Loading...
HomeMy WebLinkAboutT001TELECOMMUNICATION TECHNOLOGY LEGEND (CONTINUED) MISCELLANEOUS ROUGH -IN (SUBSCRIPT OR SYMBOL ADDED FOR CABLE REQUIREMENTS CEILING MOUNTED REMOTE CABINET R� K I T701 BACKBONE CABLES TO ER/TR; SEE BACKBONE DIAGRAM CEILING MOUNTED WIRELESS ACCESS POINT ENCLOSURE WAP cE 1 DATA CABLE UON M / T701 CEILING MOUNTED WIRELESS ANTENNA SYSTEM ENCLOSURE WA CM 1 DATA CABLE UON N / T701 FLOOR BOX FB x X =FLOOR BOX TYPE; ADDITIONAL SYMBOL REQUIRED TO SPECIFY CABLING J / T702 REQUIREMENT R = RAISED FLOOR MOUNTING X POKE THROUGH DEVICE (FIRE -RATED ASSEMBLY) � F X = POKE THROUGH TYPE; ADDITIONAL SYMBOL REQUIRED TO SPECIFY CABLING G / T702 F O REQUIREMENT F = 2" OFFICE FURNITURE WHIP D / T702 �x CONDUIT STUBBED THROUGH FLOOR EXAMPLES X = CONDUIT TRADE SIZE O / T701 0261/4 CONDUIT SHALL BE CONTINUOUS BELOW FLOOR TO ER/TR OR ZONE CONDUIT SYSTEM; LABEL CONDUIT DESTINATION AND CAP FOR FUTURE USE TELEPOWER POLE x X = POLE TYPE (IF REQUIRED); ADDITIONAL SYMBOL REQUIRED TO SPECIFY L / T702 CABLING REQUIREMENT PROTECTED DEVICE xl PV I K / T702 - - -I SYMBOL INSIDE BOX DETERMINES CABLING REQUIREMENTS RESIDENTIAL STRUCTURED MEDIA CENTER ENCLOSURE (2) DATA CABLES AND AN CABLES; SEE OUTLET DETAILS F / T704 WALL /COLUMN MOUNTED REMOTE TELECOM CABINET RE:MO'I'E TELECOM NIA CADENET XXX = LOCATION ID XXX YYY YYY = BACKBONE DESTINATION WALL /COLUMN MOUNTED REMOTE SOUND CABINET REMOTE SOUND N/A CAHINE;'I' xxx YYY XXX = LOCATION ID YYY = BACKBONE DESTINATION WALL /COLUMN MOUNTED REMOTE TELECOM CABINET (CONDITIONED) CONDITIONED REMOTE N/A CAHINET XXX = LOCATION ID xxx YYY YYY = BACKBONE DESTINATION t- -A °.� -1 WALL MOUNTED SWING -OUT CABINET I SWING OUT N/A xsRU� i XXX = LOCATION ID © - p YYY = BACKBONE DESTINATION CONDUIT TURNED DOWN SIZE AS INDICATED N/A STANDARD SWEEP ELBOW SIZE AS INDICATED CONDUIT TURNED UP N/A STANDARD SWEEP ELBOW CONDUIT (HIDDEN) ` N/A \ BEHIND WALL OR UNDER FLOOR JUNCTION /PULL BOX (CEILING MOUNTED) T002 O MUST BE ACCESSIBLE CHART JUNCTION /PULL BOX (WALL MOUNTED) J T002 MUST BE ACCESSIBLE CHART FIRE RATED SLEEVE THROUGH WALL SIZE AS INDICATED T705 STANDARD SWEEP ELBOW LADDER RACK SIZE AS INDICATED D / T706 8' MOUNTING HEIGHT UON CORRIDOR MOUNTED RINGS LENGTH AS INDICATED C / T7os CENTER -HUNG CABLE TRAY >9 C 1 T706 WIDTH AND LENGTH AS INDICATED TRADITIONAL CABLE TRAY WIDTH AND LENGTH AS INDICATED T706 TELECOMMUNICATION WALL LINING (BACKBOARD) N/A 8' TALL, 4' WIDTH; CUT TO FIT SPACE AS SHOWN TELECOMMUNICATION TECHNOLOGY LEGEND VOICE /DATA STRUCTURED CABLING SYMBOL DESCRIPTION ROUGH —IN DIAGRAM VOICE OUTLET; WALL MOUNTED TELEPHONE F / T701 W • 1 VOICE CABLE UON RESIDENTIAL B = BLANK COVER, NO CONNECTORS OR CABLE D / T704 VOICE OUTLET; PAY TELEPHONE STATION PS • 1 VOICE CABLE UON I ! T701 B = BLANK COVER, NO CONNECTORS OR CABLE VOICE OUTLET; ELEVATOR EQUIPMENT ELEV • 1 VOICE CABLE UON G ! T7O1 VOICE OUTLET; FIRE ALARM CONTROL PANEL FACP • 1 VOICE CABLE LION G / T701 VOICE OUTLET; STANDARD TELEPHONE x . X = QUANTITY OF 4 PAIR VOICE CABLES (MIN. 1 VOICE CABLE WITHOUT SUBSCRIPT) E / T701 F = FACSIMILE MACHINE (VOICE CIRCUIT) B = BLANK COVER, NO CONNECTORS OR CABLE EMERGENCY CALL STATION (INDOOR SAFE ZONE) .EC MINIMUM TWO 4 PAIR UTP CABLES TO ER/TR L /T701 EMERGENCY CALL STATION (OUTDOOR/WEATHERPROOF) V Ec l L / T701 MINIMUM TWO 4 PAIR UTP CABLES TO ER/TR DATA OUTLET; STANDARD x Q X = QUANTITY OF 4 PAIR VOICE CABLES (MIN. 1 DATA CABLE WITHOUT SUBSCRIPT) E ! T701 B = BLANK COVER, NO CONNECTORS OR CABLE DATA OUTLET; BUILDING AUTOMATION SYSTEM BAS D (2) DATA CABLES UON G / T701 WALL MOUNTED WIRELESS ACCESS POINT (UPPER) WAP H / T701 1 DATA CABLE UON CEILING MOUNTED WIRELESS ACCESS POINT WAP 1 DATA CABLE UON J / T701 v x VOICE / DATA OUTLET; STANDARD E / T701 X = QUANTITY OF 4 PAIR VOICE /DATA CABLES (MIN. 1 VOICE AND 1 DATA CABLE �VX WITHOUT SUBSCRIPT) RESIDENTIAL VX = QTY VOICE CABLES & DX = QTY DATA CABLES B = BLANK COVER, NO CONNECTORS OR CABLE D / T704 AUDIO VISUAL LOCAL INPUT DATA OUTLET 17 LI (2) DATA CABLES AND AN CABLES; SEE OUTLET DETAILS A ! T702 LOCAL INPUT VOICE /DATA OUTLET 17 LI (1) VOICE AND (1) DATA CABLE AND AN INPUT CABLES; SEE OUTLET DETAILS A ! T702 WALL MOUNTED TELEVISION (RF) OUTLET WITH CONTROL (DATA) oC E / T701 1 CONTROL (DATA) AND 1 COAXIAL (RF) CABLE UON WALL MOUNTED TELEVISION (RF) OUTLET WITH VOICE AND DATA E / T701 RF 17 1 DATA, 1 VOICE AND 1 COAXIAL (RF) CABLE LION RESIDENTIAL D / T704 AUDIO VISUAL SYSTEMS (FLOOR) x Av X = NUMBER OF GANGS FOR BOX SIZING; ADDITIONAL SYMBOL REQUIRED TO H ! T702 SPECIFY CABLING REQUIREMENTS AUDIO VISUAL SYSTEMS (WALL) 1px I / T702 V X = NUMBER OF GANGS FOR BOX SIZING; ADDITIONAL SYMBOL REQUIRED TO SPECIFY CABLING REQUIREMENTS PANEL (FLAT) TELEVISION /MONITOR OUTLET C / T702 PNL 17 (2) DATA CABLES AND AN CABLES; SEE OUTLET DETAILS RESIDENTIAL E / T704 RF RF WALL MOUNTED TELEVISION OUTLET (UPPER) WITH CONTROL (DATA) I vI vLO TV TV 1 DATA CABLE AND 1 COAXIAL (RF) CABLE; UON B / T702 rte/ n_ Lo LO = ADDITION OF CABLES FROM LOCAL INPUT OUTLET Lo CEILING MOUNTED TELEVISION OUTLET WITH CONTROL (DATA) U RF F / T7O2 0 1 DATA CABLE AND 1 COAXIAL (RF) CABLE; UON Tv Tv LO = ADDITION OF CABLES FROM LOCAL INPUT OUTLET CEILING MOUNTED VIDEO PROJECTOR OUTLET WITH CONTROL (DATA) vP vP 1 DATA CABLE UON E / T702 LO = ADDITION OF CABLES FROM LOCAL INPUT OUTLET Where a telecommunications outlet location is adjacent to an electrical outlet, the mounting height will be the same for each. Where multiple Telecommunications are adjacent (such as Telecommunications and Sound Devices, faceplates shall be coordinated to the same type and color and mounted at the same height. CONDUIT RUNS SHALL HAVE NO MORE THAN 180 DEGREES OF BENDS WITHOUT AN ADEQUATE PULL BOX. Id f THIS TYPE FITTING SHALL BE UTILIZED IN PLACE OF A STANDARD "LB" DESIGN WHERE STANDARD SWEEP ELBOWS CANNOT BE UTILIZED -RPFCIAI FITTINGS Scale = NONE DETAIL DRAWING LABELING DETAIL DRAWING LABELING EXAMPLE DRAWING IDENTIFICATION IS INTENDED TO PROVIDE AN ORDERLY FORMAT TO DELIVER PROJECT INFORMATION A MAJORITY OF DRAWINGS CONTAIN INFORMATION THAT IS REQUIRED OR WILL BE BENEFICIAL TO MULTIPLE DISCIPLINES AND /OR CONTRACTORS. LIKEWISE, EACH SPECIFICATION SECTION MAY REQUIRE INFORMATION ON MULTIPLE DRAWINGS TO COMPLETE THE SYSTEM(S). r 1 a4e _ .• crec sruxw° � � �% THIS TYPE FITTING SHALL BE ADDED TO ALL HORIZONTAL CONDUITS OR SLEEVES WHERE THE VERTICAL CABLE DROP IS GREATER THAN 6" COMPOSITE FLOORPLAN LABELING DRAWING PREFIX Scale= NONE GENERAL NOTES: T TECHNOLOGY DRAWING TYPE GENERAL CABLING NOTE_ S: PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS, DIMENSIONAL STABILITY, INSTALLATION, 0 LEGEND /INDEX/COMPOSITE _ 1 FLOORPLANS OF HIS RESPONSIBILITY TO ALERT DESIGNER TO ERRORS OR OMISSIONS. 2 ELEVATIONS CONTRACTOR SHALL UTILIZE THESE DRAWINGS IN CONJUNCTION WITH THE SPECIFICATIONS TO DETERMINE THE 3 SECTIONALS FULL SCOPE, INTENT AND REQUIREMENTS OF THE PROJECT. SPECIFICATIONS AND DRAWINGS ARE INTENDED TO BE COMPLEMENTARY, NOT MUTUALLY EXCLUSIVE. WORK SHOWN ON THE DRAWINGS BUT NOT LISTED IN THE 4 ENLARGED FLOORPLANS SPECIFICATIONS, AND WORK DESCRIBED IN THE SPECIFICATIONS BUT NOT SHOWN ON THE DRAWINGS SHALL BE 5 DETAILS INTERPRETED AS THOUGH WORK WERE FULLY DESCRIBED IN BOTH PLACES. THE HIGHER QUANTITY, HIGHER 6 DIAGRAMS .. QUALITY, MORE LABOR INTENSIVE AND OVERALL MORE STRINGENT AND MORE COSTLY REQUIREMENT SHALL 7 PATHWAY /ROUGH -IN BUILDING ID 3) EACH CONTRACTOR SHALL VERIFY IN THE FIELD ALL EXISTING APPLICABLE CONDITIONS AND DIMENSIONS S SITE /OUTDOOR (OSP) SHOWN ON THE DRAWINGS AND AS PERTINENT TO THE INTENT OF THESE DRAWINGS. ANY DISCREPANCY G PARKING GARAGE DISCOVERED SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER PRIOR TO THE COMMENCEMENT OF A BUILDING A _ B _ BUILDING B FOR ALL COSTS ASSOCIATED WITH, OR CAUSED BY HIS FAILURE TO COMPLY WITH THIS REQUIREMENT. C BUILDING C EACH CONTRACTOR SHALL REVIEW ALL PORTIONS OF HIS WORK, BEFORE STARTING THE WORK, TO VERIFY D BUILDING D _ . E BUILDING E _ MEAN THE ACCESSIBLE CAVITY ABOVE SUSPENDED CEILING AND (CONTINUE AS NECESSARY) FLOOR LEVEL BENEATH THE DECK /FLOOR ABOVE. CONDUITS STUBBED ABOVE 5) EACH CONTRACTOR SHALL BE RESPONSIBLE FOR JOB CLEANLINESS. PROJECT AREAS SHALL BE THOROUGHLY T UTILITY TUNNEL CLEANED AND TRASH DISPOSED OF AT THE END OF EACH WORK DAY. OWNER'S FACILITIES SHALL NOT BE USED 0 PARKING LEVEL AND BASEMENT FOR WASTE DISPOSAL. 1 FIRST AND PLAZA LEVEL 2 -9 SECOND THROUGH NINTH PROVIDE DUST PROTECTION WHEN WORKING IN EXISTING FACILITIES. SEAL OFF ALL WORK AREAS FROM A -Z 10 -36 TOA1 DRAWING PREFIX DRAWING TYPE BUILDING ID FLOOR LEVEI. FLOORPLAN DRAWING LABELING EXAMPLE T1A2B 1/8" FLOORPLAN DRAWING LABELING EXAMPLE A DRAWING IDENTIFICATION Scale= NONE GENERAL NOTES: 1) NOTHING SET FORTH IN THESE DRAWINGS SHALL RELEASE ANY CONTRACTOR FROM HIS RESPONSIBILITY TO GENERAL CABLING NOTE_ S: PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS, DIMENSIONAL STABILITY, INSTALLATION, 1) PLENUM CABLE REQUIRED IN SPACES DESIGNED FOR RETURN AIR ANCHORAGE, AND COORDINATION WITH OTHER TRADES; OR RELEASE HIM FROM HIS RESPONSIBILITY TO IDENTIFY AND RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, OR FREE HIM TRANSMISSION. ALL PROVIDED CABLE THAT WILL NOT BE INSTALLED IN A FULLY ENCLOSED METALLIC CONDUIT, WITHIN THE AIR SPACE, SHALL BE OF HIS RESPONSIBILITY TO ALERT DESIGNER TO ERRORS OR OMISSIONS. RATED FOR INSTALLATION WITHIN A RETURN AIR PLENUM. 2) CONTRACTOR SHALL UTILIZE THESE DRAWINGS IN CONJUNCTION WITH THE SPECIFICATIONS TO DETERMINE THE 2) ALL INSTALLED CABLING SHALL BE CONTINUOUS AND WITHOUT SPLICES, FULL SCOPE, INTENT AND REQUIREMENTS OF THE PROJECT. SPECIFICATIONS AND DRAWINGS ARE INTENDED TO BE COMPLEMENTARY, NOT MUTUALLY EXCLUSIVE. WORK SHOWN ON THE DRAWINGS BUT NOT LISTED IN THE EXCEPT WHERE OTHERWISE SPECIFICALLY NOTED. SPECIFICATIONS, AND WORK DESCRIBED IN THE SPECIFICATIONS BUT NOT SHOWN ON THE DRAWINGS SHALL BE INTERPRETED AS THOUGH WORK WERE FULLY DESCRIBED IN BOTH PLACES. THE HIGHER QUANTITY, HIGHER 3) NOT USED QUALITY, MORE LABOR INTENSIVE AND OVERALL MORE STRINGENT AND MORE COSTLY REQUIREMENT SHALL APPLY UNLESS OTHERWISE CLARIFIED IN WRITING PRIOR TO BID. 3) EACH CONTRACTOR SHALL VERIFY IN THE FIELD ALL EXISTING APPLICABLE CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWINGS AND AS PERTINENT TO THE INTENT OF THESE DRAWINGS. ANY DISCREPANCY DISCOVERED SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER PRIOR TO THE COMMENCEMENT OF ANY WORK AFFECTED BY, OR RELATED TO, SUCH DISCREPANCY. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH, OR CAUSED BY HIS FAILURE TO COMPLY WITH THIS REQUIREMENT. 4) EACH CONTRACTOR SHALL REVIEW ALL PORTIONS OF HIS WORK, BEFORE STARTING THE WORK, TO VERIFY SPECIAL DEFINITIONS: THAT THE WORK WILL NOT PROHIBIT COMPLETION OF THE PROJECT AS INTENDED IN THESE CONSTRUCTION 1) "ABOVE ACCESSIBLE CEILING" SHALL BE INTERPRETED TO GENERALLY DOCUMENTS. ALL QUESTIONS SHALL BE REFERRED TO THE DESIGNER FOR RESOLUTION. MEAN THE ACCESSIBLE CAVITY ABOVE SUSPENDED CEILING AND BENEATH THE DECK /FLOOR ABOVE. CONDUITS STUBBED ABOVE 5) EACH CONTRACTOR SHALL BE RESPONSIBLE FOR JOB CLEANLINESS. PROJECT AREAS SHALL BE THOROUGHLY ACCESSIBLE CEILING SHALL TERMINATE IN A LOCATION IN WHICH A CLEANED AND TRASH DISPOSED OF AT THE END OF EACH WORK DAY. OWNER'S FACILITIES SHALL NOT BE USED NORMAL HEIGHT PERSON CAN VIEWAND ACCESS WITHOUT STRAIN FOR WASTE DISPOSAL. WHILE STANDING UPRIGHT ON A LADDER OR OTHER VERTICAL LIFT DEVICE, 6) PROVIDE DUST PROTECTION WHEN WORKING IN EXISTING FACILITIES. SEAL OFF ALL WORK AREAS FROM REMAINDER OF THE EXISTING FACILITY TO RETAIN ALL CONSTRUCTION DIRT AND DUST. SEAL EXISTING DOORS WITH TAPE AND PROVIDE DUST -PROOF BARRIERS AS REQUIRED. EXISTING CONDITIONS AND PHASING NOTES: 7) ALL WORK SHALL BE SEQUENCED TO PROVIDE FOR THE OWNER'S CONTINUED USE OF THE EXISTING FACILITY 1) FOR COORDINATION PURPOSES, OCCASSIONALLY AN ITEM OF WORK WILL BE WHEN REQUIRED. OWNER'S ACCESS, EGRESS AND SAFETY SHALL BE MAINTAINED BY EACH CONTRACTOR. THE SHOWN ON THE E SERIES DRAWINGS AND THE T SERIES DRAWINGS. IN SEQUENCE OF WORK SHALL BE AS DETERMINED BY THE CONSTRUCTION MANAGER. REFER TO THE PROJECT ADDITION, THE SAME WORK MAY BE INCLUDED ON MULTIPLE T SERIES DETAIL MANUAL FOR FURTHER REQUIREMENTS. SHEETS FOR SIMILAR REASONS. PLAN NOTE 1 BELOW WILL BE UTILIZED FOR MAJOR WORK ITEMS THAT ARE DUPLICATED. REQUEST A CLARIFICATION FOR 8) EACH CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF ALL SURFACES AND FINISHES IN THE ANY ITEMS THAT APPEAR UNCLEAR AS TO QUANTITY OR CONTRACT INTERIOR OR EXTERIOR OF THE FACILITY. DAMAGED SURFACES OR FINISHES RESULTING FROM THE RESPONSIBILITY. EXAMPLE: ELECRICAL DEVICES ARE SHOWN ON T SERIES PERFORMANCE OF THE WORK OR NEGLIGENCE SHALL BE REPAIRED AT NO COST TO THE OWNER BY THE DETAIL SHEETS FOR COORDINATION AND SPACING PURPOSES; THE RESPONSIBLE CONTRACTOR. FINISHES AND SURFACES SHALL BE MADE TO MATCH THE EXISTING FINISHES OR ELECTRICAL OUTLETS AND POWER EQUIPMENT IS THE RESPONSIBILITY OF SURFACES TO THE SATISFACTION OF THE OWNER AND ARCHITECT /CONSTRUCTION MANAGER. DIVISION 26. LIKEWISE, SOME TELECOMMUNICATIONS CONDUITS APPEAR ONE SERIES SHEETS FOR SPACE COORDINATION; TELECOMMUNICATIONS 9) "TECHNOLOGY" CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING TELEPHONE, DATA, CENTRAL SOUND, PATHWAY AND SPACES ARE COVERED UNDER DIVISION 27. SECURITY CCTV AND ALARM SYSTEM SERVICES IN ALL EXISTING AREAS FOR DURATION OF PROJECT FOR MULTI - PHASED PROJECTS. CONTRACTOR SHALL COLLABORATE WITH OWNER'S TECHNOLOGY PERSONNEL AS 2) RESERVED. NECESSARY AND PROVIDE TEMPORARY WIRING, CROSS - CONNECTS, TERMINATION DEVICES, AND LABOR TO MAINTAIN OPERATION ACCEPTABLE TO THE OWNER. CONTRACTOR SHALL REFER TO THE FRONT END 3) RESERVED. DOCUMENTS OF THE SPECIFICATIONS FOR ADDITIONAL INFORMATION RELATED TO PHASING. ALL PHASING QUESTIONS SHALL BE ADDRESSED PRIOR TO THE CONTRACTOR'S BID SUBMISSION. 4) RESERVED. 10) EACH CONTRACTOR SHALL FIELD VERIFY ALL EXISTING APPLICABLE CONDITIONS AND DIMENSIONS SHOWN ON 5) RESERVED. THE DRAWINGS. AS PERTAINS TO THE INTENT OF THESE DRAWINGS, CONTRACTOR SHALL BRING TO THE ATTENTION OF THE ARCHITECT AND DESIGNER ANY DISCREPANCIES DISCOVERED PRIOR TO THE 6) RESERVED. COMMENCEMENT OF ANY WORK AFFECTED BY OR RELATED TO SUCH DISCREPANCY. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH OR CAUSED BY THAT CONTRACTOR'S FAILURE TO COMPLY WITH THIS REQUIREMENT. 11) CONTRACTOR SHALL USE THESE DRAWINGS IN CONJUNCTION WITH THE SPECIFICATIONS TO DETERMINE THE OP LA N NOTES: FULL SCOPE, INTENT AND REQUIREMENTS OF THE PROJECT. SPECIFICATIONS AND DRAWINGS ARE INTENDED BUT NOT LISTED IN THE TO BE COMPLEMENTARY, NOT MUTUALLY EXCLUSIVE. WORK SHOWN ON THE DRAWINGS 1. ITEMS MAY BE DUPLICATED ON T AND E SERIES SHEETS FOR COORDINATION; SPECIFICATIONS, AND WORK DESCRIBED IN THE SPECIFICATIONS BUT NOT SHOWN ON THE DRAWINGS SHALL BE DO NOT DUPLICATE WORK. SEE EXISTING CONDITIONS AND PHASING NOTE 1 INTERPRETED AS THOUGH WORK WERE FULLY DESCRIBED IN BOTH PLACES. THE HIGHER QUANTITY, HIGHER ABOVE. QUALITY, MORE LABOR INTENSIVE AND OVERALL MORE STRINGENT AND MORE COSTLY REQUIREMENT SHALL 2. NOT USED APPLY. 3• 12) THE COLORS OF CABLING USED FOR ALL COMMUNICATIONS TECHNOLOGY WORK SHALL BE REVIEWED AND APPROVED PRIOR TO PROCUREMENT AND INSTALLATION. 13) LADDER RACK AND OTHER COMMUNICATION TECHNOLOGY CABLING PATHWAYS DEPICTED ON THE ENLARGED FLOOR PLANS SHALL BE PROVIDED AS INDICATED. ADDITIONAL PRODUCTS NECESSARY FOR PROFESSIONAL WIRE MANAGEMENT WITHIN THE MAIN EQUIPMENT ROOM <ER> AND ALL TELECOMMUNICATION ROOMS <TR> SHALL BE ALSO BE PROVIDED AS NECESSARY. 14) THE CONTRACTOR SHALL THOROUGHLY REVIEW THE SPECIFIED ROUGH -IN TO ENSURE THAT IT WILL SUPPORT THE CABLING AND DEVICES TO BE SUPPLIED. REVIEW AND COORDINATION SHALL OCCUR PRIOR TO THE INSTALLATION OF ROUGH -IN. 15) RESERVED. I V AREL PEDCOP DESIGN GROUP t' ; TECH D Y N i��t I ,� f! � I , L J� `i 1!' u LU 7i L_� C U6 r<as' 5'' ,, sfiva <? SUITE 2111150 !ND!AN.AP0L.1G !N461118 317.1:24.6338 317,124 6339 FAX P E D C O R DEVELOPMENT CO. r., M' y7 L; J3 v x: i y L j J., AF k4r"-) s k., CS.. lu S, E. � r 0 i 6 12e F, Gy, ...:!it�: LEGEND '1'001 Y CS.. lu S, E. � r 0 i 6 12e F, Gy, ...:!it�: LEGEND '1'001