HomeMy WebLinkAbout06080001.28ELECTRICAL PLAN- 2ND FLOOR
SCALE: 1/8" = 1' -0"
ELECTRICAL PLAN- 1ST FLOOR
SCALE: 1/8" = 1' -0"
GENERAL ELECTRICAL NOTES
1. THESE DRAWINGS ARE FOR QUANTITY AND LOCATION OF
DEVICES ONLY. REFER TO ENGINEERING DOCUMENTS FOR
FURTHER INFORMATION.
2. ALL ELECTRICAL RECEPTACLES NEAR WATER SOURCES
SHALL BE 'GFI' TYPE PER CODE.
3. INDICATOR "D" NEXT TO A RECEPTACLE INDICATES
DEDICATED CIRCUIT.
4. TEMPORARILY LOCATE ANY / ALL ALARMS AND DETECTORS
DURING CONSTRUCTION OF A SPECIFIC AREA. REINSTALL AS
NECESSARY AND VERIFY WITH CODE.
5. ELECTRICAL CONTRACTOR TO PROVIDE ALL NEW POWER
AND TO PROVIDE CONDUIT AND JUNCTION BOXES FOR DATA /
PHONE CONTRACTOR TO COORDINATE WITH TENANT.
6. EXTEND OUTLETS FLUSH WHERE INTERFACES WITH
CASEWORK OR NEW CONSTRUCTION. COORDINATE CASEWORK
WITH INSTALLER.
7. ALL NEW RECEPTACLES AND SWITCH PLATES SHALL BE
(IVORY) UNLESS NOTED OTHERWISE.
8. ALL POWER AND COMMUNICATION SHOWN IS NEW.
CONTRACTOR TO VERIFY IN FIELD EXISTING POWER AND
COMMUNICATIONS RECEPTACLES.
9. FINAL EQUIPMENT AND FIXTURE LOCATIONS TO BE VERIFIED
WITH TENANT.
10. IF REQUIRED ALL FLOOR AND JUNCTION BOXES TO BE
FLUSH FLOOR MOUNTED.
11. VERIFY EXISTING RECEPTACLE LOCATIONS WITH NEW AND
REUSE ANY EXISTING RECEPTACLES OR JUNCTION BOXES WHEN
POSSIBLE OR FEASIBLE.
12. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR
BALANCING (INDEXING) THE ELECTRIC PANEL.
ELECTRICAL LEGEND
Gm
GFI (ANTI SHOCK) DUPLEX
AT SPECIFIC HEIGHT
0
DUPLEX RECEPTACLE AT
9/25/0
01
BLDG. STANDARD HEIGHT
9/5/06
N0.
QUADRAPLEX RECEPTACLE
AT
BLDG. STANDARD HEIGHT
>w
WALL PHONE. MOUNT AT
54" AFF TO TOP OF PHONE.
P
PHONE /DATA OUTLET
D
DEDICATED RECEPTACLE
[�Tv��)
CABLE / DUPLEX OUTLET
FOR TV. VERIFY HEIGHTS.
SPECIFIC KEY NOTES (D
1. OUTLET SHALL BE LOCATED WITHIN MICROWAVE
CASEWORK /SHELF. VERIFY HEIGHT.
2. VERIFY HEIGHT OF RECEPTACLE.
3. RECEPTACLES TO BE CHILD - PROOF.
4. ALL NEW WORKSTATIONS SHOWN SHALL HAVE
DATA /VOICE /ELECTRICAL RECEPTACLES. TENANT
SHALL VERIFY FURNITURE SYSTEM CONNECTION DEVICES
(WHIP) WITH VENDOR, PRIOR TO FINAL WALL DEVICE
DETERMINATION.
5. PROVIDE FIRE RETARDANT PLYWOOD PANEL
MOUNTED TO WALL FOR PHONE SYSTEM MOUNTING.
VERIFY FINAL LOCATION AND REQUIRMENTS WITH PHONE
CONSULTANT.
6. PROVIDE COMPUTER /SERVER SYSTEM. VERIFY
FINAL LOCATION AND REQUIREMENTS WITH TENANTS
DATA CONSULTANT.
7. VERIFY TYPE OF RECEPTACLE REQUIRED AND FINAL
LOCATION WITH TENANT /EQUIPMENT CONSULTANT.
8. REFRIGERATORS AND EQUIPMENT IN THESE ROOMS
TO BE CONNECTED TO TEMPORARY BATTERY BACK -UP.
VERIFY FINAL EQUIPMENT LOCATIONS AND
REQUIREMENTS WITH TENANT.
9. VERIFY FINAL LOCATION OF ELECTRICAL DEVICES
WITH PHONE /DATA CONSULTANTS.
10. ANALOG LINE FOR SPEAKER PHONE. VERIFY WITH
TENANT.
11. PROVIDE POWER FOR RELOCATED RECESSED VIEW
BOX.
12. PROVIDE WIRELESS INTERNET ACCESS ABOVE
CEILING TILE AT THIS LOCATION. PROVIDE POWER FOR
STSTEM.
u
F7
Rill,
4,29 N
,'. 41,62,0 4,
A DIVISION OF J. GREG ALLEN
802 MULBERRY STREET, B -I C U R R A N
NOBLESVILLE, INDIANA 46060 ARCHITECTURE
317. 773. 9804 VOICE
317. 773 . 9828 FAX WWW.CURRAN- APCHITECTURE.COM
03
ISSUED FOR STATE REVIEW
9/29/0
02
ISSUED FOR CLIENT REVIEW
9/25/0
01
ISSUED FOR PLAN REVIEW
9/5/06
N0.
DESCRIPTION - -- - -
DATE
THIS DRAWING SET IS PROVIDED IN .CONFIDENCE AND SHALL
BE USED ONLY AS INTENDED BY.THE AGREEMENT WITH LOHR
DESIGN, INC. NO OTHER USE OR DUPLICATION MAY BE MADE
WITHOUT PRIOR WRITTEN CONSENT' OF`LOHR DESIGN, INC.
ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY
RESERVED.
NORTHSIDLIENT
PINNACLE POINTE
MEDICAL PLAZA
12065 OLD MERI °IAN ST.
CARM EL, IN 46032. .
��� \11111111I���r
N o.
• 9600043 +�
STATE OF
�q
I
DRRES 11 /30/07
ELECTRICAL,
VOICE, DATA
PLAN
PROJECT NO.: 06- 561.002
DATE: 7/5/06
SCALE:1 /8 " =1' -0"
DRAWN: CO /JB I PLAN NORTH
CHECKED: MDL
APPROVED: XXX