HomeMy WebLinkAboutEP200Ar7
rn
0
ri
0
g
N
�i
U)
S
N
Q
0
N _
w�
N N
82
8>
CM
0
Ud
U�
O N
sg
�o
E.
Z
�o
U_ rL
6 8.1 B.2 85 5 A A 1 C D
1
m
N
v -
TI-
N L
A
ON1
tJ
O -
A -
A -
—
GENERAL NOTES:
N
V
I T
A I
I I I I
U
A
N
-
41
B.
O -
A -
A -
—
D.5 E E.5 E.9 F F.9 G
I I I I I I I
I I I I I 1 1
ER
n r� rnnr�
I I I I I I I I I I I
__�__ Garage Level power plan
EP200A
4 y6 " =1' -0" N
d
Z
CD
Ir
W
Z
Z
W
a
Z
H
J
N
0
V
W
IM
M
0
TZ
i
O
7
ormorri
m
CARM E L
C I'rY CENTER
PEDCOR DESIGN GROUP
o Architecture / Project Managment:
• 335 Ridgepoint Drive
Carmel, Indiana 46032
317.705.7979 (phone)
317.705.7980 (fax)
ttJ ��•; ��� \STEREO.,•
C)
No. 13968
w=
O • STATE 4,j
C�
t
U
N
M
Note:
Refer to Life Safety plans for fire rated structure(s). Provide proper fire
stopping at these locations, refer to specifications. All penetrations
thru ceiling structure to exterior plaza level shall have a 3 hour fire
rating.
Note:
Contractor shall coordinate with all trades with conduit/power feeder
routing and sanitary/water /storm piping and fire protection lines to
avoid any conflicts of installation. Overhead conduit and power to be
installed high to structure as possible. All work must be above 10' -6"
above finished garage floor including all clevises and brackets to
piping, conduit, fittings and fixtures. Refer to details #2, #3, and #4 on
sheet EP700 for typical conduit routing.
Note:
Contractor shall refer to "T" series sheets for additional conduit,
junction box, rough -in installation and grounding for low voltage
systems including phone, IT, security and sound system as required.
Contractor shall have all costs, material and labor included in the bid
proposal associated with the Technology Plans.
KEY PLAN
SCALE:NTS
PLAN NORTH
Developer:
P E D C 0_ R
?�p ammo
DEVELOPMENT CO.
W
F�
Z
W
U
H
U
J
W
Q
U
Project:
CD
Z
Y
GENERAL NOTES:
,V
I T
A I
I I I I
D.5 E E.5 E.9 F F.9 G
I I I I I I I
I I I I I 1 1
ER
n r� rnnr�
I I I I I I I I I I I
__�__ Garage Level power plan
EP200A
4 y6 " =1' -0" N
d
Z
CD
Ir
W
Z
Z
W
a
Z
H
J
N
0
V
W
IM
M
0
TZ
i
O
7
ormorri
m
CARM E L
C I'rY CENTER
PEDCOR DESIGN GROUP
o Architecture / Project Managment:
• 335 Ridgepoint Drive
Carmel, Indiana 46032
317.705.7979 (phone)
317.705.7980 (fax)
ttJ ��•; ��� \STEREO.,•
C)
No. 13968
w=
O • STATE 4,j
C�
t
U
N
M
Note:
Refer to Life Safety plans for fire rated structure(s). Provide proper fire
stopping at these locations, refer to specifications. All penetrations
thru ceiling structure to exterior plaza level shall have a 3 hour fire
rating.
Note:
Contractor shall coordinate with all trades with conduit/power feeder
routing and sanitary/water /storm piping and fire protection lines to
avoid any conflicts of installation. Overhead conduit and power to be
installed high to structure as possible. All work must be above 10' -6"
above finished garage floor including all clevises and brackets to
piping, conduit, fittings and fixtures. Refer to details #2, #3, and #4 on
sheet EP700 for typical conduit routing.
Note:
Contractor shall refer to "T" series sheets for additional conduit,
junction box, rough -in installation and grounding for low voltage
systems including phone, IT, security and sound system as required.
Contractor shall have all costs, material and labor included in the bid
proposal associated with the Technology Plans.
KEY PLAN
SCALE:NTS
PLAN NORTH
Developer:
P E D C 0_ R
?�p ammo
DEVELOPMENT CO.
W
F�
Z
W
U
H
U
J
W
Q
U
Project:
CD
Z
Y
VJ
Q
GENERAL NOTES:
C
A.
All 120 volt, 20 amp circuits over 100' in length shall be #10 AWG,
U
ICU
ICU
P-103
B.
W
ICU
over 275' in length shall be #8 AWG, and over 400' in length shall be
U
VJ
Q
PLAN NOTES: Project Number:
OContractor shall provide and install a disconnect switch with time
delay fusing for elevator equipment. Provide with shunt -trip for recall. 0502.01
Connect recall to FA system as required. Provide a mechanical aux.
contact for battery lowering. Coordinate exact location with elevator
installer prior to rough -in. Refer to schedule for over - current size. Sheet Title:
OCommunications conduit to wrap garage ceiling and structure. Refer Garage Level
to "T" series sheets for detailed information. Power
OCommunications junction box near ceiling structure. Refer to "T" Garage Plan
series sheets for detailed information.
Sheet Number:
OCircuit(s) will originate from a Future "House Panel ".
OContractor shall provide and install heat tracing for storm, waste and
water lines as shown. Heat trace shall be like Thermon #8- FLX -2,
with line sensing thermostat #N4X -40. Provide fusible switch where
more than one run is on a circuit.
O , J • P900
/
10 Provide communications junction box. a 3/4" conduit with pullwire for fan control to nearest �
SContractor shall install conduit tight to ceiling and structure in retail
areas to maximise available ceiling heights for future tenants.
GENERAL NOTES:
A.
All 120 volt, 20 amp circuits over 100' in length shall be #10 AWG,
over 160' in length shall be #8 AWG, and over 275' in length shall be
D SET
g
#6 AWG.
P-103
B.
All 277 volt, 20 amp circuits over 200' in length shall be #10 AWG,
over 275' in length shall be #8 AWG, and over 400' in length shall be
#6 AWG.
Issue Date Drawn By Checked By
C.
Contractor shall coordinate with all other trades to avoid conflicts of
11/21/07 GMH 5LI1
space.
Revisions:
D.
Contractor shall coordinate the exact location of all devices with all
P.103.ADD.001 03 -14 -08
other trades prior to rough -in. Exact location to be determined in the
field.
P.104.PR.001 05 -16 -08
E.
Refer to sheet EP700 for symbols and details.
Construction Set 06 -20 -08
F.
Refer to sheet EP700 for light fixture schedule.
G.
Refer to sheet EP601 for panel schedules.
H.
Contractor shall coordinate with the mechanical and plumbing
contractors for exact locations of equipment prior to rough -in.
PLAN NOTES: Project Number:
OContractor shall provide and install a disconnect switch with time
delay fusing for elevator equipment. Provide with shunt -trip for recall. 0502.01
Connect recall to FA system as required. Provide a mechanical aux.
contact for battery lowering. Coordinate exact location with elevator
installer prior to rough -in. Refer to schedule for over - current size. Sheet Title:
OCommunications conduit to wrap garage ceiling and structure. Refer Garage Level
to "T" series sheets for detailed information. Power
OCommunications junction box near ceiling structure. Refer to "T" Garage Plan
series sheets for detailed information.
Sheet Number:
OCircuit(s) will originate from a Future "House Panel ".
OContractor shall provide and install heat tracing for storm, waste and
water lines as shown. Heat trace shall be like Thermon #8- FLX -2,
with line sensing thermostat #N4X -40. Provide fusible switch where
more than one run is on a circuit.
O , J • P900
/
10 Provide communications junction box. a 3/4" conduit with pullwire for fan control to nearest �
SContractor shall install conduit tight to ceiling and structure in retail
areas to maximise available ceiling heights for future tenants.