Loading...
HomeMy WebLinkAbout06080101.2J 13 - - - ---i ------ - - - - -- I r -- I I � L-----i-- ---------- I _ I (- -i. I 15 I I I I I I I I I I 1 i' I! I 12 11 I I ill l I I i I I •I j� r 4 fiI I ll If i I SEE �'t� -1� I 2 ! i I I I I !I I J �� I w ���i I -- - - -� - - - - -- - -o i ► l I SEE ALT n SWEET AIM I I f 4 ! I I 5 I b SEE ALT 03 I I f SHEET A102 _z I I r- - - - --, 5 \ I I I Ib Ill I 6 - -i =___ - • - - -- - - - - -- - — - - -- -o -- -- - -- - -- - -- -- 1 I II 15 8 I �I�I I II 4 4 i \ I� I 14 � I I 1�i � I II i 5 II i -- v7— 11 ! Q I I ' �`I II I I 19 � j I SHEET AIM LI 15 i ,III s i i I i I ItH �! /' SEETA1.02 WALL_ LEGEND - DEMOLITION Ffl DEMOLITION KEYNOTE EXI5TING TO REMAIN = EXISTING TO BE REMOVED DEMOLITION KEG NOTES: 1_l REMOVE EXISTING GYP. BD. AND STUD FURR -OUT AND ALL COMPONENTS WITHIN TO EXPOSED EXISTING BLOCK WALL, TYPICAL AT FRONT OF WINDOWS AT EXTERIOR WALL. CONTRACTOR TO CORE DRILL (3 INCH MAX DIAMETER) TO VERIFY IF EXISTING BLOCK CELLS ARE INSULATED. ARCHITECT TO BE NOTIFIED OF FINDINGS BEFORE PROCEEDING. REF. ALT 04, A102. 2[]. REMOVE EXISTING BULKHEAD CEILING ABOVE ALONG EXISTING WINDOWS, INCLUDING ALL FRAMING STUDS, BRACING AND GYP. BD. 03 REMOVE PORTIONS OF EXISTING WINDOW SYSTEM TO ACCOMMODATE NEW EXTERIOR DOOR INSTALLATION (REF PLAN FOR LOCATION). EXISTING LINTEL SHALL NOT BE BROKEN TO MAINTAIN EXISTING CONDITIONS. ® REMOVE ALL EXISTING GLUE AND DEBRIS FROM EXISTING SLAB THROUGHOUT RENOVATED AREA. PREP CONCRETE FLOOR TO RECEIVE NEW FLOOR FINISHES. 05 REMOVE EXISTING WALL PARTITIONS AS SHOWN ON PLAN. COORDINATE WITH NEW PARTITION LOCATIONS. ® REMOVE EXISTING DOOR AND FRAME AS INDICATED ON PLAN. REMOVE EXISTING CEILING GRID AND TILE THROUGHOUT THE RENOVATED AREA. CONTRACTOR TO SECURE EXISTING CEILING GRID AT ADJACENT TENANT SPACE (BOTH OCCUPIED AND UNOCCUPIED) DUE TO CONTINUOUS GRID SYSTEM THROUGH EACH TENANT. 0 REMOVE PORTIONS OF EXISTING WALL PARTITION TO ACCOMMODATE NEW DOOR AS INDICATED ON PLAN. 10 REMOVE PORTIONS OF EXISTING SLAB FOR NEW RECESSED SCALE. REF. SHEET AIBI FOR LOCATION AND SPECIFICATIONS ON FLOOR OVERCUT SIZE (OVERCUT 42 "X62" AND CENTER SCALE IN PIT AND PARALLEL TO NEW WALL). 11 CONTRACTOR TO VERIFY CURRENT USE OF EXISTING TRAY ABOVE CEILING (PARALLEL WITH EXISTING COMMON CORRIDOR). EXISTING TRAY AND CABLING MAY NEED TO BE RELOCATED OR UNDISTURBED PER BUILDING OWNER'S INSTRUCTIONS. CONTACT ARCHITECT ON FINAL DECISION FOR HIS RECORDS. 12. EXISTING SPRINKLER LINES TO BE FIELD VERIFIED DURING CONSTRUCTION. REFERENCE PLUMBING DRAWINGS FOR FURTHER INSTRUCTIONS ON EXISTING/NEW SPRINKLER LINES /HEADS. 13. PREP EXTERIOR FINISH GRADE TO ACCOMMODATE NEW CONCRETE SIDE WALK AND GENERATOR PAD. REF. ALT 05 AND ''6, A102. 14. REMOVE PORTIONS OF EXISTING BLOCK AS LOCATED ON PLAN TO ACCOMMODATE NEW EXTERIOR DOOR SECURE STRUCTURAL LOAD ABOVE AS NECESSARY. REF. A102 FOR NEW DOOR LOCATION. 15. USE EXTREME CAUTION DURING DEMOLITION NOT TO DISTURB EXISTING STRUCTURAL COMPONENTS. 16. WORK TO BE PERFORMED ON ROOF FOR NEW RTU (REFERENCE PLAN FOR APPROXIMATE LOCATION). VERIFY WITH MECHANICAL DRAWINGS FOR MORE INFORMATION AND LOCATION. 1l. REMOVE EXISTING WALL PARTITION IN ADJACENT TENANT SPACE (PER BUILDING OWNER'S REQUEST). REMOVE PORTIONS OF EXISTING WALL WALL PARTITION IN ADJACENT TENANT FOR ROOM ACCESS (3' -4 ") OPENING (PER BUILDING OWNER'S REQUEST). 191 REMOVE EXISTING CASEWORK AS INDICATED ON PLAN. DEMOLITION GENERAL NOTES: 1. THE INTENT OF THE DEMOLITION PLAN IS TO REMOVE ALL ITEMS NOT REQUIRED FOR NEW CONSTRUCTION OR THAT 16 IN CONFLICT WITH NEW CONSTRUCTION, WHETHER OR NOT INDIVIDUALLY NUMBERED. THE CONTRACTOR SHALL REMOVE /RELOCATE ALL SUCH ITEMS AS REQUIRED FOR NEW CONSTRUCTION 2. THE CONTRACTOR SHALL VERIFY THESE DRAWINGS WITH EXISTING FIELD CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF INCONSISTENCIES BETWEEN THEM AND ACTUAL CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION. 3. THE CONTRACTOR SHALL ALSO NOTIFY THE ARCHITECT IMMEDIATELY IF ANY WORK INDICATED IN THE CONTRACT DOCUMENTS CAN NOT BE PERFORMED DUE TO EXISTING FIELD CONDITIONS. 4. IF ANY FIREPROOFING OR FIRE ASSEMBLIES WHICH ARE INDICATED TO REMAIN ARE DAMAGED DURING DEMOLITION, THEY SHALL BE REPAIRED TO CONFORM TO ORIGINAL FIRE PROTECTION REQUIREMENTS. 5. REMOVE EXISTING CONSTRUCTION AS INDICATED. TYPICAL WALL REMOVAL INCLUDES FINISHES AND MECHANICAL PLUMBING AND ELECTRICAL SYSTEMS CONTAINED THEREIN. REMOVE DOORS, CASEWORK, WINDOWS, FRAMES, AND OTHER FIXTURES AS REQUIRED. AFTER REMOVAL OF PIPE CHASES, PATCH HOLES IN EXISTING FLOORS OR WALLS TO REMAIN TO MEET ORIGINAL FIRE PROTECTION AND STRUCTURAL REQUIREMENTS. PATCH TO RECEIVE NEW FINISHES PER FINISH SCHEDULE OR PER INTERIOR FINISH PLANS. (WHERE NEW FINISHES ARE CALLED FOR ON EXISTING SURFACES, REMOVE THE EXISTING FINISH AND PREPARE SURFACE TO RECEIVE THE NEW FINISH -MATCH EXISTING, WHERE APPLICABLE.) 6. THE CONTRACTOR SHALL MAKE AVAILABLE TO THE OWNER, AND COORDINATE ANY ITEMS TO BE STORED AND /OR RELOCATED, SUCH AS: EQUIPMENT, DOOR FRAMES, PLUMBING FIXTURES, HARDWARE, LIGHTS AND /OR OTHER CEILING MOUNTED DEVICES. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWING FOR DEMOLITION OF UTILITIES. 8. FOR EXTENT AND LOCATION OF CHANNELING OF EXISTING FLOOR SLABS REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS, IF EXISTING PIPING OR CONDUIT WORK (OTHER THAN THE DESIRED CONNECTION) IS ENCOUNTERED WHILE CHANNELING, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT BEFORE CONTINUING. S. THE CONTRACTOR SHALL VERIFY THAT EXIT EGRESS 15 MAINTAINED FOR ALL OCCUPIED AREAS OF THE BUILDING THROUGHOUT CONSTRUCTION. 10. DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND AS SET FORTH BY ALL GOVERNING AUTHORITIES. THE CONTRACTOR SHALL BRACE ALL EXISTING STRUCTURES OR STRUCTURAL ELEMENTS AS NECESSARY DURING DEMOLITION. 12. THE CONTRACTOR SHALL NOT CUT STRUCTURAL WORK IN A MANNER RESULTING IN A REDUCTION OF LOAD CARRYING CAPACITY OR LOAD /DEFLECTION RATIO. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ALL STRUCTURAL CUTS PRIOR TO EXECUTION SO THAT APPROVAL CAN BE OBTAINED FROM THE ARCHITECT/ENGINEER- 13. THE EXISTING BUILDING ENVELOPE SHALL BE MAINTAINED IN A WATER TIGHT CONDITION AT ALL TIMES. 14. WHERE EXISTING CONSTRUCTION IS FOUND TO CONTAIN ASBESTOS, NOTIFY THE ARCHITECT PRIOR TO REMOVAL. REMOVAL DISPOSAL AND REPLACEMENT OF THE ASBESTOS MATERIAL SHALL BE IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS. REPLACE THE ASBESTOS MATERIAL WITH NEW MATERIALS AS SPECIFIED OR APPROVED BY THE ARCHITECT. 15, CONTRACTOR TO USE CAUTION WHEN TRENCH CUTTING SLAB FOR UNDERGROUND PLUMBING. EXISTING CONDUITS MAY EXIST UNDER EXISTING SLAB. ,, • 1p DEMOLITION FLOOR PLAN SCALE: I/O . I'_0" J F Q Lu � co N � U - O I`- M '� W I .. n m — z 1— _ co W CU U co co Q Lo of W co p co N C) CV ti 00 N N I`- M '� m cn > 1— 00 co ` CU 00 co co Lo Lo co Qo � z t O U ��U U :3 Lu Q ��U O OL U U U N: LKK IECT ARCHITECT: SPP IECT MANAGER: LKK ISIONS: ADD NO. 01 / 01 -21 -06 FILE: DATE: JULY 21, 2006 Qjg� G� r • TA TO [) 1'o I 10LITION FLOOR PLAN O