Loading...
HomeMy WebLinkAboutT701FLOOR; THICKNESS VARIABLE 6 in. CAP WHERE EXPOSED TO WEATHER; FIRESTOP FOR INDOOR USE �X CONDUIT(S) EXTEND TO NEAREST ER /TR OR X= CONDUIT TRADE SIZE ZONE CABLING JUNCTION POINT CONDUIT STUBS UP THROUGH FLOOR Scale = NONE TWO 2" CONDUITS SIDE VIEW HINGED i LOCKABLE COVER BOXES TO BE SUPPORTED FROM 4CORNERS SUPPORT FROM BUILDING STRUCTURE EVERY 5' WITH 3/8" THREADED ROD - —10. 5. 14.64' l 13.14' 5.5 in. H MOUNT FLUSH IN CEILING , 1 10" Ceiling Mount Erg;fosure W 1000 -WCE WA CM TYPICAL CEILING MOUNTED ENCLOSURE (WAS Scale = NONE SUPPORT FROM BUILDING STRUCTURE ON 4 CORNERS LOCKABLE 1 ' 11V COVER CEILING 14.b4- 5.00 1j.1411 � f 4 �- 1.001 ._� 5"' Coiling Mourit Enclosure W 1 0{0 -WC 5 WAP CE TYPICAL CEILING MOUNTED WIRELESS ENCLOSURE (WAP) Scale = NONE CONDUIT SHALL EXTEND CONDUIT SHALL EXTEND WALL TO ELECTRICAL PANEL COLL M TO ELECTRICAL PANEL -- ----- - - - - -- BUILDING , `/ SUPPORT ------------- - - - -IH - - + -- -------- - - - - -- STRUCTURE CEILING LINE II 11 CONDUIT SHALL EXTEND II II TO ACCESSIBLE CEILING CONDUIT SHALL EXTEND II II II II CAVITY OR DESTINATION - TO TELECOM CEILING II �� CABINET JUNCTION BOX II II � II II 4 11/16" SQUARE 2.5" DEEP BOX FOR II II STROBE MOUNTING II II II II II II II II MINIMUM 1" CONDUIT / MINIMUM 1" CONDUIT II II II II FLUSH MOUNTED CUSTOM BACKBOX II �� CUSTOM BACKBOX #EPT -SML with EPT- II 11 / #MS -100 120 in PMKT mounting kit II II / BY TALK -A PHONE BY TALK -A PHONE II II 42" A.F.F UNLESS 42" A.F.F UNLESS OTHERWISE NOTED OTHERWISE NOTED � 1 EC . I:IEC TYPICAL EMERGENCY PHONE ROUGH -IN Scale = NONE SAFETY LOOP TO BUILDING STRUCTURE SHALL ALLOW DEVICE TRAVEL NO MORE THAN 6" BELOW CEILING GRID IF PRIMARY CABLE SUPPORT SHALL BE SUPPORTS FAIL TYPICAL BUILDING STRUCTURE LOCATED IN CLOSE PROXIMITY TO ROUGH -IN (ADJUST MOUNTING AS NECESSARY) Q TO PROVIDE SUPPORT FOR SERVICE LOOP 2" STRUT CONSTRUCTION BETWEEN SUPPORT STRUCTURES; "AIRCRAFT" CABLE TO 4 CORNERS CABLE(S) TO ER/TR OF ENCLOSURE TO SUPPORT OR INPUT OUTLET WEIGHT; CEILING GRID FOR LOCATION ALIGNMENT ONLY. - - - - - - -- ADJUSTMENT TURN BUCKLE ACCESSIBLE CEILING LINE SIDE VIEW Biala ems, cz -ap. r.: crn ti 'V -� 15' lrri T r._- I r - "lit l 1 �.� I I I" •nn t .r 1124 !ran , -,_ ) ! t3G ,y� i Y t i� a,at ,•�� `� raft yt `� I � ts. •rJ • -i r, ass •mn Hpi tw- nnrt..rx:h <r�: „t. n � -_ rn w...__:ev. ^nr, ± •il c :w.i!n•._ _. -__ (:ICpr +:Ppr t. PPrc 1•ara:Kr .0.f i11 ^! I � PP ra-.h IIQ!r nM IDn 4_i1CC. T.nth t�T S.A _y I ra n•n it. v r, r, EE r / I R � nni• n3 Max:n„�n fu nr� ^G resin wn• an gosrrlr[ebn •� _ . NO-1E5 X Am, be_635 auu ( ^c 1U), Z;La11 be_X'Wbw 3:_ Rz ws W� m"m uae renen mrr obatvRwn {�D inF, r6au!' sLa:i t e 2 _�: uuu l4S :cj max;uwza'Jl3uu X is :•:•d to 6:: nsw C.0 -' � m), tic':LaU be l:i.lrnn f;i x1 tnswnius NOTE. The = =ualungt1tortJele<mcal and caau v=.stioasmstem Fot addrfims: infw mam,.etecmCSapseca Hainals U•utibedoe ieceprxles oa palls (e..t m:es andja;W sns: be 381 nun (.: in) ;ysuzns. SW4 thuu3e3'low 1AFF ADA COMPLIANT PAY TELEPHONE Scale - NONE CEILING MOUNTED PAN MOUNTS IN 2'x 2' CEILING GRID WITH SUPPORT BOTTOM VIEW F LOOKING UP AT FROM BUILDING CEILING STRUCTURE SUBSCRIPTS TO SYMBOLS MODIFY RC CABLING REQUIREMENTS AND DO NOT ALTER ROUGH -IN REQUIREMENTS (EXCEPT AS DETAILED) TYPICAL CEILING MOUNTED REMOTE CABINET Scale = NONE TYPICAL BUILDING STRUCTURE (ADJUST MOUNTING AS NECESSARY) SINGLE PORT SURFACE HOUSING COMPLETELY WRAPPED WITH UNIFRAX FYREWRAP 0.5 PLENUM RATED CAT 6 PATCH CABLE (RJ45) CLIPPED TO SUPPORT CABLE(S) TO ER/TR CEILING LINE UTILIZE CADDY SPEED LINK TO SUPPORT DEVICE CONDUIT ELBOW SHALL TURN -OUT CONDUIT SHALL EXTEND TO AT APPROXIMATELY 6" ABOVE ACCESSIBLE CEILING CAVITY WITHIN ACCESSIBLE CIELING OR ADJACENT TO SPACE SERVICED II II ZZ MINIMUM ONE 1" CONDUIT MINIMUM ONE 3/4" II II II CONDUIT II II 4" SQUARE BOX 2 1/8" DEEP CEILING LINE WITH 3/4" SINGLE DEVICE II (TRIM, PLASTER, MUD) RING OUTLET BOX SHALL BEIlll OR SINGLE GANG BOX MOUNTED AT +96" AFF 06 6" 6 in. OC BELOW CEILING LINE OTHERWISE NOTED CEILING LINE WAP TYPICAL CEILING MOUNTED ROUGH -IN (ACCESSIBLE CEILING) Scale = NONE CONDUIT ELBOW SHALL TURN -OUT AT APPROXIMATELY 6” ABOVE ACCESSIBLE CEINING CEILING LINE I_ CABLE SUPPORT SHALL BE LOCATED IN CLOSE PROXIMITY TO ROUGH -IN TO PROVIDE SUPPORT FOR SERVICE LOOP CABLES TO I DESTINATION 11 II CONDUIT SHALL EXTEND TO II ACCESSIBLE CEILING CAVITY WITHIN II h OR ADJACENT TO SPACE SERVICED II II AND MARKED WITH INDELABLE MARKER II II MINIMUM ONE 3/4" II II II CONDUIT II II 4" SQUARE BOX 2 1/8" DEEP A WITH 3/4" SINGLE DEVICE II (TRIM, PLASTER, MUD) RING II I�- OR SINGLE GANG BOX 1 OTHERWISE NOTED 44" A.F.F UNLESS OTHERWISE NOTED W "W'• SUBSCRIPT MODIFIES CABLING AND PS "PS" SUBSCRIPT MODIFIES CABLING AND . ROUGHEN REQUIREMENTS 120 in. CABLE SUPPORT SHALL BE LOCATED IN CLOSE PROXIMITY TO ROUGH -IN TO PROVIDE SUPPORT FOR SERVICE LOOP CABLES TO DESTINATION CABLES TO DESTINATION CONDUIT SHALL EXTEND TO �A ACCESSIBLE CEILING CAVITY 6 WITHIN OR ADJACENT TO SPACE \ SERVICED AND MARKED WITH INDELABLE MARKER \ 4" SQUARE BOX 2 1/8" DEEP WITH 3/4" SINGLE DEVICE 96 in. (TRIM, PLASTER, MUD) RING OR SINGLE GANG BOX SUBSCRIPTS TO SYMBOLS MODIFY WAP CABLING REQUIREMENTS AND DO NOT ALTER ROUGH -IN REQUIREMENTS (EXCEPT AS DETAILED) TYPICAL OUTLET DEVICE ROUGH -IN Scale = NONE CONDUIT SHALL EXTEND TO ACCESSIBLE CEILING CAVITY OR DESTINATION CABINET CEILING LINE CONDUIT AND CABLE(S) SHALL EXTEND INTO EQUIPMENT FURNISHED BY OTHERS COORIDINATE PLACEMENT WITH EQUIPMENT y PROVIDER(S) ELEV BAS . V . FACP TYPICAL OUTLET DEVICE ROUGH -IN Scale = NONE CONDUIT ELBOW SHALL TURN- OUT AT APPROXIMATELY 6" ABOVE ACCESSIBLE CEINING CEILING LINE CABLE SUPPORT SHALL BE LOCATED IN CLOSE PROXIMITY TO ROUGH -IN TO PROVIDE SUPPORT FOR SERVICE LOOP CABLES TO DESTINATION II �,Uivuvl l arlALL to I tNU l U II ACCESSIBLE CEILING CAVITY WITHIN II I I OR ADJACENT TO SPACE SERVICED 11 1I II AND MARKED WITH INDELABLE MARKER I I II I I MINIMUM TWO 1" CONDUITS II I I 4" SQUARE BOX 2 1/8" DEEP MOUNTING \ WITH W SINGLE DEVICE II (TRIM, PLASTER, MUD) RING OR HARDWARE i SINGLE GANG BOX rII FASTENING DEVICES 48" A.F.F UNLESS OTHERWISE NOTED s " •3 K W "W'• SUBSCRIPT MODIFIES CABLING AND �EPS v ROUGH -IN REQUIREMENTS TYPICAL WALL OUTLET DEVICE ROUGH -IN Scale= NONE CABLE SUPPORT SHALL BE LOCATED IN CLOSE PROXIMITY TO ROUGH -IN TO PROVIDE SUPPORT FOR SERVICE LOOP CEILING LINE CONDUIT ELBOW SHALL TURN- OUT AT APPROXIMATELY 6" ABOVE ACCESSIBLE CEINING i I i !C RME L PEDCOR DESIGN GROUP CABLES TO - DESTINATION \ jt� (lil j \ CONDUIT SHALL EXTEND TO ACCESSIBLE TECHI_I\j� CEILING CAVITY WITHIN OR ADJACENT TO is ,' - , . I `!' \ i ty I R 1' I I I I SPACE SERVICED AND MARKED WITH , �1 {Ul I U INDELABLE MARKER 9166 Ea:;' 56P1 Street 8Ui -7r- -11,:50 Ii�JDIAP4APOi !S. 1NI 56216 17.524 6' 39 FAX I � MINIMUM TWO 1" CONDUITS y, r �,,� 6.,;i• I 1 I 4" SQUARE BOX 2 1/8" DEEP WITH 3/4" TWO I DEVICE (TRIM, PLASTER, MUD) I RING 18" OC A.F.F UNLESS OTHERWISE NOTED X X RF VOC X pX SUBSCRIPTS TO SYMBOLS MODIFY . CABLING TER ROUGH-IN OT N (EXCEPT AS DETAILED) TYPICAL OUTLET DEVICE ROUGH -IN Scale = NONE SINGLE DEVICE TWO DEVICE MASONARY BOXES Scale = NONE a a I 3 GANG OUTLET BOX AND COVER Scale = NONE I i F SURFACE INSTALLATION SINGLE DEVICE TWO DEVICE I 1 F FLUSH INSTALLATION SINGLE TWO DEVICE DEVICE SQUARE OUTLET BOX & COVERS (4" AND 4 11/16 Scale = NONE BOXES MOUNT TO WALL WITH APPROVED FASTENING DEVICES DEVICE (TRIM, PLASTER, MUD) y` RINGS SHALL APPROXIMATE MINIMUM THE DEPTH OF THE WALL SEPARATION \ BOARD OR BE SLIGHTLY (1/16 ") % SHORTER TO PROVIDE BLOCK WALL 6 in.- . PROPER FACEPLATE MOUNTING FIRRING STRIPS CHANNEL WALL FOR TYPICAL DEMIZING/ BOX INSTALLATION WALL BOARD CORRIDOR WALL BOX MOUNTING SEE ELECTRICAL R SPECIFICATIONS FOR MINIMUM APPROVED BOX DEVICE (TRIM, PLASTER, MUD) SEPARATION (NEXT — BOXES MOUNT TO WALL MOUNTING \ WALL BOARD RINGS SHALL APPROXIMATE BLOCK) — WITH APPROVED HARDWARE i THE DEPTH OF THE WALL BLOCK WALL FASTENING DEVICES 16 in. BOARD OR BE SLIGHTLY (1/16 ") s " •3 K SHORTER TO PROVIDE PROPER FACEPLATE OO OO �� �� MOUNTING DEVICE (TRIM, PLASTER, MUD) RINGS TYPICAL 8" BLOCK SHALL APPROXIMATE THE DEPTH OF ` STUD SEPARATES TELECOM AND WALL (FLUSH — THE BLOCK SIDE OR BE SLIGHTLY (1/ TYPICAL STUD ELECTRICAL DEVICE BOXESOR A MOUNTED) 16 ") SHORTER TO PROVIDE PROPER WALL BOX MINIMUM OF 4" SEPARATION BETWEEN FACEPLATE MOUNTING MOUNTING STUDS OUTLET BOX MOUNTING TOP VIEW y Scale = NONE P E D C O R �1� �Je9ttex DEVELOPMENT CO. El- U ' I b" ROUGH -IN DETAILS '1'i01 R 40.11. s " •3 K LIU y L _ i J.. ooe El- U ' I b" ROUGH -IN DETAILS '1'i01