MATERIAL LIST
ANY ELEVATION TRANSITION v-
'CROWN"
_X_
ITEMS NOTED WITH ONE ASTERISK WILL BE FURNISHED AND INSTALLED BY
CONTRACTOR
A
BETWEEN SUMP No RUNS TO
TAKEN
NOTE PAVEMENT SURROUNDING MANHOLE
27
ISLANDS TO BE UP
WITHIN THESE TWO FITTINGS
ITEMS
NOTED WITH TWO ASTERISKS WILL BE FURNISHED BY OWNER AND
rx
l/2 UNION UNION---
INTEGRAL WITH TOKHEIM OR GILBARCO DISPENSERS.
Oplwl 5/16 6
EB 1/4
INSTALLED
BY CONTRACTOR.
_71
- - - -- -
T
NOTE BEDDING AND FILL CAN BE SAND OR GRAVEL.
SEE NOTE •019 ON DWG. •-S150.
TOP OF6HEAR SECTION MUST BE
LEVELI WITH TOP OF ISLAND I DISPENSER OUTLINE
I INTERCOM J-BOX ELECTRICAL J-Box
TOP OF MANHOLE
ITEMS
IN PLOT
L IST FOR
WITHOUT ASTERISKS WILL BE FURNISHED AND INSTALLE9 AS DIRECTED
PLAN "CONSTRUCTION NOTES". REFERENCE MARATHON S EQUIPMENT
DETAILED EQUIPMENT INFORMATION.
L ALTERNATE ROUTING
MAIN RUN PIPING TO SLOPE DOWN 1% MIN.
CONNECTION CONNECTION
y; 6 TO TOP OF PIPE
TO TANK AREA
UNION
SEALOFF UNION
CONCRETE SLAB
2" BALL VALVE, JAMESBURY #4A-220OMT-06
4'-0" WIN.
STUB CONDUIT I SEALOFF
AND CAP IF
DPW 16 3/8' OVERALL—
EBW 14 112' OVERALL
2
2
3" BALL VALVE, APOLLO #89-100
o
NOT USED Ti 71 18 1
3) 4" DROP TUBE, OR OVERFILL PREVENTION VALVE
(SEE EQUIPMENT LIST)
I'-3' /:"
FIBERGLASS ELBOW
39 a A I
4* STEEL NIPPLE
LENGTH AS REDD.'
(4) DOUBLE-TAPPED BUSHING, 4" x 2' x 2"
2' 90'
2' BELL & MALE N.P.T. I FIBERGLASS EIBOV
FIBERGLASS ADAPTER
VAL, DF PIPING TRENCH 7' MIN. FILL
DISPENSER ISLAND
FORM
GALVANIZED PIPE
5 4 x 4 " FILL ADAPTOR, OPW #61AS-2477
22- 22. 30'
PHON
3/; CONDUIT
DAISY-CHAINED TO
0
ABOVE TOP OF PIPE
FINISH GRADE
LENGTH AS REQUIRED
4 x 4" FILL ADAPTOR, OPW 4633T-8076 (SOUTHERN AREA ONLY)
4 FILL CAP, OPW #62TT-7085
(79
S I PUMP
NEXT SUMP IN GROUP
#634TT-7085
RISER SUMP RISER
FOR PPM 4000 SYSTEM
4 x 4 FILL CAP, DPW (SOUTHERN AREA ONLY)
J' CONDUIT FROM BUILDING OR EQUAL (L_ EQUAL It 2' FRP
Yj- CONDUIT DAISY-CHAINED PIPING
FROM PREVIOUS SUIMP FOR CROUSE-HINDS ROUSE -HINDS
IYS21 OR
PPM 4000 SYSTEM EYS21
PROD. A °2
- ----- -- --------------------------------------
-- ------ - - -- ELBOW 2" FIBERGLASS
45' FIBERGLASS
PRODUCT PIPING
I Y2" 40
STL.
PIPE
7 3 x 4 VAPOR RECOVERY ADAPTOR, DPW #16IIAVB-1625
8 3 VAPOR RECOVERY CAP, OPW #171IT-7085
EYS31 SEALOFF 55
%EALOFF OR EQUAL
55 OR EQUAL
8 2 - 45*
�,x X2
2' FIBERGLASS
PRODUCT PIPE 2'x 1
BUSHING
9
4 x 2" EXTRACTOR WITH OR WITHOUT BALL FLOAT
(SEE EQUIPMENT LIST)
CROUSE-HINDS FRP ELBOW
GUAM26 J-BOX
z_
ENTRY Z;7,
RILL 114' HOLE
DRILL
TOP OF TANK "BY CONTRACTOR)
10
VENT CAP
OR EOUA L
FITTINGS �8
55
_tT ELEVATION CHANGE
AT CROSSOVER (REF.) &<><�Kxx 2" S L.
0,
ITE�M U3 NOTfREOUIRED
WITH SED 0 L PUMP OF F 3
11 4" MALE PIPE PLUG
I(D\
2" FIBERGLASS 6 2" PRODUCT
90* E BOW
CONDUITS
12
FINK TEST STATION (FURNISHED WITH TANK)
44)
2
TEE Al 45' PIPING
ALE N.P.T.
55
BEVEL CUT DROP TUBE
[3
1 CHECK VALVE, OPW #70-0070
FIBERGLASS ADAPTER
(BY CONTRACTOR) TANK BOTTOM
2 X 1/2' X 2
FIBERGLASS ELBOI
'111,;01 ✓1
* *
14
CHECK VALVE, MORRISON #246-A
REDUCING TEE 2' STL.
90, E
SUMP, PUMP/SIPHON RISERS
&
CROUSE-HINDS EYS21
SEALOFF OR EQUAL
6' MIN. BED BELOW MINIMUM HORIZONTAL SPACING BETWEEN
AND EITHER SIDE OF PIPE WALLS OF PIPING IN MAIN RUNS.
NOTE: REFER TO PLOT PLAN
DISPENSER FOUNDATION - CORRECT NUMBER, SIZE,
AND LOCATION OF CONDUITS AND PRODUCT PIPING.
THIS DIMENSION CANNOT EXCEED 6' OR CONNECTOR CANNOT BE HOOKED UP
[5
4" SUBMERSIBLE PUMP
LONG AXIS OF PRODUCT TANK
cc
P I P I N G UNDER DISPENSER
X(l
16
6" SUBMERSIBLE PUMP
ti
1 5 A
BRANCH P I P I N G
OR
4
W I THOUT FLEXIBLE CONNECTOR NOTE: SPILL CONTAINER TO BE TIGHTNESS TESTED IN PRESENCE
17 PRODUCT STORAGE TANKS, STEEL OR FIBERGLASS
42' DIA. SECONDARY
CONTAINMENT SLWMP 51
PPM 4000 SYSTEM
CROSSOVER
OF OWNER'S ENGINEER PER MAWFACTURER'S SPECIFICATIONS
PRIOR TO POURING CONCRETE SLAB.
18
2" IMPACT CHECK VALVE
ASSEMBLY 2" NIPPLE
ACCUMULATOR
(PRESSURE SYSTEM)
04 NIOBF-5725 OR UNIVERSAL 521RFS-15
4' LONG
(TOKHEIM, WAYNE, AND GILBARCO ADVANTAGE DISPENSERS)
2' STL.
SIPHON PRIMER
OPW #IOBM-5825 OR UNIVERSAL #521RMS-15
45' ELBOW
CONNECTION
IY UNICIN- -
(ALL GfLBARCO DISPENSERS EXCEPT ADVANTAGE SERIES)
2' x 2, x Y'
2 x 2' x 3/4'
REDUCING TEE
INTEGRAL WITH TOKYM OR GILBARCO DISPENSERS.
8
12" LIMITED ACCESS MONITORING MANHOLE,
REDUCING TEE
TOP OF ISHEAR SECTION MUST BE 1
TOP
MORRISON 418XA (12" X 12"
PPM 4000 SYSTEM
2' STL. NIPPLE 2112' LONG TRANSDUCER
(3 PLACES)
2' STL. 2* STIC.
45' ELBOW 90* ELBOW
2* X 4' LONG
STL. ELBOW STL. NIPPLE
2' BELL & MALE N.P.T.
3y SIPHON FIBERGLASS ADAPTER
PRIMER LINE
CONC. OR ASPH. 12 28
PER PLOT PLAN- MIN. CONC. 2' x 112" STEEL
ALL AROUND REDUCER " TH 112' PLUG
LEVER WITH OF ISLAND DISPENSER OUTLINE
INTERCOM J-BOX ELECTRICAL J- BOX
CONNECTION CONNECTION
UN [ON
/ -
SE UNION
SEALOFF j
18 LIM[ TED ACCESS MONITORING MANHOLE,
MORRISON 418XA (t8" X 12"
2' BELL & MALE NOTE: WHEN TWO PUMPS ARE MANIFOLDED INTO
FRP CHECK N-P.T
ADAPTER A SINGLE DISCHARGE LINE, INSTALL A Au pirlms me CmfT To 1)(11
VALVE (ITEM -14) IN EACH DISCHARGE LINE. MM
/-055
X Y2* X 2 2' FIBERGLASS
REDUCING TEE
SIPHON PIPING
CAP CONDUITS
I' RISE 2' MIN
2' FIBERGLASS - FINISH GRADE
�SEALOFF
STUB CONDUIT
AND CAP IF ILI I
NOT USED 'n TT
21 36" DIM. STEEL MANHOLE
22 4" SCREW-ON PIPE CAP, OPWI16-7085
x
C5
601AUT FW SW
2" FIBERGLASS
------ T - - - - - -
90' ELBOW
x
SIPHON PIPE
(NIPPLE AS RED.
SLOPE UP To
BETWEEN ELBOWS) A
39
23
BUSHING, 4" X 2"
2" FIBERGLASS SIPHON
PIPING. SLOPE DOWN �lc
(SE HIGH END
E NOTE #15)
DISPENSER ISLAND 0
24 DUPLEX BUSHING, 2" X 112" X 112", WITH BRASS
To LOW POINT CONNECTION
AT ADJACENT TANK.
PLAN
i(SEE DETAIL 5
VIEW
SLOPE DOWN TO HOLD,BACKFILL AT
c LOW ENO BOTT M OF MANHOLE
(SEE NOTE -151
2' X 4" LONG
- F
FINISH GRADE
COMPRESSION FITTINGS, UNIVERSAL #751
25 BUSHING, 4" X 3"
SIDE
42' DIN. SECONDARY FIBERGLASS
CONTAINMENT SUMP I ORDER
NIPPLE
AS F ITTING 2
26
3" FILL ADAPTER & CAP, OPW #83-0044
ASSEMBLY
2N BELL & MALE N.F.T.
SLOPE DOWN I% MIN. TO TANK AREA FIBERGLASS ADAPTER
40
27 SPILL CONTAINMENT MANHOLE WITH DRAIN, DPW *1-2100
CONDUITS (REFER TO PLOT PLAN
2" BELL & MALE N. P. T. FOR NUMBER AND SIZE)
FIBERGLASS ADAPTER
28
12 MANHOLE, DEEP SKIRT, OPW #104A 1066,
36' DIM. X 12" DEEP ROUND MANHOLE
12*
NOTE PAVEMENT 'CROWN'
4
2" - go-
FIBERGLASS ELBOW
E)
2' FIBERGLASS
PRODUCT PIPE
29 MECHANICAL LEAK DETECTOR FOR 4" SUBMERSIBLE PUMP
'
SURROUNDING MANHOLE. FINISH GRADE
2' STL. PI F
2' FIBERGLASS
Ic
30
11/ FLEXIBLE CONNECTOR WITH 1'12" MALE SWIVEL
AN� 2" FEMALE END FITTINGS
- I
TANK SHELL TANK SHELL
PRODUCT PIPE
2" STL. PIPE RODUC
&<><2XXXXX>("/ l<
(Dl 2" x 24" FLEXIBLE CONNECTOR WITH 2" MALE SWIVEL
AND 2" FEMALE END FITTINGS
ck)c) MP ON
SUMP ON SUMP
TANK BOTTOM
CONDUITS
9 BELL I A MAI F N.P.T.
55�
* *
(�)
2"x 30" FLEXIBLE CONNECTOR WITH 2" FEMALE
FITTINGS BOTH ENDS
STEEL TANK FG TANK
TANK BOTTOM
F LBERGLASS ADAPTER 30
33
12" OBSERVATION WELL PIPE (FABRIC WRAP BY CONTRACTOR)
NOTE: REFER TO PLOT PLAN &
GROUSE HINDS
DISPENSER FOUNDATION DING. FOR CORRECT NUINEER, SIZE,
34 4" OBSERVATION WELL PIPE (FABRIC WRAP BY CONTRACTOR)
GUAM26 J-BOX
OR EQUAL
tO'-O' TYPICAL
AND LOCATION OF CONDUITS AND PRODUCT PIPING.
35
Yl' SIPHON
AIMER
2" FIBERGLASS 2" FIBERGLASS
PPM 4000 SYSTEM _\ t
90* ELBOW PRODUCT PIPING
N.T.S.
HIGH END
PIPING FOR
LOW END
P I P I N G UNDER D I S P E N S E R
36
4" WELL CAP AND ADAPTOR, MORRISON 678XA
VAPOR RECOVERY ADAPTOR ASSEMBLY, OPW #1611VR
LINE
2 1/
' X Y2' X 2
ACCUMULATOR
PPM 4000 SYSTEM n -
TRANSDUCER
@ FUTURE DISPENSER,
WITH FLEXIBLE CONNECTOR
37 3" x 30" FLEXIBLE CONNECTOR WITH 3" FEMALE UNION
REDUCING TEE
ENTRY
(PRESSURE SYSTEM)
FITTINGS BOTH ENDS
REDUCINGXTlE/l 15
55 FITTINGS
38
3" FLANGED MECHANICAL LEAK DETECTOR FOR 6" SUBMERSIBLE Pump
ANY ELEVATION TRANSITION
2' STL.
5. OW
4 ELBOW
3/; CONDUIT BETWEEN SUMP AND RUNS TO
(pump POWER) ISLANDS TO BE TAKEN UP
WITHIN THESE TWO FITTINGS
NOTE PAVEMENT 'CROWN* SURROUNDING MANHOLE
39
ISLAND FORM
40
DISPENSER CONTAINMENT SUMP
FIELD GLASS BOND JOINT PER
MANUFACTURER'S INSTRUCTIONS
POSITION SHEAR SECTION
AT TOP OF ISLAND DISPENSER OUTLINE
i TOP OF
12* MANHOLE TO T
POSITION SHEAR SECTION
AT TOP Of ISLAND DISPENSER OUTLINE
4t
18" MONITORING MANHOLE OPW IO4MW- 0018
INTERCOM BOX ELECTRICAL J-BOX
CONNECTJION 13 CONNECTION
INTERCOM i-BOX ELECTRICAL J-BOX
103 CONNECT]
CONNECTION ON
42
12" BOLES LOCKING WARNING CAP FOR t2" MONITORING WELL *LC-12.
2" STIC. 2� 2" STL.
45' ELBOW �i
90•
FIBERGLASS 2' FIBERGLASS
45' ELBOW 90* ELBO
JNION
X
1" RISE
_� Dil
1
UNION
TANK SHELL 4 1 7
SEAL OF F UNION
CONCRETE SLAB
SEAL OF F UNION
43
3" x 3" x 2" FLOAT VENT VALVE, DPW #320DV-3" x 3" x 2"
17
42' DIA. SECONDARY
4 -0, MIN.
CONTAINW9%T SUMP
ASSEW Y
S'JB ,ONIDUIT SEALOFF
AND 'AP :F U-CLAMP ANCHOR
4" FIRE COUPLING (BANDEDI
SEALOFF
STUB CONDUIT
N P -CLAMP ANCHOR
A D CA IF TL, _1�
44 4" x 2" x 3" MULTI- OUTLET EXTRACTOR ASSY., OPW lr233MSD-2432
AT\\
NO' JSE D T-1 CIF
I
NOT USED T_ --I F
'GLASS
�39
HOL D BACKFILL AT
BOTTOM OF MANHOLE
1
45
4" x 3" x 3" MULTI OUTLET EXTRACTOR BODY, OPW *233VM-4433
SUMP RESTS ON TANK TOP
INSIDE TANK COLLAR ON
FIELD BOND JOINT PER
MANUFACTURER'S INSTRUCTIONS
SUMP RESTS ON TOP OF TANK
DISPENSE ISLAND
GALVANIZED PIPE
39
DISPENSER ISLAND
X
46
STAGE 11 VAPOR RECOVERY DROP-OUT TANK
STEEL TANKS
COLLAR ON FIBERGLASS TANKS
47 4" X 2" EXTRACTOR FITTING DPW #233E-4240
NOTE: IF SIPHON IS NOT USED. SIDE ELEVATION
PLUG BUNG WITH 4* MALE PLUG
A
FORM
FINISH MADE
CONNECT TO EXTRACTOR USING 2" STEEL NIPPLE
AND ELBOW FOLLOWEDBY 2' FIBERGLASS
BELL & WALE N.P.T. ADAPTER. CONTINUE
FORM
FINISH GRADE
48
LEAK DETECTION SYSTEMS
WITH FIBERGLASS PIPE TO SUCTION DISPENSER,
49
4"x 3" EXTRACTOR WITH OR WITHOUT BALL FLOAT
z STL. 40
A I PF
X,
NOTE: F BERGALSS ADAPTER MAY CONNECT
OiRECTLY To EXTRACTOR IF SEPARATED
BY 4' FROM MAIN RUN TO DISPENSER
50
(SEE EQUIPMENT LIST)
INTERSTITIAL SENSORS
36' DIM. X 12' DEEP ROUND MANHOLE
2' FIBERGLASS
2"FIBERGLASS
51 COLLAR MOUNT CONTAINMENT SUMP
PRODUCT PIPE 2'x IT/�
BUSHING
4' X 4' 2" TANK SHELL
PRODUCT PIPE
52
FRP COUPLING
cl I
D rl t> I> r� 1>
. .
55
EXTRACTOR FITTING
IN L A
X
53 FITTING ADAPTER MOUNT CONTAINMENT SUMP
X�
*
54
TANK FITTING ADAPTER (SAME MANUFACTURER AS SUMP)
AM 9- SUMP ON SUMP ON
0. ;( �,, 0 -A -
0
2 '. S E L
90 :LB !OW
CONDUI TS
*
55 ENTRY FITTING (SEE NOTE IN PLAN VIEW)
PPM 4000 SYSTEM --- STEEL TANK FG TANK
rr
CONDUITS
55)
55
ACCUMULATOR
MALE N. P . T .
TAW BOTTOM
2 ELL & MALE N.P.T.
FIBERGLASS ADAPTER
*
56
DOUBLE TAPPED BUSHING, 6"X 2"X 2"
PPM 4000 SYSTEM
TRANSDUCER
19-
FIBERGLASS ADAPTER
NOTE: REI'EP '0 PLOT PLAN &
REFER TO PLOT PLAN 30
57
3"POSI-SEAL 150 MODEL A41 SINGLE FLANGE BUTTERFLY VALVE
GROUSE HINDS
42' DIA. SECONDARY GUAM26 J-BOX
CONTAINMENT SUMP OR EQUAL
DISPENSER rOUNDATION DWG.
FOR CORRECT NUIMBER & LOCATION
OF COMD4_ITS AND PRODUCT PIPING.
DISPENSER FOUNDATION DWG.
FOR CORRECT NUMBER & LOCATION
OF CONDUITS AND PRODUCT PIPING.
58
RED JACKET RLM LEVEL CONTROL MONITOR
ASSEIABLY 2' FIBERGLASS
0. 2" FIBERGLASS SIPHON 90' ELBOW
PIPING. SLOPE DOWN PPM 4000 SYSTEM
P I P I N G UNDER DISPENSER
I THOUT
P I P I N G AT TANK
PIPING UNDER DISPENSER
WITH FLEXIBLE CONNECTOR-
59 RED JACKET HIGH LEVEL SENSOR
60 4" X 2" EXTRACTOR BODY, OPW #233-4420
TO LOW POINT CONNECTION 55
CONDUITS
W FLEXIBLE CONNECTOR-
(SUCTION SYSTEM)
AT ADJACENT TANK.
(SEE DETAIL I
(SUCTION SYSTEM)
(SUCTION SYSTEM)
ANY ELEVATION TRANSITION
BETWEEN SUMP AND RUNS TO
ISLANDS TO BE TAKEN UP
NOTE THIS TYPE INSTALLATION RECOMMENDED ONLY WHERE
VERTICAL LIFT DOES NOT EXCEED 10 FT. OR HORIZONTAL
RUN DOES NOT EXCEED 50 FT
NOTE: THIS TYPE INSTALLATION RECOMMENDED ONLY WHERE
VERTICAL LIFT DOES NOT EXCEED 10 FT OR HORIZONTAL
RUN DOES NOT EXCEED 50 FT
A. F,
A
WITHIN THESE TWO FITTINGS
1996 MARATHON OIL COMPANY,
2* STL.
90' ELBOW 15
IF p
FIELD GLASS BOND JOINT PER
MANUFACTURER'S INSTRUCTIONS 2' x 2" X
REDUCING TEE
2' FIBERGLASS
55 ENTRY 90' ELBOW
FITTINGS
LEGEND
Marathon
•
/15dwgs/sl5b.3d
STATE
/
CONDUIT
ISOMETRIC VIEWS
(PUMP POWER)
FIELD GLASS BOND JOINT PER
MANUFACTURER'S INSTRUCTIONS
DETAIL NUMBER
(REFERENCE ONLY NO SCALE)
O ilCompany
SUMP RESTS ON TOP OF TANK
MA RAT H N
L Finday, Ohio 45840
SUMP RESTS ON TANK TOP
INSIDE TANK COLLAR ON
COLLAR ON FIBERGLASS TANKS
TANK SHELL
SHEET WHERE DETAIL APPEARS
I
DRFTR
CHKR
DGNR
RvwR
F ILMD
STEEL TANKS END ELEVATION "B"
NO.
REVISIONS
DATE
DATE
DATE
-DATE
DATE
PUMP & PIPING DETAILS
RAM
JAS
ALR
RAN
UNKNOWN
3/4 '12
MATER I AL L I S T
29
REMOVED " V DEEP ROUND' FORM ITEM -21
9-29-93
9-29-93
9- 30-93
10-5-93
GRAN
10-93
ADDED NOTE TO DETAIL 31TOOLOOSEN TEST COUPLING AND REV.
MI-M
RVD
ALR
& 1 H • P SUBMERSIBLE
PUMP
REFERENCE
3 0
TITLE & CHANGED ITEM - T
2-10-94
2-10-94
2- 8-94
2 -18
SINGLE WALL
3 1
_JAMESBURY
ADDED DEEP SUMP &,ELIMINATED FLEX CONNECTORS
IN DETAILS '3" & 7'; ADDED DETAILS 'g, & '10,
MEB
6-22-94
ALR
6-30-94
RAN
6-30=94
INSTALLATION DETAILS
REFER TO LISTING ON DWG. #i5b
WITH RED JACKET PPM 4000
FIBERGLASS PIPING
32
MISC. MATERIAL LIST UPDATES
RAM
8-29-94
RAM
111-29-94 1
ALR
8-30-94
RAN
- 8-30-94
ELECTRONIC LEAK DETECTION SYSTEM
(WITH PPM 4000)
33
. INDICATED TCI COMPOSITE SUMP, REV PLUMB '"
RAM
RAM
ALR
HAP
I ON L
TYPICAL DEPTH OF BURY, REMOVED FL�X FROM S'4V INE
4-26-95
4-26-95
4-26 95
4-26-95
34
REVISED SED ITEMS *2 & 437. ADDED INTERCOM CONNECTION TO
DETAILS -3. 7 1 11
A . 0 6
RAM
6 -28-95
RAM
6-29-95
ALR
7-13-95
HAF
-1-13-95
!!NOTE!!
CONTAINMENT SUMP TO BE HYDROSTATICLY WATER TESTED
-
35
REMOVED TRANSDUCER CONDUIT FROM.DETAIL 'I
ADDED ITEM 22.TO MATERIAL LIST
ETM
2-1-96
ALR
2-27-96
HAP
SCALE
i"=C-O"OR NOTED
DATE
ILE
NO.
STD
IN PRESENC E OF OWNER'S ENGINEER PER MANUFACTURER'S
SPECIFICATIONS PRIOR TO POURING CONCRETE SLAB.
36
REVISED ITEMS •3, 9 & 49 ON MATERIAL LIST
2- 23 ETM
- 6
ALR -96
2-27
--LL7-16
HA7-P 96
DRFTR
R.A. MOREHART
6-20-89
37
REVISED MATERIAL LIST NOTE AND ADDED SINGLE ASTERISK
RAM
RAM
ALR
-Z:1
HAP
C H K R
BUD.
DGNR
D.A. SCHLAEPPI
9-18-89
DESIGNATION
3-20-96
3-21-96
3-21-96
3-21-96
YR.
38
REVISED ITEMS •15. 16, & 38 AND MOVED ITEM -15e TO ITEM •29
RAM
3-28-96
RAM
3- 8 96
ALR
3-28-96
HAF
6
-3-28-96
RVWR
ARCH [E RHODES
9-18 -89
DWG.
S15b
39
ADDEDE NTRY FITTING NOTE IN DETAIL '1
RAM
4-19-96
Aaf-%jZL
A.
FILMD
1 1
1 NO.
I
i