HomeMy WebLinkAboutT771OUTLET BOX IN
/ POLE BY
MANUFACTURER
f! �u
(TYPICAL) CAMERA, ENCLOSURE AND
MOUNTING HARDWARE TO BE
FURNISHED BY CCTV CONTRACTOR
E� PA-S
Xp,GC O R\OR
N GNE9 P N
v � ,o�s� -��o
CONAs
10
COORDINATE NECESSARY
SLEEVE IN POLE BASE TO
ALLOW CAMERA CABLING TO
UTILIZE POLE AS CABLE
PATHWAY
POLE
C
TYPICAL POLE MOUNTED CAMERA
Scale = NONE
_ ROOF OR SECOND
FLOOR DECK
a
CEILING j
i'
WHERE ABOVE UN- �
ACCESSIBLE CEILING, /
EXTEND CONDUIT TAAC
OR TO ERITR
1" CONDUIT STUBBED /
INTO ACCESSIBLE
CEILING WITH BUSHINGS
126 in.
EXTERIOR WALL
4 11/16" SQUARE
2.5" DEEP BOX FOR
DEVICE MOUNTING
(TYPICAL) CAMERA, ENCLOSURE AND
MOUNTING HARDWARE TO BE
FURNISHED BY CCTV CONTRACTOR
EXT �J
x
TYPICAL BUILDING EXTERIOR MOUNTED CAMERA
Scale = NONE
15A 120V POWER CIRCUIT AND
i L SEPARATE MOTOR CIRCUIT
1" CONDUIT TO
6 TELECOMMUNICATIONS ROOM
r i
�I
6"
TO MnTnR
CEILING LINE
SD 3
TYPICAL SECURE DOOR ROUGH -IN BY TYPE
Scale = NONE
BUILDING
SUPPORT
STRUCTURE
--------------- - - --
ANCHOR SECURELY WITH
LOCKNUTS TO SECURED
CONDUIT TO SUPPORT A
MINIMUM OF 20 POUNDS
MINIMUM' /."
CONDUIT
CONDUIT SHALL
EXTEND TO NEAREST
ACCESSIBLE CEILING
CEILING \�� 411116' SQUARE
` 2.5" DEEP BOX FOR
DEVICE MOUNTING
(TYPICAL) CAMERA, ENCLOSURE AND
MOUNTING HARDWARE TO BE
FURNISHED BY CCTV CONTRACTOR
HARD
CEILING
CEILING MOUNT DEVICE ROUGH -IN
Scale = NONE
CONDUIT SHALL EXTEND
TO ACCESSIBLE CEILING ,
CAVITY OR DESTINATION
CABINET
k
CEILING LINE
MINIMUM 3/" CONDUIT - -
4" SQUARE BOX 2"
DEEP WITH 3/"
SINGLE DEVICE; ;
RING
132 in.
106 in.
108 in.
TYPICAL BUILDING STRUCTURE
(ADJUST MOUNTING AS NECESSARY)
CABLE SERVICE LOOP
SUPPORTED ABOVE
ACCESSIBLE CEILING
CEILING LINE
6 in.
106 in.
1" CONDUIT TO
5 TELECOMMUNICATIONS
ROOM
SD 4
TYPICAL BUILDING STRUCTURE
(ADJUST MOUNTING AS NECESSARY)
SINGLE PORT SURFACE HOUSING
COMPLETELY WRAPPED WITH
UNIFRAX FYREWRAP 0.5
PLENUM RATED CAT 6 PATCH
CABLE (RJ45)
ACCESSIBLE
CEILING
�:E:�WALL MOUNTED DEVICE ROUGH -IN
Scale = NONE
\ / 2 \, \5�
C� �oR
120 in. 1��
108 in. "�\ON
�H ONS�Fz rTC
TC C
3 >ACCESS CARD READER , l 3 ACCESS CARD READER i I P I
q I LLLI
(3 \, DOOR ACTUATOR \/0OOR ACTUATOR
42 in. 42 in.
34 in. 34 in.
TCP X ACCESS CARD READER SHALL BE PLACED TcP x
ON THE HANLE SIDE OF SINGLE DOOR
AND PRIMARY DOOR SIDE OF DOUBLE
N,�Rp,NGEPPN�� DOOR CONFIGURATIONS; OORD NATE PNCEPANE�
w1 'ev E WITH DOOR HARDWARE SUPPLIER `P BASED E{.1SR
TENANT COMMUNICATIONS PANEL
Scale =NONE
"CEtLtN�t1T
6
-� 15A 120V POWER CIRCUIT 15A 120V POWER
CIRCUIT
1" CONDUIT TO — { ►1" CONDUIT TO
r TELECOMMUNICATIONS 5 -� TELECOMMUNICATION
ROOM r��l
4 –I — I� S ROOM
� 1
CABLE(S) TO ER/TR
CEILING LINE
(TYPICAL) CAMERA, ENCLOSURE AND
MOUNTING HARDWARE TO BE
FURNISHED BY CCTV CONTRACTOR
SD 2
5 /,
CEILING LINE
-� 108 in.
3 ,
42 in.
C6,
�6
'I,
—
ACCESS CARD READER SHALL BE PLACED ON THE
► 15A 120V POWER CIRCUIT
,�
15A 120V POWER
SIDE OF DOUBLE DOOR CONFIGURATIONS;
►
`
► CIRCUIT
\
THREE 2" CONDUITS TO
MINIMUM
THE DEPTH OF THE WALL
THE DEPTH OF THE WALL
TELECOMMUNICATIONS ROOM
` —
► 2" CONDUIT TO
SEPARATION
SHORTER TO PROVIDE
TELECOMMUNICATIONS ROOM
6 irt: -...
(5)
- - --_ -_
MOUNTING
CEILING LINE
\6/
0000 01901
\ / 2 \, \5�
C� �oR
120 in. 1��
108 in. "�\ON
�H ONS�Fz rTC
TC C
3 >ACCESS CARD READER , l 3 ACCESS CARD READER i I P I
q I LLLI
(3 \, DOOR ACTUATOR \/0OOR ACTUATOR
42 in. 42 in.
34 in. 34 in.
TCP X ACCESS CARD READER SHALL BE PLACED TcP x
ON THE HANLE SIDE OF SINGLE DOOR
AND PRIMARY DOOR SIDE OF DOUBLE
N,�Rp,NGEPPN�� DOOR CONFIGURATIONS; OORD NATE PNCEPANE�
w1 'ev E WITH DOOR HARDWARE SUPPLIER `P BASED E{.1SR
TENANT COMMUNICATIONS PANEL
Scale =NONE
"CEtLtN�t1T
6
-� 15A 120V POWER CIRCUIT 15A 120V POWER
CIRCUIT
1" CONDUIT TO — { ►1" CONDUIT TO
r TELECOMMUNICATIONS 5 -� TELECOMMUNICATION
ROOM r��l
4 –I — I� S ROOM
� 1
CABLE(S) TO ER/TR
CEILING LINE
(TYPICAL) CAMERA, ENCLOSURE AND
MOUNTING HARDWARE TO BE
FURNISHED BY CCTV CONTRACTOR
SD 2
5 /,
CEILING LINE
-� 108 in.
3 ,
42 in.
42 in.
L
'I,
—
ACCESS CARD READER SHALL BE PLACED ON THE
FASTENING DEVICES
sD 2 HANLE SIDE OF SINGLE DOOR AND PRIMARY DOOR sD
APPROVED BOX
SIDE OF DOUBLE DOOR CONFIGURATIONS;
SEPARATION (NEXT BOXES MOUNT TO WALL
COORDINATE WITH DOOR HARDWARE SUPPLIER
ANCHOR SECURELY TO 4 11/16" SQUARE
BUILDING STRUCTURE _ 2.5" DEEP BOX FOR
TO SUPPORT A MINIMUM DEVICE MOUNTING
– – – OF 20 POUNDS
- - - - -- ------ - - - - --
BUILDING
SUPPORT y
STRUCTURE
CONDUIT SHALL EXTEND
TO TR /IT ROOM
\ MINIMUM 3/"
CONDUIT
(TYPICAL) CAMERA, ENCLOSURE AND
MOUNTING HARDWARE TO BE
FURNISHED BY CCTV CONTRACTOR
ACCESSIBLE OPEN
CEILING CEILING
Y
C
BUILDING
SUPPORT
STRUCTURE
ANCHOR SECURELY TO
BUILDING STRUCTURE TO
SUPPORT A MINIMUM OF 20
POUNDS
KEYED NOTES:
OPEN FIXED
CEILING CEILING
1. LOCK/STRIKE POWER SUPPLY IN 6 "4"x4" JUNCTION BOX. MOUNT
ABOVE ACCESSIBLE CEILING ON SECURE SIDE OF DOOR.
2. 8x8x4 JUNCTION BOX. MOUNT ABOVE ACCESSIBLE CEILING ON SECURE
SIDE OF DOOR.
3. SECURITY DEVICE BACKBOX. 4" SQUARE BOX WITH SINGLE GANG
ADAPTER RING. FLUSH MOUNT IN WALL.
4.2" CONDUIT
5. 1" CONDUIT
6.3/4" CONDUIT
7. RESERVED
VA0 rem
A
J 5 f
r.
1" CONDUIT TO
TELECOMMUNICATIONS 5: -
ROOM -
5
\ S –
114 in.
42 in.
TWO DEVICE
MASONARY BOXES
Scale = NONE
A
e
jag
SD �
3 GANG OUTLET BOX AND COVER
Scale = NONE
1" CONDUIT TO
TELECOMMUNICATIONS
ROOM
i
.. z SURFACE INSTALLATION
SINGLE
DEVICE TWO DEVICE
FLUSH INSTALLATION
9
SINGLE TWO DEVICE
DEVICE
SQUARE OUTLET BOX & COVERS (4" AND
_-�4 11/16
Scale = NONE
BOXES MOUNT TO WALL
WITH APPROVED
—
FASTENING DEVICES
APPROVED BOX
DEVICE (TRIM, PLASTER, MUD)
SEPARATION (NEXT BOXES MOUNT TO WALL
DEVICE (TRIM, PLASTER, MUD)
WALL BOARD RINGS SHALL APPROXIMATE
\
RINGS SHALL APPROXIMATE
MINIMUM
THE DEPTH OF THE WALL
THE DEPTH OF THE WALL
16 in.
` —
BOARD OR BE SLIGHTLY (1/16 ")
SEPARATION
SHORTER TO PROVIDE
BLOCK WALL
6 irt: -...
PROPER FACEPLATE
MOUNTING
PROPER FACEPLATE
0000 01901
FIRRING
O°
STRIPS
CHANNEL WALL FOR
TYPICAL DEMIZING/
BOX INSTALLATION
WALL BOARD —
CORRIDOR WALL
STUD SEPARATES TELECOM AND
WALL (FLUSH
BOX MOUNTING
TYPICAL STUD
SEE ELECTRICAL
0.
SPECIFICATIONS FOR
MINIMUM
APPROVED BOX
DEVICE (TRIM, PLASTER, MUD)
SEPARATION (NEXT BOXES MOUNT TO WALL
MOUNTING
WALL BOARD RINGS SHALL APPROXIMATE
BLOCK)
WITH APPROVED
HARDWARE
THE DEPTH OF THE WALL
BLOCK WALL —, FASTENING DEVICES
16 in.
r
BOARD OR BE SLIGHTLY (1/16 ")
\►
SHORTER TO PROVIDE
,
.r� x=
PROPER FACEPLATE
0000 01901
O°
MOUNTING
DEVICE (TRIM, PLASTER, MUD) RINGS
TYPICAL 8" BLOCK
SHALL APPROXIMATE THE DEPTH OF
\
STUD SEPARATES TELECOM AND
WALL (FLUSH
THE BLOCK SIDE OR BE SLIGHTLY (1/
TYPICAL STUD
ELECTRICAL DEVICE BOXESOR A
MOUNTED)
16") SHORTER TO PROVIDE PROPER
WALL BOX
MINIMUM OF 4" SEPARATION BETWEEN
. - 63011
FACEPLATE MOUNTING
MOUNTING
STUDS
OUTLET BOX MOUNTING
Scale = NONE
_ 2"
i
i
i
t
I
! A R E L
CITY CET E R _?
pEDCOR DESIGN GROUP
it
TECKuk-It
0 Y Lirk` �
r LI L
9105 E=st 56th S6: _.
SUiIr2i50
iND1ANAP0 ;S,IN462!6
317,524.63M
317.524 63_9 FAX
P E D C O R
DEVELOPMENT CO.
06;,- ; 28
SECURITY
ROUGH -IN
ow_ T 71
0.
w`
,
.r� x=
. - 63011
,.
Fr
4
NF
w
06;,- ; 28
SECURITY
ROUGH -IN
ow_ T 71