSTAT, 3,000 CFM S/A ® .75 STATIC PRESSURE, 92,000 BTUH SEN. COOLING 12.9 KW INPUT (ELECTRIC HEAT). (ONE) 1 HP EVAPORATOR FAN, (ONE) 7.5HP COMPRESSOR 0 27.0 R.L.A., AND (ONE) 0.5 HP CONDENSER FAN 0 3.4 F.L.A. UNIT WEIGHT = 700 LBS, CURB WEIGHT = 82 LBS PROVIDE WITH 5 YEAR WARRANTY, CURB, CURB INSULATING KIT, SMOKE DETECTOR, SMOKE DETECTOR ANNUNCIATOR, AND SAMPLE TUBE TO BE FIELD INSTALLED. UNIT SHALL ALSO HAVE ECONOMIZER AND POTENTIOMETER KIT RLY123 FIELD INSTALLED AND INTERLOCKED WITH THERMAL RELIEF FAN. O2 EXHAUST FAN - (EF -1 do EF -2) TRANE FDUAO15, 150 CFM 0 .125 S.P. 1550 RPM, 100 WATTS, W/ VWC WALL CAP, INTERLOCK W /LIGHT SWITCH. O RETURN AIR GRILLES - LIMA ALUMINUM SERIES 90 RAH 22'X22- (NO SCREW HOLES) O CEILING DIFFUSER - LIMA ALUMINUM SERIES 95 SMOB 111 6"x6" WITH A 6"DIA. TRANSITION - (6" DIA. TRANSITION BY CONTRACTOR) O CEILING DIFFUSER - LIMA ALUMINUM SERIES 95 FMOB -24 311 9" x9" WITH A 8" DIA. TRANSITION O CEILING DIFFUSER - LIMA ALUMINUM SERIES 95 FMOB -24 311 12 "x12" WITH A 12" DIA. TRANSITION O CEILING DIFFUSER - LIMA ALUMINUM SERIES 95 FMOB -24 411 12%12" 12" WITH A 12" DIA. TRANSITION O THERMAL RELIEF EXHAUST WALL FAN - TRANE MODEL #FDWA1000OAIBA, EQUIPPED WITH DAMPER, WALL GRILLE, AND THERMOSTATIC CONTROLLER O CEILING DIFFUSER - LIMA ALUMINUM SERIES 95 FMOB -24 111 -6"x6" WITH 6" DIA. TRANSITION 0 = OWNER C = CONTRACTOR QUANTITY FURNISHED BY INSTALLED BY 1 1 0 C I 1 0 1 C 2 0 C 3 0 C 2 0 C N EVAPORATOR SECT boo - - ACCESS PANEL -\ 112' WT GAS CONNECTION CONTROL do COMPRESSOR ACCESS PANEL i i i i i i i i I i i i i i r7 .10 �\ '6 16. 2' DIA. HOLE (UNIT POWER WIRES) 7/8" DIA. HOLE (UNIT CONTROL WIRES) NOTE: RECOMMENDED CLEARANCE 4t FRONT. 36' SIDES, lEr OVERALL DMAENSKk1S CRATED 37.5H X 50.8W 85.5 D CURB DIMENSIONS : CLEARANCE 36" CLEARANCE 18' HORIZONTAL 1 0 C \ \ 3 0 C 5 0 C CLEARANCE 48' CLEARANCE 36" 1 0 C HVAC PAD MOUNTED UNIT (7 112 TON) 1 0 C SCALE: NONE (SIDE DISCHARGE) GENERAL NOTES: • REFER TO DRAWING IM -2 FOR TYPICAL DETAILS. • CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS, INSPECTIONS, & LICENSES NECESSARY TO COMPLETE THIS INSTALLATION AND THE SATISFACTORY OPERATION OF THE SYSTEM. • CONTRACTOR SHALL SET AND LEVEL UNIT. O HVAC UNITS SHALL BE CHECKED OUT UPON COMPLETION OF INSTALLATION TO INSURE THAT THEY ARE FUNCTIONING PROPERLY AND STARTUP FORMS AND AIR BALANCE REPORT SUBMITTED TO OWNER'S ENGINEER. O OWNER SHALL SUPPLY HVAC PACKAGE FROM TRANE CORPORATION. PACKAGE INCLUDES HVAC UNITS, THERMOSTATIC CONTROL SYSTEMS, DIFFUSERS AND ADAPTER BOOTS FOR DIFFUSERS. MECHANICAL CONTRACTOR SHALL FURNISH DUCTWORK, HANGERS AND ADDITIONAL ITEMS REQUIRED FOR A COMPLETE INSTALLATION PER CODES AND THIS DRAWING. TRANE CORPORATION - -- CONTACT: DENNIS GOLDSMITH PHONE: (419) 866 -4000 O ALL DUCT SIZES ARE INSIDE DIMENSIONS. PROVISIONS SHALL BE MADE FOR INTERNAL INSULATION OF SUPPLY AND RETURN AIR DUCTS. O MINIMUM 8 1/2- CLEARANCE REQUIRED BETWEEN DUCT AND CEILING GRID. O ALL HVAC EQUIPMENT SHALL BE WIRED WITH COPPER CONDUCTOR TO VALIDATE MANUFACTURERS WARRANTY. O RETURN PLENUM, INTERIOR MAIN SUPPLY AND RETURN DUCTS TO BE 1-1/2 THICK OWENS /CORNING DUCT BOARD J475 F.R.K. O DIFFUSER THROW AND CFM TO BE AS SPECIFIED BY THIS DRAWING. O ALL BRANCH DUCT -TO DIFFUSER CONNECTIONS RUNS TO BE OWENS /CORNING FIBERGLASS VALUFLEX (EXCEPT AS NOTED). MAXIMUM LENGTH OF FLEXIBLE DUCT RUN SHALL BE LIMITED TO 5' BY INSTALLATION OF RIGID LATERALS AS REQUIRED. • ALL PLENUMS AND SUPPLY DUCT RUNS TO BE HELD TIGHT TO BOTTOM OF TRUSS (BELOW DRAFT STOP) • THE OUTSIDE MAKE -UP AIR DAMPERS FOR EACH HVAC UNIT SHALL BE SET SO THAT A MINIMUM OF 15% OF THE AIR COMES FROM THE OUTSIDE. • NEW FILTERS SHALL BE INSTALLED AFTER CONSTRUCTION CLEAN -UP & BEFORE STORE OPENING. 12 SPARE FILTERS PER HVAC UNIT SHALL BE LEFT ON JOB SITE. • NATURAL OR LP GAS PIPE ABOVE GROUND = BLACK STEEL (2" AND SMALLER) SCHEDULE 40, GRADE ASTM A120, SCREWED 150 PSI BLACK MALLEABLE IRON FITTINGS; VALVES (PLUGS -TYPE) = ROCKWELL- NORDSTORM, FIGURE 142J UNIONS = 300 PSI, MALLEABLE IRON, GROUND JOINT. • CONTRACTOR TO PROVIDE NATURAL OR LP GAS PIPE SUPPORTS EVERY 10' ON CENTER. • ALL EXTERIOR SUPPLY AND RETURN DUCT TO BE LOW PRESSURE SHEET METAL, RECTANGULAR, GALVANIZED, FABRICATED ACCORDING TO SMACNA LOW VELOCITY DUCT MANUAL (PLATE 5 THRU 15) AND ASHRAE GUIDE. EXTERNAL DUCT INSULATION TO BE OWENS /CORNING COMMERCIAL GRADE FIBERGLAS DUCT WRAP TYPE 100, FOIL REINFORCED KRAFT PAPER BARRIER FACED WITH 2" STAPLING FLANGE, 1.0 PCF DENSITY, K -0.27 COATED WITH "JAXSAN 600" (GRAY) AS MANUFACTURED BY PLASTIC COATINGS CORPORATION (304)755 -9151 AND (304)755 -9153 (FAX). MECHANICAL NOTES: A. EACH RETURN GRILLE SHALL BE FITTED WITH A TRANSITION FROM 2'x2' TO 20" DIAMETER (SUPPLIED BY CONTRACTOR CONNECT TRANSITION TO RETURN PLENUM USING 20" DIA. DUCT RETURN PLENUM IS NOT T INTERFERE WITH LIGHTING BELOW. B. ALL RESTROOM EXHAUST FANS TO DISCHARGE THRU EXTERIOR WALL 9' -6" AFF, PROVIDE FANS WITH WALL CAPS FOR EXTERIOR WALL PENETRATION, INTERLOCKED WITH ROOM LIGHT SWITCH. C. INSTALL THERMAL - RELIEF EXHAUST FAN AT 8' -0" A.F.F. AND DUCT DIRECTLY THROUGH WALL. BACKDRAFT DAMPER AND RING WALL GRILLES ARE FURNISHED WITH EXHAUST FAN. FAN SHALL BE CONTROLLED BY LINE VOLTAGE THERMOSTAT WIRED TO MAKE ON TEMPERATURE RISE. D. CONNECT SMOKE DECTECTOR (SUPPLIED BY OWNER) AS DETAILED ON SHEET M -2. MATERIAL, OWNER SUPPLIED, INCLUDES SMOKE DETECTOR, REMOTE PANEL AND SAMPLING TUBE. DUCT DETECTORS TO MOUNTED IN THE SUPPLY AIR PLENUM. E. CONTRACTOR TO PROVIDE TAMPER PROOF, LOCKABLE, PLASTIC THERMOSTAT COVERS F. SPIN -IN FITTING EQUAL TO SM -IDEL BY GENERAL ENVIRONMENTAL CORP. G. CONTRACTOR TO PROVIDE 4" DAM. FLUE FROM WATER HEATER TO 3' -0 ABOVE ROOF (GAS WATER HEATER ONLY). VERIFY THAT FLUE IS 10' -0 FROM ANY INTAKE. H. FINAL CONNECTION TO HVAC UNIT TO BE WEATHERPROOF FLEX. LEGEND: SO DUCT MOUNTED SMOKE DETECTOR EXHAUST FAN T 8 F WALL THERMOSTAT LT LINE VOLTAGE THERMOSTAT TO BE MOUNTED AT 84" ABOVE FINISH FLOOR. OA SMOKE ANNUNCIATOR T 400 CFM —3 DIFFUSER WITH AIR QUANTINTY AND FLOW INDICATOR W RETURN AIR GRILLE 9" X 10" RECTANGULAR DUCT 12" DIA. ROUND DUCT FLEX DUCT (5' RUN MAX) PREPARED FOR: F=mro Nkftd H C Springfield, ®45 0 y of Mam#m Oil Company PREPARED BY: mmmoUaOP�t (No C o pa y Marketing & Transportation Engirmering Dept. Flndiay, ®H 45840 NO. REVISIONS �(! © 1996 EMRO MARKETING COMPANY e.dP�TT''4 1748 q� SID .4T : b� t bldg /sbf /*bflm 1.dgn .St•:� �•��1 :�� J' .i l!' I STD. HVAC PLAN (GROUND -MT HVAC EQUIP) REAR ISLAND STORE 44' -8" x 64 ' -g' LEFT HAND BUILDING SCALE 1 4" =l'-O" DIATE FEE 45- RL DRFTR RCMA 2 -12 -96 N0. CHKR DGNR k?0a 1,dAJ 1- 0/. YARD• 'NNO. —1 I