Loading...
HomeMy WebLinkAbout0815.93.94L1 PLUMBING _SYMBOLS AND ABBREVIATION • A - COMPRESSED AIP� UR -1 URINAL TYPE ACT ACETYLENE "W - AD AREA DRAIN V VENT AFF ABOVE FINISHED FLOOR VA VALVE AFG ABOVE FINISHED GRADE VAC VACUUM (MEDICAL) ;,R ACID RESISTANT VB VACUUM BREAKER ARV AIR RELIEF VENT VS VENT STACK AP ACID PROOF VT VITRIFIED TILE 1" MEZZININE VTR VENT THRU ROOF BLDG BUILDING W/ WITH BT -1 BATH TUB TYPE WC WATER ,CLOSET BTM BOTTOM WCO WALL CLEANOUT _ MECH. ROOM 0003 WF -1 WASH FOUNTAIN TYPE CA COMPRESSED AIR W/0 WITHOUT CB CATCH BASIN WS WASTE STACK CFH CUBIC FEET PER HOUR WSSK -1 WALL SERVICE SINK TYPE CO2 CARBON DIOXIDE CA RB CONNECT NEW TO EXIST. CO CLEANOUT VERIFY SIZE AND LOCATION COL COLUMN OF EXIST. ON SITE CONTR CUSP -1 CONTRACTOR CUSPIDOR TYPE - COLD WATER (SOFTENED) PIPING - MECH. ROOM 0003 - - HOT WATER (110'F) PIPING D DEPTH /DEEP 1 DF -1 DRINKING FOUNTAIN TYPE - - -- 140' -HOT WATER (1407) PIPING DIA /,O DIAMETER -----HOT WATER RETURN DISCH DISCHARGE DISTILLED WATER - - - -- 140' -HOT WATER (140'F) RETURN DW DWG DRAWING FP FIRE PROTECTION DWV DRAINAGE WASTE AND VENT —FPTH —FIRE PROTECTION TEST HEADER PRV -1 ---- -V - - -- VENT PIPING ELEV ELEVATION EWC -1 ELECTRIC WATER COOLER TYPE UNDER FLOOR PIPING EXIST EXISTING GI -1 GREASE INTERCEPTOR SANITARY PIPING FD -1 FLOOR DRAIN TYPE ST STORM PIPING FH CAB FIRE HOSE CABINET - FL FLOOR FP FIRE PROTECTION PIPING FOR FUEL OIL RETURN _ FOS FUEL OIL SUPPLY G NATURAL GAS PIPING FOV FUEL OIL VENT GAS PRESSURE REGULATOR FPM FEET PER MINUTE A COMPRESSED AIR PIPING FS FLOW SWITCH FSSK -1 FLOOR SERVICE SINK TYPE FCO FLOOR CLEANOUT FCOO - -FLOOR CLEANOUT G NATURAL GAS COI- -- WALL CLEANOUT /ABOVE CEILING GC GENERAL CONTRACTOR H HEIGHT /HIGH DS • DOWNSPOUT ID INSIDE DIAMETER FD Q FLOOR DRAIN IE INVERT ELEVATION INV INVERT VTR --- -JI- -- VENT THRU ROOF L LENGTH /LONG ROOF DRAIN & OVERFLOW DRAIN L -1 LAVATORY TYPE RD OFD CB CATCH BASIN MAX MAXIMUM MFR MANUFACTURER S /MH —*-- SANITARY MANHOLE MH MANHOLE MIN MB -1 MINIMUM MOP BASIN TYPE ST /MH -STORM MANHOLE N2 NITROGEN SHUT -OFF VALVES NIC NOT IN CONTRACT N20 NITROUS OXIDE r„ iBV MEMORY BALANCE VALVE NTS NOT TO SCALE SOLENOID VALVE 02 OD OXYGEN OUTSIDE DIAMETER FLOW INDICATOR OFD OVERFLOW DRAIN OPNG OPENING 0 OXYGEN PIPING OSD OPEN SITE DRAIN CA COMPRESSED AIR PIPING PIV POST INDICATING VALVE N NITROGEN PIPING PT PERFORATED TILE —N20w NITROUS OXIDE PIPING PRV PRESSURE REDUCING VALVE PVC POLYVINYL CHLORIDE —ACT ACETYLENE PIPING pW PROCESS WATER PWR PROCESS WATER RETURN V �CHECK VALVE RCP REINFORCED CONCRETE PIPE PT PERFORATED TILE PIPING RD ROOF DRAIN RL REFRIGERANT LIQUID WM WATER MAIN PIPING RM ROOM RPBP -1 REDUCED PRESSURE BACKFLOW AW ACID WASTE PIPING PREVENTER TYPE AV ACID VENT SAN SANITARY STRAINER SH -1 SHOWER TYPE SHT SHEET V VACUUM PIPING SK -1 SINK TYPE SPEC(S) SPECIFICATIONS) STD STANDARD -- -r-iWH EXTERIOR WALL HYDRANT ST TCC STORM TEMPERATURE CONTROL CABINET —FHB HOSE BIBB TW TEMPERED WATER - 614t4:4 YALv� (TYp) E3ALL VALVIS (Wr-) 1114 11 �-� I200 r. ' 2M 1 1 • U- CALIBRATED BALANCING VALVE 0-- PIPE TURNED UP C PIPE TURNED DOWN --- ���- -- PIPE OUT TOP PIPE OUT BOTTOM DOUBLE CHECK VALVE ASSEMBLY REDUCED PRESSURE BACKFLOW PREVENTER ATMOSPHERIC VACUUM BREAKER PRESSURE VACUUM BREAKER R SAFETY PRESSURE RELIEF VALVE GAS PRESSURE REDUCING/ REGULATING VALVE THERMOMETER PRESSURE GAUGE GAS SHUT -OFF COCK LUBRICATED PLUG VALVE DOM, HW TEMP. REG. VALVE — �I-- -- ECCENTRIC REDUCER WATER PRESSURE REDUCING/ REGULATING VALVE WATER PRESSURE RELIEF VALVE ® COMPRESSED AIR REGULATOR OA COMPRESSED AIR OUTLET © NATURAL GAS OUTLET TYPICAL AT EACH CHANGE OF DIRECTION IN PIPING (CW,HW,HWR) MIN (2) 90 ELBOWS SIZE OF PIPE -8" ® .40%-% OF SLOPE APPROX LENGTH OF PIPE- 100' -.4'- APPROX HEIGHT OF SLOPE E- "E" PREFIX INDICATES EXISTING PIPE OR EQUIPMENT NOTE: ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT it m Iw- w-r-�t -w- I �ExT -I -T P 0-tLMP vALVS g M' SE C -S�W4. � E FM 604T. DIPLSe. -Mic IJ l 0 N S � _. IZoUTf✓ pI5GHAl2C�E PULL SIZ15 To FLOOR MAIM AMY' I (SAg rI sb TANK G TSK AouA-_-,*"[AT_ -- sEr'T :, PLUMBING EQUIPMENT SCHEDULE ` ELECTRICAL DATA MANUFACTURER MECHANICAL MODEL NUMBER CAPACITY REMARKS HP KW VOLTS 'Ta •s ?A iz"( @ tZo• P • ZURN ! '5-To f' @ IAd �• 11410140" . "W - 2- - Z " I moo• � H W �--�E— - - 3/4,a140 "r 14WV- � - - -- _ AQ LA5TAT - 5 WT • 0 S-T� -f @ Imo° �• -To p @ 120 ° r• 5Ti Iwt: -IZ( -Tyr) 614t4:4 YALv� (TYp) E3ALL VALVIS (Wr-) 1114 11 �-� I200 r. ' 2M 1 1 • U- CALIBRATED BALANCING VALVE 0-- PIPE TURNED UP C PIPE TURNED DOWN --- ���- -- PIPE OUT TOP PIPE OUT BOTTOM DOUBLE CHECK VALVE ASSEMBLY REDUCED PRESSURE BACKFLOW PREVENTER ATMOSPHERIC VACUUM BREAKER PRESSURE VACUUM BREAKER R SAFETY PRESSURE RELIEF VALVE GAS PRESSURE REDUCING/ REGULATING VALVE THERMOMETER PRESSURE GAUGE GAS SHUT -OFF COCK LUBRICATED PLUG VALVE DOM, HW TEMP. REG. VALVE — �I-- -- ECCENTRIC REDUCER WATER PRESSURE REDUCING/ REGULATING VALVE WATER PRESSURE RELIEF VALVE ® COMPRESSED AIR REGULATOR OA COMPRESSED AIR OUTLET © NATURAL GAS OUTLET TYPICAL AT EACH CHANGE OF DIRECTION IN PIPING (CW,HW,HWR) MIN (2) 90 ELBOWS SIZE OF PIPE -8" ® .40%-% OF SLOPE APPROX LENGTH OF PIPE- 100' -.4'- APPROX HEIGHT OF SLOPE E- "E" PREFIX INDICATES EXISTING PIPE OR EQUIPMENT NOTE: ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT it m Iw- w-r-�t -w- I �ExT -I -T P 0-tLMP vALVS g M' SE C -S�W4. � E FM 604T. DIPLSe. -Mic IJ l 0 N S � _. IZoUTf✓ pI5GHAl2C�E PULL SIZ15 To FLOOR MAIM AMY' I (SAg rI sb TANK G TSK NOTE: 10 REFER TO 'L' SERIES DRAWINGS FOR LOCATION. WATER HAMMER ARRESTER SCHEDULE MARK PLUMBING EQUIPMENT SCHEDULE ` ELECTRICAL DATA MANUFACTURER MECHANICAL MODEL NUMBER CAPACITY REMARKS HP KW VOLTS J.R. SMITH # ZURN ! I.P.S. F.U. RATING , ELECTRICAL REMARKS LOCATION MARK DESCRIPTION AMPS PHASE _ - - MECH. ROOM 0003 100 GAL. CAP.,182 GPH GLASS LINED TANK, POLYURETHANE INSULATION, LOCHINVAR CRN200- 100 -DF9 RECOVERY @ 1007 RISE HAND HOLE CLEANOUT, MAGNESIUM TANK SAVER, - - 120 COMMERCIAL 199,000 BTU /H RELIEF VALVE SHALL BE 125 PSIG MAX. 15 GPH RECOVERY ® 100' F GLASS LINED TANK. POLYURETHANE INSULATION. _ 4.5 208 LOCKINVAR RJJ012K RISE, 4500 WATT ELEMENT RELIEF VALVE SHALL BE 125 PSIG MAX. POWERS NO. 432 36 GPM ® 30 PSI PROVIDE VALVE, STRAINER AND UNION ON INLET; AND - HYDROGUARD MASTER PRESS. DIFF. UNION, CHECK AND SHUTOFF VALVE ON OUTLET, AND - - MIXING VALVE 657-1157 TEMP, ADJ. RANGE THERMOMETERS ON INLET AND OUTLET ON HOT WATER LINES TANK SHALL BE ASME CONSTRUQTED FOR 125 PSIG TANK VOL. 4.7 GAL. - - - AMTROL NO. AST12 WORKING PRESSURE. ENSURE RELIEF VALVE SETTING ACCEPT VOL. 2.4 ON WATER HEATER DOES NOT EXCEED 125 PSIG MIN. EXCHANGE 80,000 GR SOFTENER CONTROLS SHALL BRUNER MODEL MAX. EXCHANGE 120,000 GR INCLUDE AUTOMATIC, WATER METER - - 120 120 BA -2 CONT. FLOW - 42 GPM AND TIME CLOCK CONTROLS PEAK FLOW - 70 GPM WATTS SERIES. 909 -S -U 110 GPM ® PROVIDE WITH AIR (TWO IN PARALLEL) 12 PSI P.D. EACH GAP FITTING 909 -AG -F - - - (2" EACH) (75% OF TOTAL CAP) (TWO) DOM. WATER WATTS SERIES 909 -S -U 10 GPM ® PROVIDE WITH AIR GAP (SINGLE - 1 ")' FITTING 909 -AG -C 12 PSI P.D. MECH. SYST. WATER WATTS SERIES 709 DCDA AS REQUIRED BY SAME SIZE AS (SINGLE) HYDRAULIC CALCULATIONS SERVICE LINE FIRE PROTECTION 7 GPM ® 8' HD, 3 SPEED; SET ON 1/25 - 115 GRUNDFOS UPS15 -42F AQUASTAT CONTROLLED SPEED 2, 1350 RPM 3.75 GPM ® 4' HD, 3 SPEED; SET ON 1/25 - 115 GRUNDFOS UPS15 -42F AQUASTAT CONTROLLED SPEED 1, 950 RPM PROVIDE W/ STRAINER AND 2 GAUGES; ONE UPSTREAM WATTS NO. N223B -S (2 -1/2 ") 145 GPM ® 10 PSI AND ONE DOWNSTREAM OF PRV, AND A BALANCED - FALL OFF PRESSURE COCK BYPASS. ADJUSTABLE REDUCED PRESSURE RANGE, 25 TO 75 POUNDS. FLOW PRESS. TO BE SET SET AT REQUIRED PRESSURE PER DISHWASHER _ WATTS N0. U56LP BY DISHWASHER SUPPLIER MANUFACTURER RECOMMENDATIONS J.R. SMITH 50 GPM 100 LBS. PROVIDE WITH INTEGRAL EXTENSION, ANCHOR FLANGE, - ' F GREASE CAP FLOW CONTROL, RECESSED COVER FOR VINYL TILE, FIG. N0. 8250 -B - SEDIMENT BUCKET, AND 4" INLET AND OUTLET REDUCE GAS 3/4" PIPE SIZE, SPRING RANGE 6 TO 14 INCHES, - _ _ EQUIMETER PRESSURE FROM 2 PSI 1/4" ORIFICE, DO NOT HEADER VENT 043 -182 DOWN TO 7 TO 14 INCHES / EQUIMETER REDUCE GAS 1 -1/4" PIPE SIZE, SPRING RANGE 6 TO 14 INCHES, _ _ _ PRESSURE FROM 2 PSI 5/16" ORIFICE, DO NOT HEADER VENT 143 -80 -2 DOWN TO 5 TO 9 INCHES REDUCE GAS 2" PIPE SIZE, SPRING RANGE 6 TO 14 INCHES, _ _ _ EQUIMETER PRESSURE FROM 2 PSI 1" - 30' ORIFICE, DO NOT HEADER VENT 243 -12 -2 DOWN TO 7 TO 14 INCHES 1 -11 P.D.I. CERTIFIED DWH -1 DOMESTIC WATER HEATER - GAS - 1 1" MEZZININE DWH -2 DOMESTIC WATER HEATER - ELECTRIC W -20 5020 TMV -1 THERMOSTATIC MIXING VALVE MECH. ROOM 0003 - - _ MECH. ROOM 0003 EXT -1 DOMESTIC HOT WATER EXPANSION TANK - 1 PROVIDE ALL REQUIRED WIRING BETWEEN SOFTENER AND CONTROLLER. PROVIDE 120V ELECTRICAL OUTLET WITHIN 5-0" OF EQUIPMENT. MECH. ROOM 0003 DWS -1 DOMESTIC WATER SOFTENER - - _ MECH. ROOM 0003 RPBP -1 REDUCE PRESSURE BACKFLOW PREVENTER 1" 155 -330 P.D.I. CERTIFIED MECH. ROOM 0003 RPBP -2 REDUCE PRESSURE BACKFLOW PREVENTER - MECH. ROOM 0003 BFP -1 BACKFLOW PREVENTER .57 1 - MECH. ROOM 0003 HWRP -1 HOT WATER RECIRCULATING PUMP 120' F .40 1 MECH. ROOM 0003 HWRP -2 HOT WATER RECIRCULATING PUMP 140' F _ WATER PRESSURE REGULATOR MECH. ROOM 0003 PRV -1 AT DISHWASHER PRV -2 WATER PRESSURE REGULATOR _ - DO NOT USE AS GROUND CONNECTION GI -1 GREASE INTERCEPTOR KITCHEN 0012 MECH. ROOM 0003 GPR -1 GAS PRESSURE REGULATOR _ - DO NOT USE AS GROUND CONNECTION OUTSIDE AT BARN O GPR -2 GAS PRESSURE REGULATOR _ - DO NOT USE AS GROUND CONNECTION MECH. ROOM 0003 GPR -3 GAS PRESSURE REGULATOR NOTE: 10 REFER TO 'L' SERIES DRAWINGS FOR LOCATION. WATER HAMMER ARRESTER SCHEDULE MARK WADE / J.R. SMITH # ZURN ! I.P.S. F.U. RATING , REMARKS A' W -5 5005 100 3/4" 1 -11 P.D.I. CERTIFIED B' W -10 5010 200 1" 12 -32 P.D.I, CERTIFIED C' W -20 5020 300 1" 33 -60 P.D.I. CERTIFIED D' W -50 5030 400 1" 61 -113 P.D.I. CERTIFIED 'E' W -75 5040 500 1" 114 -154 P.D.I. CERTIFIED 'F' W -100 5050 600 1" 155 -330 P.D.I. CERTIFIED G•--- -' DWH-I csr,oUNt7 J01Wr UNION CAS OU1214ek 06 Cock TN�t2MasTAT 1 4 01P-T L564 "NIGH coNcIzsTs 'AP 4` O ccwc em u r-INI '*HEM b12dIN VAI.�/t✓ �t.00l2 FIt•IISIaEU FLe7 GYGI,E Go►- F�oLI�K• WJtJER -MA IU MtJt, t T vA yE BRINE MAKER 4. e . - w • eY- PASS VALV E NORMALLY CLOSED) RXW TREATED Q �•O WAT R� x 7tTv �0 W'fP, Irl CI�'I ATER 1 H T O DRAIN • n _ 4 INLET OUTLET VALVE 4 VALVE SAMPI mzm cor -t'K MRA G cKWA*1 GO ICoL EK. Er FEET 10 DOMESTIC WATER SOFTENER PIPING DETAIL tDWS -11 11 DOMESTIC WATER HEATER PIPING DETAIL DWH -11 P502 NO SCALE P502 NO SCALE / o� 'fo C� _t" t~ "V F,S 40 l > 5 ` Zt F FS, F.S. =FLcW sWrr6�4 �-:1PE2Vi5Ec> `"&LVE 1WRINKLER PIPING SCHEMATIC (- 'lt- I15t�EP Fl.c� fill z 4 "W AuIloF- 9CP5-- GII 15 P502 r f,ELV69P (,!:)./EK. Fog VIN`tl, 'fit,E h1A�l -SK►p Gv�/E.iZ A66fA,.r;:, To FL CW ► ozct, rvw FV-F, I. Al. 4" LONG. 4I� PAD GREASE INTERCEPTOR DETAIL 14 NO SCALE P502 PIPE 5t..t�Ei<E � �E pE'tAll. 3l P5o t (->YP) ±5-0 14- 4„w f" cowfRC41 d(LtFI�E 4