HomeMy WebLinkAbout06080001.18FINISH PLAN
SCALE: 1/8" = 1' -0"
GENERAL FINISH NOTES
1. ALL PAINTED FINISHES SHALL BE NO LESS THAN ONE (1)
COAT PRIMER AND TWO (2) COATS FINISH PAINT.
2. ALL FINISHES AND METHODS OF ATTACHMENT SHALL MEET
THE REQUIREMENTS OF ALL LOCAL, STATE AND NATIONAL
CODES.
3. ALL FINISHES SHALL BE INSTALLED PER THE
MANUFACTURER'S INSTRUCTIONS.
4. AT AREA WHERE MULTIPLE FLOOR FINISHES MEET,
CONTRACTOR TO FEATHER THE SUB FLOOR AND /OR SHAVE THE
FLOOR FINISH FOR LEVEL TRANSITION.
5. PROVIDE VINYL TRANSITION STRIPS BETWEEN ALL CARPET
AND VCT / SHEET VINYL. COLOR AND STYLE TO BE SELECTED
FROM MANUFACTURER'S STANDARDS.
6. ALL CARPET SHALL BE DIRECT GLUE INSTALLATION PER
MANUFACTURER'S INSTRUCTIONS, UNLESS NOTED OTHERWISE.
7. PAINT ANY METAL ACCESS PANELS TO MATCH THE
ADJACENT WALL FINISH / CEILING FINISH.
8. ALL UNDERSIDES OF BULKHEADS TO BE PAINTED FLAT
FINISH UNLESS NOTED OTHERWISE.
9. ALL DRYWALL CEILINGS TO BE PAINTED FLAT FINISH UNLESS
NOTED OTHERWISE.
10. GENERAL CONTRACTOR TO SUBMIT SAMPLES OF ALL
INTERIOR FINISHES TO THE INTERIOR DESIGNER FOR APPROVAL
PRIOR TO INSTALLATION.
11. ALL WINDOW FRAMES AND DOOR FRAMES TO BE PAINTED
SEMI -GLOSS FINISH UNLESS NOTED OTHERWISE.
12. CONTRACTOR TO SUBMIT CUTTING FROM CURRENT RUN /
DYE LOT OF ALL FLOOR COVERINGS AND WALLCOVERINGS FOR
APPROVAL PRIOR TO INSTALLATION.
13. ALL CHANGE IN FLOORING MATERIALS FROM ROOM TO
ROOM SHALL OCCUR AT CENTERLINE OF DOOR UNLESS NOTED
OTHERWISE.
14. MANUFACTURER'S RECOMMENDED INSTALLATION IS
MANDATORY.
15. INSTALL THREE (3) LENGTHS / WIDTHS OF WALLCOVERING,
PER PATTERN, FOR DESIGNER'S APPROVAL. SHOULD ANY
DEFECTS BE FOUND IN THE WALLCOVERING, NOTIFICATION TO
THE SUPPLIER IS TO BE IMMEDIATE, NO CLAIMS WILL BE
ACCEPTED FOR FAULTY MATERIAL AFTER MORE THAN THREE (3)
LENGTHS / WIDTHS HAVE BEEN APPLIED.
16. ALL FINISHES, MAINTENANCE AND WARRANTY INFORMATION
TO BE SUBMITTED AS SHOP DRAWINGS TO THE INTERIOR
DESIGNER PRIOR TO THE START OF ANY WORK. ITEMS NOT
SUBMITTED ARE THE RESPONSIBILITY OF THE CONTRACTOR.
17. ANY DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION
OF THE ARCHITECT, OWNER AND INTERIOR DESIGNER PRIOR TO
THE COMPLETION OF A TASK.
18. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
ALL CONDITIONS ON THE SITE PRIOR TO ANY FINISH BEING
APPLIED. CONFIRMATION OF FINISHES IN THE EVENT OF NOT
BEING NOTED IS THE CONTRACTOR'S RESPONSIBILITY.
19. FLOORING MATERIALS SHALL BE DOCUMENTED IN A
SEAMING DIAGRAM FORMAT AND SUBMITTED FOR REVIEW BY THE
INTERIOR DESIGNER.
20. ALL WINDOW SILLS TO BE SS -2.
21. H ARROWS INDICATE DIRECTION "PLANKS" SHOULD
RUN.
SPECIFIC KEY NOTES G)
1. VWC -2.
2. VWC -3.
*THE BUILDING /SHELL IS NEW CONSTRUCTION AND WAS
NOT COMPLETE FOR FIELD VERIFICATION PRIOR TO THIS
PLAN /SUITE BEING ISSUED FOR CONSTRUCTION.
A
iii / �riiin �iiiiiiir /,
LOHR� i� ��
<
A DIVISION OF J. GREG ALLEN
802 MULBERRY STREET, B -I
NOBLESVILLE, INDIANA 46060
317. 773 . 9804 VOICE
317. 773 . 9828 FAX
02 ISSUED FOR STATE PLAN REVIEW 9/29/0
01 ISSUED FOR 907 REVIEW 8/03/06
N0. DESCRIPTION - - -- � - DATE
THIS DRAWING SET IS PROVIDED IN:.CONFDENCE AND SHALL
BE USED ONLY AS INTENDED BY ,THE AGREEMENT WITH LOHR
DESIGN, INC. NO OTHER USE OR DUPLICATION MAY BE MADE
WITHOUT PRIOR WRITTEN CONSENT OF =>1OHR DESIGN, INC.
ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY
RESERVED.
MERIDIAN PEDIATRICS
PINNACLE POINTE
MEDICAL PLAZA.
12065 OLD MERJDJA,N ST.
CARMEL, IN 46032
N0
• 9600043. #
STATE, OF
EfflRES 11)3(11(17
FINISH
PLAN
PROJECT NO.: 06- 561.001
DATE: 6.Z30/06
SCALE: 1 /8 " =1 V-0"
DRAWN: AW /JB
CHECKED: MDL
APPROVED:
F -1
PLAN NORTH