HomeMy WebLinkAbout0825.96.42._,.._.._------------------------------------- - - - - -1 I POINT OF SALE - UNIT 'A' AI i nTrm- Lie -r-n flri .T, , r-,., r... -.. POINT OF SALE - UNIT 'B' 1 1 I I i I 1 I I I 1 I I 1 I I I I 1 1 I 1 I INSTALLATION NOTES: o� I. OTHERS SHALL FURNISH, INSTALL, AND WIRE ALL POINT OF SALE (P.O.S.) EQUIPMENT WHERE SHOWN IN DETAIL A. 2. CONTRACTOR SHALL INSTALL TWO (2) JUNCTION BOXES (J -BOX); ONE MOUNTED UNDER THE ATTENDANT COUNTER (LOCATED NEXT TO THE SITE CONTROLLER) AND ONE RECESSED IN THE WALL (MH =36" AFF) LOCATED IN THE OFFICE AT THE DESK. INSTALL ONE (1) 1" CONDUIT BETWEEN THE TWO J -BOXES FOR COMMUNICATION WIRES BETWEEN THE SITE CONTROLLER AND THE OFFICE COMPUTER.. 3. CONTRACTOR SHALL INSTALL AN ISOLATED GROUND SIMPLEX RECEPTACLE (HUBBELL #IG5261 OR EQUAL) FOR EACH POS DEVICE AS SHOWN ON THIS DRAWING. RECEPTACLE FOR RADIO FREQUENCY INVENTORY RECORDER BASE SHALL BE INSTALLED 12" BELOW THE SUSPENDED CEILING IN WALL BEHIND SALES COUNTER. 4. CONTRACTOR SHALL WIRE POS RECEPTACLES TO DEDICATED 120 VAC, 20 AMP CIRCUIT BREAKERS AS FOLLOWS: CIRCUIT 1) POS UNIT 'A' AND THE SITE CONTROLLER, CIRCUIT 2) POS UNIT 'B', THE RADIO FREQUENCY INVENTORY RECORDER BASE, AND THE OFFICE COMPUTER, CIRCUIT 3) (IF APPLICABLE) POS UNIT 'C' AND V. 5. CONTRACTOR SHALL INSTALL JUNCTION BOXES AND CONDUIT WITH PULL STRINGS FOR TELEPHONE LINES; ONE EACH FROM THE SITE CONTROLLER AND OFFICE COMPUTER TO THE PHONE EQUIPMENT AND ONE FROM THE SITE CONTROLLER TO THE RADIO FREQUENCY INVENTORY RECORDER BASE. PHONE LINES SHALL BE PULLED AND WIRED BY OTHERS. NO OTHER WIRES SHALL BE INSTALLED IN THESE CONDUITS EXCEPT TELEPHONE WIRES PER NEC 800 -52, 6. ALL WIRES SHALL BE CONCEALED WITHIN THE COUNTER OR IN A CONDUIT. ALL CONDUITS SHALL BE CONCEALED WITHIN THE SUSPENDED CEILING, WALLS, OR COUNTER, UNLESS SPECIFIED OTHERWISE BY OWNER'S REPRESENTATIVE. CONTRACTOR SHALL INSURE THAT CONDUITS AND RECEPTACLES WITHIN COUNTER DO NOT INTERFERE WITH THE CASH DRAWER INSTALLATION. i 7. ALL ELECTRICAL INSTALLATIONS MUST COMPLY WITH THE NATIONAL ELECTRICAL CODE AND ALL STATE AND LOCAL CODES. 8. IF COUNTERS ARE EXISTING, CONTRACTOR SHALL FURNISH AND INSTALL TWO (2) CABINET DOORS (TO MATCH EXISTING) WHERE SHOWN TO CONCEAL THE SITE CONTROLLER. CABINET DOORS SHALL HAVE A 11/2' X 8 " SLOT AT THE BOTTOM OF EACH CABINET DOOR TO PROVIDE AIR INPUT FOR THE SITE CONTROLLER. IF NEW COUNTERS ARE TO BE INSTALLED, CABINET DOORS SHALL BE FURNISHED WITH CABINETS. 9. IF BUILDING IS A CENTER ISLAND C- STORE, CONTRACTOR SHALL INSTALL ONE (1) 1" CONDUIT BETWEEN THE TWO (2) COUNTERS FOR POS COMMUNICATION WIRES (ASSUMING ONE OR MORE POS UNITS ON EACH SIDE OF THE STORE). 10. CABINET COOLING FAN IS FURNISHED AND INSTALLED BY CABINET VENDOR. CONTRACTOR SHALL PLUG THE FAN INTO A STANDARD 120 VAC RECEPTACLE. IF COUNTERS ARE EXISTING, CONTRACTOR SHALL FURNISH AND INSTALL THE FAN (DAYTON 411/16' SQUARE 55 CFM BLOWER - GRAINGER STOCK •4C548 WITH CORD SET STOCK #4C552 - OR EQUAL). 11. IF AN AUTOMATIC TANK GAUGE IS IN USE, THE CONTRACTOR SHALL INSTALL ONE (1) 1" CONDUIT FROM A J -BOX MOUNTED UNDER THE ATTENDANT COUNTER (NEXT TO THE SITE CONTROLLER ) TO THE AUTOMATIC TANK GAUGE /CONSOLE WITH A PULL STRING. 12. CONTRACTOR SHALL VERIFY THAT A 2" CONDUIT EXISTS FROM THE DISPENSER INTERFACE EQUIPMENT (TYPICALLY IN THE UTILITY ROOM) TO THE ATTENDANT'S COUNTER FOR POS COMMUNICATION WIRES. IF NOT EXISTING, THE CONTRACTOR SHALL INSTALL THE CONDUIT (OVERHEAD = E.M.T. OR UNDERGROUND = PVC). EQUIPMENT LIST >- m co 0 0 LL, REF. —' J J Q NO. OTY DESCRIPTION HEIGHT WIDTH DEPTH Z 1 1 POINT OF SALE SITE CONTROLLER 8" 19" 17" 0 0 2 2 COMPUTER TOUCH SCREEN 13" 14" 18" 0 0 3 2 POINT OF SALE COMPUTER 8" 18" 15" 0 0 4 2 CASH DRAWER 5" 18" 17" 0 0 5 2 CUSTOMER DISPLAY 10" 10" 10" 0 0 6 2 CHANGE MACHINE 14" 14" 7" 0 0 7 2 RECEIPT PRINTER 5" 7" 11" 0 0 8 2 CARD READER (MOUNTED TO SCREEN) 2" 7" 2" 0 0 9 2 BAR CODE SCANNER 8" 5" 5" 0 0 10 4 UNINTERRUPTIBLE POWER SUPPLY 7" 5" 15" 0 0 it 1 JAGUAR FUEL CONTROLLER 2" 5" 6" 0 0 12 1 CURRENT LOOP OR RS485 CONVERTER VARIES VARIES VARIES 0 0 13 1 RADIO FREQUENCY INVENTORY RECORDER BASE 22" 4" 2" 0 0 14 2 LOG PRINTER VARIES VARIES VARIES 0 0 15 1 PC COMPUTER AND MONITOR (OPTIONAL) VARIES VARIES VARIES 0 0 16 1 DAYTON COOLING FAN (GRAINGER CAT. #4C548 /CORD #4C552). 55 CFM, 115 VAC 411/1fi" 411/1fi' 21/2' SEE NOTE #10 17 2 SLOTTED CABINET DOORS - TO MATCH EXISTING COUNTER VARIES VARIES VARIES SEE NOTE #8 18 2 MOUNTING BLOCK FOR COIN CHANGER MACHINE 6" 7" 11" C 0 19 2 MODEM 2'' 7" 7" O 0 20 1 OR 2 DISTRIBUTION BOX OR INTERFACE (MAY BE EXISTING) VARIES VARIES VARIES 0 C R JD CLE 61 �I I I 1 I 1 I 1 I I I 1 I 1 I I I I I I I I TELEPHONE LINES A 4997 -25 IN 0 F-1, o0 PLAN VIEW OF ATTENDANT'S COUNTER t'A` 4997 -25 Ji REAR ELEVATION OF ATTENDANT'S COUNTER SCALE: 3/4' = 1' _Q" © 1996 MARATHON OIL COMPANY �M Marathon MARATHON Oil Company P ' rI 1 std/4997 -25. Findlay, Ohio 45840 10. REVISIONS u"r, 111 I,IIRR VNK KVNK - 1LkIU DATE ATE POINT OF SALE I REDRAWN ON CADD LAP 4-23-93 EQUIPMENT INSTALLATION DETAILS 2 REVISED ALL NOTES AND ADDED CABINET DOORS 5-25-93 LAP 5-26-93 5 -26N 3 3 REVISED NOTES AND OTHER MISC. ITEMS JAS 1 -2- 3 DOD -9 KMM 11-2-93 NAF 4 1994 UPGRADE DDD RAM KMM ALR 4- 4-5-94 4-5-94 4-5-94 5 1995 UPGRADE RLW 6-23 KMM 7-7 -95 HAF 7 -7 -95 6 1996 UPGRADE ETM C M tr s•4 hA A - 96 SCALE AS SHOWN DATE FILE STD DRFTR PUCHTA 4 -23 -93 NO. CHKR K. M. Mc DANIEL 4-20-93 BUD. DGNR R. A. NAL I BORSK I 4 -21-93 YR. RVWR DWG. 4997 -25 FILMD N0.