HomeMy WebLinkAbout06080001.23REFLECTED CEILING PLAN- 2ND FLOOR
SCALE: 1/8" = 1' -0"
REFLECTED CEILING PLAN- 1ST FLOOR
SCALE: 1/8" = 1' -0"
GENERAL CEILING NOTES
1. CEILING HEIGHT TO BE 9' -0" +/- UNLESS NOTED
OTHERWISE ON THE DRAWINGS.
2. ACOUSTICAL CEILING TO BE 2'X2' LAY -IN TILE WITH 15/16"
GRID.
3. ALL ROOMS OR AREAS TO HAVE INDIVIDUAL SWITCHING FOR
LIGHTING. AREAS WITH MORE THAN ONE (1) TYPE OF LIGHT
SOURCE SHALL BE SWITCHED FOR EACH INDIVIDUAL TYPE OF
FIXTURE / SOURCE
4. ENCLOSED OFFICES ARE TO BE SWITCHED SEPARATELY, WITH
SWITCH LOCATED AT 45" A.F.F. AND 6" FROM THE DOOR FRAME.
OTHER ARE TO BE SWITCHED PER OWNERS INSTRUCTIONS.
5. ELECTRICAL CONTRACTOR TO PROVIDE NIGHT LIGHT CIRCUITS
AND EMERGENCY LIGHTING AS REQUIRED BY CODE.
6. CONTRACTOR TO SUBMIT CATALOG CUTS OF NEW LIGHTING
FOR APPROVAL BY DESIGNER.
7. ALARMS AND STROBES BY ELECTRICAL CONTRACTOR AND
INSTALLED PER LOCAL FIRE CODES.
8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING
NECESSARY ENGINEERING / DESIGN BUILD SERVICES TO MODIFY
THE EXISTING HVAC & FIRE PROTECTION SYSTEMS, TO
ACCOMMODATE THE NEW TENANT LAYOUT. VERIFY FINAL DEVICE
LOCATIONS WITH THE DESIGNER, INCLUDING SPRINKLER HEADS,
AIR DIFFUSERS, AIR RETURNS, THERMOSTATS & LIFE SAFETY.
9. ALL BULKHEADS ABOVE UPPER CASEWORK /WALL CABINETS
TO HAVE 3/4" REVEAL BETWEEN CASEWORK AND BOTTOM OF
BULKHEAD. THESE BULKHEADS TO BE A 7' -6" AFF UNLESS
NOTED OTHERWISE. ALL BULKHEADS ABOVE UPPER CASEWORK
TO BE 1" DEEPER THAT CASEWORK.
10. ALL BULKHEADS AT EXTERIOR GLAZING TO BE AT 8' -10"
AFF UNLESS NOTED OTHERWISE.
LIGHTING LEGEND
(— 2'x4' FLUORESCENT FIXTURE
of EMERGENCY LIGHT
— �A
WALL MOUNTED LIGHT FIXTURE
A S
BUILDING STANDARD AIR SUPPLY
BUILDING STANDARD AIR RETURN
EXHAUST FAN (SWITCHED WITH CEILING LIGHT,
UNLESS NOTED OTHERWISE)
O
RECESSED CAN
0
ADJUSTABLE LOW VOLTAGE FIXTURE
'r
SCONCE ® 5' -9" AFF O.C.
BEGA, 4040P, BRUSHED STAINLESS STEEL, ADA
COMPLIANT.
SPOTLIGHT ON SUSPENDED TRACK @ 8' -0" AFF.
HEAD: MINOS SPOT, 220920MC, MATTE CHROME.
SUBMIT CUTSHEETS FOR COMPATIBLE TRACK FOR
APPROVAL.
DECORATIVE PENDANT
OCL, MONACO, MNC, 23" DIA., MATTE WHITE BOWL,
BRUSHED ALUMINUM /CHROME FINISH. 7' -2" AFF TO
BOTTOM OF FIXTURE.
LINEAR FLUORESCENT COVE LIGHTING AT PERIMETER
OF CLOUD / BULKHEAD. SET BACK TO CONCEAL.
®
CEILING MOUNTED EXIT SIGN
$
SWITCH
$3
THREE WAY SWITCH
4
CEILING HEIGHT INDICATOR
PARTITION LEGEND
NEW PARTITION, 4 7/8" UNLESS NOTED
OTHERWISE. 10' -0 "H UNLESS NOTED
OTHERWISE. SEE DETAIL 1, SHEET A -6.
NEW PARTITION BUILT TO THE DECK, SOUND
INSULATED. 4 7/8" - SEE DETAIL 2, SHEET
A -6. 7 1/4" - SEE DETAIL 3, SHEET A -6.
NEW LOW WALL PARTITION, 4 7/8 ".
SPECIFIC KEY NOTES 0
1. NOT USED.
2. SWITCHES FOR AREAS 252, 245, 242, 237, 204, 201, 233, 202,
226, 258, 220, & 257 TO BE AT THESE LOCATIONS. CONTACTER &
RELAY IF NECESSARY FOR LIGHT LOAD.
3. NO CEILING.
4. PROVIDE ADEQUATE COOLING FOR COMPUTER /PHONE EQUIPMENT
ROOM.
5. PROVIDE LIGHTING FOR PRE - FABRICATED SHOWER.
6. VERIFY LOCATION FOR EXHAUST FAN SWITCH (SEPARATE FROM
LIGHTING) WITH TENANT.
7. LIGHTING WITHIN THIS ROOM TO BE ON DIMMER SWITCH. VERIFY
SPECIFICATIONS WITH LIGHTING CONSULTANT.
8. SWITCHES FOR ROOMS 211, 214, 215, & 216 TO BE AT THESE
LOCATIONS. SWITCH SEPARATELY PER ROOM. IN ROOM 216,
RECESSED CANS AND COVE LIGHTING TO BE ON ONE SWITCH, AND
TRACK LIGHTING TO BE ON SEPARATE SWITCH. CONTACTER & RELAY
IF NECESSARY FOR LIGHT LOAD.
9. SWITCHES FOR AREAS 101 & 105 TO BE AT THIS LOCATION.
10. BULKHEAD AT 12' -10" AFF TO ALIGN WITH TOP OF WINDOW
MULLION. SEE DETAIL /SECTION 6 ON SHEET A -5.
*THE BUILDING /SHELL IS NEW CONSTRUCTION AND WAS
NOT COMPLETE FOR FIELD VERIFICATION PRIOR TO THIS
PLAN /SUITE BEING ISSUED FOR CONSTRUCTION.
F I
ld
429 N
S-�uae 333
-,;; - �sy -, ,r;: r %jam / ,,
A DIVISION OF J. GREG ALLEN
802 MULBERRY STREET, B -I U R R A N
NOBLESVILLE, INDIANA 46060
317. 773. 9804 VOICE
317. 773 . 9828 FAX WWW.CURRAN- ARCHITECTURE.com
03 ISSUED FOR STATE REVIEW 9/29/0
02 ISSUED FOR CLIEN,T:RUw 9/25/0
01 ISSUED FOR PLAN REVIEW 9/5/06
NO. DESCRIPTION DATE
THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL
BE USED ONLY AS INTENDED BY THE AGREEMENT WITH LOHR
DESIGN, INC. NO OTHER USE OR DUPLICATION MAY BE MADE
WITHOUT PRIOR WRITTEN CONSENT OF LOHR DESIGN, INC.
ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY
RESERVED.
REFLECTED
CEILING PLAN
PROJECT NO.: 06- 561.002
DATE: 7/5/06
SCALE:1 /8" =1' -0"
DRAWN: CO /JB
CHECKED: MDL
APPROVED: XXX
A -2
PLAN NORTH