Loading...
HomeMy WebLinkAboutT002SYMBOL DERMTKDN 1 ACC Administrative Control Console 21 CAN Campus Area Network 41 DVR Digital Video Recorder 61 IPX Internet Packet Exchange 81 MODEM Modulator Demodulator 101 RFI Request For Information/ Radio Frequency 121 RFI Request For Information/ Radio Frequency 141 TAHC To Above accessible Hallway Ceiling 1 ADA Americans with Disabilities Act 22 CATV Community Antenna Television 42 EC Electrical Contractor 62 ISDN Integrated Services Digital Network 82 ms millisecond 102 REP Request For Proposal 122 REP Request For Proposal 142 '', TB Tera Byte 3 AFE Above Finished Floor 13 CCITT Consultative Committee for International 4_S EF Entrance Facility 63 ISO International tional Organrzation for Standardization 83 MTBF _ Mean Time Between Failures 103 RFQ Request For Quotation 123 RFQ _ .Request For Quotation 14,5 _ TBB Telecommunications communications BackBoard 4 AEG Above Finished Grade 24 CCTV Closed Circuit Television 44 EGP Exterior Gateway Protocol 6 4 ISP _ Internet Service Provider 84 MPLS Multi Protocol Label Switching 104 RFR RE Equipment Rack 124 RFR RE Equipment Rack 144. TCP _ Transmission . Control _ Protocol..... 5 AFSF ,Above Finished Stage Floor 25 CDDI Copper Gistnbuted Data Interface 45 EIA .Electronics Industries Association 6 5 LAN Local Area Network 85 OC Optical Corner 105: RIP ,Routing Information Protocol 115. RIP . _ _.i_ Routing Information Protocol 145 TCP/IP / Transmission ., Control Protocol/Internet 6 AM 'Amplitude Modulation 26 CH Counter Height 46 EMI Electromagnetic Interface 66 LANE LAN Emulation 86 OFE Owner Furnished Equipment 106 RMON Remote Monitor 126 ! RMON Remote Monitor 146 TIA Telecommunications Industries Association 7 ANSI American National Standards Institute 27 CLEC Competitive Local Exchange Carrier 47 ER Equipment Room 67 LASER Light Amplification by Stimulated Emission of 87 OF01 Owner Furnished, Owner Installed 107 ROM Read Only Memory 127 ROM Read Only Memo ry 147 TO Telecommunications Outlet 8 ASME American Society of Mechanical Engineers 28 CPE Customer- Premises Equipment 48 ETSI European Telecommunications Standards 68 LAT Local Area Transport 88 OSI Open Systems Interconnection 108 SBB Security system BackBoard 128 SBB Security system BackBoard 148 TR Telecommunications Room 9 ASTM American Society f Testing Materials Y 9 29 CPU Central Processing Unit 9 49 FB Floor Box 69 LATA Local Access and Transport Area P 89 PAN Personal Area Network 109 SC Sound Cabinet' screw cover 129 SC Sound Cabinet; screw cover 149 LION Unless Otherwise Noted to ATM Asynchronous Transfer Mode 3o CSA Canadian Standards Associations 50 FCC Federal Communications Comission 70 LEC Local Exchange Carrier 90 PAR Public Address Rack 110 SCR Security Equipment Rack 130 SCR Security Equipment Rack 150 VCR Video Cassette Recorder 11 AVR Audio Visual Rack 31 CSMA /CA' Carrier :,ense Multiple Access with Collision 51 FDDI Fiber Data Distributed Interface 71 LED Light Emitting Diode ! 91 PAY Pa Telephone Location Y p 111 SJB ! Speaker Junction Box P 131 SJB :Speaker Junction Box 15 1 VoIP Voice o e over Internet Protocol 12 AWG American Wire Gauge 32 CSMA /CD: Carrier —Sense Multiple Access /Collision 52 GAN Global Area Network 72 LI Local (AV) Input 92 pps Packets Per Second 112 SCJB Security Camera Junction Box 132 SCJB Security Camera Junction Box 152 W _ Wall Mounted Device 13 BFC Below Finished Ceiling 33 CSU _ Channel Service Unit 5_5 GB Giga Byte 73 LO Local (AV) Output 9.5 PRI Primary Rate Interf ace 113 SMTP Simple Main Transfer Protocol 133 SMTP _ Simple Main Transfer Protocol 153: WAN Wide Area Network 14 BGP Border (Boundary) Gateway Protocol 34 CT Communications Technology 54 Gb /s _ (Gbps) Gigabits per second 74 MAC Media Access Control 94 PSTN Public Switched Tele hone Network P 114 SNA S stems Network Architecture Y 134 SNA _e Systems Network Architecture 154 WAP Wireless Access Point 15 BICSIBuildm Indust Consulting Services 9 Industry 9 35 CTC Communications Technology Contractor 9Y 55 GHz Gi aherfz 9 5 MAN Metropolitan Area Network 95 QoS Quality of Service Y 115 SNMP Simple Network Management Protocol P 9 135 _ SNMP Simple Network Management Protocol P 155 WG Wire Guard a 16 BIT Binary digit 36 db Decibel 56 HC Horizontal Cross — connect 76 MB _... Mega Bytes 96 RAID Random Array of Inexpensive Disks 116 SONET Synchronous Optical Network 136 SONET Synchronous Optical Network 17 BOM Bill of Material 37 DSL Digital Subscriber Line g 57 IC Intermediate Cross — connect 77 Mb /s / Megabits per second g p 97 RAM Random Access Memory 117 SP ! I Service Provider Service Provider (Also Local ) 137 SP Service Provider Also Local Service Provider ( ) 18 BPS Bits per second _ 38 DSU Data Service Unit /Digital Service Unit 58 IDF Intermediate Distribution Frame (Replaced by 78 MC Main Cross—connect _ 98 RBOC Regional Bell Operating Company 118 SR _ Strike Release Door 138 SR _ Strike Release Door 19 BRI Basic Rate Interface (ISDN) 39 DTE _ Data Terminal Equipment 59 IEEE Institute of Electrical and Electron ics 79 MDF Main Di .__ stribution Frame (Also see ER) 99 _. RE ._ Radio Frequency 119 SSR _._ ,Sound System Rack 139. SSR : ,Sound System Rack 20 CAD Computer Aided Design 40 DTR Data /Telecommunications Rack 60 IP Internet Protocol 80 MHz Megahertz 100 RFC Request For Comment 120 TAAC To Above Accessible Ceiling 140 TAAC To Above Accessible Ceiling PLO. a"N., yi::iflo Conduit ROUGH411 STANDARD OF QUALITY 15112 101 (4) Width Ncrewse t6t Tree 'Sift With L thi Depth 'I I � k , ALTERNATE I oN v ( ;R (:AI 1/ rnm (in) W .1.. r ;1`• d CONDUITS CONDUITS 4's „! A , l inx lk I ( ly h)1/1 1 4” 4" I /+" TWO TRADE SIZE 1 ONE TRADE SIZE 1 1/d 4 "E ^XCnVER[SNC'E' T&B E_C "Y 520:1458 4" 58" 4 "E"XC WE [5 V _ &� 7EE_C "Y 52114 4" 4" 6'X )VER jS V,_ L' &B ST-E' l- C' -Y 52015 4" V = VOLUME CONTROL " X = 1 -9 SPEAKER TYPE 4 "BC.X COVER [ r_E3LE' _ STS E_C'TY 520185,825 4" WALL MOUNTED SPEAKER (SURFACE MOUNTED) 4 °80X0; V E R jDCUELEI T &B STEELC TY 52C18 ' VX(V) V = VOLUME CONTROL E / T703 S 4 "KX::)VI H i.)OUIfI &!3 S!! I ("IY i11:1q 4" INTERCOM STATION (TWO WAY) _V: �,dA(:I Is'N(:u "i &Ii Si: 1 (, ".Y IZS'6C(; 4" r" SEE SYSTEMS DIAGRAM FOR CABLING REQUIREMENTS I Y rcP X I / T771 n'UA',;� ';OX &ii 5.. I . ;.,':Y I'll /1 1 4 ' 1/16.. i. "/6" 7 ' t" TWO TRADE S12E 1 ONE TRADE SIZE 1 IM 4 "1/1) ;X( ^VI hIN( R 3 I I ( IY /)(:1Fif,,R 41/16' t "./6 •)A' 4'1/16"I X( 7M ISM Ri S '..! I ( ".Y Pl('18 4 1/16' 4 CEILING MOUNTED CAMERA 4`I/l6 IL;X('.VI,ItiiN( _ k3.,',!I iY /'I('1 4'1/6 4'lj6' X = (1 -9) ENCLOSURE TYPE, Y = (A -Z) CAMERA TYPE 4 "I/11)' II ^r (� it { VI ', 10.. •1' &!i `( I .. :.:IY PJ('14',A 4'.1/16," 4 "/6° E,A" ADDITIONAL SUBSCRIPTS: PTZ = PAN TILT ZOOM 4'1/11) "FSX'- VER S'EE_C'Y 72014 4'1/16" 4 "./6" 3^" Y 4'1/16 [,-;XCOvER T&B �7EE�C'TY 72C15 4"1/16' 41',/6" " 4 ' 1,46 '6CX CVR � 'R'FAC [SIN;_'_E 78,3 S7EEL C'Y RSL16 4 ' 1/11)„ r ''/'6" '/2' 411/6 [i -XCVR SURFAC" [DOJELE 7&3 STEELC'TY RSL17 4'1/16" 4 11/6" 11" BUILDING EXTERIOR CAMERA d.' AN', I K X & i S; i I I ' Y 31 i:) sA ' 4 P" 81,,8" > ' ,p" TWO TRADE SIZE 1 ONE TRADE SIZE 1 1/,d 3'.)i VIC'. COV! !t U SII i l . I'i.Y .91C 4 PENDANT MOUNTED CAMERA (OUTDOOR ENCLOSURE) ;v(.I 11 v:cl W::oNnr ICx &11 I 1 r fW 1i,Nu� 3 3/1 6" 3 ONE TRADE SIZE 1 "ONE TRADE SIZE11l W_ V( MA OVARY I,"X U I 'y W I S,:: S S/ ' .i ' D ' TWO TRADE WE 1 ONE TRADE SIZE 1 1/,d I VIR I MA,,r1,A,, , ;ox kit I ( Y W.W , X = 1 -9 - DOOR TYPE; SEE DETAIL 9/ D" TWO TRADE SIZE 1 ONE TRADE SIZE 1 1/dc PLO. a"N., yi::iflo Conduit 2:v3 fll) 15112 101 (4) Width Ncrewse t6t Tree 'Sift With L thi Depth Aiddlitio"I Conduit rwm Cin) 1mm (in) MM (in) flirt'! (in) rnm (in) { Y.1 101(4) 406 (16' ) 761 ,3) 51 (2) X = 1 -9 SPEAKER TYPE PENDANT MOUNTED SPEAKER (OPEN CEILING) �x v H / T703 V = VOLUME CONTROL 41 2:v3 fll) 15112 101 (4) 301 (4) {r) 2,D3 T ?014 (3 6) 101(4,� :.? 7 (5) X63 (2 -1r 1) 154 (10) 1067% (42-) ill.7 �1j, j__ X61 16 ri) 10jr4 (1-.) 1220 (48) 1­1 �5 (6 CEILING SPEAKER 305 (12) 1370 (541 152 (6) D / T703 100 (41 381,15) 15 5 (60) 1 ►31 203 (S) TELECOMMUNICATIONS ROUGH -IN NOTES: 1) CONTRACTOR SHALL USE THESE DRAWINGS IN CONJUNCTION WITH THE SPECIFICATIONS TO DETERMINE THE FULL SCOPE, INTENT AND REQUIREMENTS OF THE PROJECT. SPECIFICATIONS AND DRAWINGS ARE INTENDED TO BE COMPLEMENTARY, NOT MUTUALLY EXCLUSIVE. WORK SHOWN ON THE DRAWINGS BUT NOT LISTED IN THE SPECIFICATIONS, AND WORK DESCRIBED IN THE SPECIFICATIONS BUT NOT SHOWN ON THE DRAWINGS SHALL BE INTERPRETED AS THOUGH WORK WERE FULLY DESCRIBED IN BOTH PLACES. THE HIGHER QUANTITY, HIGHER QUALITY, MORE LABOR INTENSIVE AND OVERALL MORE STRINGENT AND MORE COSTLY REQUIREMENT SHALL APPLY. 2) WHERE CONDUIT IS SHOWN AND /OR SPECIFIED, CONTRACTOR SHALL PROVIDE ALL PULL BOXES SHOWN ON THE DRAWINGS, PLUS ADDITIONAL PULL BOXES AS FOLLOWS: A) EVERY 180 DEGREES OF CONDUIT BEND; B) EVERY 100 FEET OF CONDUIT PATH. 3) ALL PULL BOXES AND JUNCTION BOXES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS. 4) ALL ROUGH -IN REQUIREMENTS, INCLUDING BUT NOT LIMITED TO MOUNTING HEIGHTS, BACK BOX SIZES, AND CONDUIT PATHS, AS THEY MAY BE INDICATED ON PLANS, DETAILS AND ELEVATIONS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS LISTED ON THE LEGEND. QUANTITIES AND SIZES OF CONDUITS ARE PER LEGEND UNLESS EXPRESSLY LISTED ON THE DRAWINGS. 5) PROVIDE PATHWAYS FOR CABLING ROUGH -IN BOXES FOR ALL COMMUNICATION TECHNOLOGY WORK, UNLESS OTHERWISE NOTED. 6) ROUGH -IN SHALL BE CLOSELY REVIEWED AND COORDINATED PRIOR TO INSTALLATION, TO BE CERTAIN THAT THE TYPE AND LOCATION OF ALL ROUGH -IN AND PATHWAY PROVISIONS WILL ADEQUATELY SUPPORT THE PRODUCTS TO BE INSTALLED. ANY COSTS INCURRED RESULTING FROM A FAILURE TO ADEQUATELY COORDINATE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 7) RESERVED. 8) PROVIDE COVER PLATES FOR ALL DEVICE, JUNCTION AND PULL BOXES. COORDINATE MATERIAL AND FINISH OF ALL BLANK PLATES TO MATCH SURROUNDING PLATES. 9) WHERE DEVICE CONDUITS ARE SPECIFIED "TAHC" (TO ABOVE ACCESSIBLE CEILING) THIS SHALL MEAN THAT CONDUITS SHALL BE STUBBED OUT INTO AN ACCESSIBLE CEILING CAVITY WITHIN THE SAME ROOM AS THE DEVICE WHICH THE CONDUIT SERVES. SEE ALSO "GENERAL DEFINITIONS." 10) WHERE DEVICE CONDUITS ARE SPECIFIED "TAHC" (TO ABOVE ACCESSIBLE HALLWAY /CORRIDOR CEILING) THIS SHALL IMPLY THAT CONDUITS SHALL BE RUN CONTINUOUS AND STUBBED OUT INTO AN ACCESSIBLE CEILING CAVITY WITHIN THE NEAREST CORRIDOR FEATURING AN ACCESSIBLE CEILING CAVITY. SEE ALSO "GENERAL DEFINITIONS." 11) CONDUIT PROVIDER SHALL PROVIDE PULL STRINGS INSTALLED IN ALL CONDUITS INCLUDING THOSE PROVIDED FOR IMMEDIATE AND FUTURE USE. 12) WHERE AMOUNTING HEIGHT MEASUREMENT IS APPLIED TO A ROUGH -IN, THE MEASUREMENT SHALL BE REFERENCED TO THE CENTER OF THE ROUGH -IN DEVICE. 13) MUD /PLASTER/TRIM RINGS AND MASONARY BOXES SHALL BE MOUNTED SO AS TO BE RECESSED 1/16T" TO 1 /8T" INCH TO ASSURE FACEPLATE FIT. 14) COMMUNICATION TECHNOLOGY DEVICE ROUGH -IN BOXES SHALL BE INSTALLED FLUSH IN WALLS AND CEILINGS. PATHWAYS SHALL BE INSTALLED CONCEALED. 15) ALTER ROUGH -IN MOUNTING HEIGHT TO EXACTLY MATCH ELECTRICAL OUTLET HEIGHT. 16) NOT USED 17) EXPOSED CONDUIT NOT BE PERMITTED IN FINISHED AREAS. 18) SPECIFIC HEIGHTS NOTED ON FLOORPLANS SHALL SUPERCEDE TYPICAL DETAILS RESERVED. 19) ROUGH -IN PROVIDER SHALL PROVIDE ALL WALL /FLOOR PENETRATIONS AND FIRE STOPPING REQUIRED FOR CABLING THAT MUST TRANSITION FROM SURFACE RACEWAY TO ACCESSIBLE CEILING CAVITIES. 20) ALL CONDUIT PROVIDED FOR COMMUNICATION TECHNOLOGY USE SHALL BE PROVIDED WITH NYLON END - BUSHINGS. BUSHINGS SHALL BE INSTALLED AT EACH END OF THE CONDUIT; AT EACH PULL /JUNCTION /DEVICE BOX; ON CONDUIT STUBS; AND AT EACH LOCATION WHERE PULLING CABLE THROUGH THE CONDUIT MAY CAUSE THE CABLE TO RUB AGAINST THE END OF A CONDUIT OR ITS END FITTING. 21) DEVICES DESIGNATED WITH THE "CH" SUBSCRIPT (COUNTER HEIGHT) SHALL BE CLOSELY COORDINATED IN THE FIELD WITH ARCHITECT /PROJECT MANAGER, CASEWORK AND FURNITURE VENDORS PRIOR TO ROUGH -IN. 22) DEVICES TO BE INSTALLED AT CASEWORK LOCATIONS SHALL BE CLOSELY COORDINATED WITH THE CASEWORK TO ENSURE FUNCTIONAL CONNECTIVITY. COORDINATE WITH THE ARCHITECT AND THE EQUIPMENT AND CASEWORK DRAWINGS. 23) ALL COMMUNICATION TECHNOLOGY ROUGH -IN SHALL BE CLOSELY COORDINATED IN THE FIELD TO COMPLEMENT THE INTENDED FURNITURE PLAN AND SAFE AND EFFICIENT CONNECTIVITY OF COMMUNICATION TECHNOLOGY EQUIPMENT. 24) MANY COMMUNICATION TECHNOLOGY DEVICES ARE INTENDED TO HAVE ADJACENT POWER OUTLETS TO SERVE THE SAME EQUIPMENT. CLOSE PROXIMITY OF THESE DEVICES IS CRITICAL TO USABILITY AND AESTHETICS. CONTRACTOR SHALL COORDINATE THESE DEVICES TO BE LOCATED ADJACENT AND AT THE SAME HEIGHT. 25) COMMUNICATION TECHNOLOGY DEVICE MOUNTING HEIGHTS SHALL BE CONSISTENT WITH THE ELECTRICAL OUTLET MOUNTING HEIGHTS FOR THE FACILITY (NEW OR EXISTING) UNLESS OTHERWISE INDICATED ON DRAWINGS. CONTRACTOR SHALL SEEK THE DIRECTION OF THE DESIGNER SHOULD DISCREPANCIES BE FOUND WITHIN THE DRAWINGS, SPECIFICATIONS AND /OR ACTUAL FIELD CONDITIONS. 26) THE ELEVATOR TELEPHONE CONNECTION (ELEV), SHALL BE COORDINATED WITH THE INSTALLING ELEVATOR CONTRACTOR. PROVIDE CONDUIT FROM THE ELEVATOR CONTROL PANEL TO THE CORRIDOR CEILING SPACE, UNLESS OTHERWISE INDICATED ON THE DRAWINGS. PROVIDE THE CABLING AND CONNECTIVITY AS REQUIRED. 27) COORDINATE THE TELEPHONE CONNECTION REQUIREMENTS FOR THE FIRE ALARM CONTROL PANEL (FACP) WITH THE INSTALLING FIRE ALARM CONTRACTOR. PROVIDE CONDUIT FROM THE FACP TO THE ACCESSIBLE CORRIDOR CEILING SPACE, UNLESS OTHERWISE INDICATED ON THE DRAWINGS. PROVIDE THE CABLING AND CONNECTIVITY AS REQUIRED. 28) COORDINATE THE DATA REQUIREMENTS FOR HVAC BUILDING AUTOMATION SYSTEM (BAS), INCLUDING LOCATION, WITH THE MECHANICAL CONTRACTOR. PROVIDE THE CABLING AND CONNECTIVITY AS REQUIRED. 29) ALL CONDUITS STUBBED INTO THE CEILING CAVITY SHALL BE MARKED WITH AN INDELIBLE MARKER INDICATING THE CONDUIT'S INTENDED USE. MARK CONDUIT SO AS TO BE READABLE FROM BELOW. LABEL WITHIN 6 INCHES OF THE CONDUIT BUSHING. BELOW OF EXAMPLES OF LABELS TO BE USED. "CAMERA," "ICOM," "DOOR," "SPKR," "MIC," "CLOCK," "VOL," "PANEL," "WAR" "DATA," "PHONE," "COM," "RF," "VP," "INPUT," ETC. 30) WHERE A CONDUIT (ROUGH -IN) IS SHOWN TO EXTEND TO A TELECOMMUNICATIONS /IT ROOM FROM A DEVICE/ OUTLET LOCATION IN THE PARKING AND PLAZA LEVELS, THE CEILING MOUNTED "ZONE" JUNCTION BOXES ON THE PARKING LEVEL SHALL BE UTILIZED TO CONSOLIDATE INDIVIDUAL COUNUIT RUNS. TELECOMMUNICATION TECHNOLOGY LEGEND (CONTINUED) DISTRIBUTED SOUND AND INTERCOM VOLUME CONTROL 0 G / T703 CEILING SPEAKER X Ov D / T703 V = VOLUME CONTROL X = 1 -9 SPEAKER TYPE PENDANT MOUNTED SPEAKER (OPEN CEILING) �x v H / T703 V = VOLUME CONTROL X = 1 -9 SPEAKER TYPE S ADDITIONAL SUBSCRIPTS: WP = WEATHERPROOF X(V) WALL MOUNTED SPEAKER (FLUSH MOUNTED) vq\ F / T703 V = VOLUME CONTROL X = 1 -9 SPEAKER TYPE ADDITIONAL SUBSCRIPTS: WP = WEATHERPROOF WALL MOUNTED SPEAKER (SURFACE MOUNTED) ' VX(V) V = VOLUME CONTROL E / T703 S X = 1 -9 SPEAKER TYPE x( ADDITIONAL SUBSCRIPTS: WP = WEATHERPROOF INTERCOM STATION (TWO WAY) I / T703 SEE SYSTEMS DIAGRAM FOR CABLING REQUIREMENTS TENANT COMMUNICATIONS PANEL (INTERCOM) rcP X I / T771 SEE TENANT INTERCOM SYSTEM DIAGRAM FOR CABLING INFORMATION X = INDICATES SIZE OF ROUGH -IN WHEN NECESSARY WALL MOUNTED CLOCK E I T703 SEE SYSTEMS DIAGRAM FOR CABLING REQUIREMENTS SECURITY SYSTEM AND CCTV CEILING MOUNTED CAMERA F / T771 ADDITIONAL SUBSCRIPTS: PTZ = PAN TILT ZOOM X = (1 -9) ENCLOSURE TYPE, Y = (A -Z) CAMERA TYPE WALL MOUNTED CAMERA (INDOOR) XY �— C E / T771 ADDITIONAL SUBSCRIPTS: PTZ = PAN TILT ZOOM X = (1 -9) ENCLOSURE TYPE, Y = (A -Z) CAMERA TYPE PENDANT MOUNTED CAMERA (INDOOR) Y F / T771 ADDITIONAL SUBSCRIPTS: PTZ = PAN TILT ZOOM X = (1 -9) ENCLOSURE TYPE, Y = (A -Z) CAMERA TYPE POLE MOUNTED CAMERA POLE J / T771 ADDITIONAL SUBSCRIPTS: PTZ = PAN TILT ZOOM X - (1 -9) ENCLOSURE TYPE, Y - (A -Z) CAMERA TYPE (ENCLOSURE SHALL INCLUDE HEATER) BUILDING EXTERIOR CAMERA EXT X I / T771 ADDITIONAL SUBSCRIPTS: PTZ = PAN TILT ZOOM X = (1 -9) ENCLOSURE TYPE, Y = (A -Z) CAMERA TYPE (ENCLOSURE SHALL INCLUDE HEATER) PENDANT MOUNTED CAMERA (OUTDOOR ENCLOSURE) F / T771 ADDITIONAL SUBSCRIPTS: PTZ = PAN TILT ZOOM X X = (1 -9) ENCLOSURE TYPE, Y = (A -Z) CAMERA TYPE (ENCLOSURE SHALL INCLUDE HEATER) SECURE DOOR [SD ]X E / T771 X = 1 -9 - DOOR TYPE; SEE DETAIL EMERGENCY PANIC SWITCH �EPS F / T701 SEE SYSTEMS DIAGRAM FOR CABLING REQUIREMENTS G i i CA Ravi E ti i1 I i ks. 1! I� i 1 •. � 11 � I� DYN it1: I ! 1 i f I i r- L ,�1. 1 ( I J L2 1! 11 1 11 9 10 E a ,;t 56'.h Save': SUlF E 2155 ii')DiANAPOL:S, !tv 46216 ?^;;,5 ar 338 317,524 6339 FA, -1 : 4"Fi.r ec, flcllyn cc . P E D C O R ? � P � �etw� DEVELOPMENT CO. - r y z " zii' •"" it L 14.6 4 P.L ;1 titi: -tok. ,J �4x rte, 1 � fs+.l F.sLi � -- ! ✓f. , 8 LEGEND T00�