HomeMy WebLinkAbout06080101.192 4 5 6 8 10 11 1 12 13 1 14 1 15 16 N I N < 04s� � � < (5 ) % __j j------- Lij CL uj M 2214 METROCENTER BLVD. M SUITE 128 ri NASHVILLE, TN 37228 OFFICE 6 1 S.2S6.7038 FAX 615.2S6.7132 Lli Q- -CAP EXISTING TAPS. V) ii 0 DISCONNECT EXISTING MECHANICAL DEMOLITION NOTES: L ELECTIRICAL. COORDINATE I I WITH DIVISION 16 I I IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE CONDITION OF L EXISTING EQUIPMENT, EXACT SIZES OF EXISTING DUCT, ETC. BEFORE DEMOLITION WORK BEGINS. CD 2. DEMOLITION WORK SHALL BE PHASED TO ACCOMPLISH REPLACEMENT WITH 0 00 00 REMOVE EXISTING VAV REHEAT BOXES AND FAN MINIMUM AMOUNT OF DOWNTIME. C�l Z C,4 C-4 (D r-- ce) -Rd- 1 POWERED BOXES IN THIS AREk REMOVE ALL 3. SCHEDULE NEW AND DEMOLITION WORK IN ADVANCE WITH OWNER. ce) SUPPLY AND RETURN DUCT IN THIS AREA. cn DUCTWORK SHOWN ON THIS DRAWING HAS NOT 4. CONTRACTOR SHALL REMOVE EXISTING HVAC EQUIPMENT AND ASSOCIATED (D z 00 00 K BEEN FIELD VERIFIED. IT HAS BEEN SHOWN FOR MATERIALS AS SHOWN AND TURN OVER TO OWNER OR REMOVE FROM SITE AS -00 00 GENER& SCOPE OF: DEMOLMON WORK. DIRECTED BY OWNER. K j— (D ATI 5. CONTRACTOR SHALL VERIFY CLEARANCE REQUIREMENTS AND INDICATE ROUTING co -5; LO u) OF NEW DUCTWORK BEFORE FABRICATION BEGINS AS RISES AND DROPS MAY cp cr) cu to to BE NECESSARY BECAUSE OF EXISTING FIELD CONDITIONS. Z F— L.L. 6. COORDINATE WITH MECHANICAL AND ELECTRICAL CONTRACTOR ALL CEILING REMOVAL WHICH IS REQUIRED TO ACCESS THEIR WORK AND IS NOT DESIGNATED FOR REMOVAL. NOTIFY ARCHITECT AND OWNER PRIOR TO COMMENCING REMOVAL. IF EXISTING CEILING IS DETERMINED TO REQUIRE REMOVAL, REMOVE ONLY THAT PORTION NECESSARY TO ACCESS AND COMPLETE THE NEW WORK. UPON COMPLETION OF THE ABOVE CEILING WORK, CEILING EXISTING TRANSFER OMLLE TO REMAIN IS TO BE REPLACED TO MATCH EXISTING CEILING. 7. A MEASUREMENT OF EXISTING SYSTEMS AFFECTED BY THIS RENOVATION SHALL BE PERFORMED AND RECORDED BY THE BALANCING CONTRACTOR PRIOR TO THE COMMENCEMENT OF ANY DEMOLITION WORK. THESE MEASUREMENTS H SHALL INCLUDE THE FOLLOWING: t * SUPPLY AND RETURN AIR FLOWS AT EXISTING AIR HANDLING UNIT. * MEDIUM PRESSURE SUPPLY AIR FLOW AT ENTERING SIDE OF TERMINAL REHEAT H BOXES. VERIFY MFR. LOCATIONS AND CAPACITIES. THE AIR DISTRIBUTION SYSTEM(S) SHALL BE REBALANCED TO MEET EXISTING AIR FLOWS AS WELL AS NEW AIR FLOW REQUIREMENTS AS INDICATED ON THE NEW CONSTRUCTION HVAC DOCUMENTS. AREAS SERVED BY AFFECTED EXISTING SYSTEMS NOT RENOVATED IN THIS PROJECT SHALL BE REBALANCED TO AIR FLOWS EXISTING PRIOR TO COMMENCEMENT OF WORK. 8. THE BALANCING CONTRACTOR SHALL NOTIFY THE OWNER AND THE ENGINEER OF DEFICIENCIES FOUND IN ANY OF THE SYSTEMS LISTED IN NOTE # 7. 0 G G it < ct� 0 u� -------------- --------- __j -0 < I 0 U F F LLJ u if __j --�JJIL L.Lj < u ry 0" F- ry < 0 =77-7 u E E D D fill rI If! aw DRAWN: LKK PROJECT ARCHITECT' SPP X PROJECT MANAGER: LKK C REVISIONS: c 6� 'j,/ Ley— d) ... ... . . .. JOB# 05098 FILE: DATE: JULY 21, 2006 B B LEGEND HVAC DEMOLITION PLAN '.NO. SCALE: 1/8" FI EXISTING TO REMAIN PETO STAT DEMOLITION WI ... ........ 1) It 111111 0 2' 4' 8' 16' - - --- A TRUE A tiVAC NORTH Demolition Plan A 2 1 3 1 4 7 8 11 1 12 13 6 @I