HomeMy WebLinkAbout0825.96.44t t y - 1 4 F CROUSE HINDS JUNCTION BOX 4 "X4 "X 4" f NOPY COLUMN 1NISH PAVEMENT FOUNDATION TOP OF FIRST — POUR FOR CANOPY FOUNDATIONS JUNCTION BOX FOR FUTURE INTERCOM CROUSE HII JUNCTION 12" X 12" (CONTRACT d INSTALL' ,rte CANOPY COLUMN ND HOLE " CROUSE- HINDS" AN 'AL CONDUIT TO SEAL HEIGHT IDUIT IN ANOTHER COLUMN, 'AN) AVEMENT )UNDATION a v . t � . w • 'A STRUCTURAL PURL IN -------------- -- -------------------------------------- LIGHT FIXTURE BELOW --. 6 6 DECK PANS CONDUIT TO OTHER FIXTURES d J- BOXES CENTER LINE OFF 1 1 FIXTURE LOCATION I 1 1 Qi I • I � CONDUIT TO OTHER PHOTOCELL FIXTURES d J -BOXES STEEL DECK PANS I I CANOPY LIGHTING CONDUIT FROM ANOTHER CANOPY COLUMN. SEE PLOT PLAN FOR ------ LOCATION OF CANOPY COLUMN TO RECEIVE INTERCOM SPEAKER, CANOPY LIGHTING CONDUITS. CANOPY COLUMN , CANOPY SUPPORT GIRDER-----__, PLUG UNUSED THREAD-0-LETS - 1 " THREAD-0-LET" INTERCOM CABLES ARE INSTALLED IN CONDUIT ^� SEPARATE FROM LIGHTING CONDUITS. INTERCOM - CONDUIT FROM CONDUITS SHALL NOT BE MIXED WITH 240V COLUMN TO FIRST J -BQX CIRCUITS. INTERCOM CONDUITS X TO NEXT J -BOX OR CANOPY COLUMN. PARTIAL CANOPY ROOF PLAN IF THREAD -O -LETS ARE 1`I USED, THEY MUST BE CLOSED WITH A PIPE PLUG TO PREVENT WATER FROM ENTERING COLUMN. CONDUIT BRANCHES FROM J -BOX TO J -BOX. 3" TYP. TOP OF FIRST I 1f POUR FOR CANOPY (DARDNAL) INTERCOM WIRES PASS FOUNDATIONS 4" X 4" OPENING IN BASE THROUGH AN EXISTING 1" DIA. PLATE BY CANOPY THREAD-0-LET. THEN ARE ROUTED MANUFACTURER TO THROUGH CONDUITS AS INDICATED ACCOMODATE CONDUITS ABOVE TO OTHER COLUMNS W /INTERCOM SPEAKERS. 1" CONDENSATE DRAIN CONDUIT, TYPICAL ALL COLUMNS BRICK ALTERNATE SECTION "X —X /` D2 D3 DIESEL INTERCOM PHONE 4" X 6" HAND HOLE d FOR ACCESS TO SEAL - -OFFS IN COLUMN MOUNTED DIESEL AU7.75GWLXNI1 5" ONLY )X FUURNRISHEDHBYACANOPY y 8" D WEATHER -PROOF ENCLOSURE (PHONE MANUFACTURER —� AND ENCLOSURE FURNISHED BY OWNER.) ON NOTE • ANDAINTERCOM CANOPY SHOWN, LIGHTING CONDUITS MAY BE INSTALLED IN ANY ONE OF THE SUPPORT BASES. SEE PLOT PLAN FOR NOTATION AS TO WHICH BASE THE THE CONDUITS ARE TO BE INSTALLED IN. IN MOST DISPENSERS, SPEAKERS ARE AN INTERGRAL PART OF THE DISPENSER AND CONTRACTOR SHALL FURNISH AND INSTALL SHIELDED CABLE BETWEEN INTERCOM AND SAID SPEAKERS. SEE PLOT PLAN FOR SPEAKER LOCATION. 3/8" DIA. ;r, °z DRAIN HOL a 0 0 0 m TOP OF FIRST POUR FOR CANOPY FOUNDATIONS l, EQUIPMENT LIST: O ITEM QUANTITY DESCRIPTION FURNISHED BY: INSTALLED BY: 1 1 HONEYWELL xCR7075A LIGHTING CONTROLLER WITH VC7057A1000 CADMIUM SULFIDE PHOTOCELL 0 C 2 1 POWERLINK NETWORK INTERFACE xPLSNI120 -4 WITH POWERLINK SURFACE COVER xPLC4S, FOR SURFACE MOUNT (OR PLC4F, FOR FLUSH MOUNT) 0 C A, AS REQ'D POWERLINK BREAKER MODULE xPLBIM (FOR USE IN ITEM x2; ONE BREAKER MODULE CONTROLS UP TO UP TO 16 BREAKERS DEPENDING ON STAGE ASSIGNMENTS OF BREAKERS) 0 C 4 1 PER PANEL POWERLINK PARTITION KIT xPLPK4 (FOR USE IN DISTRIBUTION PANEL) t t y - 1 4 F CROUSE HINDS JUNCTION BOX 4 "X4 "X 4" f NOPY COLUMN 1NISH PAVEMENT FOUNDATION TOP OF FIRST — POUR FOR CANOPY FOUNDATIONS JUNCTION BOX FOR FUTURE INTERCOM CROUSE HII JUNCTION 12" X 12" (CONTRACT d INSTALL' ,rte CANOPY COLUMN ND HOLE " CROUSE- HINDS" AN 'AL CONDUIT TO SEAL HEIGHT IDUIT IN ANOTHER COLUMN, 'AN) AVEMENT )UNDATION a v . t � . w • 'A STRUCTURAL PURL IN -------------- -- -------------------------------------- LIGHT FIXTURE BELOW --. 6 6 DECK PANS CONDUIT TO OTHER FIXTURES d J- BOXES CENTER LINE OFF 1 1 FIXTURE LOCATION I 1 1 Qi I • I � CONDUIT TO OTHER PHOTOCELL FIXTURES d J -BOXES STEEL DECK PANS I I CANOPY LIGHTING CONDUIT FROM ANOTHER CANOPY COLUMN. SEE PLOT PLAN FOR ------ LOCATION OF CANOPY COLUMN TO RECEIVE INTERCOM SPEAKER, CANOPY LIGHTING CONDUITS. CANOPY COLUMN , CANOPY SUPPORT GIRDER-----__, PLUG UNUSED THREAD-0-LETS - 1 " THREAD-0-LET" INTERCOM CABLES ARE INSTALLED IN CONDUIT ^� SEPARATE FROM LIGHTING CONDUITS. INTERCOM - CONDUIT FROM CONDUITS SHALL NOT BE MIXED WITH 240V COLUMN TO FIRST J -BQX CIRCUITS. INTERCOM CONDUITS X TO NEXT J -BOX OR CANOPY COLUMN. PARTIAL CANOPY ROOF PLAN IF THREAD -O -LETS ARE 1`I USED, THEY MUST BE CLOSED WITH A PIPE PLUG TO PREVENT WATER FROM ENTERING COLUMN. CONDUIT BRANCHES FROM J -BOX TO J -BOX. 3" TYP. TOP OF FIRST I 1f POUR FOR CANOPY (DARDNAL) INTERCOM WIRES PASS FOUNDATIONS 4" X 4" OPENING IN BASE THROUGH AN EXISTING 1" DIA. PLATE BY CANOPY THREAD-0-LET. THEN ARE ROUTED MANUFACTURER TO THROUGH CONDUITS AS INDICATED ACCOMODATE CONDUITS ABOVE TO OTHER COLUMNS W /INTERCOM SPEAKERS. 1" CONDENSATE DRAIN CONDUIT, TYPICAL ALL COLUMNS BRICK ALTERNATE SECTION "X —X /` D2 D3 DIESEL INTERCOM PHONE 4" X 6" HAND HOLE d FOR ACCESS TO SEAL - -OFFS IN COLUMN MOUNTED DIESEL AU7.75GWLXNI1 5" ONLY )X FUURNRISHEDHBYACANOPY y 8" D WEATHER -PROOF ENCLOSURE (PHONE MANUFACTURER —� AND ENCLOSURE FURNISHED BY OWNER.) ON NOTE • ANDAINTERCOM CANOPY SHOWN, LIGHTING CONDUITS MAY BE INSTALLED IN ANY ONE OF THE SUPPORT BASES. SEE PLOT PLAN FOR NOTATION AS TO WHICH BASE THE THE CONDUITS ARE TO BE INSTALLED IN. IN MOST DISPENSERS, SPEAKERS ARE AN INTERGRAL PART OF THE DISPENSER AND CONTRACTOR SHALL FURNISH AND INSTALL SHIELDED CABLE BETWEEN INTERCOM AND SAID SPEAKERS. SEE PLOT PLAN FOR SPEAKER LOCATION. 3/8" DIA. ;r, °z DRAIN HOL a 0 0 0 m TOP OF FIRST POUR FOR CANOPY FOUNDATIONS l, EQUIPMENT LIST: O ITEM QUANTITY DESCRIPTION FURNISHED BY: INSTALLED BY: 1 1 HONEYWELL xCR7075A LIGHTING CONTROLLER WITH VC7057A1000 CADMIUM SULFIDE PHOTOCELL 0 C 2 1 POWERLINK NETWORK INTERFACE xPLSNI120 -4 WITH POWERLINK SURFACE COVER xPLC4S, FOR SURFACE MOUNT (OR PLC4F, FOR FLUSH MOUNT) 0 C 3 AS REQ'D POWERLINK BREAKER MODULE xPLBIM (FOR USE IN ITEM x2; ONE BREAKER MODULE CONTROLS UP TO UP TO 16 BREAKERS DEPENDING ON STAGE ASSIGNMENTS OF BREAKERS) 0 C 4 1 PER PANEL POWERLINK PARTITION KIT xPLPK4 (FOR USE IN DISTRIBUTION PANEL) 0 C 5 AS REO'D POWERLINK 20 AMP, 1 POLE BREAKER x00120PL (FOR USE IN DISTRIBUTION PANEL) 0 C 6 AS REQ'D POWERLINK 20'AMP, 2 POLE BREAKER x00220PL (FOR USE IN DISTRIBUTION PANEL) 0 C 7 AS REQ'D POWERLINK 30 AMP, 1 POLE BREAKER x00130PL (FOR USE IN DISTRIBUTION PANEL) 0 C 8 1 REMO LIGHT[NC CONTROL CONSISTING OF 'S D" CLASS x9001, TYPE xK26, 2 UNIT FLUSH PLATE WITH CLASSY x9001 TYPE �KS43 OPERATORS, 2 CLASS 09001 TYPE xKA-'1 CONTACT BLOCKS, 2 CLASS x9001 TYPE xKN -300 LEGEND PLATES ENGRAVED "ON -OFF- AUTO" ON SECOND LINE OF BOTH, "LIGHTING CONTROL 1" ON THE FIRST LINE OF ONE AN� 'LIGHTING CONTROL 2': ON THE FIRST LINE OF THE OTHER 0 C T DO NOT CUT THROUGH ANY STRUCTURAL MEMBERS. THREAD-O -LETS ARE SUPPLIED SO THAT IT IS NOT NECESSARY TO CUT INTO COLUMNS. SUPPORT GIRDER WIRE NUT POWER LINK LIGHTING m o ,-CANOPY � �m B2 3 IcE GROUND i 4, Ln COMMON .9!'{, \STIR s ° o 120V AC / 1" DIA. THREAD -O -LET WELDED TO EACH W � J RIB L- - < A. GENERAL NOTES: • 6. BREAKER INTERFACE MODULE CHANNEL OUTPUTS WIRED TO PL CIRCUIT I. ONE INTERCOM( SPEAKER SHALL BE INSTALLED PER ISLAND, (UNLESS SPECIFIED WIi BREAKERS FOR ONE HALF OF THE CANOPY LIGHTS AND ALL SIGNAGE SHALL RTB OTHERWISE. CONTRACTOR 15 RESPONSIBLE FOR WIRING CONNECTIONS AT BOTH ENDS OFF 5 ON BE WIRED TO STAGE I. CHANNEL OUTPUTS WIRED TO PL CIRCUIT THE CANOPY LIGHTS, THE BUILDING! OFF T ON (SEE DRAWING 05011-1 OA AND MANUFACTURER'S INSTRUCTIONS). SEE PLOT PLAN A2 I BREAKERS FOR THE SECOND HALF OF CIRCUIT BREMER FOR INTERCOM CONTROL LOCATION IN BUILDING. POWER SUPPLY SOFFIT LIGHTS, AND AREA LIGHTS SHALL BE WIRED TO STAGE It. SEE WHIT PLATE (CORNERS SHALL BE ROUNDED OFF) WHICH SHALL BE WELDED TO THE ' CONDUIT FROM CANOPY UMN WITH CANOPY L PHOTOCELL [N B7 I BUILDING DRAWINGS FOR AN ELECTRICAL PANEL SCHEDULE AND MORE 0 0 •24V DC •SV DC DISPENSER MOUNTED INTERCOM SPEAKERS: CONTRACTOR SHALL FURNISH AND INSTALL ,3 DETAILS. x ONE (1) 3/4' CONDUIT AND WIRE 1018 AVG, TWO PAIR, TWISTED, SHIELDED CABLE) FROWN BUILDING TEi DISPENSER INTERCOM SPEAKER (SPEAKER INSTALLED BY OEM). T CONTRACTOR SHALL INSTALL THE HONEYWELL PHOTOCELL ON TOP OF THE POWER LINK BOTH ENDS PER EACH MANUFACTURER'S INSTRUCTIONS. CANOPY, MOUNTED HORIZONTALLY TO A WEATHERPROOF JUNCTION SOX. - CANOPY COLUMN MOUNTED INTERCOM SPEAKERS: CONTRACTOR SHALL FURNISH AND ,. SENSOR SHALL BE POINTING NORTH AND THE LIGHT LENS FACING UP-. INSTALL ONE (1) 1" CONDUIT AND WIRE ISAME AS DISPENSER MOUNTED INTERCOM VERIFY THAT THE AREA IN WHICH THE PHOTOCELL IS BEING INSTALLED -► 'A' SPEAKERS) AS SHOWN IN DETAIL "A" ON THIS SHEET. DOES NOT BECOME SHADED THROUGHOUT THE DAY. SEE DETAIL ON TO L IGHT F I XTURE ( TYPICAL 1 I THIS DRAWING AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. NOTE: IF A NORTHERN TELECOM "NORSTAR' PHONE SYSTEM IS TO BE INSTALLED, "D' C. LIGHTING CONTROLLER START-UP NOTES: SEE NOTES IN SECTION FOR INSTALLATION INSTRUCTIONS AND DISREGARD THE ABOVE NOTES. 1. VERIFY THAT ALL WIRING HAS BEEN INSTALLED PER THIS DRAWING AND 2. ALL JUNCTION BOXES AND FITTINGS SHALL BE FURNISHED AND INSTALLED BY MANUFACTURER'S INSTRUCTIONS. TURN THE POWER ON TO BOTH THE CONTRACTOR AND SHALL BE OF THE WEATHERPROOF TYPE. Y 1 POWERLINK AND HONEYWELL LIGHTING CONTROLLERS. VERIFY THAT THE GREEN LED LIGHT IN THE HONEYWELL UNIT AND BOTH RED LED LIGHTS IN 3. ALL UNDERGROUND CONDUITS SHALL BE GALVANIZED RIGID CONDUIT. ALL THE POWERLINK UNIT (LOCATED ON THE POWER SUPPLY MODULE) ARE ON. clRCUIT ABOVEGROUND CONDUITS SHALL BE INTERMEDIATE METAL CONDUIT OR RIGID NON- METALLIC PLASTIC (SCHEDULE 40 AND 80 PVC CONDUIT) THAT IS RESISTANT TO LOW 2. VERIFY THAT LED STATUS INDICATOR LIGHTS ON THE BREAKER INTERFACE TEMPERATURE CRACKING AND SUNLIGHT. MODULE ARE ON FOR ALL CHANNELS. IF THE LED LIGHTS ARE OFF OR LINK SWITCH _ SWITCH -- FLASHING, PRESS THE TOGGLE SWITCH UP UNTIL THE LED LIGHTS ARE ON. 4. REFER TO APPROPRIATE CANOPY LIGHTING LAYOUT DRAWING FOR CONDUIT SIZES AND 3, PLACE ALL POWERLINK CIRCUIT BREAKERS IN THE 'ON' POSITION. NEXT, 114" ALL THREAD, 4 PER LIGHT, i CIRCUIT DESIGNATIONS. CIR UWITBREMER SWITCH THE STAGE I AND STAGE 11 LIGHTING CONTROLLER SWITCHES INTO B. LIGHTING CONTROLLER INSTALLATION NOTES: r THE 'AUTO' POSITION. 1. LIGHTING CONTROLLER SYSTEM CONSISTS OF; 1) SQUARE D POWERLINK 4. THE HONEYWELL LIGHTING CONTROLLER IS NOW READY FOR CALIBRATION. LIGHTING CONTROLLER PANEL WITH A POWER SUPPLY MODULE AND ONE (1) THE CONTRACTOR IS RESPONSIBLE FOR CALIBRATING THE STAGE 1 AND OR MORE BREAKER INTERFACE MODULES, 2) POWERLINK ( PL) CIRCUIT STAGE 11 LIGHTING LEVELS OF THE HONEYWELL LIGHTING CONTROLLER BREAKERS, 3) PARTITION KIT, 4) HONEYWELL TWO STAGE LIGHTING CAULKING. LIGHT FIXTURE (FURN. BY OWNER) SEE CANOPY ( ACCORDING TO THE FOLLOWING INSTRUCTIONS PRIOR TO PROJECT CONTROLLER AND PHOTOCELL, AND 5 ) TWO (2)SQUARE D REMOTE COMPLETION: LIGHTING CONTROL SWITCHES. ALL ITEMS SHALL BE FURNISHED BY OWNER LIGHTING LAYOUT FOR NUMBER REQUIRED. I A. ON THE HONEYWELL CONTROLLER, ADJUST BOTH LIGHT LEVEL CIRCUIT POUT LINK BREAKER AND INSTALLED BY CONTRACTOR. 4. POTENTIOMETERS TO THEIR FULL CLOCKWISE POSITION. 2. CONTRACTOR SHALL INSTALL THE POWERLINK AND HONEYWELL LIGHTING a B. PLACE THE SET -RUN SWITCH TO THE RUN POSITION. OPTIONAL INTERCOM SPEAKER (FURN. CONTROLLERS NEAR THE ELECTRICAL DISTRIBUTION PANELS. SOME T. 0.0. 1 I 1 SET RUN ASSEMBLY OF THE POWERLINK LIGHTING CONTROLLER PANEL IS REQUIRED. .1 y C. AT THE DESIRED OUTDOOR LIGHTING LEVEL FOR STAGE I (AT DUSK). ` THE WIRING SCHEMATIC SHOWN IS FOR A GENERIC SITE. WIRE PER THIS BY OWNER; NUMBER d ORIENTATION AS I PLACE THE SET -RUN SWITCH TO THE SET POSITION. DRAWING AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. VERIFY c�iRACUH MOUNTING LOCATION WITH OWNER'S REPRESENTATIVE. r t �- +- +'•: Vii. #r:., D. SLOWLY ROTATE THE STAGE I LIGHT LEVEL POTENTIOMETER 3. INSTALL PL CIRCUIT BREAKERS IN THE ELECTRICAL DISTRIBUTION PANELS - COUNTERCLOCKWISE UNTIL THE STAGE I LED LIGHT TURNS ON. THE AND WIRE TO THE BREAKER INTERFACE MODULE CHANNEL PER STAGE I LIGHT LEVEL IS NOW CALIBRATED. RETURN THE SET -RUN MANUFACTURER'S INSTALLATION INSTRUCTIONS. EW PL - CIRCUIT (OPTIONAL) I SWITCH TO THE RUN POSITION. POWER LINK C[RCU[1 BREAKER BREAKER'S CONTROL WIRING (APPROX. 18" LONG FROM1 FACTORY) IS 1 E. AT THE DESIRED DARKNESS FOR STAGE 11 (APPROXIMATELY 1/2 HOUR CONSIDERED CLASS 1 AND MUST BE INSTALLED IN ACCORDANCE WITH NEC AFTER DUSK), PLACE THE SET -RUN SWITCH TO THE SET POSITION. ARTICLE 725. ALL WIRING FOR CLASS 1 CIRCUITS MUST HAVE INSULATION (BRANCH RATED FOR 600 VOLTS (SEE NEC SECTION 725-15). CONTRACTOR SHALL F. SLOWLY ROTATE THE STAGE [I LIGHT LEVEL POTENTIOMETER GRFX SERIES xGRFX119 W/ GASKET NGASK643 1 2 INSTALL THE PARTITION KIT TO SEPARATE THE CLASS 1 CIRCUITS FROM AC ICIRCUIT COUNTERCLOCKWISE UNTIL THE STAGE II LED LIGHT TURNS ON. THE WIRING IN THE ELECTRICAL DISTRIBUTION PANELS. OR APPROVED EQUAL. CONTRACTOR TO CUT I STAGE II LIGHT LEVEL IS NOW CALIBRATED. RETURN THE SET -RUN 4. A MAXIMUM OF TWO (2) PL CIRCUIT BREAKERS CAN BE WIRED TO EACH SWITCH TO THE RUN POSITION. BREAKER INTERFACE MODULE CHANNEL. EACH BREAKER INTERFACE POWER LINK MODULE HAS EIGHT (8) CHANNELS ALLOWING A MAXIMUM OF SIXTEEN (16) r SHIELDED CABLE. ( CIRCUIT BREAKERS TO BE WIRED TO EACH BREAKER INTERFACE MODULE. CIRCUIT BREAKER THE POWERLINK LIGHTING CONTROLLER PANEL CAN HOLD UP TO FOUR (4) I BREAKER INTERFACE MODULES. 5. CONTRACTOR SHALL INSTALL THE REMOTE LIGHTING CONTROL SWITCHES —1" SEAL @ HAND HOLE " CROUSE- HINDS" TYPE "EYS" NEAR THE ATTENDANT COUNTER. THE SWITCHES SHALL BE WIRED TO THE HONEYWELL LIGHTING CONTROLLER OUTPUTS AND TO THE BREAKER 1" RIGID METAL CONDUIT TO SEAL HEIGHT I D2 INTERFACE MODULE CHANNEL OUTPUTS AS SHOWN ON THIS DRAWING. ALL CIRCUIT BREAKER I FIELD CLASS WIRING FOR THE SWITCHES IS CONSIDERED CLASS 2 AND MUST BE ° (LIGHTING CONDUIT IN ANOTHER COLUMN, I INSTALLED IN ACCORDANCE WITH NEC ARTICLE 725. I 1 SUPPORT GIRDER WIRE NUT POWER LINK LIGHTING m o ,-CANOPY � �m B2 3 IcE GROUND i 4, Ln COMMON .9!'{, \STIR s ° o 120V AC / 1" DIA. THREAD -O -LET WELDED TO EACH W � J RIB L- - < SIDE OF COLUMN BY CANOPY MANUFACTURER. -- — — — — — — — — — - BRANCH F-- a U PLUG ALL UNUSED THREAD-0-LETS. " PROOF HUB COVER I w O J WIi N W RTB oZ OFF 5 ON OFF 6 ON OFF T ON BLACK A2 I PHONE LOCATION BY AN ELECTRICIAN.. , CIRCUIT BREMER 3. CONTRACTOR MOUNT -PROOF ENCLOSURE TO A 11' V,X 15" H STEEED� POWER SUPPLY POWER LINK WHIT PLATE (CORNERS SHALL BE ROUNDED OFF) WHICH SHALL BE WELDED TO THE ' CONDUIT FROM CANOPY UMN WITH CANOPY L PHOTOCELL [N B7 I COLUMN. PAINT PLATE LIGHT GREY TO MATCH CANOPY COLUMN. 0 0 •24V DC •SV DC 4. INSTALL ONE (1) 3/4' UNDERGROUND CONDUIT FROM BUILDING PHONE EQUIPMENT ,3 BRANCH Imo, x DISPENSER WIRING DRAWINGS. INSTALL ONE (1) CABLE (x18 GAUGE. TWO PAIR, / HTING Co NDUITS. ROOF ENCLOSURE TWISTED. AND SHIELDED) TO EACH DISPENSER FROM "NORSTAR' SYSTEM AND WIRE AT POWER LINK BOTH ENDS PER EACH MANUFACTURER'S INSTRUCTIONS. PLOT PLAN) LUN STRUCTURAL PURLIN ,. CIRCUIT AND MAKE ALL WIRING CONNECTIONS. 1 /2" CONDU I T BRANCHES FROM J -BOX I j 1BRANU "T PRIOR TO TELEPHONE START -UP. TO L IGHT F I XTURE ( TYPICAL 1 I BLACK ALVAN I ZED 2 X 2 X 1 /8 ANGLE I CIRCUUIT BREAKER WH r PER L I GH T IBRANCH Y 1 STEEL DECK PANS I 85 clRCUIT STAGE I STAGE i[ TWO (2) GANG BOX FURNISHED O CONTROLLER CONTROLLER NEAR ATTENDANT AREA LINK SWITCH _ SWITCH -- F OFF = r = OFF 1 (AUTO ON I (AUTO ON I I 114" ALL THREAD, 4 PER LIGHT, i , g � � I -o CIR UWITBREMER J o I c, TERMINAL STRIP r - - - — - — - - — — - — - — - � SEAL CONDUIT d BOLT DOUBLE NUT BOTH ENDS. LL OPENINGS WITH SILICON I ICIRCUIT FIELD WIRED 3/4" CONDUITS " N 3/4 CO DU ITS CAULKING. LIGHT FIXTURE (FURN. BY OWNER) SEE CANOPY ( BLACK INTERIOR BARRIERS _ LIGHTING LAYOUT FOR NUMBER REQUIRED. I REINSTALL PRIOR I CIRCUIT POUT LINK BREAKER 1 TO ENERGIZING UNIT—­-z 4. OUTPUT OUTPUT STAGE I STAGE II_ R - - - -- ---- U--- - - - - - -- a SET -RUN SWITCH. OPTIONAL INTERCOM SPEAKER (FURN. T. 0.0. 1 I 1 SET RUN r.0.D.1 O O 2 T.O.D. 2 .1 y T.O.D. 2 L1D6 4 STAGE I STAGE II ` O FIELD WIRED LIOT BY OWNER; NUMBER d ORIENTATION AS I PHOTO CELL c�iRACUH FOR INSTALLATION) CONTROLLER r t �- +- +'•: Vii. #r:., SHOWN ON PLOT PLAN) - CHANNEL OUTPUTS (OPTIONAL) I POWER LINK C[RCU[1 BREAKER 1 SPEAKER MTG. BOX TO BE " CROUSE- HINDS" A2 I (BRANCH GRFX SERIES xGRFX119 W/ GASKET NGASK643 1 2 ICIRCUIT OR APPROVED EQUAL. CONTRACTOR TO CUT I BLACK 3/4" HOLE IN COLUMN d BACK OF BOX FOR POWER LINK r SHIELDED CABLE. ( CIRCUIT BREAKER I IQRCUIT —1" SEAL @ HAND HOLE " CROUSE- HINDS" TYPE "EYS" 1" RIGID METAL CONDUIT TO SEAL HEIGHT I D2 CIRCUIT BREAKER I FIELD CLASS WIRED 1 CIRCUITS ° (LIGHTING CONDUIT IN ANOTHER COLUMN, I I 1 CONDUIT (MINIMUM) SEE PLOT PLAN) ul I I ° CANOPY COLUMN L - -- - - - - - - - - -J o MAIN DISTRIBUTION PANEL FINISH PAVEMENT 0 m CANOPY FOUNDATION 4" X 4" OPENING IN BASE PLATE BY CANOPY MANUFACTURER TO ACCOMODATE CONDUITS �1" CONDENSATE DRAIN CONDUIT, TYPICAL ALL COLUMNS SECTION "X —X" DETAIL "A" CANOPY LIGHTING & INTERCOM MOUNTING DETAILS 1 0 1/2' CONDUIT TO PHOTOCELL- 3/4" CONDUIT FOR POWER—) POWERLINK LIGHTING CONTROLLER 1" CONDUIT O ELECTRICAL ELECTRICAL DISTRIBUTION DISTRIBUTION PANEL PANEL = -1 Y z WIRE NUT POWER LINK LIGHTING m o CONTROLLER � �m B2 3 IcE GROUND - 4, Ln COMMON .9!'{, \STIR s ° o 120V AC 17486 W � J RIB L- - < �. �z OFF 1 ON F-- a U OFF 3 ON w O J R58 N W RTB oZ OFF 5 ON OFF 6 ON OFF T ON OFF 8 N POWER SUPPLY MODULE- PHONE LOCATION BY AN ELECTRICIAN.. , 3. CONTRACTOR MOUNT -PROOF ENCLOSURE TO A 11' V,X 15" H STEEED� POWER SUPPLY POWER LINK PLATE (CORNERS SHALL BE ROUNDED OFF) WHICH SHALL BE WELDED TO THE COLUMN. PAINT PLATE LIGHT GREY TO MATCH CANOPY COLUMN. 0 0 •24V DC •SV DC 4. INSTALL ONE (1) 3/4' UNDERGROUND CONDUIT FROM BUILDING PHONE EQUIPMENT ,3 1/2' CONDUIT TO LIGHTING CONTROLLER SWITCHES HONEYWELL LIGHTING CONTROLLER r—LED LIGHTS B4 TOGGLE SWITCHES ADDITIONAL BREAKER BREAKER INTERFACE MODULE INTERFACE MODULES AS REQUIRED (FOUR (4) MAXIMUM) POWERLINK /HONEYWELL LIGHTING CONTROLLER WIRING DETAIL /M\ Marathon PLBIM SERIES 2 0 0 0 1 o 2 3 4 0 OF F 0 0 BREAKER I/F MODULE 0 0 0 0 5 D 0 0OF o D, NONE SYSTEM AND INTERCOMS (AT ENRO TRUCK STOP LOCATIONS)s .9!'{, \STIR s 1. CONTRACTOR SHALL INSTALL NORTHERN TELECOM "NORSTAR" PHONE SYSTEM MNE(NE 17486 SHOWN ON BUILDING ELECTRICAL DRAWINGS. ALL STORE TELEPHONES, TRUCK RIB I R2B R3B R4B OFF 1 ON OFF 2 ON OFF 3 ON OFF 4 OON R58 % RTB R8B OFF 5 ON OFF 6 ON OFF T ON OFF 8 N PHONE LOCATION BY AN ELECTRICIAN.. , B4 TOGGLE SWITCHES ADDITIONAL BREAKER BREAKER INTERFACE MODULE INTERFACE MODULES AS REQUIRED (FOUR (4) MAXIMUM) POWERLINK /HONEYWELL LIGHTING CONTROLLER WIRING DETAIL /M\ Marathon D, NONE SYSTEM AND INTERCOMS (AT ENRO TRUCK STOP LOCATIONS)s .9!'{, \STIR s 1. CONTRACTOR SHALL INSTALL NORTHERN TELECOM "NORSTAR" PHONE SYSTEM MNE(NE 17486 SHOWN ON BUILDING ELECTRICAL DRAWINGS. ALL STORE TELEPHONES, TRUCK 0'. STATE OF FUELING LANE TELEPHONES. AND INTERCOMS SHALL BE WIRED TO THE 'NORSTAII' E, O►AN SYSTEM. , jt 2. INSTALL ONE (1) NORTHERN TELECOM PHONE IN A WEATHER-PROOF ENCLOSURE ON` 4 CANOPY COLUMN AT EACH FUELING LANE (PHONE AND ENCLOSURE SUPPLIED BY OMNER). INSTALL ONE (1) 1' UNDERGROUND CONDUIT FROM BUILDING PHONE EQUIPMENT LOCATION TO FIRST CANOPY COLUMN WITH A PHONE AND DAISY-CMAr r �< CONDUIT OVERHEAD FROM FIRST LOCATION TO THE REMAINING LOCATIONS. ON (4'�" " T STANDARD FOUR CONDUCTOR (18 GAUGE) PHONE CABLE SHALL BE INSTALLLO TO EAClk_, .' PHONE LOCATION BY AN ELECTRICIAN.. , 3. CONTRACTOR MOUNT -PROOF ENCLOSURE TO A 11' V,X 15" H STEEED� SHALL WEATHER PLATE (CORNERS SHALL BE ROUNDED OFF) WHICH SHALL BE WELDED TO THE COLUMN. PAINT PLATE LIGHT GREY TO MATCH CANOPY COLUMN. 4. INSTALL ONE (1) 3/4' UNDERGROUND CONDUIT FROM BUILDING PHONE EQUIPMENT ,3 LOCATION TO EACH DISPENSER PER PLOT PLAN, DISPENSER FOOTPRINT. AND x DISPENSER WIRING DRAWINGS. INSTALL ONE (1) CABLE (x18 GAUGE. TWO PAIR, { ". TWISTED. AND SHIELDED) TO EACH DISPENSER FROM "NORSTAR' SYSTEM AND WIRE AT f BOTH ENDS PER EACH MANUFACTURER'S INSTRUCTIONS. 5. INSTALL CONDUITS AND STANDARD PHONE CABLE TO STORE TELEPHONE RECEPTACLE ,. LOCATIONS WITHIN BUILDING WHERE SHOWN ON THE BUILDING ELECTRICAL DRAWINGS AND MAKE ALL WIRING CONNECTIONS. 6. CONTRACTOR SHALL INSURE THAT ALL WIRING CONNECTIONS ARE MADE CORRECTLY PRIOR TO TELEPHONE START -UP. ' �;•,� i Y 1 85 STAGE I STAGE i[ TWO (2) GANG BOX FURNISHED LIGHTING LIGHTING BY CONTRACTOR. INSTALLED CONTROLLER CONTROLLER NEAR ATTENDANT AREA SWITCH _ SWITCH -- F OFF = r = OFF 1 (AUTO ON I (AUTO ON I I , g � � I -o J o I c, TERMINAL STRIP r - - - — - — - - — — - — - — - � (- LL FIELD WIRED CLASS 2 CIRCUITS FIELD WIRED 3/4" CONDUITS " N 3/4 CO DU ITS INTERIOR BARRIERS _ REINSTALL PRIOR I 1 TO ENERGIZING UNIT—­-z 4. OUTPUT OUTPUT STAGE I STAGE II_ - - - -- ---- U--- - - - - - -- a SET -RUN SWITCH. T. 0.0. 1 I 1 SET RUN r.0.D.1 O O 2 T.O.D. 2 .1 y T.O.D. 2 L1D6 4 STAGE I STAGE II ` O FIELD WIRED LIOT PHOTO CELL (SEE DETAIL A 87 B2 C4 HONEYWELL L IGH ING FOR INSTALLATION) CONTROLLER r t �- +- +'•: Vii. #r:., - CHANNEL OUTPUTS B4 TOGGLE SWITCHES ADDITIONAL BREAKER BREAKER INTERFACE MODULE INTERFACE MODULES AS REQUIRED (FOUR (4) MAXIMUM) POWERLINK /HONEYWELL LIGHTING CONTROLLER WIRING DETAIL /M\ Marathon '61 MARATHON F- WM�oy, 45M { ' No. REVISIONS RA AR MAC CANOPY AND AREA LIGHTING- Z` s YF 1 INCLUDED INSTALLATION NOTES _ tom'. EQUIPMENT LAYOUT.-DETAIL 2 CLARIFICATIDNREVISIOlS - - 26- -D� AND - INTERCOM DETAILS t s AMC D DETAIL NORSTAR PHONE OLE KIM RAN •a? %�k Z 3 INSTALLATION AND SECTION •D• s. _,Jz - POWERLINK CONTROL C I RCI�' ., r -{ x 4 REVISED LIGHTING CONTROLLER DETAIL AND NOTE SECTIONS D i C. n 1 5 ADDED EQUIPMENT LIST M ET NOTE: DO NOT i NSTA L PHOTOCELL CONTROL EQUIPMENT t o� E NONE CHTHTA *5 -92 NO. CH ARCHIE InES 10-9ft r UNLESS SPECIFICALLY DIRECTED ON PLOT PLAN • oc M.A. CRAMS to-a-92 ' RVWR F ILMD t N 0 + .. . ♦ � ` ' � < � , :st . ?� b�y i� 6 1. ay l �4 .9!'{, \STIR s fib\ 17486 0'. STATE OF E, O►AN I , jt © 1995 MARATHON 0[L COMPANY ��'' ,,,,,Ott``` tiI� 4 STD /5011 /50111OB.DON' '61 MARATHON F- WM�oy, 45M { ' No. REVISIONS RA AR MAC CANOPY AND AREA LIGHTING- Z` s YF 1 INCLUDED INSTALLATION NOTES _ tom'. EQUIPMENT LAYOUT.-DETAIL 2 CLARIFICATIDNREVISIOlS - - 26- -D� AND - INTERCOM DETAILS t s AMC D DETAIL NORSTAR PHONE OLE KIM RAN •a? %�k Z 3 INSTALLATION AND SECTION •D• s. _,Jz - POWERLINK CONTROL C I RCI�' ., r -{ x 4 REVISED LIGHTING CONTROLLER DETAIL AND NOTE SECTIONS D i C. n 1 5 ADDED EQUIPMENT LIST M ET NOTE: DO NOT i NSTA L PHOTOCELL CONTROL EQUIPMENT t o� E NONE CHTHTA *5 -92 NO. CH ARCHIE InES 10-9ft r UNLESS SPECIFICALLY DIRECTED ON PLOT PLAN • oc M.A. CRAMS to-a-92 ' RVWR F ILMD t N 0 + .. . ♦ � ` ' � < � , :st . ?� b�y i� 6 1. ay l �4