HomeMy WebLinkAbout0815.93.105MECHANICAL ABBREVIATIONS
AC
AIR CONDITIONING
ACP
ACCESS PANEL
ACU
AIR CONDITIONING UNIT
AD
AREA DRAIN
AFF
ABOVE FINISHED FLOOR
AFMS
AIR FLOW MEASURING STATION
AHU
AIR HANDLING UNIT
AMB
AMBIENT
AP
ACID PROOF
ARCH
ARCHITECTURAL)
ARV
AIR RELIEF VALVE
AUTO
AUTOMATIC
BD
BDD
BHP
BLDG
BT
B TM
BAROMETRIC DAMPER
BACKDRAFT DAMPER
BREAK HORSE POWER
BUILDING
BATH TUB
BOTTOM
C
CARBON DIOXIDE
CA
COMPRESSED AIR
CB
CATCH BASIN
CAB
CABINET
CHWR
CHILLED WATER RETURN
CHWS
CHILLED WATER SUPPLY
CHWP
CHILLED WATER PUMP
Cl
CAST IRON
CLG
CEILING
CMP
CORRUGATED METAL PIPE
CO
CLEAN OUT
COL
COLUMN
COMP
COMPRESSOR
CONC
CONCRETE
COND
CONDENSER
CONSTR
CONSTRUCTION
CONTR"
CONTRACTOR
CONV
CONVECTOR
CPD
CONDENSATE PUMP DISCHARGE
CW
COLD WATER (DOMESTIC)
CWP
CONDENSER WATER PUMP
CWR
CONDENSER WATER RETURN
CWS
CONDENSER WATER SUPPLY
DB
DRY BULB TEMPERATURE
DF
DRINKING FOUNTAIN
DIF
DIFFUSER
DISCH
DISCHARGE
DS
DOWNSPOUT
DW
DISTILLED WATER
DWC
DRINKING WATER COOLER
DWG
DRAWING
DWV
DRAINAGE WASTE, & VENT
DUC
DOOR UNDER CUT
EC
ELECTRICAL CONTRACTOR
EF
EXHAUST FAN
EFF
EFFICIENCY
ELEC
ELECTRIC
ELEV
ELEVATION
EMER
EMERGENCY
EP
ELECTRIC /PNEUMATIC
EQUIP
- EQUIPMENT
EXH
EXHAUST
EXP
EXPANSION
EXT
EXTERIOR
EMD
END OF MAIN DRIP
F &T
FLOAT AND THERMOSTATIC
FCU
FAN COIL UNIT
FCO
FLOOR CLEANOUT
F /SD
COMBINATION FIRE /SMOKE DAMPER
FD -1
FLOOR DRAIN TYPE
FD
FIRE DAMPER
FL
FLOOR
FOV
FUEL OILVENT
FP
FIRE PROTECTION
FPM
FEET PER MINUTE
FURN
FURNACE
G GAS (NATURAL)
GA GAUGE
GAL GALLON
GC GENERAL CONTRACTOR
HB
HOSE BIB
HGT
HEIGHT
HHR
HEATING HOT WATER RETURN
HHS
HEATING HOT WATER SUPPLY
HHWP
HEATING; HOT WATER PUMP
HP.
HORSE POWER
HPR
HIGH PRESSURE STEAM RETURN
HIPS
HIGH PRESSURE STEAM SUPPLY
HTR
HEATER
HW
HOT WATER (DOMESTIC)
HWR
HOT WATER RETURN (DOMESTIC)
INCIN
INCINERATOR
INT
INTERIOR
INV
INVERT
KEC KITCHEN
KW KILOWATT
LAB LABORATORY
LAV LAVATORY
LP LIQUID PETROLEUM
LPR LOW PRESSURE STEAM
LPS LOW PRESSURE STEAM
MA
MEDICAL COMPRESSED AIR
MB
MOP BASIN
MC
MECHANICAL CONTRACTOR
MECH
MECHANICAL
MH
MANHOLE
MPR
MEDIUM PRESSURE STEAM RETURN
MPS
MEDIUM PRESSURE STEAM
MTD
MOUNTED
N
NITROGEN
NIC
NOT IN CONTRACT
NO
NITROUS OXIDE
NPW
NON- POTABLE WATER
NTS
NOT TO SCALE
0
OXYGEN
OA
OUTSIDE AIR
OFCI
OWNER FURNISHED /CONTRACTOR INSTALLED
OFOI
OWNER FURNISHED /OWNER INSTALLED
OPNG
OPENING
OR
OIL RETURN
OS
OIL SUPPLY
PE PNEUMATIC /ELECTRIC
PIV POST INDICATOR VALVE
PRV PRESSURE REDUCING VALVE
PVC POLY VINYL CHLORIDE
RA RETURN AIR
RACU ROOM AIR CONDITIONING UNIT
RAID RADIATION
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
RDL ROOF DRAIN LEADER
REG REGISTER
RH RODDING HOLE
RHG REFRIGERANT HOT GAS
RHW RECIRCULATED HOT WATER (DOMESTIC)
RL REFRIGERANT LIQUID
RM ROOM
RS REFRIGERANT SUCTION
SA SUPPLY AIR
SAN SANITARY
SCW SOFT COLD WATER
SD SMOKE DAMPER
SHT SHEET
SK SINK
SP STATIC PRESSURE
SPEC SPECIFICATIONS
SS SERVICE SINK
STD STANDARD
STM STORM
SU SHOWER UNIT
TCC TEMPERATURE CONTROL CONTRACTOR
TD TEMPERATURE DIFFERENCE
TEMP TEMPERATURE
THWR TEMPERED HOT WATER RETURN (DOMESTIC)
TW TEMPERED HOT WATER (DOMESTIC)
TXV THERMAL EXPANSION VALVE
UH
UNIT HEATER
U
URINAL
UV
UNIT VENTILATOR
V
VENT
VA
VALVE
VAC
VACUUM
VB
VACUUM BREAKER
VEL
VELOCITY
VD
VOLUME DAMPER
VT
VITRIFIED TILE
VTR
VENT THRU ROOF
W/
WI TH
WACO
ELECTRIC WATER COOLER
WB
WET BULB TEMPERATURE
WC
WATER CLOSET
WCO
WALL CLEAN OUT
WH
WALL HYDRANT
W/0
WITHOUT
1
R:
O1 INDICATES DIFFUSER, GRILL,
OR REGISTER NUMBER
2U INDICATES AIR QUAN. IN CFM
3O TURNING VANES
4O AIR FLOW MEASURING STATION
05 SOUND ABSORBER,
6) R (RISE)
O7 D (DROP)
8U MOTORIZED DAMPER
9O DUCT SIZE SHOWN INSIDE RECTANGLE INDICATES
CLEAR INSIDE DIMENSION FOR DUCT THAT IS
INTERNALLY LINED WITH INSULATION
MECHANICAL SYMBOLS
10 FLEXIBLE CONNECTION
11 BACKDRAFT DAMPER
12 SPIN —IN CONNECTION
13 TERMINAL BOX
14 FLAT OVAL DUCT SIZE
15 RECTANGULAR DUCT SIZE
16 ROUND FLEX DUCT SAME SIZE AS DIFF. INLET
PIPE TURNED UP 'l ECCENTRIC REDUCER
PIPE TURNED DOWN
G FLOW CONTROL VALVE
PIPE OUT TOP
PIPE OUT BOTTOM THERMOMETER
CHECK VALVE
> INDICATES DIRECTION OF DOWNWARD PITCH
L_F_ INDICATES EXPANSION LOOP PRESSURE GAUGE
MIS GAS SHUT -OFF COCK
PIPE ANCHOR
SOLENOID VALVE
PIPE EXPANSION JOINT
\ —/ PIPE ALIGNMENT GUIDE 2 —WAY TEMPERATURE
—� CONTROL VALVE
SPRINKLER HEAD UPRIGHT TYPE
3 —WAY TEMPERATURE
(O SPRINKLER HEAD PENDANT TYPE CONTROL VALVE
WATER PRESSURE REDUCING/
7
\/ SPRINKLER HEAD SIDEWALL TYPE REGULATING VALVE
WATER PRESSURE
RELIEF VALVE
GATE VALVE
AIR RELIEF VENT
BALL VALVE
BUTTERFLY VALVE
UNION T THERMOSTAT
�_— STRAINER H HUMIDISTAT
FLEXIBLE CONNECTION LUBRICATED PLUG VALVE
ROUND SPIRAL DUCT SAME SIZE AS
DIFFUSER INLET
SLOT TYPE DIFFUSER -WITH DIRECTION
OF AIR DISCHARGE
q9� 45 -90 DEG TEE
20 ROUND SPIRAL DUCT SIZE
21 FLEXIBLE DUCT SAME SIZE AS
TERMINAL BOX INLET
22 INDICATES TERMINAL BOX NUMBER
23 90 DEG. CONICAL TEE
24 PADDLE TYPE EXTRACTOR
25 OPPOSED BLADE VOLUME DAMPER
26 AIR VALVE
DOMESTIC HOT WATER
TEMPERATURE REGULATING VALVE
CALIBRATED BALANCING VALVE
STEAM PRESSURE
REDUCING VALVE
SAFETY PRESSURE
R RELIEF VALVE
T STEAM TRAP
CONNECT NEW TO EXISTING,VERIFY
SIZE AND LOCATION OF EXISTING
ON SITE
T PILOT THERMOSTAT
T THERMOSTAT
(DA ASPERATING THERMOSTAT
T G THERMOSTAT WITH GUARD
>t< CHAIN OPERATED VALVE
DOUBLE CHECK VALVE ASSEMBLY
REDUCED PRESSURE BACKFLOW
PREVENTER
ATMOSPHERIC VACUUM BREAKER
PRESSURE VACUUM BREAKER
INSTITUTIONAL TAMPER PROOF
• SPRINKLER HEAD
GAS PRESSURE REDUCING/
REGULATING VALVE
NOTE: ALL SYMBOLS MAY NOT BE USED
ON THIS PROJECT
5
CSO
ARCHITECTS
INCORPORATED
ARCHITECTS
PLANNERS
INTERIOR DESIGNERS
O COPYRIGHT 1991
9100 KEYSTONE CROSSIIG
INDIANAPOUS, INDIANA 46240
(317) 848 -7800
SCOPE DRAw1NGS
n,... �.- .,..«. ew goo ..... of
oEwo�gl tM dYnw.to�. a Hw
ad�.clvd NnwK oM M N
.tn'ctvdln.d�a.ed
r" j* NI r tn4eeM a
do/D..�aM1 nOJed br Ri 0
..
end me'.wwwwts a tae
Cwbro L on M eed. a w. d seao.
tMoet.d a d.sorl.4 tM trod. awtroctas
.Td *.,A h d Rwn �.ouYed ler tA. MM
a.ovtlon and aoepMtlw a Pe ea&
cri
z
0
V)
w
M
rn
�
m
m
i
00
� i
z
a
o
Y Q
W a
Q Do
0 0
ct
0
Z
� a
w Z
w
a
I— p
N z
U
Q
� J
w
M
Z
v) U
W
Gf)
In
z
O
_
U
Q
�
U
L.LI
W
li
m
J
Q
Z
W_ Q
>
o�
F--
V)
0 2
Z U
O
m
1, .1R
O
-v N4
P�0910310 s
Mill as
CERTIFIED BY
SHEET NO
M501
OF SHEETS
FILE NO
92217