HomeMy WebLinkAbout0941.93.11No.
.� 910337 ; 0--
STATE OF i (�V
"
ND NO- 0,
0 N A L w
CERTIFIED BY:
DATE
C
EX. 8' OUT i
A 837.
EX. 8' IN
0 837.
EXISTING GRADE
T.C. = 849.70
0 +00 1 +00 LTVV
PROFILE ONE
REVISIONS
SIR. #503 LIVry 1MAL, IV% IV nL1YIVVL nniLn unL w STR. #5U4 I RLrLR. IV f1VLL' -v— "v
HYDRANT BACK TO NEW TAP AS SHOWN ON ENGINEER ABOUT ANY CONFLICTS.
UTILITY PLAN. I 1 I
zz I
PAUL I. CRIPE, INC.
7172 GRAHAM ROAD
INDIANAPOLIS, INDIANA 46250
f%17% AAA— 777
• CIVIL ENGINEERING CONCEPT CHK: DRAWN BY: H«�: ' . -50� DATE:
08/2S/93
• LAND SURVEYING K.M.T. VERT. , -3
• ARCHITECTURE ENG. CHK: DRFTNG. CHK: DRAWING TIYLE: SANITARY
• LAND PLANNING J
N
CLIENT:
KROGER
SEWER PLAN
NOTES:
1. CUTS SHOWN ARE APPROXIMATE, TAKEN FROM EXISTING GRADE TO INVERT OF PIPE.
2. ALL SANITARY MANHOLE CASTINGS SHALL BE:
NEENAH R -1642 OR EQUAL W /CONCEALED PICK HOLES.
3. EASEMENTS ARE SHOWN FOR REFERENCE ONLY AND DO NOT
NECESSARILY DEPICT ACTUAL RECORDED INFORMATION, SEE
RECORDED PLAT FOR EXACT INFORMATION.
4. THE CONTRACTOR WILL BE REQUIRED TO PROVIDE AS —BUILT DRAWINGS
TO THE ACCEPTING AGENCY TO CERTIFY THE ELEVATION AND SLOPE
OF SANITARY SEWERS. SEWERS INSTALLED AT A GRADE LESS THAN
REQUIRED BY THE AGENCY WILL NOT BE ACCEPTED. THE CONTRACTOR
SHALL PROVIDE FOR PERIODIC AS —BUILT CHECKS ON THE SEWER DURING
CONSTRUCTION TO ASSURE THAT DESIGN GRADE IS BEING MAINTAINED.
5. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR
EXCAVATIONS; FINAL RULE 29 CFR PART 1926, SUBPART 'P' APPLIES TO ALL
EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH.
6. IN ADDITION, EXCAVATIONS EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRE THE
DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER.
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH THE
ABOVE STATED REQUIREMENTS.
7. CONTRACTOR SHALL VERIFY LOCATION & INVERT ELEVATIONS OF EXISTING
SANITARY SEWER PRIOR TO START OF CONSTRUCTION.
DON'T
DIG
BLIND
'HOLEY MOLEr
SEZ:
1 -800- 382 -5544
CALL TOLL FREE
1 -800- 428 -5200
FOR CALLS OUTSIDE OF INDIANA
CAUTION
LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
SHOWN ON THIS PLAN ARE BASED UPON ABOVE
GROUND EVIDENCE (including, but not limited to,
manholes, inlets, valves, and marks made upon
the ground by others) AND ARE SPECULATIVE IN
NATURE. THERE MAY ALSO BE OTHER EXISTING
UNDERGROUND UTILITIES FOR WHICH THERE IS NO
ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE
GROUND EVIDENCE WAS OBSERVED. THE EXACT
LOCATIONS OF SAID EXISTING UNDERGROUND
UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR TO ANY AND ALL CONSTRUCTION.
KROGER STORE #J -959 - CARMEL, INDIANA
& PROFILE
DWG. TYPE FILE NUMBER I SHEET:
JOB NUMBER
C501