HomeMy WebLinkAbout06080001.16ELECTRICAL PLAN
SCALE: 1/8" = 1' -0"
GENERAL ELECTRICAL NOTES
1. THESE DRAWINGS ARE FOR QUANTITY AND LOCATION OF DEVICES ONLY. REFER TO
ENGINEERING DOCUMENTS FOR FURTHER INFORMATION.
2. ALL ELECTRICAL RECEPTACLES NEAR WATER SOURCES SHALL BE 'GFI' TYPE PER CODE.
3. INDICATOR "D" NEXT TO A RECEPTACLE INDICATES DEDICATED CIRCUIT.
4. TEMPORARILY LOCATE ANY / ALL ALARMS AND DETECTORS DURING CONSTRUCTION OF A
SPECIFIC AREA. REINSTALL AS NECESSARY AND VERIFY WITH CODE.
5. ELECTRICAL CONTRACTOR TO PROVIDE ALL NEW POWER AND TO PROVIDE CONDUIT AND
JUNCTION BOXES FOR DATA / PHONE CONTRACTOR TO COORDINATE WITH TENANT.
6. EXTEND OUTLETS FLUSH WHERE INTERFACES WITH CASEWORK OR NEW CONSTRUCTION.
COORDINATE CASEWORK WITH INSTALLER.
7. ALL NEW RECEPTACLES AND SWITCH PLATES SHALL BE (IVORY) UNLESS NOTED OTHERWISE.
8. ALL POWER AND COMMUNICATION SHOWN IS NEW. CONTRACTOR TO VERIFY IN FIELD
EXISTING POWER AND COMMUNICATIONS RECEPTACLES.
9. FINAL EQUIPMENT AND FIXTURE LOCATIONS TO BE VERIFIED WITH TENANT.
10, IF REQUIRED ALL FLOOR AND JUNCTION BOXES TO BE FLUSH FLOOR MOUNTED.
11. VERIFY EXISTING RECEPTACLE LOCATIONS WITH NEW AND REUSE ANY EXISTING
RECEPTACLES OR JUNCTION BOXES WHEN POSSIBLE OR FEASIBLE.
12. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR BALANCING (INDEXING) THE
ELECTRIC PANEL.
*13. ALL ELECTRICAL OUTLETS IN THE FOLLOWING ROOMS /AREAS TO BE CHILD PROOF:
WAITING ROOMS, ALL EXAM ROOMS, TOILET ROOMS, AND CORRIDORS.
14. VERIFY TYPE(S) OF RECEPTACLE FOR TENANT PROVIDED EQUIPMENT AND APPLIANCES.
SPECIFIC KEY NOTES 0
1. PROVIDE GROMMET WITH CAP IN WORK SURFACE. VERIFY FINAL LOCATION AND QUANTITY WITH
TENANT.
2. OUTLET TO BE LOCATED WITHIN MICROWAVE CASEWORK /SHELF. VERIFY HEIGHT IN FIELD.
3. VERIFY ALL ELECTRICAL /PHONE /DATA NEEDS IN THIS ROOM WITH TENANT'S IT CONSULTANT.
4. PROVIDE ALL NECESSARY ELECTRICAL REQUIREMENTS FOR WASHING MACHINE AND DRYER.
5. LOCATE DATA /PHONE OUTLET AND ELECTRICAL OUTLET WITHIN PRINTER SHELF. SEE
ELEVATIONS FOR SHELF LOCATION. VERIFY HEIGHT.
6. OUTLET (FOR REFRIGERATOR) ON EMERGENCY, TEMPORARY BATTERY BACK -UP SYSTEM.
7. THE SERVER OUTLET(S) AND PHONE SYSTEM OUTLET(S) TO BE ON EMERGENCY, TEMPORARY
BATTERY BACK -UP SYSTEM.
8. SEE PRICING ALTERNATE(S) #2 ON SHEET A -1 FOR PROVIDING CABLE OUTLET AT 7' -6" AFF.
9. COORDINATE ELECTRICAL /PHONE /DATA OUTLETS IN THIS ROOM WITH MANUFACTURER PROVIDING
CASEWORK.
10. PROVIDE FIRE RETARDANT PLYWOOD PANEL MOUNTED TO WALL FOR TELEPHONE SYSTEM
MOUNTING. VERIFY FINAL LOCATION AND REQUIREMENTS WITH TENANT'S IT CONSULTANT.
11. COORDINATE WITH THE CASEWORK CONTRACTOR TO ALLOW FLOOR RECEPTACLES TO CLEAR THE
PLASTIC LAMINATE SUPPORTS AND BE LOCATED ON THE CORRECT SIDE OF THE SUPPORTS.
12. PROVIDE GFI POWER FOR AQUARIUM. VERIFY NEEDS WITH TENANT /VENDOR.
13. VERIFY NUMBER OF PHONE /DATA LINES NEEDED IN THIS ROOM FOR TENANT'S CREDIT CARD
PROCESSING MACHINES. VERIFY WITH TENANT AND TENANT'S IT CONSULTANT.
14. VERIFY FINAL ELECTRICAL & PHONE /DATA OUTLETS IN THIS LOCATION WITH FINAL CASEWORK
DESIGN.
ELECTRICAL LEGEND
+48•
GR GFI (ANTI SHOCK) DUPLEX AT SPECIFIC HEIGHT
DUPLEX RECEPTACLE AT
BLDG. STANDARD HEIGHT
QUADRAPLEX RECEPTACLE AT
BLDG. STANDARD HEIGHT
P PHONE /DATA OUTLET
0o DEDICATED RECEPTACLE
CABLE / DUPLEX OUTLET ® 7' -6" AFF FOR WALL HUNG TV -
Tv SEE PRICING ALTERNATE(S) ON SHEET A -1
r FLUSH FLOOR PHONE /DATA OUTLET
FLUSH FLOOR ELECTRICAL OUTLET
aW WALL PHONE MOUNTED AT 54" AFF TO TOP OF PHONE
220V OUTLET
*THE BUILDING /SHELL IS NEW CONSTRUCTION AND WAS
NOT COMPLETE FOR FIELD VERIFICATION PRIOR TO THIS
PLAN /SUITE BEING ISSUED FOR CONSTRUCTION.
L D H R j /iiiii�% j /iieiii % /liar,/ % %iiiiiivi % ��or
�aiii/� % milli �iiiiiii% % iiiiii� G r
%.%1 /G ir% %%�'
4,29 N
IN i
f.r
V..IL,
A, DIVISION OF J. GREG ALLEN
802 MULBERRY STREET, B -I U R R A N
NOBLESVILLE, INDIANA 46060 rC
317. 773. 9804 VOICE ARCHITECTUR
317. 773 . 9828 FAX WWW.CURF AN- ARCHITECTURE.COM
02 ISSUED FOR STATE PLAN REVIEW 9/29/0
01 ISSUED FOR 90% REVIEW 8/03/06
NO. I DESCRIPTION I DATE
THIS DRAWING SET IS PROVIDED IN :CONFIDENCE AND SHALL
BE USED ONLY AS INTENDED BY THE AGREEMENT WITH LOHR
DESIGN, INC. NO OTHER USE OR DUPLICATION MAY BE MADE
WITHOUT PRIOR WRITTEN CONSENT OF LOHR DESIGN, INC.
ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY
RESERVU).
M, Cl(/
No.
• 9600043
STATE OF
ELECT141CAL,
VOICE /DATA
PLAN
PROJECT NO.: 06- 561.001
DATE: 6/30/06
SCALE:l Z8 " =1 ' -0"
DRAWN: AW/JB
CHECKED: MDL
APPROVED:
E -1
PLAN NORTH