HomeMy WebLinkAbout06080001.14I
i
f'r
r
i
H
R/
11' -7"
-� J v ,
m
BUSINESS OFFICE Roots 111
A
SCALE: 3/8" = 1' -0"
LAMINATE BACK
SIDE OF
BACKSPLASH
WITH BLACK PL.
V.I.F.
V.I.F. EQ. 11 EQ. L EQ. EQ. EQ. EQ.
N
I
i-
0
T
N
v
PHYSICIANS Roots 120
SCALE: 3/8" = 1' -0"
3' -10"
urnnn roeur
PL -4, BACK
OF 1/4'
REVEAL ONLY,
TYP.
c
I
a
7' -0"
EXAM —
B
MIDMARK
CASEWORK
(VERIFY)
SCALE: 3/8" =
1' -0"
PROVIDE GROMMETS IN
TYPICAL EXAM ROOM
CONTACT: JOHN
OSSIM (MIDMARK),
PH: 317 - 409 -4867
N
F
6'-2 1/2"
V.I.F.
EQ. EQ.
I
N
0
I
N
0
I
n
5' -0"
EQ. EQ.
EXAM— MIDMARK CASEWORK (VERIFY)
C
SCALE: 3/8" = 1' -0" TYPICAL EXAM ROOM
CONTACT: JOHN OSSIM (MIDMARK), PH: 317 - 409 -4867
ri
ADJUSTABLE SHELVES,
I
TYP.
PROVIDE GROMMETS IN
FIELD AS NEEDED
CO
GLASS
N
RAKKS,
_
EH -1818
WOOD
FRAME
COUNTER
o
SUPPORT
I
BRACKET, TYP.
N
PROVIDE
-
BLOCKING AND
VERIFY
BACKSPLASH HEIGHT SHALL
QUANTITY AND
o
APPROPRIATE
I
SPACING.
~'
F
6'-2 1/2"
V.I.F.
EQ. EQ.
I
N
0
I
N
0
I
n
5' -0"
EQ. EQ.
EXAM— MIDMARK CASEWORK (VERIFY)
C
SCALE: 3/8" = 1' -0" TYPICAL EXAM ROOM
CONTACT: JOHN OSSIM (MIDMARK), PH: 317 - 409 -4867
ri
q[ 3' -6"
CORRIDOR ROOM 135 WAITING ROOM 100
SCALE: 3/8 = 1'-0" SCALE: 3/8" = 1' -0"
NOTE: DETAILS AND FINAL DESIGN TO FOLLOW.
PC
I
a
IM
ZIUM
1' -6"
Ir 711
I� WAITING ROOM 100
r\
SCALE: 3/8" = 1' -0"
NOTE: DETAILS AND FINAL DESIGN TO FOLLOW.
a
a
s
CO
_I
iD
I
N
I
N
0
I
V -11"
LOHRDESIGN
ADJUSTABLE SHELVES "'`
TYP. ac
-,
18" DEEP COUNTER
RADIUS EDGE
SLIDING SHELVES ON
TRACK, TYP.
CORRIDOR
ROOM #129
SCALE: 3/8" = 1' -0"
3' -10"
CORRIDOR ROOM 137
G
SCALE: 3/8" = 1' -0"
4' -1 "•
EQ. 3, —O" EQ.
L
CORRIDOR ROOM 101
SCALE: 3/8" = 1' -0"
NOTE: VERIFY FINAL NICHE SIZE WITH INTERIOR
DESIGNER PRIOR TO CONSTRUCTION. PROVIDE
BLOCKING FOR MAGAZINE RACK.
CLEAR, TEMPERED
SLIDING GLASS
WINDOWS, WITH
LOCKS, TYP.
SOLID SURFACE
'L -4, BACK
►F 1/4"
EVEAL ONLY,
YP.
HEAVY DUTY,
ADJUSTABLE
MELAMINE
SHELVING,
BRACKETS AND
STANDARDS.
VERIFY SPACING
AND QUANTITY OF
STANDARDS.
PROVIDE BLOCKING
AS NEEDED.
_
3' -0" I 1' -g„
LAUNDRY ROOM 146
SCALE: 3/8" = 1' -0"
GENERAL ELEVATION NOTES
1. ALL CASEWORK TO RECEIVE VINYL BASE.
2. ALL SHELVING SHOWN WITHIN CASEWORK TO HAVE
ADJUSTABLE HEIGHT UNLESS NOTED OTHERWISE.
3. ALL FILE DRAWERS TO BE CAPABLE OF UTILIZING
PENDAFLEX FILE HANGERS WITH TAB /LABELS.
4. COUNTER SUPPORTS ARE SPECIFIED AS "RAKKS ".
EQUALS ARE ACCEPTABLE IF SUBMITTED AND APPROVED BY
DESIGNER.
5. PROVIDE 3/4" REVEAL BETWEEN ALL UPPER CASEWORK
WITH BULKHEAD ABOVE.
6. ALL INTERIOR OF ENCLOSED CASEWORK TO BE
MELAMINE.
*THE BUILDING /SHELL IS NEW CONSTRUCTION AND WAS
NOT COMPLETE FOR FIELD VERIFICATION PRIOR TO THIS
PLAN /SUITE BEING ISSUED FOR CONSTRUCTION.
�. •,c<23,
V" JL
A DIVISION Of J. GREG ALLEN
802 MULBERRY STREET, B -1
NOBLESVILLE, INDIANA 46060 .......U.......R R A N
317. 773. 9804 VOICE 113 1
317. 773 . 9828 FAX WWW.CURMN- ARCHITECTURE.COM
02 ISSUED FOR STATE PLAN. REVI I EW 9/29/0
01 ISSUED FOR 90% REVIEW ° 8/03/06
NO. DESCRIPTION DATE
THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL
BE USED ONLY AS INTENDED BY.THE.AGREEMENT WITH LOHR
DESIGN, INC. NO OTHER USE OR-DUPLICATION MAY BE MADE
WITHOUT PRIOR WRITTEN CONSENT JOFLOHR DESIGN, INC.
ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY
RESERVED.
MERIDIAN PEDIATRICS
PINNACLE POINTE'
MEDICAL PLAZA `=
12065 OLD MERIDIAN ST.
CARM EL, IN 4603
N M
• 9600043
i SWE DF \
7
EMMS 11)*/ff -
ELEVATIONS
PROJECT NO.: 06- 561.001
DATE: 6/30.Z06
SCALE:3 f 8 " =1 ' -0"
DRAWN: AW /JB
CHECKED: MDL
APPROVED:
A -5
ILmrr-r«U
Itmrr -KLU
SOLID SURFACE
GLASS
GLASS
TRANSACTION COUNTER
WOOD
FRAME
/
/
AT 40" AFF
BACKSPLASH HEIGHT SHALL
4
1' -0"
ALIGN WITH TOP OF
SS -1
A -6
TRANSACTION COUNTER IN THIS
ROOM
WOOD TRIM, TYP.
°
e
VERIFY PRINTER SIZE
°
e
PRINTEI
WITH TENANT
FILE
FILE
SHELF
d
e
SLIDING SHELVES ON
FILE)
(ILE)
TRACK, TYP.
FILE
FILE
STANDARD HANGING
FILE FOLDERS WITH
1' -6"
1' -6"
2' -10 ";
TABS SHALL FIT INTO
q[
CASEWORK - PROVIDE
NURSE
SIDE RAILS FOR
ROOM 144
FOLDERS
SCALE: 3/8" = 1' -0"
q[ 3' -6"
CORRIDOR ROOM 135 WAITING ROOM 100
SCALE: 3/8 = 1'-0" SCALE: 3/8" = 1' -0"
NOTE: DETAILS AND FINAL DESIGN TO FOLLOW.
PC
I
a
IM
ZIUM
1' -6"
Ir 711
I� WAITING ROOM 100
r\
SCALE: 3/8" = 1' -0"
NOTE: DETAILS AND FINAL DESIGN TO FOLLOW.
a
a
s
CO
_I
iD
I
N
I
N
0
I
V -11"
LOHRDESIGN
ADJUSTABLE SHELVES "'`
TYP. ac
-,
18" DEEP COUNTER
RADIUS EDGE
SLIDING SHELVES ON
TRACK, TYP.
CORRIDOR
ROOM #129
SCALE: 3/8" = 1' -0"
3' -10"
CORRIDOR ROOM 137
G
SCALE: 3/8" = 1' -0"
4' -1 "•
EQ. 3, —O" EQ.
L
CORRIDOR ROOM 101
SCALE: 3/8" = 1' -0"
NOTE: VERIFY FINAL NICHE SIZE WITH INTERIOR
DESIGNER PRIOR TO CONSTRUCTION. PROVIDE
BLOCKING FOR MAGAZINE RACK.
CLEAR, TEMPERED
SLIDING GLASS
WINDOWS, WITH
LOCKS, TYP.
SOLID SURFACE
'L -4, BACK
►F 1/4"
EVEAL ONLY,
YP.
HEAVY DUTY,
ADJUSTABLE
MELAMINE
SHELVING,
BRACKETS AND
STANDARDS.
VERIFY SPACING
AND QUANTITY OF
STANDARDS.
PROVIDE BLOCKING
AS NEEDED.
_
3' -0" I 1' -g„
LAUNDRY ROOM 146
SCALE: 3/8" = 1' -0"
GENERAL ELEVATION NOTES
1. ALL CASEWORK TO RECEIVE VINYL BASE.
2. ALL SHELVING SHOWN WITHIN CASEWORK TO HAVE
ADJUSTABLE HEIGHT UNLESS NOTED OTHERWISE.
3. ALL FILE DRAWERS TO BE CAPABLE OF UTILIZING
PENDAFLEX FILE HANGERS WITH TAB /LABELS.
4. COUNTER SUPPORTS ARE SPECIFIED AS "RAKKS ".
EQUALS ARE ACCEPTABLE IF SUBMITTED AND APPROVED BY
DESIGNER.
5. PROVIDE 3/4" REVEAL BETWEEN ALL UPPER CASEWORK
WITH BULKHEAD ABOVE.
6. ALL INTERIOR OF ENCLOSED CASEWORK TO BE
MELAMINE.
*THE BUILDING /SHELL IS NEW CONSTRUCTION AND WAS
NOT COMPLETE FOR FIELD VERIFICATION PRIOR TO THIS
PLAN /SUITE BEING ISSUED FOR CONSTRUCTION.
�. •,c<23,
V" JL
A DIVISION Of J. GREG ALLEN
802 MULBERRY STREET, B -1
NOBLESVILLE, INDIANA 46060 .......U.......R R A N
317. 773. 9804 VOICE 113 1
317. 773 . 9828 FAX WWW.CURMN- ARCHITECTURE.COM
02 ISSUED FOR STATE PLAN. REVI I EW 9/29/0
01 ISSUED FOR 90% REVIEW ° 8/03/06
NO. DESCRIPTION DATE
THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL
BE USED ONLY AS INTENDED BY.THE.AGREEMENT WITH LOHR
DESIGN, INC. NO OTHER USE OR-DUPLICATION MAY BE MADE
WITHOUT PRIOR WRITTEN CONSENT JOFLOHR DESIGN, INC.
ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY
RESERVED.
MERIDIAN PEDIATRICS
PINNACLE POINTE'
MEDICAL PLAZA `=
12065 OLD MERIDIAN ST.
CARM EL, IN 4603
N M
• 9600043
i SWE DF \
7
EMMS 11)*/ff -
ELEVATIONS
PROJECT NO.: 06- 561.001
DATE: 6/30.Z06
SCALE:3 f 8 " =1 ' -0"
DRAWN: AW /JB
CHECKED: MDL
APPROVED:
A -5