Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0825.96.8
�Tp�o'ry��5 A'�PE G AS qOX 4T�.�F 2 i Of t0 GO S r ALL G £� B£ LIT £fly oolR o Ur �� I� oo L 2£ LPR LK;IJ pL R cf p fo AL. �R��RIp P DETAIL Ct_ REV.1 4/6/90 24 GA. HAT SEf:TION \ DECKING TEK SCPE`NS cy -- — -J CONTINUOUS BEAD OF CAULKING I � / 4 1/2' \ 1 2' PERIMETER GUTTER 7 / ENCLOSURE —{ 3, TACk �� Nq�N T Tee S FR PA THAT Zp 3p�Ri 3 p� RIFTS CIS TS IN Bp�� q��al NOTE: APPLY SILPRUF CAULKING TO THE GUTTER DRAIN LIP & ATTACH TO GUTTER WHILE CAULK IS STILL WET. THIS WILL ALLOW CAULKING TO COVER THE SCREW THREADS FOR AN APPROPRIATE SEAL. 24 GA. HAT SECTION -- RUBBER PIPE SLEEVE F;LI0 CUT HOLE IN � Pfi Fa'.IETER GUTTER DECKING 'Oe. 1 — - - A l- PVC. DRAIN LEADER FROM TOP SIDE OF CANOPY APPLY SILPRUF -_- - - CAULK TO ALL GUTTER - -� BOTTOM SCREW N A I j ENCLOSURE \ / DRAIN LEADER COVER k h USE COSMETIC CAULKING CLAMPS {� T� AROUND EDGE FOR e� INBE a1T FINISHING TR1It,! PLASTIC DRAIN LEADER, ' �1T A^ ATTACHMENT J ,ti 6q� PERIMFTER GUTTER RS T 0 DETAIL C1 REV. 09/15/92 2'-7 7/8" (DECK CUT IYP) \ \ I \ \ I \ I \ I � I \ \ I U A \O / \ I I I 0 3 -0 RADIUS CORNER 'REV. 03 -03 -95 _ __-- -� �kE N INSTALLATION NOTES: DETAIL C -1 ATE 1) PRIOR TO GUTTER INSTALLATION # I REMOVE MATERIAL AS SHOWN. W14 BEAM DETAIL C3 �N CUT OUT & OVERFLOWOF REV. 10/27/92 SEE NOTE 2 MORE THAN (2) ARE PRESENT 2) USING #1Ox3/4" TEK SCREWS, CENTER GUTTER ATTACH PLASTIC EMERGENCY OVERFLOW INTO POSITION AS SHOWN. DECKING 3) CAULK AROUND OVERFLOW AS REQUIRED. CAULKING SHALL SEE NOTE # 3 MATCH DECKING. SEE NOTE 2 PLASTIC OVER 4) IF REQUIRED PAINT OVERFLOW TO MATCH DECKING. / \ PURUN BEAM DETAIL i REV. 09/08/94 \ 3 5/8'x20 GA. CONT. DRYWALL STUD USE McGEE BEAM CUP TO \ ATTACH TO PURUN BEAM & BEAM CUP E 3" DECK PAi.c USE #12x1 TEK O 24 O.C. TO ATTACH TO DECK PANEL MAIN FRAME I I AND GREATER 1 /4'x6'x10' PLATE — (3' GA. HOLES) WELDED TO W6x9 BEAM W6x9 STRUT FLANGE 3 18 (4) 5/8'0 BOLTS x 2' LONG A -325 BOLTS W/ (4) 5/8' HEX 3/ NUTS do (8) 5/8' I.D. WASHERS. DETAIL GS3 REV. 3 07/27/94 ST�FNf3i NOTE: USE 3 5/8' STUD AT STARTING PANEL ONLY. SEE DETAIL CP3 FOR INSTALLATION PROCEDURES 2 1 /2' STUD AT N N t 1 1/2' 1 1/2' r 4 1/2 _ 4 112" T.rP >_. TOP ANGLE FLT.--ma C V10ER BACK 8EF�2E (TRIM 109) ATTACHING THE BRACE BACK HALF of 2 PC. DIVIDER m TO TOP —= OF BRACE 110x3/4 TEK (BOTH SIDES) 2 PC. MATED BRACE (3) #10x3/4 TEK /10x3/4 TEK. (BOTH SLOES) _ /12x1 TEK — I� (2) 12 -24x1 1/4 TEK O SHC*- iINSTALLED 6' HAT 1 Cr �' FASCIA FLAS�.EG w/ SLPRUF ATTACH BET*EE "d HANGER w/ #10Y3/4 TEK AS NEEDED CUT FASCIA FLAWING TO FIT IN BET'JrEEN Di`r'LtRS ATTACVED w/ #'- _lx3 /4 /12x1 TEK A'TACttES - PURLIN _ - -6 -- 24' HAT PERIMETER GUTTER HANGER SPACED O 48' (UNLESS OTHERWISE NOTED) - - -- -- FOR 'WINDS OF 100 MPH OR OVER. PERIMETER GUTTER HANGEI TO BE SPACED AT 32'. 4--1/2- SEF GEN. NOTES FOP WIND LOAD, -_ - -� ----- -.. �._. .-..�..-- _..-.......��..-.....- (12x1 TEK ATTACHES GUTTER HANGER TO DECK GE 1000 CAULK JOINT AT CECKING & PERMEitR GUTTER _�— -- PERIMETER GUTTER OGNNECTIC�I PL 3/8' (N.S. & F.S.) CAULK JOINT AT PERIMETER GUTTER N, __ — 4 1 (STEEL OVER 16 HIGH) SURE W/ GE 1000 CAULK GE 1000 — - PL 1/4" (N.S. & F.S.) #6x3/4 S/S BUGLE HEAD - DETAIL FD1_ APPf2OX 2' ON CENTER PAlN7 TO COLOR OF FASCIA REV.4 6/30/94 SIDE � I TYP /'4 D 3' COL. DETAIL REV, 11/18/94 . -- 3/8' PL STiFFENE� N.S. & F.S. TYPIC kL (ANY BE" CliER 16- HICK) 1/4- PL STIFFENER N.F. * F.S. TTF C &d .,--- �- N PURUN 1 (4) 55/8"0 HEX- NUTS &3(8) 5/8 BOLTS I.D, WASHE 4 S BEAM CLIP 3' DECK PANEL J (4) 3/4.0 HOLES — (1)PL1 /2'x6'x0' -6'LG. 41 40 _/ TO 6 r PLA PLATE N \ 1 1/2 36. — 1 1/2' DETAIL A__51 REV. 02/09/95 USED THIRD DECK RIB. 1I GA. STEEL I TOP & 607T4M Y1EY�i NOTE: CANOPY BE/W/ CiJPS MUST BE / 3" DECK PANEL \ INSTALLED ON BOTH #S OF THE / 3/8 d SET SCREW PURUN. ATTAChW THE 1st FOUR(4) DECK PANELS ON BOTH ENDS OF THE / LOCK NUT CANOPY. ALL OTHER LOCAICHS > \ ALTERNATE SIDES OF PI;RL:N. N ID Dsuct c r#J Lit TERNATING START END OF _PANELS 04 1 1/32' CLAMPING SURFACE DETAIL -- CP2_ REV.4 11/11/93 -- -� DECKING BELOW 2 3/8_ —_ PURUN SIDE V w McGEE BEAM CLIP DET_AII MATE- -R1Al: 11 GAUGE PLATE, ASTM A526 CQ (GALVAN' 7 =ID ); HARDENED C1018 -1022 LOW CARBON STEEL WIRE SET SCR; .v (Z ': = PLATED) _ v 1 A'tiA CLIP IN TA ATl N PRQis�R�: SET BEAM v1 CLIP 'WITH SET Sr TOP Cf EcA;41 T \i tiit A T7 rT1 +\ lcr,. �L� ST �` Fal.4 FLAN ',5':H I r (L 1 , FLAP GE AND CLAMPING SJRFACE Uf ,C` R DF CK RIB. PUSH :UP AG ? „;J . U 11 _I i r� i I _ S POSSIBLE. W' -,iLE KEEP N` �,t - JF viR 9-CAL, TU?`J Sc i cFT SCREW AS FAF ONTO BEAM SET G INTO STEEL B' =A�d FLANGE, -_`, _� -_I� TO TUK -,_PEW TO SNUG TGHT WITHOUT a � 'RE'N 3/4 TURN (27C'). TIGHT-L', : `L UT MAKING SURE THAT BcA„I Cl PURUN BEAM / \ / BEAM CUP (TYP) � = l 2 1/2* x16 GA CANT. DRYWALL — STUD USE McGEE BEAM CUP TO - ATTACH TO PURUN BEAM O OPPOSITE SIDE of BEAM DECK CUP & USE #12x1 TEK O 214' O.C. TO ATTACH TO DECK PANEL / (TYP 3�DECK RIB) NOTE CANOPY BZAM CLIPS MUST BE INSTALLED ON BOTH SIDES OF THE / 3' DECK PANEL \ PURUN, ATTACHING THE Is', FOUR(4) DECK PANELS ON BOTH ENDS OF THE CANOFlY. ALL OTHER LOCATIONS r \ ALTERNATE SLOES OF PURLIN.y� / FINISH END OF PANE I:S -,' -„ D L /10 T_ iI r 11 /11 /93 �W SEE NOTE # 2 PERIMETER GUTTER = SEE NOTE # 2 FOR WINDS OF 100 MPH OR OVER. DIWCERS To BE SPACED AT 29 1/4' (SEE GEN. NOTES FOR WAND LOAD) MATED BRACE SPACED O 39' (UNLESS OTHERWISE NOTED) 160/4 S/S BUGLE HEAD APPDX. 2' ON CENTER -- 112x1 TEK (1) AT EACH DIVIDER fl 60TH /SIDE FRONT HALF of 2 PC. DIVIDER SPACED O 39' O.C. A.C.M. FASCIA #1 C-0 /4 TEK (BOTH SIDES) 11,3x3/4" ILA AT IA.tHES LACK of DIVIDER TO ENCL OQJRE or GUTTER #10x3/4' TEK ATT,ICHES ENCLOSURE TO PERIMETER GUTTER (SPACED O ll 12' APART) - I- .i #100/4 TEK (BOTH SIDES) 38' HAT MOUNTED w/ #12x1 TEK TO DECK PANELS SPACED O 39-(UNLESS OTHERWISE NOTE'S) DECKING J SEE DETAIL CP3 _ BECAUSE DECKING IS PARALLEL WITH 2 PC DiV1Dt -R &FASCIA A 38' HAT IS USED AS A MOUNTING DEVICE FOR THE MATED BRACE ALL OTHERS PARTS OF THE FASCIA REMAIN THE SAM_ AS THE SIDE SECTION. THEREFORE. SEE SIDE SECTION FOR IWORMA110N NOT SH,OwN W14 BEAM N AND GREATER 1/4'x6'x10' PU>TE (3' GA. HOLES) WELDED - TO W6x9 BEAM W6x9 STRUT FLANGE TO PLAT£ (TYP) 3 6 00 (4) 5/8'0 BOLLS x 2' LONG 3 16 A -325 BOLTS W/ (4) 518' HEX NUTS do (8) 5/8' I.Q. WASHERS. DETAIL GS5_N REV.3 07/27/94 snFFtmt INSTALLATION NOTES: 1) PRIOR TO GUTTER INSTALLATION RII� REMOVE MATERIAL AS SHOWN. 2) USING jjOx3 /4' TEK SCREWS, GUTTER HANGER ATTACH PLASTIC EMERGENCY OVERFLOW INTO POSITION AS -- SHOWN. 3) CAULK AROUND OVERFLOW AS REQUIRED. CAULKING SHALL MATCH DECKING DECKING. SEE NOTE # 3 4) IF REQUIRED PAINT OVERFLOW TO MATCH DECKING. PLASTIC OVERFLOW DETAIL C REV. 10/27/92 DETAIL FD_2 REV.3 6/30/94 END 3/8' PL STIFFENER �.1t© 0 0 N.S. & F.S. TYPICAL (ANY BEAM OVER 16' HIGH) 1/4- PL STIFFL.'NER N.S. & F.S. TYPICAL W MAIN FRAME TE (TYP) W PURUN CL (4) 5/8'0 x 2 -1/2' LG. A -325 BOLTS W/ (4) 5/8' HEX. NUTS & (E) 5/8' BEAM CUP I.D. WASHERS 3' DECK PANEL . (4) 3/4'0 HOLES l —PH2O (0) PL I PURUN DETAIL AH�_ REV.5 08%24/94 PR. J08 NO. FWAL JC8 NOT 'A IG y0. - I3925 � \ ;. ISr '. • f . COFFORATiON MARATHON OIL COMPANY - � Sf 12701 East Independence 10005 N. MICHIGAN ( U. S. HIGH-WAY 421) -.;c �, SI r Btvd. P.O. Box 1375 C,ARMEL, IN f `�` Matthews. NC 28106 -1375 -- n� n Phone: 704 882 -1500 SCAT F I ( 1/8 =1' 0 IN ACCORDANCE ? y + 900 526 -5589 - � z 1 t ( DATE 2 19 9c PATH REV. _, nts are the T T , D C AN C� P Y r y of McGee Corp . 1 — S �T � '' _ i__i ,_,ction or reuse 13_ ° -�-= �I i w.thvut wntt.n t , , r -I LPL L_ 4 112' 3/4” x 12" x 1' -6' LG. - CL (4) 314 "0 HOLES. ALONG W/ x 3' LG. A -325 BI TS W/ �4�5/8's 4 5/8' HEX. NUTS & (8) I.D. W:3jc—RS PL 3/4" 3" N3cr I (T (p) 5�^ 12 "0 PIPE DE- j' AIL _a. C) F.E Y.3 0/19/94 4 112" T.rP >_. TOP ANGLE FLT.--ma C V10ER BACK 8EF�2E (TRIM 109) ATTACHING THE BRACE BACK HALF of 2 PC. DIVIDER m TO TOP —= OF BRACE 110x3/4 TEK (BOTH SIDES) 2 PC. MATED BRACE (3) #10x3/4 TEK /10x3/4 TEK. (BOTH SLOES) _ /12x1 TEK — I� (2) 12 -24x1 1/4 TEK O SHC*- iINSTALLED 6' HAT 1 Cr �' FASCIA FLAS�.EG w/ SLPRUF ATTACH BET*EE "d HANGER w/ #10Y3/4 TEK AS NEEDED CUT FASCIA FLAWING TO FIT IN BET'JrEEN Di`r'LtRS ATTACVED w/ #'- _lx3 /4 /12x1 TEK A'TACttES - PURLIN _ - -6 -- 24' HAT PERIMETER GUTTER HANGER SPACED O 48' (UNLESS OTHERWISE NOTED) - - -- -- FOR 'WINDS OF 100 MPH OR OVER. PERIMETER GUTTER HANGEI TO BE SPACED AT 32'. 4--1/2- SEF GEN. NOTES FOP WIND LOAD, -_ - -� ----- -.. �._. .-..�..-- _..-.......��..-.....- (12x1 TEK ATTACHES GUTTER HANGER TO DECK GE 1000 CAULK JOINT AT CECKING & PERMEitR GUTTER _�— -- PERIMETER GUTTER OGNNECTIC�I PL 3/8' (N.S. & F.S.) CAULK JOINT AT PERIMETER GUTTER N, __ — 4 1 (STEEL OVER 16 HIGH) SURE W/ GE 1000 CAULK GE 1000 — - PL 1/4" (N.S. & F.S.) #6x3/4 S/S BUGLE HEAD - DETAIL FD1_ APPf2OX 2' ON CENTER PAlN7 TO COLOR OF FASCIA REV.4 6/30/94 SIDE � I TYP /'4 D 3' COL. DETAIL REV, 11/18/94 . -- 3/8' PL STiFFENE� N.S. & F.S. TYPIC kL (ANY BE" CliER 16- HICK) 1/4- PL STIFFENER N.F. * F.S. TTF C &d .,--- �- N PURUN 1 (4) 55/8"0 HEX- NUTS &3(8) 5/8 BOLTS I.D, WASHE 4 S BEAM CLIP 3' DECK PANEL J (4) 3/4.0 HOLES — (1)PL1 /2'x6'x0' -6'LG. 41 40 _/ TO 6 r PLA PLATE N \ 1 1/2 36. — 1 1/2' DETAIL A__51 REV. 02/09/95 USED THIRD DECK RIB. 1I GA. STEEL I TOP & 607T4M Y1EY�i NOTE: CANOPY BE/W/ CiJPS MUST BE / 3" DECK PANEL \ INSTALLED ON BOTH #S OF THE / 3/8 d SET SCREW PURUN. ATTAChW THE 1st FOUR(4) DECK PANELS ON BOTH ENDS OF THE / LOCK NUT CANOPY. ALL OTHER LOCAICHS > \ ALTERNATE SIDES OF PI;RL:N. N ID Dsuct c r#J Lit TERNATING START END OF _PANELS 04 1 1/32' CLAMPING SURFACE DETAIL -- CP2_ REV.4 11/11/93 -- -� DECKING BELOW 2 3/8_ —_ PURUN SIDE V w McGEE BEAM CLIP DET_AII MATE- -R1Al: 11 GAUGE PLATE, ASTM A526 CQ (GALVAN' 7 =ID ); HARDENED C1018 -1022 LOW CARBON STEEL WIRE SET SCR; .v (Z ': = PLATED) _ v 1 A'tiA CLIP IN TA ATl N PRQis�R�: SET BEAM v1 CLIP 'WITH SET Sr TOP Cf EcA;41 T \i tiit A T7 rT1 +\ lcr,. �L� ST �` Fal.4 FLAN ',5':H I r (L 1 , FLAP GE AND CLAMPING SJRFACE Uf ,C` R DF CK RIB. PUSH :UP AG ? „;J . U 11 _I i r� i I _ S POSSIBLE. W' -,iLE KEEP N` �,t - JF viR 9-CAL, TU?`J Sc i cFT SCREW AS FAF ONTO BEAM SET G INTO STEEL B' =A�d FLANGE, -_`, _� -_I� TO TUK -,_PEW TO SNUG TGHT WITHOUT a � 'RE'N 3/4 TURN (27C'). TIGHT-L', : `L UT MAKING SURE THAT BcA„I Cl PURUN BEAM / \ / BEAM CUP (TYP) � = l 2 1/2* x16 GA CANT. DRYWALL — STUD USE McGEE BEAM CUP TO - ATTACH TO PURUN BEAM O OPPOSITE SIDE of BEAM DECK CUP & USE #12x1 TEK O 214' O.C. TO ATTACH TO DECK PANEL / (TYP 3�DECK RIB) NOTE CANOPY BZAM CLIPS MUST BE INSTALLED ON BOTH SIDES OF THE / 3' DECK PANEL \ PURUN, ATTACHING THE Is', FOUR(4) DECK PANELS ON BOTH ENDS OF THE CANOFlY. ALL OTHER LOCATIONS r \ ALTERNATE SLOES OF PURLIN.y� / FINISH END OF PANE I:S -,' -„ D L /10 T_ iI r 11 /11 /93 �W SEE NOTE # 2 PERIMETER GUTTER = SEE NOTE # 2 FOR WINDS OF 100 MPH OR OVER. DIWCERS To BE SPACED AT 29 1/4' (SEE GEN. NOTES FOR WAND LOAD) MATED BRACE SPACED O 39' (UNLESS OTHERWISE NOTED) 160/4 S/S BUGLE HEAD APPDX. 2' ON CENTER -- 112x1 TEK (1) AT EACH DIVIDER fl 60TH /SIDE FRONT HALF of 2 PC. DIVIDER SPACED O 39' O.C. A.C.M. FASCIA #1 C-0 /4 TEK (BOTH SIDES) 11,3x3/4" ILA AT IA.tHES LACK of DIVIDER TO ENCL OQJRE or GUTTER #10x3/4' TEK ATT,ICHES ENCLOSURE TO PERIMETER GUTTER (SPACED O ll 12' APART) - I- .i #100/4 TEK (BOTH SIDES) 38' HAT MOUNTED w/ #12x1 TEK TO DECK PANELS SPACED O 39-(UNLESS OTHERWISE NOTE'S) DECKING J SEE DETAIL CP3 _ BECAUSE DECKING IS PARALLEL WITH 2 PC DiV1Dt -R &FASCIA A 38' HAT IS USED AS A MOUNTING DEVICE FOR THE MATED BRACE ALL OTHERS PARTS OF THE FASCIA REMAIN THE SAM_ AS THE SIDE SECTION. THEREFORE. SEE SIDE SECTION FOR IWORMA110N NOT SH,OwN W14 BEAM N AND GREATER 1/4'x6'x10' PU>TE (3' GA. HOLES) WELDED - TO W6x9 BEAM W6x9 STRUT FLANGE TO PLAT£ (TYP) 3 6 00 (4) 5/8'0 BOLLS x 2' LONG 3 16 A -325 BOLTS W/ (4) 518' HEX NUTS do (8) 5/8' I.Q. WASHERS. DETAIL GS5_N REV.3 07/27/94 snFFtmt INSTALLATION NOTES: 1) PRIOR TO GUTTER INSTALLATION RII� REMOVE MATERIAL AS SHOWN. 2) USING jjOx3 /4' TEK SCREWS, GUTTER HANGER ATTACH PLASTIC EMERGENCY OVERFLOW INTO POSITION AS -- SHOWN. 3) CAULK AROUND OVERFLOW AS REQUIRED. CAULKING SHALL MATCH DECKING DECKING. SEE NOTE # 3 4) IF REQUIRED PAINT OVERFLOW TO MATCH DECKING. PLASTIC OVERFLOW DETAIL C REV. 10/27/92 DETAIL FD_2 REV.3 6/30/94 END 3/8' PL STIFFENER �.1t© 0 0 N.S. & F.S. TYPICAL (ANY BEAM OVER 16' HIGH) 1/4- PL STIFFL.'NER N.S. & F.S. TYPICAL W MAIN FRAME TE (TYP) W PURUN CL (4) 5/8'0 x 2 -1/2' LG. A -325 BOLTS W/ (4) 5/8' HEX. NUTS & (E) 5/8' BEAM CUP I.D. WASHERS 3' DECK PANEL . (4) 3/4'0 HOLES l —PH2O (0) PL I PURUN DETAIL AH�_ REV.5 08%24/94 PR. J08 NO. FWAL JC8 NOT 'A IG y0. - I3925 � \ ;. ISr '. • f . COFFORATiON MARATHON OIL COMPANY - � Sf 12701 East Independence 10005 N. MICHIGAN ( U. S. HIGH-WAY 421) -.;c �, SI r Btvd. P.O. Box 1375 C,ARMEL, IN f `�` Matthews. NC 28106 -1375 -- n� n Phone: 704 882 -1500 SCAT F I ( 1/8 =1' 0 IN ACCORDANCE ? y + 900 526 -5589 - � z 1 t ( DATE 2 19 9c PATH REV. _, nts are the T T , D C AN C� P Y r y of McGee Corp . 1 — S �T � '' _ i__i ,_,ction or reuse 13_ ° -�-= �I i w.thvut wntt.n t , , r -I