HomeMy WebLinkAbout0815.93.106AIR HANDLING UNIT SCHEDULE MARK UNIT RATING IN W.C. TOTAL OUTSIDE MINIMUM FAN MOTOR E.W.T. =447 L w T =59'17 COOLING COIL (25% GLYCOL) E.W.T. =180'17 HEATING COIL L. W. T. =150'17 SYSTEM RELIEF MARK AREA SERVED LOCATION AIR VOLUME AIR VOLUME OUTSIDE AIR FILTERS REMARKS D • (IN) ESP WHEEL FAN OUTLET VALVE WATER 4" MARK H.P. SERVICE INPUT OUTPUT TOT. SENS SO. FT. ENTERING AIR LEAVING AIR ROWS DEEP FINS PER /FT AREA WATER PRESS. MBH GPM ENT. AIR LEAV. AIR ROWS DEEP FINS PER /FT. FACE AREA WATER PRESS. DB /WB ('F) DB /WB ('F) 32.2 (PSIG) LOREN COOK SERIES ACE -B, #18OC78 WITH. BACKDRAFT DAMPER ROOF CURB, DISCONNECT SWITCH (CFM) (CFM) PERCENT 7(INWG) IN WG) D IA. RPM LOCITY TYPE CLASS HP BHP RPM VOLTS PHASE CYCLE MBH MBH GPM (MIN.) (MAX.) (S'F') LOSS 150 180 TEMP. (F) TEMP. (F) (MIN.) (MAX.) (S.F.) LOSS - UPBLAST 12 PSIG LIKE BELL & GOSSETT 74,300 5.1 .32 UUNIT H MODEL 240 LOREN COOK #180VH88 WITH ROOF CURB, NEMA 3R DISCONNECT EF -2 UNIT "C" ROOF /KITCHEN HOOD AT HOOD 2500 2.0" GREASE DUTY 1555 BELT 18" 1 1/2 208 3 60 SWITCH, GREASE TERMINATOR, UL 762 GREASE RATING EF -3 CHOIR MEZZ. /CHOIR RESTROOMS 8 102 43.6 12.2' 1443 96 50' 105' 2 103 43.6 3.9' 30% PLEAT, LIKE TRANE HORIZ. BLOWTHRU CLIMATE CHANGER, MODEL 50 W/ MEDIUM CAPACITY COMBINATION FILTER /MIXING BOX, DIFFUSER SECT., DISCHARGE PLENUM, CONSTANT VOLUME, 24" ACCESS BETWEEN COILS AHU -1 SANCTUARY MECH. ROOM 24,200 5500 23% 3.8 1.5 30" 645 - FC 1 25 23.3 1750 208 3 60 1032 750 153 82'/67.5' 53.9'/53.7' 60 LOREN COOK SERIES SWD, #20S10D WITH WALL COLLAR, OSHA FAN GUARD, WALL SHUTTER ROOM TRANE CABINET UNIT HEATER MODEL "H ", BY DIV. 15 200 1100 1/15 115 1/60 15,300 1.0 .24 ARRANGEMENT H46, UNIT SIZE "02 ", VERT., 4" RECESS DRAFT MECH. RM. /WATER HEATER WTR. HTR. 190 0'06 " DRAFT INDUCER - DIRECT - 74W 120 1 60 TJERNLUND #D -3 WITH FAN PROVING SWITCH ::1 FAN-. LIKE B&G SERIES 1510 MODEL 2 1/288 CTRL. PANEL I LIKE TRANE HORIZ. BLOWTHRU CLIMATE CHANGER, MODEL 25 AHU -2 NARTHEX MECH. ROOM 12,400 1725 15% 3.0 1.40 25" 704 - FC 1 10 9.7 1750 208 3 60 424 346 63 80'/65.5' 54.7'/54.2' 6 116 24.4 12.2' 646 43 57' 105' 2 100 24.4 1.1' 309; PLEAT. W/ MEDIUM CAPACITY COMBINATION FILTER /MIXING BOX, DIFFUSER SECT., DISCHARGE PLENUM, CONSTANT VOLUME, 24" ACCESS BETWEEN COILS LIKE TRANE HORIZ. BLOWTHRU CLIMATE CHANGER, MODEL 17 8.4' - - _ _ _ _ _ 30% MEDIUM CAPACITY COMBINATION FILTER /MIXING BOX, DIFFUSER SECT., AHU -3 R LOWER LEVEL MECH. ROOM 7500 1300 17% 3.65 2.35 �, 18 1043 - FC 1 7.5 6.8 1750 208 3 60 257 210 38 80'/65.5' 54.6'/54.2' 6 11 0 16.8 - PLEAT. DISCHARGE PLENUM, VAV W/ INVERTER, INVERTER DUTY MOTOR DI CLASSROOMS LIKE TRANE HORIZ. BLOWTHRU CLIMATE CHANGER, MODEL 21 30% MEDIUM CAPACITY COMBINATION FILTER /MIXING BOX, DIFFUSER SECT., AHU -4 ADMINISTRATION MECH. ROOM 9,000 1200 13% 4.90 3.75 20" 1150 - FC 1 15 12 1750 208 3 60 329 270 49 81'/65' 53.7'/53.3' 6 117 20.8 9.4' - - - - _ _ _ _ PLEAT. DISCHARGE PLENUM, VAV W/ INVERTER, INVERTER -DUTY MOTOR DI LIKE TRANE HORIZ. BLOWTHRU CLIMATE CHANGER, MODEL 25 - - 309, MEDIUM CAPACITY COMBINATION FILTER /MIXING BOX, DIFFUSER SECT., AHU -5 MAIN &UPPER MECH. ROOM 11,200 1680 15% 4.30 2.90 22" 923 - FC 1 15 11.5 1750 208 3 60 403 334 60 83'/66' 55'/54' 6 117 .24.4 11.1' - - - - - - PLEAT. DISCHARGE PLENUM, VAV W/ INVERTER, INVERTER -DUTY MOTOR DI CLASSROOMS LIKE TRANE HORIZ. BLOWTHRU CLIMATE CHANGER, MODEL 6 AHU -6 CHOIR CHOIR MEZZ. 2500 600 24% 1.9 .75 12" 1143 - FC 1 1.5 1.2 1750 208 3 60 100 77 15 82'/67' 54,2'/54' 6 146 5.86 2.3' 149 10 50' 105' 2 120 5.86 .33' 30% PLEAT. W/ MEDIUM CAPACITY COMBINATION FILTER /MIXING 80X, DIFFUSER SECT., DISCHARGE PLENUM, CONSTANT VOLUME, 24' ACCESS BETWEEN COILS LIKE TRANE HORIZ. BLOWTHRU CLIMATE CHANGER, MODEL 6 AHU -7 CHAPEL MECH. ROOM 3000 750 25% 3.15 1.30 10" 1805 - FC 1 3 2.7 1750 208 3 60 119 92 18 82'/67' 54.3'/54.1' 8 109 5.86 3.9' 178 12 50' 105' 2 136 5.86 .45' 307- PLEAT. W/ MEDIUM CAPACITY COMBINATION FILTER /MIXING BOX, DIFFUSER SECT., DISCHARGE PLENUM, CONSTANT VOLUME, 24' ACCESS BETWEEN COILS ALT. BID FAN SCHEDULE MARK UNIT RATING IN W.C. CFM MAXIMUM COOLING (45' E.W.T, 10' o T) CONNECTION SYSTEM WHEEL MOTOR SYSTEM RELIEF MARK LOCATION / SERVICE FAN CONTROL CFM ESP (IN WG) TYPE FAN MOTOR D • (IN) HEAT SURFACE REMARKS L.W.T. WATER CAPACITY VALVE WATER 4" MARK H.P. SERVICE INPUT OUTPUT H.P. GPM SO. FT. HP VOLTS PHASE CYCLES (FFT. T. ) REMARKS 6.5 TRANE HORIZONTAL CABINET MODEL #D11 WITH VALVE PACKAGE #335 FC -2 1200 25' - HI 1/6 HP 8(? 0 32.2 (PSIG) LOREN COOK SERIES ACE -B, #18OC78 WITH. BACKDRAFT DAMPER ROOF CURB, DISCONNECT SWITCH EF -1 UNIT "C" ROOF /RESTROOMS DOC 2900 1.0" ROOF 1150 BELT 18" 1 208 3 60 115 LIKE BRYAN MODEL CL -180 FLEXIBLE WATER TUBE PANEL 43 208V/60/10 CENTRIF. 1440 3/4 96 215 150 180 45 , 1.0 BOILER, NATURAL GAS, FORCED DRAFT, UL /FM GAS SWITCH 1 -1/2" - UPBLAST 12 PSIG LIKE BELL & GOSSETT 74,300 5.1 .32 UUNIT H MODEL 240 LOREN COOK #180VH88 WITH ROOF CURB, NEMA 3R DISCONNECT EF -2 UNIT "C" ROOF /KITCHEN HOOD AT HOOD 2500 2.0" GREASE DUTY 1555 BELT 18" 1 1/2 208 3 60 SWITCH, GREASE TERMINATOR, UL 762 GREASE RATING EF -3 CHOIR MEZZ. /CHOIR RESTROOMS DDC 600 .75 " IN -LINE 1140 DIRECT 14 1/4 115 1 60 LOREN COOK SERIES CVD, # 14CVD 1 1 D WITH BACKDRAFT DAMPER AND SPEED CONTROLLER 1.0 BOILER, NATURAL GAS, FORCED DRAFT, UL /FM GAS PANEL CENTRIF. TRANE CABINET UNIT HEATER MODEL "E ", CUH -2 400 1100 1/8 EF -4 ELEVATOR EQUIP. ROOM /SAME TSTAT 1000 0.50" SIDEWALL PROPELLER 950 DIRECT 20" 1/3 120 1 60 LOREN COOK SERIES SWD, #20S10D WITH WALL COLLAR, OSHA FAN GUARD, WALL SHUTTER ROOM TRANE CABINET UNIT HEATER MODEL "H ", BY DIV. 15 200 1100 1/15 115 1/60 15,300 1.0 .24 ARRANGEMENT H46, UNIT SIZE "02 ", VERT., 4" RECESS DRAFT MECH. RM. /WATER HEATER WTR. HTR. 190 0'06 " DRAFT INDUCER - DIRECT - 74W 120 1 60 TJERNLUND #D -3 WITH FAN PROVING SWITCH ::1 FAN-. LIKE B&G SERIES 1510 MODEL 2 1/288 CTRL. PANEL I 1 EF -5 ELECTRICAL ROOM /SAME TSTAT 1000 0,50 SIDEWALL PROPELLER 950 DIRECT 20" 1/3 120 1 60 LOREN COOK SERIES SWD, #20S10D WITH WALL COLLAR, OSHA FAN GUARD, WALL SHUTTER 1/60 BY DIV 16 BY DIV. 15 1 -1/2 MECH. LIKE B&G SERIES 60 #6016- 1 -1 /2A GLYCOL MAKEUP ROOM BOILER SCHEDUI F MARK UNIT RATING IN W.C. CFM MAXIMUM COOLING (45' E.W.T, 10' o T) CONNECTION SYSTEM LOCATION MARK SYSTEM RELIEF SIZE CAPACITY TYPE BOILER ELECTRICAL MBH MBH MOTOR CIRCUIT HEAT SURFACE E.W.T. L.W.T. WATER CAPACITY VALVE WATER 4" MARK H.P. SERVICE INPUT OUTPUT H.P. GPM SO. FT. ('F) (•F) (GALLONS) SETTING (FFT. T. ) REMARKS 6.5 TRANE HORIZONTAL CABINET MODEL #D11 WITH VALVE PACKAGE #335 FC -2 1200 25' - HI 1/6 HP 8(? 0 32.2 (PSIG) ET -1 CH. WTR. MECH. RM. 66 "x24" 105 VERTICAL W/ BLADDER 1" 1_1/2" - - 12 PSIG LIKE BELL & GOSSETT 1550 1/8 115 LIKE BRYAN MODEL CL -180 FLEXIBLE WATER TUBE BOILER #1 43 208V/60/10 1800 1440 3/4 96 215 150 180 45 30 1.0 BOILER, NATURAL GAS, FORCED DRAFT, UL /FM GAS 1" 1 -1/2" - - 12 PSIG LIKE BELL & GOSSETT 74,300 5.1 .32 UUNIT H MODEL 240 208V/60/30 422 TRAIN, 120V CONTROL TRANSFORMER (11) ® 1.5HP 30" (1) ® 85HP MODEL 6600 18 FT. TRANE CABINET UNIT HEATER MODEL "H ", CUH -1 400 1100 1/8 115 1/60 31,700 LIKE BRYAN MODEL CL -180 FLEXIBLE WATER TUBE BOILER #2 43 208V/60/10 1800 1440 3/4 96 215 150 180 45 30 1.0 BOILER, NATURAL GAS, FORCED DRAFT, UL /FM GAS TRANE CABINET UNIT HEATER MODEL "E ", CUH -2 400 1100 1/8 115 TRAIN, 120V CONTROL TRANSFORMER PRESSURIZED EXPANSION TANK SCHEDULE MARK UNIT RATING IN W.C. CFM MAXIMUM COOLING (45' E.W.T, 10' o T) CONNECTION SYSTEM LOCATION MARK SYSTEM LOCATION SIZE CAPACITY TYPE GPM PRE- CHARGE REMARKS RPM ELECTRICAL CIRCUIT NO. OF FANS FAN SERVED AS -1 (HGT.XDIA.) (GAL.) 4" PRESSURE LIKE BELL & rOSSETT ROLAIRTROL #R -4 AS -2 HEATING WATER MECH. RM. 3" 190 LIKE BELL & GOSSETT ROLAIRTROL #R -3 DRAIN SYSTEM VENT OTHER 23.5 6.6 6.5 TRANE HORIZONTAL CABINET MODEL #D11 WITH VALVE PACKAGE #335 FC -2 1200 25' - HI 1/6 HP 8(? 0 32.2 23.5 ET -1 CH. WTR. MECH. RM. 66 "x24" 105 VERTICAL W/ BLADDER 1" 1_1/2" - - 12 PSIG LIKE BELL & GOSSETT 1550 1/8 115 1 /60 46,000 3.8 .70 MODEL 96 65 - MODEL 8400 ET -2 HTG. WTR. MECH. RM. 65 "x30" 158 VERTICAL W/ BLADDER 1" 1 -1/2" - - 12 PSIG LIKE BELL & GOSSETT 74,300 5.1 .32 UUNIT H MODEL 240 208V/60/30 422 389 (11) ® 1.5HP 30" (1) ® 85HP MODEL 6600 AIR SEPARATOR SCHEDULE MARK UNIT RATING IN W.C. CFM MAXIMUM COOLING (45' E.W.T, 10' o T) MARK SYSTEM LOCATION SIZE (IN.) CAPACITY REMARKS (HI- SPEED) SERVED W80F GPM (GPM) AMPS WATTS RPM ELECTRICAL CIRCUIT NO. OF FANS FAN REMARKS AS -1 CHILLED WATER MECH. RM. 4" 300 LIKE BELL & rOSSETT ROLAIRTROL #R -4 AS -2 HEATING WATER MECH. RM. 3" 190 LIKE BELL & GOSSETT ROLAIRTROL #R -3 FAN COIL UNIT SCHEDULE MARK UNIT RATING IN W.C. CFM MOTOR DATA 115 -60 -1 COOLING (45' E.W.T, 10' o T) REMARKS EAT TOTAL COOL. MBH SENS. COOL. MBH CHILLED WATER SPEED (HI- SPEED) DB°F W80F GPM wPD AMPS WATTS RPM ELECTRICAL CIRCUIT NO. OF FANS FAN REMARKS CIRCUITS WATER PHASE MARK TONS TONS GPM FC -1 1200 - - HI - 165 800 67° 32.2 23.5 6.6 6.5 TRANE HORIZONTAL CABINET MODEL #D11 WITH VALVE PACKAGE #335 FC -2 1200 25' - HI 1/6 HP 8(? 0 32.2 23.5 6.6 6.5 TRANE HORIZONTAL RECESSED MODEL #E34, DUCTED RETURN DISCHARGE, VALVE PACKAGE #335, REMOTE THERMOSTAT, HI- STATIC MOTOR. HEATING HOT WATER UNIT CABINET HEATER SCHEDULE E.W.T. -180' UNIT/ CABINET E.A.T. -60' LWT = 45' F TYPE OF EQUIP. CONTROL HEATING COIL MOTOR MINIMUM MOTOR NO. OF REFRIGERANT FCAPACITY DES. MARK CFM RPM ELECTRICAL CIRCUIT NO. OF FANS FAN REMARKS CIRCUITS WATER PHASE MARK TONS TONS GPM GPM (FTA OF HEDD) & MOTOR H.P. SIZE & MOTOR H.P. HP VOLTS (GPM) (FT.) HEAD RPM HP VOLTS CYCLE CYCLE DROP DISH CIRC. CIRC. STAGING TRANE HORIZONTAL PROPELLER UNIT PUH -1 1535 1550 1/8 115 1 /60 46,000 3.8 .70 MODEL 96 65 - 1750 5 208 3/60 BY DIV 16 2 -1/2 TRANE HORIZONTAL PROPELLER PUH -2 2220 1070 1/6 115 1/60 74,300 5.1 .32 UUNIT H MODEL 240 208V/60/30 422 389 (11) ® 1.5HP 30" (1) ® 85HP 18 FT. TRANE CABINET UNIT HEATER MODEL "H ", CUH -1 400 1100 1/8 115 1/60 31,700 2.0 1.28 ARRANGEMENT H46, UNIT SIZE "04 ", VERT., 4" RECESS (1) ® 70HP (VARIABLE) MECH. LIKE B&G SERIES 1510 MODEL 2BC ROOM PROVIDE WALL RECESS TRIM FLANGE TRANE CABINET UNIT HEATER MODEL "E ", CUH -2 400 1100 1/8 115 1/60 31,700 2.0 1.28 UNIT SIZE "04 ", HORIZONTAL, FULLY RECESSED. ARRANGEMENT E46, 3/60 BY DIV 16 3 2 -1 /2 MECH. LIKE B&G SERIES 1510 MODEL 2 1/288 ROOM TRANE CABINET UNIT HEATER MODEL "H ", CUH -3 200 1100 1/15 115 1/60 15,300 1.0 .24 ARRANGEMENT H46, UNIT SIZE "02 ", VERT., 4" RECESS Cyyp -2 CHILLED WATER MECH. END SUCT. 120 75 - PROVIDE WALL RECESS TRIM FLANGE DESIGN DATA: AMBIENT TEMP.= 105'F D.B. P AC KA G E D AIR CHILLER SCHEDULE FOULING FACTOR =.00 25 COOLED EWT = 60' F LWT = 45' F TYPE OF EQUIP. CONTROL MAX. MOTOR MINIMUM PUMP NO. OF REFRIGERANT DES. NOMINAL ACTUAL ELECTRICAL CIRCUIT NO. OF FANS FAN NO. OF COMPR. CIRCUITS WATER CAP MARK TONS TONS GPM SERVICE AAPACITY & MOTOR H.P. SIZE & MOTOR H.P. PRESSURE REMARKS ' (GPM) (FT.) HEAD RPM HP VOLTS CYCLE START. DROP DISH CIRC. CIRC. STAGING NO. 1 NO. 2 MECH. END SUCT. 96 65 - 1750 5 208 3/60 BY DIV 16 2 -1/2 2 MECH. LIKE B&G SERIES 1510 MODEL 28C 2 CHILLER -1 155 149.2 240 208V/60/30 422 389 (11) ® 1.5HP 30" (1) ® 85HP 18 FT. T TRANE #RTAA -155, 25% ETH- GLYCOL 10% -100% END SUCT. 96 65 - 1750 5 208 3/60 BY DIV 16 (1) ® 70HP (VARIABLE) MECH. LIKE B&G SERIES 1510 MODEL 2BC PUMP SCHEDULE EQUIPMENT SCHEDULE SYSTEM SERVED LOCATION TYPE OF EQUIP. CONTROL MAX. MOTOR PUMP PUMP DES. DES. SHUT SIZE SEAL SEE SPECS & DETAIL 5 -M402 NO. SYSTEM LOCATION PUMP TYPE CAP HEAD OFF TYPE REMARKS (GPM) (FT.) HEAD RPM HP VOLTS CYCLE START. (IAN . DISH HWP -1 HEATING WATER MECH. END SUCT. 96 65 - 1750 5 208 3/60 BY DIV 16 2 -1/2 2 MECH. LIKE B&G SERIES 1510 MODEL 28C ROOM HWP -2 HEATING WATER MECH. END SUCT. 96 65 - 1750 5 208 3/60 BY DIV 16 2-1/2 2 MECH. LIKE B&G SERIES 1510 MODEL 2BC ROOM CWP -1 CHILLED WATER MECH. END SUCT. 120 75 - 1750 7.5 208 3/60 BY DIV 16 3 2 -1 /2 MECH. LIKE B&G SERIES 1510 MODEL 2 1/288 ROOM Cyyp -2 CHILLED WATER MECH. END SUCT. 120 75 - 1750 7.5 208 3/60 BY DIV 16 3 2 -1 /2 MECH. LIKE B&G SERIES 1510 MODEL 2 1/288 ROOM GLYP -1 CHILLED WATER MECH. IN -LINE t0 50 - 1770 3/4 120 1/60 BY DIV 16 1 -1/2 1 -1/2 MECH. LIKE B&G SERIES 60 #6016- 1 -1 /2A GLYCOL MAKEUP ROOM WATER TREATMENT EQUIPMENT SCHEDULE SYSTEM SERVED LOCATION TYPE OF EQUIP. CONTROL CHEMICAL TYPE REMARKS CHILLED WATER MECH. RM. SHOT FEEDER MANUAL LIQUID SEE SPECS & DETAIL 5 -M402 HEATING WATER MECH. RM. SHOT FEEDER MANUAL LIQUID SEE SPECS & DETAIL 5 -M402