HomeMy WebLinkAbout06080001.9DIMENSION PLAN SCALE: 1/8" = 1' -0" c c 3RACE TO STRUCTURE ABOVE AS NEEDED LAYIN CEILING TYPICAL CEILING HEIGHT 9' -0 ", UNO. MINERAL WOOL BATT INSULATION STAPLED TO DRYWALL OR FRICTION FITTED BETWEEN STUDS. COORDINATE WITH STUD SIZE FOR MAX ALLOWED INSULATION WIDTH. 5/8" FR GYPSUM BOARD 3 5/8" STEEL STUDS ® 16" OC FLOOR BASE ACOUSTICAL SEALANT NEW PARTITION - 3 5/8" TYPICAL WITH SOUND INSULATION TO DECK SCALE: 3 " =1' UNDERSIDE OF STRUCTURE ABOVE UNLESS NO OTHERWISE ACOUSTICAL SEALANT LAYIN CEILING TYPICAL CEILING HEIGHT 0 9' -0 ", UNO. MINERAL WOOL SOUND BATT INSULATION STAF TO DRYWALL OR FRICTION FITTED BETWEEN Sl COORDINATE WITH STUD SIZE FOR MAX ALLOY INSULATION WIDTH. 5/8" FR GYPSUM BOARD 3 5/8" STEEL STUDS ® 16" OC FLOOR BASE ACOUSTICAL SEALANT 1]""' 1' -8" 3' -0" 2' -1" DIMENSION PLAN - DETAIL NURSE -ROOM 144 SCALE: 3/8" = 1' -0" PARTITION LEGEND EXISTING PARTITION TO REMAIN NEW PARTITION 4 7/8" WITH SOUND INSULATION UNLESS NOTED OTHERWISE. 10' -0" H UNLESS NOTED OTHERWISE. SEE DETAIL #1 ON SHEET A -1.1. NEW LOW WALL PARTITION - SEE ELEVATIONS FOR HEIGHTS NEW PARTITION 4 7/8" TO DECK WITH SOUND INSULATION. SEE DETAIL #2 ON SHEET A -1.1. NEW PARTITION TO DECK - 7 1/4" PLUMBING WALL WITH SOUND INSULATION. SEE DETAIL #3 ON SHEET A -1.1. SINGLE TRACK "FRICTION FIT" SLIP TRACK UNDERSIDE OF STRUCTURE ABOVE UNLESS NOTED OTHERWISE ACOUSTICAL SEALANT METAL RUNNER CHANNEL ANCHORED TO STRUCTURE: DO NOT ATTACH STUDS TO TOP RUNNER. TYPICAL CEILING HEIGHT 9' -0" MINERAL WOOL BATT INSULATION STAPLED TO DRYWALL OR FRICTION FITTED BETWEEN STUDS. COORDINATE WITH STUD SIZE FOR MAX ALLOWED INSULATION WIDTH. 6" STEEL STUDS ® 16" OC 5/8" FR GYPSUM BOARD METAL RUNNER ANCHORED TO FLOOR FLOOR BASE ACOUSTICAL SEALANT SPECIFIC KEY NOTES 0 1. ALIGN. 2. CENTER PARTITION ON WINDOW MULLION 3. WIDTH OF ROOM NOT TO BE LESS THAN 8' -6 ". CONTACT DESIGNER IF DISCREPANCY OCCURS. 4. BEGIN BUILD -OUT AT THIS POINT. 5. WIDTH OF ROOM NOT TO BE LESS THAN 8' -9 ". CONTACT DESIGNER IF DISCREPANCY OCCURS. 6. PROVIDE MINIMAL COLUMN ENCLOSURE - PREPARE FOR FINISHES. 7. FLUSH OUT COLUMN ENCLOSURE AND STAIRWELL WALL IF POSSIBLE. VERIFY DIMENSIONS OF AFFECTED ROOM PRIOR TO CONSTRUCTION. *THE BUILDING /SHELL IS NEW CONSTRUCTION AND WAS NOT COMPLETE FOR FIELD VERIFICATION PRIOR TO THIS PLAN /SUITE BEING ISSUED FOR CONSTRUCTION. r L 0 H R D jiiii // S % % ���o� 4'29 N poliis, IN 162041, A DIVISION OF J. GREG ALLEN 802 MULBERRY STREET, B -I U R R A N NOBLESVILLE, INDIANA 46060 317. 773 . 9804 VOICE 317. 773 .9828 FAX VWVW.CURRAN- ARCHITECTURE.COM 02 ISSUED FOR STATE PLAN REVIEW 9/29/0 01 ISSUED FOR 90% REVIEW 8/03/06 N0. DESCRIPTION = DATE THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLY AS INTENDED BY THE AGREEMENT WITH LOHR DESIGN, INC. NO OTHER USE OR "DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSEN'>0* L014R DESIGN, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY RESERVED. MERIDIAN PEDIATRICS PINNACLE POIN;T':..�::... ...:.:... MEDICAL PLAZA 12065 OLD MERIDIAN ST. CARM E L, IN 46002 1 \\���11111f�j1 /,rrr �\�P ��G \STEM± C-3 No. • 9600043: STATE OF 9 DIMENSION-,- PLAN & PARTITION SECTIONS PROJECT NO.: 06- 561.001 DATE: 6/30/06 SCALE: $ " =1' —O" DRAWN: AW /JB CHECKED: MDL APPROVED: Aml ■ PLAN NORTH E