Loading...
HomeMy WebLinkAbout0825.96.41I 24„ 6.62" N A MATERIALS SCHEDULE ITEM QTY. DESCRIPTION 1 1 HOFFMAN NEMA 1 RATED ENCLOSURE, MODEL #A24N24A (24" X 24" X '- 6.62") WITH INTERIOR MOUNTING PANEL AND LOCKING HANDLE, MODEL #A -L12B 2 1 PER SQUARE D CIRCUIT BREAKER, MODEL #QOU215, 120 1AC, 15 AMP, 2 POLE DISPENSER OTOKHEIM 3 SQUARE D CIRCUIT BREAKER, MODEL 40OU220, 120 VAC, 20-AMP. 2 POLE GILBARC0 1 > WAYNE 1 O4 1 PER SQUARE D GENERAL PURPOSE RELAY, MODEL #RS43VO2, TYPE K, CLASS DISPENSER 8501, 10 AMP, 3 POLE, 120 VAC COIL WITH SNAP MOUNT SOCKET, MODEL #NR43 _ 5O 1 PER SQUARE D DEFINITE PURPOSE CONTACTOR, MODEL #DPA12VO2, CLASS 1 SUBM. PUMP 8910, 20 AMP, 2 POLE, 120 VAC COIL O QUANTITY 1 2 SQUARE D DEFINITE PURPOSE CONTACTOR, MODEL #OPA62V02, CLASS TOKHEIM :!� 5 -5 8910, 60 AMP, 2 POLE, 120 VAC COIL GILBARCO --4 >4 WAYNE --7 -7 O7 AS REQUIRED SQUARE D TERMINAL BLOCK, MODEL #GC6, CLASS 9080, SOLDER•LESS BOX LUG, 60OV, 65 AMP - END BARRIER: MODEL #MFEM6 ; 8O 8 SQUARE D TERMINAL BLOCK END CLAMP, MODEL #MHA10 .• ' 9 AS REQUIRED SQUARE D TERMINAL BLOCK, MODEL #GMG, CLASS 9080, SOLDERLESS BOX LUG, 60OV, 30 AMP - END BARRIER: MODEL #GM68 10 AS REQUIRED SQUARE D STANDARD CHANNEL, MODEL #MH220, CLASS 9080, 35 MM WIDTH ` 11 1 SQUARE D GROUNDING BUS, MODEL #PK9GTA d INSULATOR KIT, MODEL *PKGTAB t, 12 AS REQUIRED PANDUIT 13 AS REQUIRED WIRE - COPPER, THHN OR THWN, SIZED PER NEC TABLE 310 -16 (75 C) 14 15 WIRE TIE CLAMPSy��;`'. 15 AS SHOWN LABELING 16 1 SQUARE D GENERAL PURPOSE RELAY, MODEL #RS44VO2, TYPE K, CLASS 8501, 10 AMP, 4 POLE, 120 VAC COIL WITH SNAP MOUNT SOCKET, MODEL #NR34 CONSTRUCTION ,� ITT; 1. THE MANUFACTURER SHALL PURCHASE ALL ITEMS LISTED IN THE MATERIAL SCHEDULE AND INSTALL IN ACCORDANCE WITH THIS DRAWING, OEM'S INSTRUCTIONS, AND THE NATIONAL ELECTRICAL CODE. ALL CIRCUITS SHALL BE WIRED AS NATIONAL ELECTRICAL CODE CLASS I WIRING (ART. 725). THE DISPENSER MANAGER MUST BE "UL" LISTED AND EACH DISPENSER MANAGER MUST BE LABELED AS SUCH. 2. INDIVIDUAL WIRES SHALL BE INSTALLED BETWEEN THE EMERGENCY STOP CONTACTOR AND EACH 4 s CIRCUIT BREAKER AND BETWEEN EACH GROUND TERMINAL BLOCK AND THE GROUNDING BUS. 3. WIRES MAY BE JUMPERED FROM ONE LOCATION TO ANOTHER FOR THE DISPENSER LIGHTING TERMINAL BLOCKS TO THE DISPENSER LIGHTING CIRCUIT BREAKER AND FOR WIRES M1 -CO, M2-C�, AND M3 -CO. 4. IF THE DISPENSER MANAGER IS BEING MANUFACTURED FOR TOKHEIM DISPENSERS, THREE (3) CIRCUIT BREAKERS ARE REQUIRED FOR DISPENSER LIGHTS. A MAXIMUM OF THREE (3) DISPENSERS CAN BE WIRED TO EACH CIRCUIT BREAKER (FOUR (4) DISPENSERS ARE ALLOWED ON ONE CIRCUIT BREAKER IF TWO OF THE DISPENSERS ARE DIESEL AND KEROSENE). GILBARCO AND WAYNE ONLY REQUIRE ONE (1) CIRCUIT BREAKER FOR DISPENSER LIGHTS. 5. LABEL ALL COMPONENTS AND WIRES AS SHOWN. SUBMERSIBLE PUMP CONTACTORS (PART #DPA12VO2) SHOULD BE LABELED WITH "P1" THROUGH "P4" ONLY. THE PRODUCT LABELS: UNLEADED; MIDGRADE; PREMIUM; DIESEL; & KEROSENE; SHOULD ALL BE CREATED AND PLACED WITHIN THE DISPENSER MANAGER FOR FIELD INSTALLATION. IN ADDITION, A LABEL READING': "DISPENSER MANAGER" SHALL BE PLACED ON THE OUTSIDE OF THE ENCLOSURE DOOR, A FULL LOAD AMPERAGE LABEL SHALL BE INCLUDED ON THE INTERIOR AS WELL AS A UL LISTING LABEL. 6. INSTALL WIRE TIE CLAMPS AS SHOWN FOR MARATHON'S USE DURING FIELD INSTALLATION. 7. ALL TERMINAL BLOCKS, CIRCUIT BREAKERS, AND GENERAL PURPOSE RELAYS SHALL BE MOUNTED TO STANDARD 35 MM DIN -3 RAIL AS SHOWN ON THIS DRAWING. -'a 8. FOR GRAPHICAL REASONS, WIRES P1 -M1 THROUGH P4 -M2 ON THE SUBMERSIBLE PUMP CONTACTORS HAVE NOT BEEN SHOWN. WIRES P1 -M1 THROUGH P4 -M2 SHALL BE CONNECTED TO THEIR RESPECTIVE TERMINAL BLOCKS DIRECTLY ABOVE THE SUBMERSIBLE PUMP CONTACTORS IN xa�< THE DISPENSER MANAGER. 9. EACH DISPENSER MANAGER SHALL BE TESTED TO VERIFY THAT IS HAS BEEN WIRED CORRECTLY.¢ 10. ALL WIRING SHALL BE THWN OR THHN AND SIZED AND COLOR CODED PER THE FOLLOWING { SCHEDULE: DM -L1 d DM -L2: # 6 AWG - RED DM -N1 & DM -N2: # 6 AWG - WHITE DM -GND: # 6 AWG - GREEN r GND - GND10: #10 AWG - GREEN >. LT1H - LT10H: #12 AWG - BROWN y LT1N - LT10N: -12-AWG - GREY �� r LT01H - LT03H: #12 AWG - BROWN LT01N - LT03N: #12 AWG - GREY . ,'•::' L1 - L11: #12 AWG - RED N1 - Nll: #12 AWG - GREY P1-L1 - P4 -L1: 912 AWG - BLACK P1 -L2 - P4 -L2: #12 AWG - BLACK `M r P1-M1 - P4 -M1: #12 AWG - BLACK ` P1 -M2 - P4 -M2: #12 AWG - BLACK ES -CO: #14 AWG - PURPLE N -CO: #14 AWG - WHITE R1H - R9H: #14 AWG - ORANGE R1N - R9N: #14 AWG - GREY M1 -CO A P1 -CO: #14 AWG - BLACK M2 -CO & P2 -CO: #14 AWG - BLUE M3 -CO & P3 -00: #14 AWG - RED M4 -CO $ P4 -CO: #14 AWG - YELLOW MARATHON'S PRODUCT COLOR CODE: REGULAR UNLEADED BLACK MIDGRADE BLUE PREMIUM RED DIESEL YELLOW KEROSENE BROWN „�ti��u�niu„pi A. ,a Q 1995 MARATHON OIL COMPANY ? P GNSTE -i . Q,E. NQ q� •, y , „ • 17486 :. ? /. d/49977 7-18d.3d * e. )TE #3 %o . STATE ,. �[ Marathon Av. ) :*=Y )RIGIN ,,,, )R MARATHON OilCompany " Fr&y. Otio 45M ` r. NO. REVISIONS -WTR CHKR QGNR RVWR L�p DATE DATE DATE 1 5 c ,t ,� D_I SPENSER M-ANAGER�.Y, j ADDED ITEM #16 ETM M MANUFACTURER DRAW I IG x� } - -: t 9 - SCALE HALF SIZE DATE F IL DRFTR R.A. MOREHART CHKR, BUD.. DGNR K.M. MCDANIEL 5 -1 -95 YR.,. y RVWR D. W. FOWLER' 5 -1 -95 DWO fi F ILIuD