HomeMy WebLinkAbout06080001.23REFLECTED CEILING PLAN- 2ND FLOOR SCALE: 1/8" = 1' -0" REFLECTED CEILING PLAN- 1ST FLOOR SCALE: 1/8" = 1' -0" GENERAL CEILING NOTES 1. CEILING HEIGHT TO BE 9' -0" +/- UNLESS NOTED OTHERWISE ON THE DRAWINGS. 2. ACOUSTICAL CEILING TO BE 2'X2' LAY -IN TILE WITH 15/16" GRID. 3. ALL ROOMS OR AREAS TO HAVE INDIVIDUAL SWITCHING FOR LIGHTING. AREAS WITH MORE THAN ONE (1) TYPE OF LIGHT SOURCE SHALL BE SWITCHED FOR EACH INDIVIDUAL TYPE OF FIXTURE / SOURCE 4. ENCLOSED OFFICES ARE TO BE SWITCHED SEPARATELY, WITH SWITCH LOCATED AT 45" A.F.F. AND 6" FROM THE DOOR FRAME. OTHER ARE TO BE SWITCHED PER OWNERS INSTRUCTIONS. 5. ELECTRICAL CONTRACTOR TO PROVIDE NIGHT LIGHT CIRCUITS AND EMERGENCY LIGHTING AS REQUIRED BY CODE. 6. CONTRACTOR TO SUBMIT CATALOG CUTS OF NEW LIGHTING FOR APPROVAL BY DESIGNER. 7. ALARMS AND STROBES BY ELECTRICAL CONTRACTOR AND INSTALLED PER LOCAL FIRE CODES. 8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING NECESSARY ENGINEERING / DESIGN BUILD SERVICES TO MODIFY THE EXISTING HVAC & FIRE PROTECTION SYSTEMS, TO ACCOMMODATE THE NEW TENANT LAYOUT. VERIFY FINAL DEVICE LOCATIONS WITH THE DESIGNER, INCLUDING SPRINKLER HEADS, AIR DIFFUSERS, AIR RETURNS, THERMOSTATS & LIFE SAFETY. 9. ALL BULKHEADS ABOVE UPPER CASEWORK /WALL CABINETS TO HAVE 3/4" REVEAL BETWEEN CASEWORK AND BOTTOM OF BULKHEAD. THESE BULKHEADS TO BE A 7' -6" AFF UNLESS NOTED OTHERWISE. ALL BULKHEADS ABOVE UPPER CASEWORK TO BE 1" DEEPER THAT CASEWORK. 10. ALL BULKHEADS AT EXTERIOR GLAZING TO BE AT 8' -10" AFF UNLESS NOTED OTHERWISE. LIGHTING LEGEND (— 2'x4' FLUORESCENT FIXTURE of EMERGENCY LIGHT — �A WALL MOUNTED LIGHT FIXTURE A S BUILDING STANDARD AIR SUPPLY BUILDING STANDARD AIR RETURN EXHAUST FAN (SWITCHED WITH CEILING LIGHT, UNLESS NOTED OTHERWISE) O RECESSED CAN 0 ADJUSTABLE LOW VOLTAGE FIXTURE 'r SCONCE ® 5' -9" AFF O.C. BEGA, 4040P, BRUSHED STAINLESS STEEL, ADA COMPLIANT. SPOTLIGHT ON SUSPENDED TRACK @ 8' -0" AFF. HEAD: MINOS SPOT, 220920MC, MATTE CHROME. SUBMIT CUTSHEETS FOR COMPATIBLE TRACK FOR APPROVAL. DECORATIVE PENDANT OCL, MONACO, MNC, 23" DIA., MATTE WHITE BOWL, BRUSHED ALUMINUM /CHROME FINISH. 7' -2" AFF TO BOTTOM OF FIXTURE. LINEAR FLUORESCENT COVE LIGHTING AT PERIMETER OF CLOUD / BULKHEAD. SET BACK TO CONCEAL. ® CEILING MOUNTED EXIT SIGN $ SWITCH $3 THREE WAY SWITCH 4 CEILING HEIGHT INDICATOR PARTITION LEGEND NEW PARTITION, 4 7/8" UNLESS NOTED OTHERWISE. 10' -0 "H UNLESS NOTED OTHERWISE. SEE DETAIL 1, SHEET A -6. NEW PARTITION BUILT TO THE DECK, SOUND INSULATED. 4 7/8" - SEE DETAIL 2, SHEET A -6. 7 1/4" - SEE DETAIL 3, SHEET A -6. NEW LOW WALL PARTITION, 4 7/8 ". SPECIFIC KEY NOTES 0 1. NOT USED. 2. SWITCHES FOR AREAS 252, 245, 242, 237, 204, 201, 233, 202, 226, 258, 220, & 257 TO BE AT THESE LOCATIONS. CONTACTER & RELAY IF NECESSARY FOR LIGHT LOAD. 3. NO CEILING. 4. PROVIDE ADEQUATE COOLING FOR COMPUTER /PHONE EQUIPMENT ROOM. 5. PROVIDE LIGHTING FOR PRE - FABRICATED SHOWER. 6. VERIFY LOCATION FOR EXHAUST FAN SWITCH (SEPARATE FROM LIGHTING) WITH TENANT. 7. LIGHTING WITHIN THIS ROOM TO BE ON DIMMER SWITCH. VERIFY SPECIFICATIONS WITH LIGHTING CONSULTANT. 8. SWITCHES FOR ROOMS 211, 214, 215, & 216 TO BE AT THESE LOCATIONS. SWITCH SEPARATELY PER ROOM. IN ROOM 216, RECESSED CANS AND COVE LIGHTING TO BE ON ONE SWITCH, AND TRACK LIGHTING TO BE ON SEPARATE SWITCH. CONTACTER & RELAY IF NECESSARY FOR LIGHT LOAD. 9. SWITCHES FOR AREAS 101 & 105 TO BE AT THIS LOCATION. 10. BULKHEAD AT 12' -10" AFF TO ALIGN WITH TOP OF WINDOW MULLION. SEE DETAIL /SECTION 6 ON SHEET A -5. *THE BUILDING /SHELL IS NEW CONSTRUCTION AND WAS NOT COMPLETE FOR FIELD VERIFICATION PRIOR TO THIS PLAN /SUITE BEING ISSUED FOR CONSTRUCTION. F I ld 429 N S-�uae 333 -,;; - �sy -, ,r;: r %jam / ,, A DIVISION OF J. GREG ALLEN 802 MULBERRY STREET, B -I U R R A N NOBLESVILLE, INDIANA 46060 317. 773. 9804 VOICE 317. 773 . 9828 FAX WWW.CURRAN- ARCHITECTURE.com 03 ISSUED FOR STATE REVIEW 9/29/0 02 ISSUED FOR CLIEN,T:RUw 9/25/0 01 ISSUED FOR PLAN REVIEW 9/5/06 NO. DESCRIPTION DATE THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLY AS INTENDED BY THE AGREEMENT WITH LOHR DESIGN, INC. NO OTHER USE OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF LOHR DESIGN, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY RESERVED. REFLECTED CEILING PLAN PROJECT NO.: 06- 561.002 DATE: 7/5/06 SCALE:1 /8" =1' -0" DRAWN: CO /JB CHECKED: MDL APPROVED: XXX A -2 PLAN NORTH