HomeMy WebLinkAbout06080001.11REELECTED CEILING PLAN
SCALE: 1/8" = 1' -0"
GENERAL CEILING NOTES
1. CEILING HEIGHT TO BE 9' -0" +/- UNLESS NOTED
OTHERWISE ON THE DRAWINGS.
2. ACOUSTICAL CEILING TO BE 2'X2' LAY -IN TILE WITH 15/16"
GRID.
3. ALL ROOMS OR AREAS TO HAVE INDIVIDUAL SWITCHING FOR
LIGHTING. AREAS WITH MORE THAN ONE (1) TYPE OF LIGHT
SOURCE SHALL BE SWITCHED FOR EACH INDIVIDUAL TYPE OF
FIXTURE / SOURCE
4. ENCLOSED OFFICES ARE TO BE SWITCHED SEPARATELY, WITH
SWITCH LOCATED AT 45" A.F.F. AND 6" FROM THE DOOR FRAME.
OTHER ARE TO BE SWITCHED PER OWNERS INSTRUCTIONS.
5. ELECTRICAL CONTRACTOR TO PROVIDE NIGHT LIGHT CIRCUITS
AND EMERGENCY LIGHTING AS REQUIRED BY CODE.
6. CONTRACTOR TO SUBMIT CATALOG CUTS OF NEW LIGHTING
FOR APPROVAL BY DESIGNER.
7. ALARMS AND STROBES BY ELECTRICAL CONTRACTOR AND
INSTALLED PER LOCAL FIRE CODES.
8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING
NECESSARY ENGINEERING / DESIGN BUILD SERVICES TO MODIFY
THE EXISTING HVAC & FIRE PROTECTION SYSTEMS, TO
ACCOMMODATE THE NEW TENANT LAYOUT. VERIFY FINAL DEVICE
LOCATIONS WITH THE DESIGNER, INCLUDING SPRINKLER HEADS,
AIR DIFFUSERS, AIR RETURNS, THERMOSTATS & LIFE SAFETY.
9. ALL BULKHEADS AT EXTERIOR GLAZING TO BE AT 8' -10"
AFF UNLESS NOTED OTHERWISE.
10. ALL BULKHEADS ABOVE UPPER CASEWORK /WALL CABINETS
TO HAVE 3/4" REVEAL BETWEEN CASEWORK AND BOTTOM OF
BULKHEAD. THESE BULKHEADS TO BE A 7' -6" AFF UNLESS
NOTED OTHERWISE. ALL BULKHEADS ABOVE UPPER CASEWORK
TO BE 1" DEEPER THAT CASEWORK.
11. SWITCHES IN ALL EXAM ROOMS (114, 115, 116, 117, 118,
119, 121, 122, 123, 124, 125, 126, 127, 128) TO BE 5' -0" AFF
ON CENTER.
LIGHTING LEGEND
2'x4' FLUORESCENT FIXTURE
OE EMERGENCY LIGHT
s2'X2' FLUORESCENT FIXTURE
BUILDING STANDARD AIR SUPPLY
VRI BUILDING STANDARD AIR RETURN
O RECESSED CAN
- - -- UNDERCABINET TASK LIGHT - ALKCO "LITTLE INCH"
OR EQUAL
SWITCH - NOTE: SWITCHES IN ALL EXAM ROOMS TO
BE 5' -0" AFF.
v
THREE -WAY SWITCH
E F EXHAUST FAN (SWITCH WITH CEILING LIGHT FIXTURE
IN TOILET ROOMS)
CEILING MOUNTED EXIT SIGN
DRYWALL BULKHEAD
CEILING HEIGHT INDICATOR
SPECIFIC KEY NOTES _(D
1. BULKHEAD ABOVE CASEWORK WITH REVEAL. SEE ELEVATIONS.
2. NOT USED.
3. BULKHEAD AT 12' -0" AFF TO ALIGN WITH TOP OF WINDOW
MULLION. SEE DETAIL /SECTION #9 ON SHEET A -6.
4. VERIFY SWITCHING LOCATIONS FOR CORRIDORS AND WAITING
ROOM(S),
5. PROVIDE ADEQUATE COOLING FOR SERVER ROOM.
6. LAY -IN TILE CEILING (AT 9' -0" AFF) TO DIE INTO 8' -11" AFF
BULKHEAD. SEE DETAIL /SECTION #9 ON SHEET A -6.
7. ALIGN.
.*ARTITION LEGEND
111111111111111111111111 ' •' � �
NEW PARTITION 4 7/8" WITH SOUND INSULATION UNLESS NOTED
OTHERWISE. 10' -0" H UNLESS NOTED OTHERWISE. SEE DETAIL #1
ON SHEET A -1.1.
NEW LOW WALL PARTITION - SEE ELEVATIONS FOR HEIGHTS
NEW PARTITION 4 7/8" TO DECK WITH SOUND INSULATION. SEE
DETAIL #2 ON SHEET A -1.1.
NEW PAR111ION TO DECK - 7 1/4" PLUMBING WALL WITH SOUND
INSULATION. SEE DETAIL #3 ON SHEET A -1.1.
*THE BUILDING /SHELL IS NEW CONSTRUCTION AND WAS
NOT COMPLETE FOR FIELD VERIFICATION PRIOR TO THIS
PLAN /SUITE BEING ISSUED FOR CONSTRUCTION.
11 /n tiewl /101 rs
S-uiae; .,'33
.,,. .
,v,,,
A DIVISION OF J. GREG ALLEN
802 MULBERRY STREET, B -I C,.:.,0::R R A N
NOBLESVILLE, INDIANA 46060
317. 773. 9804 VOICE M
317.773 .9828 FAX WWW.CURRAN- ARCHITECTURE.COM
02 ISSUED FOR STATE PLAN REVIEW 9/29/0
01 ISSUED FOR 90% REVIEW 8/03/06
N0. DESCRIPTION..,.:,:.... DATE
THIS DRAWING SET IS PROVIDED IN ° ONFf ENCE AND SHALL
BE USED ONLY AS INTENDED BY THE.AGREEMENT WITH LOHR
DESIGN, INC. NO OTHER USE OR DUPLICATION MAY BE MADE
WITHOUT PRIOR WRITTEN CONSE T.::QF ...LO.HR DESIGN, INC.
ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY
RESERVED.
MERIDIAN PEDIATRICS
\0xxIiIIIIltI / /
\�N
M. CI I /// .
c�P.•��6 \StRfa •.
• 9600043
STATE OF
I'
REFLECTED
CEILING PLAN
PROJECT NO.: 06- 561.001
DATE: 6/30/06
SCALE:1 /8" =1 ' -0"
DRAWN: AW /JB
CHECKED: MDL
,---• s
A -2
PLAN NORTH