HomeMy WebLinkAbout0815.93.35f
\A A2 .(A3 A4 `.A5 / A6
AA
i
1
I
� I i
i
r_
_ I
1
I
AS — — -- —
j
I
(AC 1-- — — — — — — —
J I
I
AO — — —' — —
!
i
_ — — — — — —
1
AG — — — — —
AH '—
AJ `.
i
FT- - - - - --
%B -- - - -
II
II
< I!I
I
,I
I I
UPPER LEVEL PLAN_
M�
(C7j
X CE
ce
NORTH
cia
C12
C13
C14 f
nu
C15
CB;
f
A
GENERAL NOTES
1. VERIFY EXISTING GOND17IONS AND DIMENSIONS PRIOR TO WORK
INVOLVING REMODELING OR EXISTING CONDIMNS.
2, COORDINATE WORK OF THIS TRADE WITH OTHER TRADES.
3. DOOR NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE
THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN
ADDED (At00043). SEE SHEET SERIES A500 FOR DOOR AND
FRAME INFORMATION.
4, CAULK JUNCTURES BETWEEN DIFFERENT MATERIAL AS
OUTLINED IN PROJECT MANUAL.
5. ALL CONCRETE MASONRY UNITS SHALL BE LAID RUNNING BOND
UNLESS NOTED OTHERWISE.
6. PROVIDE PRECAST CONCRETE OR STEEL LINTELS OVER ALL
MASONRY OPENINGS. SEE STRUCTURAL DRAWINGS FOR ADDITION INFORMATION.
7. COORDINATE LOCATIONS OF OPENINGS IN CONCRETE MASONRY
WALLS WITH MECHANICAL AND ELECTRICAL CONTRACTOR.
8. ALL DIMENSIONS ARE SHOWN ON DRAWINGS. ANY DIMENSIONS NOT
SHOWN OR DEEMED OUESTIONABLE ARE TO BE VERIFIED WITH THE
ARCHITECT. DO NOT SCALE DIMENSIONS FROM DRAWINGS.
9, PROVIDE E•W. METAL STRAPPING AT ALL SURFACE MOUNTED ITEMS
MOUNTED TO FACE OF GYPSUM WALLBOARD WALLS.
10. ALL OUTSIDE CORNERS SHALL BE BULLNOSED UNLESS NOTED OTHERWISE.
11. FOR HEIGHTS OF WALLS AND PARTITIONS, SEE REFLECTED CEILING PLANS.
12. FOR TOILET ACCESSORIES, SEE DIVISION 700 DRAWINGS.
13. ALL CONCRETE MASONRY UNITS ABOVE GRADE SHALL BE LIGHT WEIGHT.
USE FIRE RATED UNITS WHERE APPLICABLE,
14, CAULK JUNCTURES BETWEEN DIFFERENT MATERIALS (I.E. PLASTER AND MASONRY).
15. CAULK ALL COUNTERTOP BACKSPLASHES TO WALL USING SILICONE
SEALANT IN COLOR AS SELECTED BY ARCHITECT.
16. PROVIDE MISCELLANEOUS METAL SUPPORTS FOR ALL CEILING SUPPORTED ITEMS.
17, FOR CASEWORK AND MILLWORK, SEE DIVISION 600 DRAWINGS.
'I
!I
�I
il
UPPER LEVEL KEY PLAN
NORTH
0
CSO
ARCHITECTS
INCORPORATED
ARCHITECTS
PLANNERS
INTERIOR DESIGNERS
o COPYRIGHT 1991
9100 KEYSTONE CROSSING
INDIANAPOLIS, INDIANA 46240
(317) 848 -7800
SCOPE DRAWINGS
'7iea 9s q e
e p J^
c. d
s weEe
�sys[Ems.
G` c ce ee ec_�ce.,e:ce;e
fiE a.ew�,Ssc a or
sc•16e DI'. wo.k req�irad fD � per!o^^a�ce
Metre
d ?c�Vas o cesce -Dec �^ce'�^
I& . - c a °� proper
a
0
m
crY
O
Q
W
H-
Z
M
O1
f; M
Z co
f Q
1�
T
Q
Q
z m
00
^- v
= m
f^ Q
uj
W Z
Q
� 0
� Z
H
� J
W
f
V) U
Q
w
Ln
In
z
Q
W
=
�
U
W
LLJ
LL-
.J
ry
3
W
z
L-i d
Q-
>
� cf)
0 z
z U
Oro
r 000*34 i�li = -
t TAT? OF
r
CERTIFIED BY
SHEET NO
A103
OF SHEETS
FILE NO
92217