Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0815.93.99
H H7 PrA I� " - i ��L ■ r, =11 - r1 �■ it= Sil I. II� 1 - � Q C r c � Q � 1 _ � I�I�eI a ��..� ►� . ll�i�w m w�� _ 1 cl C2 C 5 I ; C6 INCORPORATED i PLANNERS INTERIOR DESIGNERS O COPYRIGHT 1991 ff INDIANAPOLIS. INDIANA 46240 (317) 848 -7800 SCOPE QRAININGS the pwW 1vV Sow of of a. Bw 2 . i 5. O f SD2 w Ian cro i i I G2 G2 - -_ G2 G2 OV aS� CAN 2008 _009 '' G2 SD2 ; SD2 SD2 SD2 SD3 SD3 -450 -375 -375 S OR. -375 -375 -400 -400 SD52,0 0 , - 75- 2' 1f k.i' TY P. RV -1 TYP. 3 17 T 3 1 HS L.__� 3 4 "HHS 17 v K 1■ + -47D5 t -47D5 t -42D5 -42D5 i - 50 � ' 1 t_E T . CLAsspoo y CLA _ - V 03` 2019 2C 18 19 450 0 i O 450 T i _0UNS. 202 8 SD2 G2 `1 -325 T 2025' 8 - - - - - -- — - - SD2 2 -275 G2 - -300 G C0jNS.� 2026 --,r- �-- . G2 SD2 -300 iEi , I i i 4 C5 C6 ' C7 �' i C8 ' Cy (C � i 55 51 55 'r I I - -ACA �5 - -�5 UPPER LEVEL PLAN AREA "C" - HVAC SCALE: 1/87 = l'-O" )TE: DIVISION 15 CONTRACTOR IS REQUIRED TO COORDINATE DIFFUSER & REGISTER LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS. PLAN NOTES: 10 PROVIDE VOLUME DAMPER AT EACH BRANCH DUCT, TYPICAL. 20 PROVIDE CLEANOUT ACCESS DOOR IN GREASE DUCT ABOVE CEILING; COORDINATE WITH LOCATION OF SHAFT ACCESS DOOR. 30 14 "x14" TRANSFER AIR OPENING ABOVE CEILING BETWEEN PLENUMS; REMOVE DRYWALL. ® 60 "x30" RETURN AIR DUCT OPENING INTO PLENUM ABOVE CORRIDOR CEILING. PROVIDE FIRE DAMPER AT CHASE WALL PENETRATION. 50 30 "x30" RETURN AIR DUCT OPENING INTO PLENUM ABOVE CORRIDOR CEILING. PROVIDE FIRE DAMPER AT CHASE WALL PENETRATION. © SPIN -IN FITTING WITH VOLUME DAMPER, TYPICAL. 70 FLEX DUCT, 6 FEET MAXIMUM (TOTAL). ® 12" x 12" TRANSFER AIR DUCT ABOVE CEILING. PROVIDE INTERNAL INSULATION, 24" LEGS -FOR SOUND ATTENUATION. 90 GREASE RATED WELDED STEEL EXHAUST DUCT; REFER TO SPECIFICATIONS. 10 PROVIDE 18" LINED PLENUM ATTACHED TO REAR OF LINEAR BAR GRILLE DIFFUSER. 11 SEE EXHAUST FAN DETAIL 13 -M403. 1 SEE RELIEF HOOD DETAIL 22 -M403; TYP. OF "RV -1'S" 10 PROVIDE DUCT WITH DIMENSION OF VENTILATOR NECK BETWEEN VENTILATOR AND 12" INTO RETURN AIR PLENUM BELOW. INSTALL MOTORIZED DAMPER ASSEMPLY WITHIN PLENUM. 14 COORDINATE ALL ROOF /SLAB OPENINGS STRUCTURAL TRADES AND DRAWINGS. TYPICAL. 15 48 "X24" MOTORIZED DAMPER ASSEMBLY AND SHEET METAL WALL SLEEVE BY DIV. 15. CONNECT TO EXTERIOR LOUVER BY OTHERS. REFER TO ARCH. DWGS FOR LOCATION OF ELEVATOR SHAFT VENT LOUVER. DAMPER MOTOR WIRED BY DIVISION 16. 16 6 "X6" TRANSFER AIR DUCT. 10 3 -WAY CONTROL VALVE FOR HOT WATER COIL IN VAV BOX. 18 2 -WAY CONTROL VALVE FOR HOT WATER COIL IN VAV BOX. 19 3/4" HHS AND 3/4" HHR PIPE RUN OUT TO VAV BOX. �0 PIPE ANCHORS. �1 PIPE GUIDES. © EXPANSION LOOP. �3 DUCT CENTERLINE AT APPROX. 10' -2" AFF; COORDINATE WITH STRUCTURE, LIGHTS, PIPING, FIRE PROTECTION, ETC. BOTTOM OF AIR TERMINAL AT APPROX. 9'08" AFF; COORDINATE WITH STRUCTURE, LIGHTS, PIPING, FIRE PROTECTION, ETC. a5 ROUTE DUCT AS HIGH AS POSSIBLE. COORDINATE WITH STRUCTURE, LIGHTS, PIPING, FIRE PROTECTION, ETC. © REFER TO DRAWING M204 FOR CONTINUATION OF DUCTWORK, PIPING, IN SHAFT. NORTH NWH UPPER LEVEL KEY PLAN E L55 CSO ARCHITECTS INCORPORATED ARCHITECTS PLANNERS INTERIOR DESIGNERS O COPYRIGHT 1991 9100 KEYSTONE CROSSING INDIANAPOLIS. INDIANA 46240 (317) 848 -7800 SCOPE QRAININGS the pwW 1vV Sow of of a. Bw .«.." ae .» bo. Of sw— 'b"r»aw+od awe +aa VAW- e�.oea°'a%v it Cw oonpwo. a ow nVsrwro.b a M ow e�er«e. a Y+soata « e�«alW, w ew0� oantac0an �. MnM� d It... ngoYW for M grey« z O V) w rn m m I 00 Z 0 Q Y d i Q d w d d 00 2 = 2 p O p z V Z U �Q W LLJ a <C �, ° z � I~ _ J �- cc Q U W U Ln In Q LLJ = CU Q D _ z Q LL 1 LL L.Lj Z J - < W � VJ LLJ cr (Lo' _j z U ly- LLJ QL Al No. cr_ PE60910310 •: STATE OF CERTIFIED BY wj.c'A %0.. SHEET NO M205 OF SHEETS FILE NO 92217