HomeMy WebLinkAbout06080101.23N x L J Ct E B PROVIDE FLEXIBLE DUCTWORK AND ELECTRICAL CONNECTIONS (TYP) ROOF CURB BY A/C UNIT MANUFACTURER. PROVIDE CURB WITH FINAL FILTERS FOR RTU -3. ROOF REFER TO ARCH. DWGS. .. t . 2 LAYER 5/8" GYP. BD. EACH SIDE CONNECTION SIZE SUPPLY DUCT NO LINING ,--A /C UNIT -J OUTSIDE AIR INTAKE MINIMUM 3' -0" FROM ROOF FOR RTU -3 CONNECTION SIZE RETURN AIR DUCT WITH 1" INTERNAL SOUND LINING UP TO UNIT FOR RTU -2 AND RTU -4 FILL INSIDE OF CURB WITH SOUND BATT INSULATION NOTE: 1. PIPE CONDENSATE FROM UNIT USING CONNECTION SIZE (3" MIN.) SPILL TO ROOF. PROVIDE "P" TRAP AT UNIT. SEE COOLING COIL CONDENSATE DRAIN DETAIL. ROOFTOP A/C UNIT NOT TO SCALE CLEARANCE ABOVE HIGHT ANTICIPATED SNOW LEVEL 2X"O I I 4"0 ROOF BOOT /FLASHING ROOF I I i 000000 SUPPORT COMBUSTION AIR VENT WATER HEATER VENT WITH CONCENTRIC VENT KIT THRU ROOF INTERIOR CURB OPENING REMOVABLE FAN HOUSING MOTOR NON -FUSED — DISCONNECT SWITCH FAN CONDUIT I1 11 I 1 11 f � I I I 11 I� jl PLAN VIEW V -BELT DRIVE SPUN ALUMINUM CAP BIRD SCREEN -ROOF CURB �- ROUTE POWER LEADS TO FAN INSIDE CORNER OF CURB FRONT VIEW NOTES : 1. PROVIDE MANUAL RESET FIRE -STAT AS REQUIRED. 2. BELT DRIVEN EXHAUSTER SHOWN. DETAIL IS SIMILAR FOR DIRECT DRIVE EXHAUSTER. 3. PROVIDE BACKDRAFT DAMPER AS REQUIRED. 4. CURB AND FAN FROM SAME MANUFACTURER. 5. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL BRACING AND TIE -DOWN REQUIREMENTS. POWER ROOF EXHAUSTER (P.R.E.) CAD ID: 08M121 NOT TO SCALE ALTERNATIVE: VANED ELBOW O1 DAMPERS FLOW TRANSITION WITH TRANSITION FOLLOWING O ELBOW T _ _ _ _ PF" UB BRANCH O TRANSITION O _ O TAKE OFF 3 45' MAX W3 x D3 t? FLOW o i HINGE OR ROD W 1D 1S (W2D2+ W3 D3) A xD1 B xD2 NOTE 1. BRANCH A?� W D W3 D3 - -- -SET SCREW - -- OO (2 2) (W 3 p 3) /W1 - - -- B�[ (W2 W2 D2 3/W W 1 x p1 CONTROL ROD WITH LOCK D2) + (W3 D3) 2 SPLITTER DAMPER BLADE FLOW LENGTH EQUAL TO 3/4 OF DUCT WIDTH; MIN 6" INSULATION PER NOTE 2 --------- - - - - -- -#`' SUPPLY AIR DUCTS WM MAIN AIR FLOW EXHAUST OR RETURN AIR DUCTS 1/4 W � �l 45' MAX � W M> W B OR 4" MIN I _ I I - - - -- OPPOSED BLADE MANUAL I I VOLUME DAMPER BELLMOUTH I W B I TAKE -OFF I BRANCH DUCT WIDTH, WB NOTES: 1. R 1 & R2 ARE RESPECTIVELY 1.75 AND 0.75 OF THE GREATER OF B OR W2 . 2. SUPPLY DUCT TO BE EXTERNALLY INSULATED. EXHAUST AND RETURN AIR DUCTS INSULATE PER SPECIFICATION. DUCT MAIN AND BRANCH TAKE OFFS CAD ID: 09M503 NOT TO SCALE MIN. 4' -0" STRAIGHT DUCT UPSTREAM AND DOWNSTREAM OF DUCT REHEAT COIL. AIR FLOW I I \ I I I 20' j I I 1� J ELECTRIC BOOSTER COIL. (SEE SCHEDULE FOR FLANGED OR SLIP -IN MOUNTING) 30'. 00 0 0 oOo TERMINAL BOX 12 "02" MIN. SIZE ACCESS PANEL ON MIN. 3' -6" WORKING BOTTOM OR SIDE CLEARANCE TO SERVICE TERMINAL BOX AND COILS DUCT MOUNTED ELECTRIC REHEAT COIL CAD ID: 09M105 NOT TO SCALE FLARED TAKE -OFF FITTING UAL VOLUME DAMPER i LOCKING QUADRANT NOTES: 1. AIR CUSHION REQUIRED AT END OF RUN FOR BRANCH TAKE OFFS ILLUSTRATED. 2. CUSHION DEPTH, D, EQUAL TO Y2 THE GREATER OF H OR W, SUBJECT TO 6" MINIMUM, WHERE H - HEIGHT OF DUCT. INTERNALLY LINED RETURN /EXHAUST DUCTWORK TEE DETAIL CAD ID; 09M502 NOT TO SCALE i� L J F �w • -C p Z 00 N O N I� 00 z M M N d. > Q Q 00 00 U z N _ 00 00 - co � ' -� icy v- Lo v- M v- c- N Z CD F- to Li W C) LL.! F-- X u RAWN: LKK ROJECT ARCHITECT. SPP ROJECT MANAGER: LKK EVISIONS: JOB# 05098 FILE: DATE: JULY 21, 2006 NA1. HVAC Details MG.02 � z U z O z LEI F= Q 12 U U z D D Q U � z z J z O 1 o _Q LLJ U � U Imo - ch-1 V Q z LJ U O �- RAWN: LKK ROJECT ARCHITECT. SPP ROJECT MANAGER: LKK EVISIONS: JOB# 05098 FILE: DATE: JULY 21, 2006 NA1. HVAC Details MG.02