Loading...
HomeMy WebLinkAboutEP5012 m a v M N r, O a Zi I I I I I I I� EM3A -5 Q.2 CC EM3A -8 TCP 8 I TAM 'F3' F ' .C2, EM3A -11 I PoAS FD 'X1 8 12 F F3' I R R.1 R.2 R.3 R.5 R.6 I I Eva y - P- 1 l PA14 - 8 X3 ' bL ' I I II I ! ReW 'F3' 'F3' I I - 3.3 KW ! GH1 -12 �,'F1' TV I Loading I PA15 i 'F3' Elev ' 8 5 ens" EM3A -13 Fi'- AL �5 8 - - 4 lk,411 F 'F1' j 8 3 EA10M F3' Main EM3 -1 Switch /Distribution r 1IMS ,q L_�4 'FT F3' Powr 1st Rm 'F1 ' F I"T3" Panel "EM3" Mach 8 Fan m Panel "EM3A" Fen TA6 OO r F3' EM3A -17 MA -4 F EM3A 18 EF- ' 11 11 M 'FT �p - - _ EM3A -11 EM3A -14 12 I I 8 5 I I RIM RAW I I F3' I I 'F I I 'F3' r� IIl�!!I*�� iu J 20 19.9 19 18.1 I 18 i I 'F3' d u it 'X3' a � I I� i I II 8 i Y_ - 1 i III ' I 73' aA7 18 f umw o_ U N X3' EA11 n RAMP UP 1:12 I I I I 8 3/4 "C. for loop 3/4 "C. detection 120V., EM3A -1 On Gate Proximity CarJ Reader G EN - 20V., 20 . 3/4 "C. 1 "C. to nearest I UummulliUdtiWiti I 3/4 "C. for control I 3/4 "C. for junction box I I future AVI unit I I I 18 I - I I �T reinch Drains 3/4 "C. 1 I 120V., 20A.' 3/4 "C. -Re . Clvii Drawings On Gate detection Proximity Carb Reader I 120V., 20A. 3/4 "C. for control 3/4 "C. - }I•- - - - - -- G - - - - -EN I�- -- - -- - I- - - - - - - - - - - - - - - - - - - - - - - - F - - - - - - - - - - - - - - - - - G FVJ � - I Proximity Card Reader I �-_ _ IL On Gate 3/4 "C. for loop I detection 3/4 "C. for control, 3/4 "C. for I 120V., 20A. i- I future AVI unit) I 3/4 "C. roximity aar FFeader I / O� n Gate I I 3/4 C. for 3/4 C. for loop futu a AVI unit detection I 1 1/4 "C. to nearest 17.1 17 16.9 15.5 I L.9 M Q�! - EMA3 -20• M.5 M.9 N N.1 T- 20 I F ! I I I ! I 3 1 EMA3 -19 4 3 4 _2 __ Enlarged garage power plan M.9 U N.1 N.5 ( P EM1A -1 _N10 u nted _ EM3A-9-- Ea EM1A -3 3/4 "C. for loop I I i detection III II 3/4 "C. for future AVI unit o 120V., 20A. 3/4 "C. _ 8 5 120. OA. 3/4 "C. 3/4 "C. for III! future AVI unit I 3/4 "C. for loop \ III detection III Mounted on Gate 1 "C. to nearest communications junction box II 14 13.9 I I ____3____ Enlar ed garage power plan EP501 1/8 " =1' -0" N i I I I a I I GENERAL NOTES: A. All 120 volt, 20 amp circuits over 100' in length shall be #10 AWG, over 160' in length shall be #8 AWG, and over 275' in length shall be #6 AWG. B. All 277 volt, 20 amp circuits over 200' in length shall be #10 AWG, over 275' in length shall be #8 AWG, and over 400' in length shall be #6 AWG. C. Contractor shall coordinate with all other trades to avoid conflicts of space. D. Contractor shall coordinate the exact location of all devices with all other trades prior to rough -in. Exact location to be determined in the field. E. Refer to sheet EP700 for symbols and details. F. Refer to sheet EP700 for light fixture schedule. G. Refer to sheet EP601 for panel schedules. PARKING ENTRY /EXIT GATE LEGEND: Gate EN Entry Terminal EX Exit Terminal ®R Proximity Card Reader �F Full Sign VI Automatic Vehicle ID Reader Mounted Overhead in the Lane Note: Equipment provided and installed by others. WM0 EM3A -16 I EM3A -15 of r I , OR M •-• •. I 11,-_ •- •• - • . Z PLAN NOTES: - w OContractor shall provide and install a disconnect switch with time T delay fusing for elevator equipment. Provide with shunt -trip for recall. W C ARM E L Connect recall to FA system as required. Provide a mechanical aux. W contact for battery lowering. Coordinate exact location with elevator Z CITY CENTER DESIGN GROUP installer prior to rough -in. Refer to schedule for over - current size. (� o Architecture /Project Managment: 22 ) nr Z Cot actor shall provide and install a lockable fused switch for W % • 335 Ridgepoint Drive elevator cab lighting. _ Carmel, Indiana 46032 317.705.7979 (phone) O Contractor shall provide and install a dedicated duplex G.F.I. Z j 317.705.7980 (fax) Receptacle for elevator equipment use. H % y OContractor shall provide a telephone rough -in for dedicated elevator OBER���'�•, cab phone line. Z �•`t� 0 ��� •'A 5 Contractor shall provide and install a weatherproof light switch, light V • _ -o 2. N0. 13968 i fixture and G.F.I. receptacle in elevator pit. Mount light switch at +1' -6" a.f.f. receptacle and pit light at 12" below top of pit. W % � 0 s STATE LUUJ '� y of OCircuit(s) will originate from a Future "House Panel ". J ° ,�'S /ONAt- �aV,`�� 11 Electrical connection to coiling overhead fire door. Verify electrical W connections, voltage and phase with door manufacter prior to O rough -in /connection. Door shall be tied into Fire Alarm System. Z 12 Connect Fire Damper to Fire Alarm Panel as required. = j O17 Rough -in push button and motor operated door as required. 0 Coordinate exact locations and rough with manufacturer prior to rough -in. 18 TV rough -in with outlet at +54" to centerline. Refer to detail C/T702 S for requirements. R R.1 (R.2) R.3 R.5 RA II - i I I I a I F3 I J I i I KEY PLAN SCALE: NTS PLAN NORTH Developer: P E D -C O R DEVELOPMENT CO. Project: CU Z CU r W CU J U BID SET P.103 Issue Date Drawn By Checked By 1 1/21/07 GMH 5LH Revisions: P.109.ADD.001 03 -14 -08 P .104 . P R. 001 05 -16 -08 Construction Set 06 -20 -08 Project Number: 0502.01 Sheet Title: Garage Level Power Plans Enlarged Sheet Number: 110) sP01