HomeMy WebLinkAboutT201COLUM N i I Ili I i I I !I II I I II f I 84 in. I VIII I ! i I I I� ! I I I ! �� II i ! WEST WALL ELEVATION - ENTRANCE FACILITY Scale: 1/2" = 1' a 1 ft. EAST WALL ELEVATION - ENTRANCE FACILITY Scale: 1/2" = 1' NORTH Scale: 1/2" = 1' WALL ELEVATION - ENTRANCE FACILITY SOUTH WALL ELEVATION - ENTRANCE FACILITY Scale: 1/2" = 1' STALLATION NOTES: THIS SHEET) 1 } ENLARGED FLOOR PLAN ARE PRESENTED DIAGRAMMATICALLY. ALL DIMENSIONS SHOULD BE VERIFIED IN THE FIELD. 2) CABINETS SHALL HAVE A MINIMUM OF 30" CLEARANCE IN FRONT AND REAR OF EACH CABINET. 3) RACKS SHALL HAVE A MINIMUM OF 40" CLEARANCE IN REAR AND 24" IN FRONT OF EACH RACK. 4) TELECOMMUNICATIONS BACKBOARDS SHALL BE ATTACHED TO THE WALL IN POSITIONS AS SHOWN IN THE ENLARGED FLOORPLAN DETAILS. 5) STANDARD TELECOMMUNICATIONS BACKBOARDS SHALL BE 4' WIDE BY 8' TALL. EACH BACKBOARD SHALL BE 3/4" A —C GRADE PLYWOOD COATED ON THE EXPOSED FRONT AND ALL EDGES WITH 2 COATS OF WHITE FIRE — RETARDANT PAINT. 6) EACH BACKBOARD SHALL BE MOUNTED VERTICALLY UTILIZING THREE BOLTS (TOP, MIDDLE, AND BOTTOM) OF EACH STUD IN WALL. BACKBOARDS SHALL BE MOUNTED WITH THE BOTTOM EDGE SQUARE AND LEVEL %" ABOVE THE BASEBOARD OR 6" ABOVE FINISHED FLOOR (WHICHEVER IS LOWER). 7) WHERE A FULL SIZE BACKBOARD CANNOT BE UTILIZED, A STANDARD BACKBOARD SHALL BE CUT TO FIT THE SPACE. ALL EDGES SHALL BE RE— PAINTED. 5) WHERE BACKBOARDS ARE MOUNTED OVER DEVICES (SUCH AS SWITCHES AND OUTLETS) THE BACKBOARD SHALL BE CUT TO ALLOW THE ENTIRE DEVICE TO BE REVEALED PLUS %4" TRIM SPACE ON EACH SIDE, 9) EACH BACKBOARD SHOWN ON THE ENLARGED FLOORPLAN SHALL BE NUMBERED AND CORRESPOND TO BACKBOARDS SHOWN ON THE DETAIL SHEETS. BACKBOARDS SHOWN ON THE FLOORPLANS BUT NOT DETAILED ON THE DETAIL DRAWINGS HAVE NO EQUIPMENT MOUNTING REQUIREMENTS UNDER THIS CONTRACT. 10) CONVENIENCE OUTLETS SHOWN SHALL BE QUAD 120V OUTLETS ON A 20A CIRCUITS) FROM BUILDING DISTRIBUTION PANELS. (BY DIVISION 16 ELECTRICAL CONTRACTOR). 1 1) COMMUNICATIONS (RACK /CABINET /BACKBOARD) SHALL BE FED FROM A SEPARATE PANEL IN THE EQUIPMENT ROOM (ER). ALL TELECOMMUNICATIONS ROOMS (TR) SHALL HAVE THE INDICATED CIRCUITS FROM THE BUILDING DISTRIBUTION PANELS. (BY DIVISION 16 ELECTRICAL CONTRACTOR). 12) 15 AMP CIRCUITS SHALL HAVE NEMA 5 -15R DUPLEX (DUAL IF QUAD INDICATED) RECEPTACLES. 20 AMP CIRCUITS SHALL BE NEMA 5 -20R DUPLEX RECEPTACLES. 30 AMP CIRCUITS SHALL BE NEMA L5 -30R (120V) OR L14 -30R (120/208V) (AS DIRECTED ON SELECTION OF EQUIPMENT) SINGLE RECEPTACLES. 4A4 CARM E L � D Y 4105 tas: Sethirc'ei SUP-r- 2150 ?NDIANAPi L-IS. IN 45i'.16 317.524 6339 FAX P E D C O R DEVELOPMENT CO. . w� S a i 06- 12 ROOM ELEVATIONS T 09W () I LS s` E;3T 2 ! it MF y �y �4 r .-:�'r k a9 ^xc . w� S a i 06- 12 ROOM ELEVATIONS T 09W () I