Loading...
HomeMy WebLinkAbout06080001.8i ARCHITECTURAL PLAN SCALE: 1/8" = 1' -0" i PARTITION 1111111111111111 EXISTING PARTITION TO REMAIN I i NEW PARTITION 4 7/8" WITH SOUND INSULATION UNLESS NOTED OTHERWISE. 10' -0" H UNLESS NOTED OTHERWISE. SEE DETAIL #1 ON SHEET A -1.1. NEW LOW WALL PARTITION - SEE ELEVATIONS FOR HEIGHTS NEW PARTITION 4 7/8" TO DECK WITH SOUND INSULATION. SEE DETAIL #2 ON SHEET A -1.1. NEW PARTITION TO DECK - 7 1/4" PLUMBING WALL WITH SOUND INSULATION. SEE DETAIL #3 ON SHEET A -1.1. GENERAL CONSTRUCTION NOTES 1. THESE DRAWINGS ARE INTENDED TO OUTLINE THE GENERAL SCOPE OF THE WORK. EACH CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS ON ALL DRAWINGS AND IN FIELD PRIOR TO BIDDING BEFORE STARTING ANY WORK. CONTRACTORS SHALL ALSO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND GENERALLY ACCEPTED TRADE PRACTICES, AND ALL REGULATORY AGENCIES. 2. EACH CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND SHALL REPORT ANY DISCREPANCIES TO THE DESIGNER PRIOR TO CONSTRUCTION. 3. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. LARGE SCALE DETAILS OVER SMALL SCALE. GENERAL & SPECIFIC NOTES TAKE PRECEDENCE. 4. GENERAL CONTRACTOR WILL SEE THAT ALL SUBCONTRACTORS RECEIVE COMPLETE SETS OF WORKING DRAWINGS. 5. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR BALANCING (INDEXING) THE ELECTRICAL PANEL. 6. ALL DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL UNLESS NOTED OTHERWISE. 7. ALL DOORS SHALL BE 6" FROM PERPENDICULAR WALL UNLESS NOTED OTHERWISE. 8. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS PRIOR TO FLOORING INSTALLATION. ADJUST DOORS AND FRAMES AS REQUIRED. 9. PROVIDE NECESSARY BLOCKING (FIRE TREATED), CONCEALED WITHIN THE CONSTRUCTION, AS REQUIRED FOR ANY & ALL ITEMS THAT MUST BE SECURED TO THE WALL. SEE CASEWORK DRAWINGS. 10. TYPICAL NEW WALL CONSTRUCTION SHALL BE 3 5/8 ", 20 GAUGE METAL STUDS SPACED 16" ON CENTER WITH 5/8" F.R. GYP. BOARD, BOTH SIDES TO 10' -0" A.F.F. U.N.O. TAPE, SPACKLE AND SAND DRYWALL TO PREPARE FOR NEW FINISH. ALL NEW PARTITIONS THAT ENCLOSE ROOMS TO HAVE SOUND ATTENUATION BATT INSULATION FLOOR TO CEILING AND DRAPED ABOVE PARTITION S -0" TO EACH SIDE UNLESS NOTED OTHERWISE. 11. ALL SURFACES TO BE PROPERLY PREPARED TO RECEIVE NEW FINISHES. ALL SANDING SHALL EMPLOY THE USE OF A VACUUM ATTACHED SANDER IF BUILDING IS OCCUPIED. 12. ALL FINISHES TO BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS FOR A PARTICULAR SURFACE. PROVIDE CUT SHEETS TO OWNER ON ALL FINISH MATERIALS WITH ALL TESTING, PARTINGS, ETC., AND MAINTENANCE INFORMATION. 13. GENERAL CONTRACTOR TO VERIFY SIZE, LOCATION, AND CHARACTERISTICS OF ALL WORK AND EQUIPMENT SUPPLIED BY THE OWNER OR OTHERS, WITH THE MANUFACTURER OR SUPPLIER PRIOR TO THE START OF RELATED WORK. 14. CONTRACTOR TO COORDINATE ALL POWER & COMMUNICATION INSTALLATION WITH TENANT FOR PROPER PLACEMENT. 15. FURNISH COMPLETE SHOP AND INSTALLATION DRAWINGS OF ALL FINISHES, CABINETRY, FINISH CARPENTRY ITEMS TO THE DESIGNER FOR REVIEW PRIOR TO FABRICATION OF ANY ITEMS. SHOP DRAWINGS SHALL SHOW IN DETAIL ALL JOINTING, ANCHORAGE, SIZE, FINISH, SEAMS, AND ALL OTHER PERTINENT INFORMATION. 16. FLOORING CONTRACTOR TO FEATHER SUB FLOOR AT AREAS WHERE MULTIPLE FLOOR COVERINGS MEET TO ENSURE LEVEL TRANSITION. 17. STRUCTURAL, MECHANICAL, ELECTRICAL & FIRE SAFETY ENGINEERING WILL BE PROVIDED BY OTHERS IN A DESIGN BUILD MANNER AS REQUIRED. 18. ALL NEW CONSTRUCTION TO MEET A.D.A. COMPLIANCE. 19. ALL TRADES RESPONSIBLE FOR MATERIAL DELIVERY TO SITE. PROPER STORAGE SHALL NOT IMPEDE OWNER'S ACTIVITIES. 20. BUILDING OWNER TO PROVIDE WINDOW TREATMENTS /BLINDS. 21. MINIMIZE TYPICAL COLUMN ENCLOSURES, UNLESS NOTED OTHERWISE BY DIMENSIONS. 22. IN EXISTING DEMISING PARTITIONS SHOWN ON PLAN, PROVIDE SOUND INSULATION FULL HEIGHT. 23. EXTERIOR WALLS TO RECEIVE GYPSUM BOARD. 24. PROVIDE FLOOR DRAIN IN ALL TOILET ROOMS - VERIFY WTIH TENANT. PRICING ALTERNATE(S) 1. PROVIDE PRICE FOR THE DELETION OF RECESSED WALL MOUNTED TRASH RECEPTACLES /PAPER TOWEL DISPENSER COMBINATION UNITS IN TOILET ROOMS ( #107, #133, #134, #140, #142) 2. PROVIDE PRICE FOR THE ADDITION OF A CABLE OUTLET (TO INCLUDE ALL NECESSARY WIRING AND LABOR COSTS) TO BREAK /CONFERENCE ROOM #110. MOUNTED AT 7' -6" AFF. SPECIFIC KEY NOTES G) 1. HEAVY DUTY, ADJUSTABLE MELAMINE SHELVING, BRACKETS AND STANDARDS. 5 HIGH AND 12" DEEP. PROVIDE BLOCKING IF NEEDED. 2. HEAVY DUTY, ADJUSTABLE MELAMINE SHELVING (12" DEEP), BRACKETS AND STANDARDS. SEE ELEVATION "M" ON SHEET A -5. PROVIDE BLOCKING IF NEEDED. 3. EXISTING DEMISING PARTITION /BUILDING PARTITION. 4. DOOR WITH ACCESS CONTROL SYSTEM /CARD READER - VERIFY WITH BUILDING OWNER. 5. SPANDREL GLASS IN THIS LOCATION. VERIFY WITH BUILDING OWNER. FRAME WALL TO COVER SPANDREL PANEL WITH METAL STUDS, BATT INSULATION, VAPOR BARRIER AND 5/8" GYPSUM BOARD FROM SILL WALL TO 10' -0" AFF. 6. KEEP CLEARANCE BETWEEN NEW PARTITION AND EXTERIOR WALL AT 9" - LEAVING ENOUGH SPACE TO FINISH OUT AREA PROPERLY AND CLEAN. 7. STAINLESS STEEL PASS - THROUGH: BOBRICK, B -505, RECESSED SPECIMEN PASS -THRU CABINET, ROUGH WALL OPENING: 11 1/2 "W X 10 7/8 "H. SEE ELEVATION "L" ON SHEET A -3. 8. HEAVY DUTY, ADJUSTABLE MELAMINE SHELVING, BRACKETS, AND STANDARDS. EIGHT (8) SHELVES HIGH. VERIFY SPACING OF STANDARDS WITH MANUFACTURER. PROVIDE BLOCKING. 12" DEEP IN ROOM #1136. 15" DEEP IN ROOM #105. 9. 24" DEEP, HEAVY DUTY, ADJUSTABLE MELAMINE SHELVING, BRACKETS, AND STANDARDS. FOUR (4) SHELVES HIGH. VERIFY SPACING OF STANDARDS WITH MANUFACTURER. PROVIDE BLOCKING. 10. SLIDING TEMPERED GLASS WINDOW. 11. CUSTOM FISH TANK. DETAILS TO FOLLOW. 12. WOOD CAP (STAINED TO MATCH DOORS) ON LOW WALL AT 42" AFF. 13. PROVIDE BLOCKING FOR WALL - MOUNTED, FOLD -DOWN BABY CHANGING STATION /TABLE. CONTRACTOR TO PROVIDE BABY CHANGING STATION - VERIFY MODEL WITH TENANT. 14. PROVIDE TOILET ACCESSORIES: MIRROR ABOVE SINK, TOILET PAPER DISPENSER, SOAP DISPENSER, GRAB BARS, PAPER TOWEL DISPENSER & LOOSE TRASH RECEPTACLE (SEE PRICE ALTERNATE(S) #1 ON SHEET A -1). 15. PROVIDE BLOCKING FOR MAGAZINE /LITERATURE RACK. MAGAZINE /LIT. RACK: TBS. 16. ORIGIN OF TELEPHONE AND COMPUTER SYSTEMS. PROVIDE PAINTED /FR PLYWOOD PANEL FOR COMMUNICATIONS PANEL. VERIFY SIZE AND LOCATION WITH TENANT'S IT CONSULTANT. PROVIDE BLOCKING IF NECESSARY. 17. PROVIDE MINIMAL COLUMN ENCLOSURE - PREPARE FOR FINISHES. 18. VERIFY WITH BUILDING OWNER DOOR ACCESS CONTROL SYSTEM /CARD READER ON THIS DOOR. 19. VERIFY TELEVISION DIMENSIONS WITH TENANT. PROVIDE BLOCKING (VERIFY HEIGHT) FOR WALL HUNG TELEVISION. 20. LOW WALL WITH 12 "W X 1 -1/2" THICK SOLID SURFACE TRANSACTION COUNTER AT 40" AFF. VERIFY LENGTH. 21. LOW WALL WITH 12 "W X 1 -1/2" THICK SOLID SURFACE TRANSACTION COUNTER AT 42" AFF. VERIFY LENGTH. 22. BUILDING CHASE - COORDINATE AND VERIFY DIMENSIONS WITH PLUMBING CONTRACTOR. 23. VERIFY NEW FILING SYSTEM WITH TENANT. SYSTEM MAY REQUIRE CUTTING INTO SLAB OR ALTERING IT PRIOR TO THE CONCRETE POUR. 24. PROVIDE COAT ROD AND SHELF. ROD TO BE MOUNTED AT 66" AFF ON CENTER. PROVIDE 24 "W SECTION OF ROD AND SHELF FOR COMPLIANCE WITH ADA (AT 54" AFF). 25. PROVIDE VENTING TO OUTSIDE FOR DRYER. 26. PROVIDE BLOCKING FOR TWO CHART RACKS (STACKED) OUTSIDE EVERY EXAM ROOM DOOR. VERIFY MOUNTING HEIGHTS. CHART RACKS: TBS. 27. PLASTIC LAMINATE, DECORATIVE PANEL. CASEWORK CONTRACTOR TO DISCUSS FINAL DESIGN AND DIMENSIONS WITH INTERIOR DESIGNER. PLUMBING KEY NOTES 1. PROVIDE 1/4" COLD WATER LINE FOR REFRIGERATOR WATER DISPENSER AND ICE MAKER. VERIFY REFRIGERATOR MODEL WITH TENANT. 2. PROVIDE DOUBLE SINK /FAUCET WITH GARBAGE DISPOSAL. 3. PROVIDE RECESSED WASHING MACHINE HOOK UP - VERIFY MODEL WITH TENANT. 4. PROVIDE FLOOR DRAIN. 5. PROVIDE 24" X 24" MOP BASIN AND FAUCET. *THE BUILDING /SHELL IS NEW CONSTRUCTION AND WAS NOT COMPLETE FOR FIELD VERIFICATION PRIOR TO THIS PLAN /SUITE BEING ISSUED FOR CONSTRUCTION. A /r ,,,i % S?, 3 3 �L A DIVISION OF J. GREG ALLEN 802 MULBERRY STREET, B -I , .:.:.::U R R A N NOBLESVILLE, INDIANA 46060 317. 773 . 9804 VOICE maniitoja*ii 317. 773 . 9828 FAX WWW.CURRAN- ARCHITECTURE.COM 02 ISSUED FOR STATE PLAN REVIEW 9/29/0 01 ISSUED FOR 90% REVIEW: 8/03/06 N0. DESCRIPTION.-.........: DATE THIS DRAWING SET IS PROVIDED IN ,CONFIDENCE AND SHALL BE USED ONLY AS INTENDED BY THE:.. AGREEMENT WITH LOHR DESIGN, INC. NO OTHER USE OW: `DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT :::.OF::;:LOHR DESIGN, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY RESERVED. MERIDIAN PEDIATRICS • 9600043 CTATF OF ONO ARCHITECTURAL PLAN PROJECT NO.: 06- 561.001 DATE: 6/30/06 SCALE: 1 /8 " =1 ' -0" DRAWN: AW /J13 CHECKED: MDL APPROVED: A -1 PLAN NORTH